Advertisement for orthosearch.org.uk
Results 1 - 20 of 96
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVI | Pages 4 - 4
1 Jun 2012
Kanna R Shetty A Rajasekaran S
Full Access

Study Design

Prospective analysis of computerised tomogram images of 376 normal pediatric cervical pedicles

Objectives and Summary of Background Data

Although the usage of cervical pedicle screws (CPS) in adults has become established, the feasibility of its application in children has not been studied. There are no in-vivo studies that define the normal pediatric cervical pedicle morphometrics and its changes with growth and development of the child.


The Bone & Joint Journal
Vol. 105-B, Issue 5 | Pages 543 - 550
1 May 2023
Abel F Avrumova F Goldman SN Abjornson C Lebl DR

Aims. The aim of this study was to assess the accuracy of pedicle screw placement, as well as intraoperative factors, radiation exposure, and complication rates in adult patients with degenerative disorders of the thoracic and lumbar spines who have undergone robotic-navigated spinal surgery using a contemporary system. Methods. The authors reviewed the prospectively collected data on 196 adult patients who had pedicle screws implanted with robot-navigated assistance (RNA) using the Mazor X Stealth system between June 2019 and March 2022. Pedicle screws were implanted by one experienced spinal surgeon after completion of a learning period. The accuracy of pedicle screw placement was determined using intraoperative 3D fluoroscopy. Results. A total of 1,123 pedicle screws were implanted: 1,001 screws (89%) were placed robotically, 63 (6%) were converted from robotic placement to a freehand technique, and 59 (5%) were planned to be implanted freehand. Of the robotically placed screws, 942 screws (94%) were determined to be Gertzbein and Robbins grade A with median deviation of 0.8 mm (interquartile range 0.4 to 1.6). Skive events were noted with 20 pedicle screws (1.8%). No adverse clinical sequelae were noted in the 90-day follow-up. The mean fluoroscopic exposure per screw was 4.9 seconds (SD 3.8). Conclusion. RNA is highly accurate and reliable, with a low rate of abandonment once mastered. No adverse clinical sequelae occurred after implanting a large series of pedicle screws using the latest generation of RNA. Understanding of patient-specific anatomical features and the real-time intraoperative identification of risk factors for suboptimal screw placement have the potential to improve accuracy further. Cite this article: Bone Joint J 2023;105-B(5):543–550


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_15 | Pages 12 - 12
7 Aug 2024
Jenkins AL Harvie C O'Donnell J Jenkins S
Full Access

Introduction. Lumbosacral transitional vertebrae (LSTV) are increasingly recognized as a common anatomical variant and is the most common congenital anomaly of the lumbosacral spine. Patients can have symptomatic LSTV, known as Bertolotti's Syndrome, where transitional anatomy can cause back, L5 distribution leg, hip, and groin pain. We propose an outline for diagnosis and treatment of Bertolotti's Syndrome. Methods. We retrospectively reviewed over 500 patients presenting to the primary author with low back, buttock, hip, groin and/or leg pain from April 2009 through April 2024. Patients with radiographic findings of an LSTV and clinical presentation underwent diagnostic injections to confirm diagnosis of Bertolotti's syndrome. Treatment was determined based on patient's LSTV classification. 157 patients with confirmed Bertolotti's syndrome underwent surgical treatment. Results. Over 500 patients presented with an appropriate clinical presentation and radiographic findings of an LSTV. Diagnostic injections were targeted into the transitional anatomy confirming the LSTV as the primary pain generator to make the diagnosis of Bertolotti's syndrome. The decision in the type of surgical intervention, resection or fusion, was made based on patient's LSTV anatomy. 157 patients with confirmed Bertolotti's Syndrome underwent surgical treatment (121 fusions (77%), 36 resections (23%)). The classification system and surgical outcomes, in part, have been previously published in World Neurosurgery. Conclusion. We have outlined the best practice of diagnosis and treatment selection for Bertolotti's syndrome. We have shown significant improvement in outcomes based on this method. We hope to aid in both patient education and provide an outline on how clinicians can become knowledgeable on Bertolotti's syndrome. Conflicts of interest. No conflicts of interest. Sources of funding. No funding obtained


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_9 | Pages 24 - 24
1 Oct 2022
Tavana S Leong J Freedman B Newell N
Full Access

Background. In vivo evaluation of IVD strains is crucial to better understand normal and pathological IVD mechanics, and to evaluate the effectiveness of treatments. This study aimed to 1) develop a novel in vivo technique based on 3T MRI and digital volume correlation (DVC) to measure strains within IVDs and 2) to use this technique to resolve 3D strains within IVDs of healthy volunteers during extension. Methods. This study included 40 lumbar IVDs from eight healthy subjects. The optimal MR sequence to minimise DVC uncertainties was identified by scanning one subject with four different sequences: CISS, T1VIBE, T2SPACE, and T2TSE. To assess the repeatability of the strain measurements in spines with different anatomical and morphological variations four subjects were scanned with the optimal sequence, and uncertainties of the strain measurements were quantified. Additionally, to calculate 3D strains during extension, MRIs were acquired from six subjects in both the neutral position and after full extension. Results. Measurement errors were lowest when using the T2TSE sequence (precision=0.33 ± 0.10%, accuracy=0.48 ± 0.11%). The largest average maximum tensile and shear strains were seen at the L2-L3 level in all volunteers (7.2 ± 1.5% and 6.8 ± 1.1%, respectively), while the L5-S1 level experienced the lowest average tensile and shear strains (3.5 ± 1.0% and 3.9 ± 0.7%, respectively). Conclusion. The findings of this study establish clinical MRI-based DVC (MRI-DVC) as a new tool for in vivo strain measurement within human IVDs. MRI-DVC successfully provided internal strain distributions within IVDs and has great potential to be used for a wide range of clinical applications. Conflict of interest: No conflicts of interest. Source of funding: This work was supported by the EPSRC, New Investigator Award, EP/V029452/1


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_8 | Pages 5 - 5
1 Aug 2022
Wardell D Jayasuriya R Totton N Mills A Breakwell L Cole A
Full Access

Thermal sensors have been used in bracing research as self-reported diaries are inaccurate. Little is known about new low-profile sensors, optimal location within a brace, locational thermal micro-climate and effect of brace lining. Our objective is to Determine an optimal temperature threshold for sensor-measured and true wear time agreement. Identify optimal sensor location. Assess all factors to determine the best sensor option for the Bracing AdoleScent Idiopathic Scoliosis (BASIS) multicentre RCT. Seven Orthotimer and five iButton (DS1925L) sensors were synchronised to record temperature at five-minute intervals. Three healthy participants donned a rigid spinal brace, embedded with both sensors across four anatomical locations (abdomen/axilla/lateral-gluteal/sacral). Universal-coordinated-time wear protocols were performed in/out-doors. Intraclass correlation coefficient (ICC) assessed sensor-measured and true wear time agreement at thresholds 15–36oC. Optimal thresholds, determined by largest ICC estimate: Orthotimer: Abdomen=26oC, axilla=27oC, lateral-gluteal=24.5oC, sacral=22.5oC. iButton: Abdomen=26oC, axilla=27oC, lateral-gluteal=23.5oC, sacral=23.5oC. Warm-up time and error at optimal thresholds increased for moulded sensors covered with 6mm lining. Location: anterior abdominal wall. Excellent reliability and higher optimal thresholds, less likely to be exceeded by ambient temperature; not a pressure area. Sensor: iButton, longer battery life and larger memory than Orthotimer; allows recording at 10 min intervals for life of brace. Orthotimer only able to record every 30 mins, increasing error between true and measured wear time; Orthotimer needs 6-monthly data download. Threshold: 26oC is optimal threshold to balance warm-up and cool-down times for accurately measuring wear time. Sensor should not be covered by lining foam as this significantly prolongs warm-up time


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_9 | Pages 58 - 58
1 Sep 2019
Hofste A Soer R Hermens H Oosterveld F Groen G
Full Access

Aim. To systematically review the literature and anatomical atlases on LM morphology. Methods. Relevant studies were searched in PubMed (Medline) and Science Direct. Anatomical atlases were retrieved from multiple university libraries and online. Included atlases and studies were assessed at five items: visuals present(y/n), quality of visuals(in-/sufficient), labelling of multifidus (y/n), clear description of region of interest(y/n), description of plane has been described(y/n). This risk of bias assessment tool was developed to assess the quality of description of anatomy, since existing risk of bias tables have only been developed to assess the methodology of studies. Results. In total 69 studies and 19 anatomical atlases were included. Studies. - 52 of 69 studies, LM was described as a superficial muscle at the levels L4 – S1. Others presented the LM as deep intrinsic muscle. - Most used methods: MRI, ultrasound imaging or drawings. - 32 of 69 studies scored a total of five points at the risk of bias assessment, which means low risk of bias. Anatomical atlases. - LM is shown as a deep intrinsic back muscle covered by the erector spinae and fascia thoracolumbalis. - Most anatomical atlases (8/19) had a score of four points at the risk of bias assessment. Conclusion. Anatomy atlases reported different LM morphology compared to anatomical studies. Even between studies, there appears to be inconsistent reporting in LM anatomy. Variation in research methods that are used for measuring LM morphology could influence variation in describing and presenting LM morphology. Standardization of research methodology is recommended in order to compare studies. No conflicts of interest. Sources of Funding: SIA RAAK-Publiek


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_11 | Pages 6 - 6
1 Sep 2021
Sriram S Hamdan T Al-Ahmad S Ajayi B Fenner C Fragkakis A Bishop T Bernard J Lui DF
Full Access

Thoracolumbar injury classification systems are not used or researched extensively in paediatric population yet. This systematic review aims to explore the validity and reliability of the two main thoracolumbar injury classification systems in the paediatric population (age ≤ 18). It also aims to explore the transferability of adult classification systems to paediatrics. The Thoracolumbar Injury Classification System (TLICS) published in 2005 and the AO Spine published in 2013 were assessed in this paper because they both provide guidance for the assessment of the severity of an injury and recommend management strategies. A literature search was conducted on the following databases: Medline, EMBASE, Ovid during the period November 2020 to December 2020 for studies looking at the reliability and validity of the TLICS and AO Spine classification systems in paediatric population. Data on validity (to what extent TLICS/ AO Spine recommended treatment matched the actual treatment) and reliability (inter-rater and intra-rater reliability) was extracted. There is an “almost perfect validity” for TLICS. There is a “strong association” between the validity of TLICS and AO Spine. The intra-rater reliability is “moderate” for TLICS and “substantial” for AO Spine. The intra-rater reliability is “substantial” for TLICS and “almost perfect” for AO Spine. The six studies show a good overall validity and reliability for the application of TLICS and AO Spine in pediatric thoracolumbar fractures. However, implication of treatment and anatomical differences of the growing spine should be explored in detail. Therefore, AO Spine can be used in absence of any other classification system for paediatrics


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_11 | Pages 13 - 13
1 Sep 2021
Patankar A Fragkakis EM Papadakos N Fenner C Ajayi B Beharry N Lupu C Bernard J Bishop T Lui DF
Full Access

Introduction. Degenerative spondylosis (DS) represents a challenging condition to diagnose and treat. There are multiple modalities to investigate DS including X-ray, MRI and CT, but symptoms may not be equivocal to DS to support the clinical findings. The investigation of metastases commonly utilises SPECT/CT for identification of areas of increased osteoblastic activity to denote disease. The aim of the study was to analyse the prevalence of asymptomatic DS in a consecutive hospital cohort of oncology patients who had SPECT/CT for investigation of metastases. Methods. Oncology patients who underwent SPECT/CT at St. George's Hospital were analysed between 2015–2019. Exclusion criteria: back pain, inflammatory disorders, metastases, trauma, infection. Radiology reports were examined for DS and anatomical distribution of tracer uptake. Results. A total of 1182 patients had a Whole-Body SPECT CT used for the spinal analysis. After exclusions (age >80 [n=260], non-cancer [n=318], back pain [n=72]), 522 reports with cancer were utilised. Mean age was 65 (4–80). Age and distribution of DS are given in the table. Conclusion. The prevalence of radiological asymptomatic DS is prevalent in large proportions of patients without back pain, and its incidence increases with age. Approximately 60% of 60 year old and 70% of 70 years old patients have asymptomatic DS in the lumbosarcal region. We conclude that SPECT/CT will detect radiographic degenerative spondylosis in an asymptomatic hospital cohort and this prevalence increase with age. Therefore, this modality of imaging must be utilised with caution when investigating potential pain generators. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_11 | Pages 12 - 12
1 Sep 2021
Rose L Williams R Al-Ahmed S Fenner C Fragkakis A Lupu C Ajayi B Bernard J Bishop T Papadakos N Lui DF
Full Access

Background. The advent of EOS imaging has offered clinicians the opportunity to image the whole skeleton in the anatomical standing position with a smaller radiation dose than standard spine roentgenograms. It is known as the fifth modality of imaging. Current NICE guidelines do not recommend EOS scans over x-rays citing: “The evidence indicated insufficient patient benefit in terms of radiation dose reduction and increased throughput to justify its cost”. Methods. We retrospectively reviewed 103 adult and 103 paediatric EOS scans of standing whole spines including shoulders and pelvis for those undergoing investigation for spinal deformity in a tertiary spinal centre in the UK. We matched this against a retrospective control group of 103 adults and 103 children who underwent traditional roentgenograms whole spine imaging at the same centre during the same timeframe. We aimed to compare the average radiation dose of AP and lateral images between the two modalities. We utilised a validated lifetime risk of cancer calculator (. www.xrayrisk.com. ) to estimate the additional mean risk per study. Results. In the Adult EOS Group (AEG) the mean estimated effective dose of AP was 0.08 mSv (0.04–0.15) and Lateral 0.06 mSv (0.03–0.14). Conversely in the Adult Roentgenograms Group (ARG) the mean AP was 0.49 mSv (0.15–1.88) and Lateral was 0.29 mSv (0.07–1.20). In the Paediatric EOS Group (PEG): the mean dose of AP was 0.07 mSv (0.02–0.21) and Lateral 0.04 mSv (0.02–0.11). Conversely Paediatric Roentgenograms Group (PRG) had a mean dose in AP of 0.37 mSv (0.03–5.92) and in lateral of 0.17 mSv (0.03–0.44). The percentage differences were: ARG:AES AP 613%, ARG:AES Lat 483%, PPG:PEG AP 529%, PRG:PEG Lat 425%. Mean difference 513%. The additional lifetime cancer risk for AEG was 1 in 176056 for males and 1 in 138696 for females, compared to ARG 1 in 31596 for males and 1 in 24894 for females. In PEG that was 1 in 58207 for boys and 1 in 33367 for girls, compared to PRG 1 in 11860 for boys and 1 in 6797 in girls. Differences in additional lifetime risk of cancer per scan: ARG:AES Male 557%, Female 557%, PRG:PEG Male 491%, Females 491%. Conclusion. Standard plain film imaging of the whole spine requires approximately five-times higher doses of radiation compared to dual planar EOS scans. This carries a significant impact when considering the need for repeat imaging on additional lifetime malignancy risk in both children and adults. There is approximately 5-fold increase in risk of cancer for all groups with roentgenograms over EOS. We directly challenge the NICE guidance and recommend EOS dual planar imaging in favour of plane roentgenograms for investigation of spinal deformity


Bone & Joint Open
Vol. 4, Issue 8 | Pages 573 - 579
8 Aug 2023
Beresford-Cleary NJA Silman A Thakar C Gardner A Harding I Cooper C Cook J Rothenfluh DA

Aims

Symptomatic spinal stenosis is a very common problem, and decompression surgery has been shown to be superior to nonoperative treatment in selected patient groups. However, performing an instrumented fusion in addition to decompression may avoid revision and improve outcomes. The aim of the SpInOuT feasibility study was to establish whether a definitive randomized controlled trial (RCT) that accounted for the spectrum of pathology contributing to spinal stenosis, including pelvic incidence-lumbar lordosis (PI-LL) mismatch and mobile spondylolisthesis, could be conducted.

Methods

As part of the SpInOuT-F study, a pilot randomized trial was carried out across five NHS hospitals. Patients were randomized to either spinal decompression alone or spinal decompression plus instrumented fusion. Patient-reported outcome measures were collected at baseline and three months. The intended sample size was 60 patients.


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 53 - 61
1 Jan 2024
Buckland AJ Huynh NV Menezes CM Cheng I Kwon B Protopsaltis T Braly BA Thomas JA

Aims

The aim of this study was to reassess the rate of neurological, psoas-related, and abdominal complications associated with L4-L5 lateral lumbar interbody fusion (LLIF) undertaken using a standardized preoperative assessment and surgical technique.

Methods

This was a multicentre retrospective study involving consecutively enrolled patients who underwent L4-L5 LLIF by seven surgeons at seven institutions in three countries over a five-year period. The demographic details of the patients and the details of the surgery, reoperations and complications, including femoral and non-femoral neuropraxia, thigh pain, weakness of hip flexion, and abdominal complications, were analyzed. Neurological and psoas-related complications attributed to LLIF or posterior instrumentation and persistent symptoms were recorded at one year postoperatively.


Bone & Joint Research
Vol. 12, Issue 3 | Pages 189 - 198
7 Mar 2023
Ruiz-Fernández C Ait Eldjoudi D González-Rodríguez M Cordero Barreal A Farrag Y García-Caballero L Lago F Mobasheri A Sakai D Pino J Gualillo O

Aims

CRP is an acute-phase protein that is used as a biomarker to follow severity and progression in infectious and inflammatory diseases. Its pathophysiological mechanisms of action are still poorly defined. CRP in its pentameric form exhibits weak anti-inflammatory activity. The monomeric isoform (mCRP) exerts potent proinflammatory properties in chondrocytes, endothelial cells, and leucocytes. No data exist regarding mCRP effects in human intervertebral disc (IVD) cells. This work aimed to verify the pathophysiological relevance of mCRP in the aetiology and/or progression of IVD degeneration.

Methods

We investigated the effects of mCRP and the signalling pathways that are involved in cultured human primary annulus fibrosus (AF) cells and in the human nucleus pulposus (NP) immortalized cell line HNPSV-1. We determined messenger RNA (mRNA) and protein levels of relevant factors involved in inflammatory responses, by quantitative real-time polymerase chain reaction (RT-qPCR) and western blot. We also studied the presence of mCRP in human AF and NP tissues by immunohistochemistry.


The Bone & Joint Journal
Vol. 105-B, Issue 4 | Pages 431 - 438
15 Mar 2023
Vendeuvre T Tabard-Fougère A Armand S Dayer R

Aims

This study aimed to evaluate rasterstereography of the spine as a diagnostic test for adolescent idiopathic soliosis (AIS), and to compare its results with those obtained using a scoliometer.

Methods

Adolescents suspected of AIS and scheduled for radiographs were included. Rasterstereographic scoliosis angle (SA), maximal vertebral surface rotation (ROT), and angle of trunk rotation (ATR) with a scoliometer were evaluated. The area under the curve (AUC) from receiver operating characteristic (ROC) plots were used to describe the discriminative ability of the SA, ROT, and ATR for scoliosis, defined as a Cobb angle > 10°. Test characteristics (sensitivity and specificity) were reported for the best threshold identified using the Youden method. AUC of SA, ATR, and ROT were compared using the bootstrap test for two correlated ROC curves method.


The Bone & Joint Journal
Vol. 105-B, Issue 4 | Pages 400 - 411
15 Mar 2023
Hosman AJF Barbagallo G van Middendorp JJ

Aims

The aim of this study was to determine whether early surgical treatment results in better neurological recovery 12 months after injury than late surgical treatment in patients with acute traumatic spinal cord injury (tSCI).

Methods

Patients with tSCI requiring surgical spinal decompression presenting to 17 centres in Europe were recruited. Depending on the timing of decompression, patients were divided into early (≤ 12 hours after injury) and late (> 12 hours and < 14 days after injury) groups. The American Spinal Injury Association neurological (ASIA) examination was performed at baseline (after injury but before decompression) and at 12 months. The primary endpoint was the change in Lower Extremity Motor Score (LEMS) from baseline to 12 months.


The Bone & Joint Journal
Vol. 104-B, Issue 6 | Pages 715 - 720
1 Jun 2022
Dunsmuir RA Nisar S Cruickshank JA Loughenbury PR

Aims

The aim of the study was to determine if there was a direct correlation between the pain and disability experienced by patients and size of their disc prolapse, measured by the disc’s cross-sectional area on T2 axial MRI scans.

Methods

Patients were asked to prospectively complete visual analogue scale (VAS) and Oswestry Disability Index (ODI) scores on the day of their MRI scan. All patients with primary disc herniation were included. Exclusion criteria included recurrent disc herniation, cauda equina syndrome, or any other associated spinal pathology. T2 weighted MRI scans were reviewed on picture archiving and communications software. The T2 axial image showing the disc protrusion with the largest cross sectional area was used for measurements. The area of the disc and canal were measured at this level. The size of the disc was measured as a percentage of the cross-sectional area of the spinal canal on the chosen image. The VAS leg pain and ODI scores were each correlated with the size of the disc using the Pearson correlation coefficient (PCC). Intraobserver reliability for MRI measurement was assessed using the interclass correlation coefficient (ICC). We assessed if the position of the disc prolapse (central, lateral recess, or foraminal) altered the symptoms described by the patient. The VAS and ODI scores from central and lateral recess disc prolapses were compared.


Bone & Joint Research
Vol. 10, Issue 12 | Pages 797 - 806
8 Dec 2021
Chevalier Y Matsuura M Krüger S Traxler H Fleege† C Rauschmann M Schilling C

Aims

Anchorage of pedicle screw rod instrumentation in the elderly spine with poor bone quality remains challenging. Our study aims to evaluate how the screw bone anchorage is affected by screw design, bone quality, loading conditions, and cementing techniques.

Methods

Micro-finite element (µFE) models were created from micro-CT (μCT) scans of vertebrae implanted with two types of pedicle screws (L: Ennovate and R: S4). Simulations were conducted for a 10 mm radius region of interest (ROI) around each screw and for a full vertebra (FV) where different cementing scenarios were simulated around the screw tips. Stiffness was calculated in pull-out and anterior bending loads.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_10 | Pages 18 - 18
1 May 2017
Deane J Papi E Phillips A McGregor A
Full Access

Introduction. Low back pain (LBP) is the top leading global cause of years lived with disability. In order to examine LBP, researchers have typically viewed the spine in isolation. Clinically, it is imperative that the lower limbs are also considered. The aim of this study was to design a holistic and reliable multi-segmental kinematic model of the spine and lower limbs. Method. The spine was modelled according to easily identifiable anatomical landmarks, including upper thoracic (T1-T6), lower thoracic (T7-T12) and lumbar (L1-L5) segments. Pelvis, thigh, shank and foot segments were included. A 10-camera 3D motion capture system was used to track retro-reflective markers, which were used to define each segment of 10 healthy participants as they walked 3 times at a comfortable speed over a 6km walkway. The relative peak angles between each segment were calculated using the Joint Coordinate System convention and Intraclass Correlation Coefficients (ICCs) were used to determine intra-rater and inter-rater reliability (between an experienced clinician and biomechanical scientist). Results. Intra-rater and inter-rater ICCs were good to excellent (0.6–0.99). This implies that the system could be used reliably by one tester or by testers with limited anatomical expertise. Subjective participant reports implied that the system was acceptable and suitable for patient use (average application time of 10 minutes). Conclusion. The ‘Imperial Spinal Model’ is a holistic and reliable multi-segmental model. It is suitable for the kinematic assessment of the spine and could be used to enhance our understanding of a variety of spinal conditions. No conflicts of interest. Funding: Janet Deane is funded by an Allied Health Professional Doctoral Fellowship awarded by Arthritis Research U.K. (ARUK). Enrica Papi is funded by the National Centre of Excellence for Musculoskeletal Health and Work funded by ARUK and the Medical Research Council


The Bone & Joint Journal
Vol. 103-B, Issue 7 | Pages 1301 - 1308
1 Jul 2021
Sugiura K Morimoto M Higashino K Takeuchi M Manabe A Takao S Maeda T Sairyo K

Aims

Although lumbosacral transitional vertebrae (LSTV) are well-documented, few large-scale studies have investigated thoracolumbar transitional vertebrae (TLTV) and spinal numerical variants. This study sought to establish the prevalence of numerical variants and to evaluate their relationship with clinical problems.

Methods

A total of 1,179 patients who had undergone thoracic, abdominal, and pelvic CT scanning were divided into groups according to the number of thoracic and lumbar vertebrae, and the presence or absence of TLTV or LSTV. The prevalence of spinal anomalies was noted. The relationship of spinal anomalies to clinical symptoms (low back pain, Japanese Orthopaedic Association score, Roland-Morris Disability Questionnaire) and degenerative spondylolisthesis (DS) was also investigated.


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 971 - 975
1 May 2021
Hurley P Azzopardi C Botchu R Grainger M Gardner A

Aims

The aim of this study was to assess the reliability of using MRI scans to calculate the Spinal Instability Neoplastic Score (SINS) in patients with metastatic spinal cord compression (MSCC).

Methods

A total of 100 patients were retrospectively included in the study. The SINS score was calculated from each patient’s MRI and CT scans by two consultant musculoskeletal radiologists (reviewers 1 and 2) and one consultant spinal surgeon (reviewer 3). In order to avoid potential bias in the assessment, MRI scans were reviewed first. Bland-Altman analysis was used to identify the limits of agreement between the SINS scores from the MRI and CT scans for the three reviewers.


Bone & Joint Open
Vol. 2, Issue 7 | Pages 540 - 544
19 Jul 2021
Jensen MM Milosevic S Andersen GØ Carreon L Simony A Rasmussen MM Andersen MØ

Aims

The aim of this study was to identify factors associated with poor outcome following coccygectomy on patients with chronic coccydynia and instability of the coccyx.

Methods

From the Danish National Spine Registry, DaneSpine, 134 consecutive patients were identified from a single centre who had coccygectomy from 2011 to 2019. Patient demographic data and patient-reported outcomes, including pain measured on a visual analogue scale (VAS), Oswestry Disability Index (ODI), EuroQol five-dimension five-level questionnaire, and 36-Item Short-Form Health Survey questionnaire (SF-36) were obtained at baseline and at one-year follow-up. Patient satisfaction was obtained at follow-up. Regression analysis, including age, sex, smoking status, BMI, duration of symptoms, work status, welfare payment, preoperative VAS, ODI, and SF-36 was performed to identify factors associated with dissatisfaction with results at one-year follow-up.