Advertisement for orthosearch.org.uk
Results 1 - 20 of 307
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 56 - 56
7 Aug 2023
Nicholls K Wilcocks K Shean K Anderson J Matthews A Vachtsevanos L
Full Access

Abstract. Introduction. Compared to the standard Tomofix plate, the anatomical Tomofix medial high tibial (MHT) plate has been shown to improve anatomical fit and post correction tibial contour, following high tibial osteotomy (HTO). Clinical data on surgical complications, osteotomy union rates and survivorship with the anatomical Tomofix MHT plate however remain limited. This study reports mid-term results of HTO surgery, using the anatomical Tomofix MHT plate. Methods. All patients undergoing HTO surgery using the anatomical Tomofix MHT plate between 2017 and 2022 were included in the study. Data on complications, osteotomy union rates and survivorship were collected prospectively and retrospectively analysed. Results. 78 HTO procedures were performed using the anatomical Tomofix plate in 68 patients. Follow-up ranged between 6 weeks and 5 years. Postoperative complications included 5 hinge fractures that united without further intervention, 1 deep vein thrombus and 1 subclinical pulmonary embolism. There were no wound problems and no returns to theatre, other than for planned removal of metalwork at 1 year. All osteotomies united with no loss of correction. Only 1 HTO was successfully revised to a partial medial knee replacement 2.5 years following osteotomy. The 5-year survivorship was 98.7%. Conclusion. The anatomical Tomofix MHT plate achieves excellent biomechanical stability and union rates in HTO surgery, with minimal complications and excellent mid-term HTO survivorship


Bone & Joint Open
Vol. 3, Issue 10 | Pages 767 - 776
5 Oct 2022
Jang SJ Kunze KN Brilliant ZR Henson M Mayman DJ Jerabek SA Vigdorchik JM Sculco PK

Aims. Accurate identification of the ankle joint centre is critical for estimating tibial coronal alignment in total knee arthroplasty (TKA). The purpose of the current study was to leverage artificial intelligence (AI) to determine the accuracy and effect of using different radiological anatomical landmarks to quantify mechanical alignment in relation to a traditionally defined radiological ankle centre. Methods. Patients with full-limb radiographs from the Osteoarthritis Initiative were included. A sub-cohort of 250 radiographs were annotated for landmarks relevant to knee alignment and used to train a deep learning (U-Net) workflow for angle calculation on the entire database. The radiological ankle centre was defined as the midpoint of the superior talus edge/tibial plafond. Knee alignment (hip-knee-ankle angle) was compared against 1) midpoint of the most prominent malleoli points, 2) midpoint of the soft-tissue overlying malleoli, and 3) midpoint of the soft-tissue sulcus above the malleoli. Results. A total of 932 bilateral full-limb radiographs (1,864 knees) were measured at a rate of 20.63 seconds/image. The knee alignment using the radiological ankle centre was accurate against ground truth radiologist measurements (inter-class correlation coefficient (ICC) = 0.99 (0.98 to 0.99)). Compared to the radiological ankle centre, the mean midpoint of the malleoli was 2.3 mm (SD 1.3) lateral and 5.2 mm (SD 2.4) distal, shifting alignment by 0.34. o. (SD 2.4. o. ) valgus, whereas the midpoint of the soft-tissue sulcus was 4.69 mm (SD 3.55) lateral and 32.4 mm (SD 12.4) proximal, shifting alignment by 0.65. o. (SD 0.55. o. ) valgus. On the intermalleolar line, measuring a point at 46% (SD 2%) of the intermalleolar width from the medial malleoli (2.38 mm medial adjustment from midpoint) resulted in knee alignment identical to using the radiological ankle centre. Conclusion. The current study leveraged AI to create a consistent and objective model that can estimate patient-specific adjustments necessary for optimal landmark usage in extramedullary and computer-guided navigation for tibial coronal alignment to match radiological planning. Cite this article: Bone Jt Open 2022;3(10):767–776


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 47 - 47
1 Jul 2022
Miyaji N Holthof S Willinger L Athwal K Ball S Williams A Amis A
Full Access

Abstract. Introduction. MCL injuries often occur concurrently with ACL rupture – most noncontact ACL injuries occur in valgus and external rotation (ER) - and conservative MCL treatment leads to increased rate of ACL reconstruction failure. There has been little work developing effective MCL reconstructions. Methods. Cadaveric work measured MCL attachments by digitisation and radiographically, relating them to anatomical landmarks. The isometry of the superficial and deep MCL (sMCL and dMCL) and posterior oblique ligament (POL) was measured using fine sutures led to displacement transducers. Contributions to stability (restraint) were measured in a robotic testing system. Two MCL reconstructions were designed and tested: 3-strand reconstruction (sMCL+dMCL+POL), and 2-strand method (sMCL+dMCL) addressing anteromedial rotatory instability (AMRI). The resulting stability was measured in a kinematics test rig, and compared to the ‘anatomic’ sMCL+POL reconstruction of LaPrade. Results. The sMCL was isometric, centred on the medial epicondyle, and the primary restraint of valgus. The dMCL elongated rapidly in ER, and was the primary restraint of ER near knee extension. The POL slackened rapidly with flexion and only stabilised the knee near extension. With sMCL+dMCL+POL deficiency (‘grade 3’), the 2-strand AM reconstruction restored all stability measures to native, apart from internal rotation. The 3-strand reconstruction restored all stability measures to native. The LaPrade reconstruction did not control ER, lacking a dMCL graft, or valgus in flexion, being anisometric. Conclusions. This work has revealed the importance of the dMCL in stabilising AMRI as part of anatomical MCL reconstruction, with the sMCL restraining valgus


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 32 - 32
7 Aug 2023
Nicholls K Petsiou D Wilcocks K Shean K Anderson J Vachtsevanos L
Full Access

Abstract. Introduction. Surgery in patients with high body mass index (BMI) is more technically challenging and associated with increased complications post-operatively. Inferior clinical and functional mid-term results for high BMI patients undergoing high tibial osteotomy (HTO) relative to normal weight patients have been reported. This study discusses the clinical, radiological and functional outcomes of HTO surgery in patients with a high BMI. Method. This is a retrospective study on patients undergoing HTO surgery using the Tomofix anatomical MHT plate between 2017 and 2022, with follow-up period of up to 5 years. The cohort was divided: non-obese (BMI <30 kg/m2) and obese (BMI>30 kg/m2). Pre and post operative functional scores were collected: Oxford Knee Score (OKS), EuroQol-5D and Tegner. Complications, plate survivorship and Mikulicz point recorded. Results. 32 HTO procedures; 19 patients BMI <30 (average 27.0) and 14 patients BMI >30 (average 36.1). In BMI<30 cohort, one readmission for investigation of venous thromboembolism, doppler negative; two complications: hinge fracture and stitch abscess. The five year survivorship of the plate was 100%. In BMI>30 cohort, one readmission for pulmonary embolism; one complication: hinge fracture. The 5 year survivorship of the plate was 93%, 1 conversion to unicompartmental knee replacement. The average OKS improvement was 17 and 18 for BMI <30 and >30 respectively. Mikulicz point change was identical. Conclusion. The Tomofix anatomical MHT plate achieves good outcomes and minimal complications irrespective of BMI. Reduced plate survivorship, thus earlier conversion may be required in the obese, however higher cohort numbers are needed to confirm this


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 8 | Pages 1032 - 1038
1 Aug 2008
Cobb JP Dixon H Dandachli W Iranpour F

The rotational alignment of the tibia is an unresolved issue in knee replacement. A poor functional outcome may be due to malrotation of the tibial component. Our aim was to find a reliable method for positioning the tibial component in knee replacement. CT scans of 19 knees were reconstructed in three dimensions and orientated vertically. An axial plane was identified 20 mm below the tibial spines. The centre of each tibial condyle was calculated from ten points taken round the condylar cortex. The tibial tubercle centre was also generated as the centre of the circle which best fitted eight points on the outside of the tubercle in an axial plane at the level of its most prominent point. The derived points were identified by three observers with errors of 0.6 mm to 1 mm. The medial and lateral tibial centres were constant features (radius 24 mm (. sd. 3), and 22 mm (. sd. 3), respectively). An anatomical axis was created perpendicular to the line joining these two points. The tubercle centre was found to be 20 mm (. sd. 7) lateral to the centre of the medial tibial condyle. Compared with this axis, an axis perpendicular to the posterior condylar axis was internally rotated by 6° (. sd. 3). An axis based on the tibial tubercle and the tibial spines was also internally rotated by 5° (. sd. 10). Alignment of the knee when based on this anatomical axis was more reliable than either the posterior surfaces or any axis involving the tubercle which was the least reliable landmark in the region


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 285 - 293
1 Mar 2018
Nakamae A Adachi N Deie M Ishikawa M Nakasa T Ikuta Y Ochi M

Aims. To investigate the risk factors for progression of articular cartilage damage after anatomical anterior cruciate ligament (ACL) reconstruction. Patients and Methods. A total of 174 patients who underwent second-look arthroscopic evaluation after anatomical ACL reconstruction were enrolled in this study. The graded condition of the articular cartilage at the time of ACL reconstruction was compared with that at second-look arthroscopy. Age, gender, body mass index (BMI), ACL reconstruction technique, meniscal conditions, and other variables were assessed by regression analysis as risk factors for progression of damage to the articular cartilage. Results. In the medial compartment, multivariable logistic regression analysis indicated that partial medial meniscectomy (odds ratio (OR) 6.82, 95% confidence interval (CI) 2.11 to 22.04, p = 0.001), pivot-shift test grade at the final follow-up (OR 3.53, CI 1.39 to 8.96, p = 0.008), BMI (OR 1.15, CI 1.03 to 1.28, p = 0.015) and medial meniscal repair (OR 3.19, CI 1.24 to 8.21, p = 0.016) were significant risk factors for progression of cartilage damage. In the lateral compartment, partial lateral meniscectomy (OR 10.94, CI 4.14 to 28.92, p < 0.001) and side-to-side differences in anterior knee laxity at follow-up (OR 0.63, p = 0.001) were significant risk factors. Conclusion. Partial meniscectomy was found to be strongly associated with the progression of articular cartilage damage despite r anatomical ACL reconstruction. Cite this article: Bone Joint J 2018;100-B:285–93


The Bone & Joint Journal
Vol. 97-B, Issue 3 | Pages 324 - 328
1 Mar 2015
Boddu CK Arif SK Hussain MM Sankaranarayanan S Hameed S Sujir PR

Graft-tunnel mismatch of the bone-patellar tendon-bone (BPTB) graft is a major concern during anatomical anterior cruciate ligament (ACL) reconstruction if the femoral tunnel is positioned using a far medial portal technique, as the femoral tunnel tends to be shorter compared with that positioned using a transtibial portal technique. This study describes an accurate method of calculating the ideal length of bone plugs of a BPTB graft required to avoid graft–tunnel mismatch during anatomical ACL reconstruction using a far medial portal technique of femoral tunnel positioning. Based on data obtained intra-operatively from 60 anatomical ACL reconstruction procedures, we calculated the length of bone plugs required in the BPTB graft to avoid graft–tunnel mismatch. When this was prevented in all the 60 cases, we found that the mean length of femoral bone plug that remained in contact with the interference screw within the femoral tunnel was 14 mm (12 to 22) and the mean length of tibial bone plug that remained in contact with the interference screw within the tibial tunnel was 23 mm (18 to 28). These results were used to validate theoretical formulae developed to predict the required length of bone plugs in BPTB graft during anatomical ACL reconstruction using a far medial portal technique. Cite this article: Bone Joint J 2015;97-B:324–8


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 6 | Pages 745 - 749
1 Jun 2009
Ritter MA

The long-term success of total knee replacement is multifactorial, including factors relating to the patient, the operation and the implant. The purpose of this study was to examine the 20-year survival of the cemented Anatomical Graduated Component (AGC) total knee replacement. Between 1983 and 2004, 7760 of these were carried out at our institution. Of these, 6726 knees which received the non-modular metal-backed tibial component with compression-moulded polyethylene and had a minimum two-year follow-up were available for study. In all, 36 knees were followed over 20 years with a survival of the tibial and femoral components together of 97.8% (95% confidence interval (CI) 0.9851 to 0.9677), with no implants being revised for polyethylene wear or osteolysis. Age > 70 was associated with increased survival (99.6%, 95% CI 99.0 to 99.8) (p < 0.0001) but pre-operative valgus alignment reduced survival (95.1%, 95% CI 90.0 to 97.6) (p = 0.0056). Age < 55 (p = 0.129), pre-operative varus alignment (p = 0.707), osteonecrosis (p = 0.06), rheumatoid arthritis (p = 0.247), and gender (p = 0.666) were not statistically associated with failure. We attribute the success of the AGC implant to its relatively unconstrained articular geometry and the durability of a non-modular metal-backed tibial component with compression moulded polyethylene


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 40 - 40
1 Mar 2012
Spalding T Thompson P Clewer G Bird J Smith N Dhillon M
Full Access

Hypothesis. Recent advances in understanding of ACL insertional anatomy has led to new concepts of anatomical positioning of tunnels for ACL reconstruction. Femoral tunnel position has been defined in terms of the lateral intercondylar ridge and the bifurcate ridge but these can be difficult to identify at surgery. Measurements of the lateral wall either using C-arm x-ray control or specific arthroscopic rulers have also been advocated. Method. 30 patients undergoing ACL reconstruction before and after introduction of a new anatomical technique of ACL reconstruction were evaluated using 3D CT scan imaging with cut away views of the lateral aspect of the femoral notch and the radiological quadrant grid. In the new technique, with the knee at 90 degrees flexion, the femoral tunnel was centred 50% from deep to shallow as seen from the medial portal (Group A). Group B consisted of patients where the femoral tunnel was drilled through the antero-medial portal and offset from the posterior wall using a 5mm jig. Results. Ridges were identifiable in only 76% of scans. All tunnels in Group A (anatomical technique) were found to be below (posterior to) the lateral intercondylar (residents) ridge and were within 10% of the optimal position as defined by the Grid method on x-ray. No femoral tunnels in Group B meet anatomical criteria and were malpositioned by a mean of 5mm. Conclusion. We believe 3D CT scan imaging with cut away views of the femoral tunnel is a useful and accurate way of describing tunnel position, and that this technique will be valuable in validating new surgical techniques. According to this CT scan analysis the new anatomical technique correctly placed the femoral tunnel. This work forms the basis of a subsequent randomised trial of techniques in relation to clinical outcome


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 46 - 46
1 Mar 2012
H HS Suhani H Lydia Q Nair N Khanduja V
Full Access

Aim. The aim of this study was to study the course of the infra-patellar branch of the saphenous nerve (IPBSN) and describe its anatomical variations and relations. Materials and Methods. Twenty-eight formalin-fixed cadaver lower extremity specimens were methodically dissected in the University Department of Anatomy. Dissection included identifying the saphenous nerve and tracing it distally till it pierced the deep fascia between the tendons of gracilis and sartorius. At this point, the saphenous nerve gave a branch that pierced the sartorius and became subcutaneous, known as the infrapatellar branch. The association of the nerve trunk with the sartorius muscle in terms of whether it originated above it, below it or pierced through it was studied. Following this the nerve was dissected along its course distally to the point of its termination where it gave one to three branches. The relationship of the point of termination of the IPBSN with bony surface landmarks like the medial border of the patella, the apex of the patella and the tibial tuberosity were also studied. The distance of the trunk from medial margin of patella was measured. Conclusions. The anatomy of the IPBSN along with its branches is quite variable and a thorough knowledge of the same is essential to any knee surgeon to avoid injury to this structure


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1462 - 1465
1 Nov 2007
Roberts VI Mereddy PKR Donnachie NJ Hakkalamani S

The emergence of minimally-invasive total knee replacement (TKR) has led to the refinement of several surgical approaches, including the quadriceps-sparing and sub-vastus. There is some disagreement as to the precise definition of the term ‘minimally-invasive’, especially in regard to the preservation of vastus medialis obliquus (VMO). It is known that the termination of VMO is variable and may make these approaches difficult. We have attempted to assess the factors influencing the insertion of VMO and the impact which they have on the approach for TKR.

The MR scans of 198 knees were examined to assess the variation in the insertion of VMO in relation to the patella and the effect of variables such as age, gender and the presence of concurrent osteoarthritis of the knee on the insertion.

Our findings showed that both age and the presence of osteoarthritis were contributing factors to changes in the level of insertion of VMO. Therefore, not all capsular incisions which extend proximal to the midpole of the patella will violate the quadriceps tendon.


The Bone & Joint Journal
Vol. 95-B, Issue 10 | Pages 1354 - 1358
1 Oct 2013
Singh G Tan JH Sng BY Awiszus F Lohmann CH Nathan SS

The optimal management of the tibial slope in achieving a high flexion angle in posterior-stabilised (PS) total knee replacement (TKR) is not well understood, and most studies evaluating the posterior tibial slope have been conducted on cruciate-retaining TKRs. We analysed pre- and post-operative tibial slope differences, pre- and post-operative coronal knee alignment and post-operative maximum flexion angle in 167 patients undergoing 209 TKRs. The mean pre-operative posterior tibial slope was 8.6° (1.3° to 17°) and post-operatively it was 8.0° (0.1° to 16.7°). Multiple linear regression analysis showed that the absolute difference between pre- and post-operative tibial slope (p < 0.001), post-operative coronal alignment (p = 0.02) and pre-operative range of movement (p < 0.001) predicted post-operative flexion. The variance of change in tibial slope became larger as the post-operative maximum flexion angle decreased. The odds ratio of having a post-operative flexion angle < 100° was 17.6 if the slope change was > 2°. Our data suggest that recreation of the anatomical tibial slope appears to improve maximum flexion after posterior-stabilised TKR, provided coronal alignment has been restored.

Cite this article: Bone Joint J 2013;95-B:1354–8.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 5 - 5
1 Mar 2012
Cockshott S Adams D Carter S Jeys L Pynsent P
Full Access

We prospectively reviewed 2440 Cemented Anantomical (side specific) AGC total knee replacements performed on 2074 patients between 2002 and 2008 in our unit. The surgery was performed by a number of surgeons, both Consultant and Trainee grades. 1357 underwent PCL sacrificing surgery with implantation of Posterior Stabilised Femoral Implant (Cam and Grove) and 1083 underwent PCL retaining surgery with implantation of a Non-Stabilised Femoral Implant. The mean age at date of surgery for Posterior Stabilised prosthesis was 69 years (range 23-94) and Non-Posterior Stabilised prosthesis was 70 (range 33-97) with no significant difference p< 0.05 (C.I 95%). Follow up at present mean 4 years (range 1-6 years).

11 patients underwent secondary patella resurfaced for anterior knee pain at a mean of 1.5 years following the index procedure (range 0.5-4.1 years) with 6 patients reporting a marked improvement in anterior knee pain post operatively. 3 patients underwent removal of patella buttons for symptomatic loosening at a mean of 2.7 years follow index procedure.

A total of 17 patients underwent a revision of either tibial or femoral components (0.7%). Indications for revision were infection in 11 patients, gross instability in 1 patient, periprosthetic fracture in 1 patient, persistent stiffness in 1 patient. 3 patients underwent revision for symptomatic loosening of the tibial component at a mean of 2.9 years (range 1.1-4.0).

These short to medium term results for the Anatomic AGC total knee replacement agree with published results from other centres.


Bone & Joint Open
Vol. 5, Issue 2 | Pages 101 - 108
6 Feb 2024
Jang SJ Kunze KN Casey JC Steele JR Mayman DJ Jerabek SA Sculco PK Vigdorchik JM

Aims. Distal femoral resection in conventional total knee arthroplasty (TKA) utilizes an intramedullary guide to determine coronal alignment, commonly planned for 5° of valgus. However, a standard 5° resection angle may contribute to malalignment in patients with variability in the femoral anatomical and mechanical axis angle. The purpose of the study was to leverage deep learning (DL) to measure the femoral mechanical-anatomical axis angle (FMAA) in a heterogeneous cohort. Methods. Patients with full-limb radiographs from the Osteoarthritis Initiative were included. A DL workflow was created to measure the FMAA and validated against human measurements. To reflect potential intramedullary guide placement during manual TKA, two different FMAAs were calculated either using a line approximating the entire diaphyseal shaft, and a line connecting the apex of the femoral intercondylar sulcus to the centre of the diaphysis. The proportion of FMAAs outside a range of 5.0° (SD 2.0°) was calculated for both definitions, and FMAA was compared using univariate analyses across sex, BMI, knee alignment, and femur length. Results. The algorithm measured 1,078 radiographs at a rate of 12.6 s/image (2,156 unique measurements in 3.8 hours). There was no significant difference or bias between reader and algorithm measurements for the FMAA (p = 0.130 to 0.563). The FMAA was 6.3° (SD 1.0°; 25% outside range of 5.0° (SD 2.0°)) using definition one and 4.6° (SD 1.3°; 13% outside range of 5.0° (SD 2.0°)) using definition two. Differences between males and females were observed using definition two (males more valgus; p < 0.001). Conclusion. We developed a rapid and accurate DL tool to quantify the FMAA. Considerable variation with different measurement approaches for the FMAA supports that patient-specific anatomy and surgeon-dependent technique must be accounted for when correcting for the FMAA using an intramedullary guide. The angle between the mechanical and anatomical axes of the femur fell outside the range of 5.0° (SD 2.0°) for nearly a quarter of patients. Cite this article: Bone Jt Open 2024;5(2):101–108


The Bone & Joint Journal
Vol. 106-B, Issue 5 | Pages 468 - 474
1 May 2024
d'Amato M Flevas DA Salari P Bornes TD Brenneis M Boettner F Sculco PK Baldini A

Aims. Obtaining solid implant fixation is crucial in revision total knee arthroplasty (rTKA) to avoid aseptic loosening, a major reason for re-revision. This study aims to validate a novel grading system that quantifies implant fixation across three anatomical zones (epiphysis, metaphysis, diaphysis). Methods. Based on pre-, intra-, and postoperative assessments, the novel grading system allocates a quantitative score (0, 0.5, or 1 point) for the quality of fixation achieved in each anatomical zone. The criteria used by the algorithm to assign the score include the bone quality, the size of the bone defect, and the type of fixation used. A consecutive cohort of 245 patients undergoing rTKA from 2012 to 2018 were evaluated using the current novel scoring system and followed prospectively. In addition, 100 first-time revision cases were assessed radiologically from the original cohort and graded by three observers to evaluate the intra- and inter-rater reliability of the novel radiological grading system. Results. At a mean follow-up of 90 months (64 to 130), only two out of 245 cases failed due to aseptic loosening. Intraoperative grading yielded mean scores of 1.87 (95% confidence interval (CI) 1.82 to 1.92) for the femur and 1.96 (95% CI 1.92 to 2.0) for the tibia. Only 3.7% of femoral and 1.7% of tibial reconstructions fell below the 1.5-point threshold, which included the two cases of aseptic loosening. Interobserver reliability for postoperative radiological grading was 0.97 for the femur and 0.85 for the tibia. Conclusion. A minimum score of 1.5 points for each skeletal segment appears to be a reasonable cut-off to define sufficient fixation in rTKA. There were no revisions for aseptic loosening at mid-term follow-up when this fixation threshold was achieved or exceeded. When assessing first-time revisions, this novel grading system has shown excellent intra- and interobserver reliability. Cite this article: Bone Joint J 2024;106-B(5):468–474


Abstract. INTRODUCTION. The anatomic distal femoral locking plate (DF-LCP) has simplified the management of supracondylar femoral fractures with stable knee prostheses. Osteoporosis and comminution seem manageable, but at times, the construct does not permit early mobilization. Considerable soft tissue stripping during open reduction and internal fixation (ORIF) may delay union. Biological plating offsets this disadvantage, minimizing morbidity. Materials. Thirty comminuted periprosthetic supracondylar fractures were operated from October 2010 to August 2016. Fifteen (group A) were treated with ORIF, and fifteen (group B) with closed (biological) plating using the anatomical DF-LCP. Post-operatively, standard rehabilitation protocol was followed in all, with hinged-knee-brace supported physiotherapy. Clinico-radiological follow-up was done at 3 months, 6 months, and then yearly (average duration, 30 months), and time to union, complications, failure rates and function were evaluated. Results. Average time to union was 4.5 months (range, 3–6 months) in group A, and 3.5 months (range, 2.5–5 months) in group B. Primary bone grafting was done in twelve patients (all group A). At final follow-up, all fractures had healed, and all (but two) patients were walking unsupported, with no pain or deformity, with average knee range of motion (ROM) of 90° (range, 55 to 100°). Two patients had superficial infection (group A), two had knee stiffness (group A), one had shortening of 1.5cm (group B) and one had valgus malalignment of 10 degrees (group B). Conclusion. Biological plating in comminuted supracondylar fractures about stable TKA prostheses is an excellent option, may obviate need for bone grafting, and reducing complications


Bone & Joint Research
Vol. 13, Issue 5 | Pages 226 - 236
9 May 2024
Jürgens-Lahnstein JH Petersen ET Rytter S Madsen F Søballe K Stilling M

Aims. Micromotion of the polyethylene (PE) inlay may contribute to backside PE wear in addition to articulate wear of total knee arthroplasty (TKA). Using radiostereometric analysis (RSA) with tantalum beads in the PE inlay, we evaluated PE micromotion and its relationship to PE wear. Methods. A total of 23 patients with a mean age of 83 years (77 to 91), were available from a RSA study on cemented TKA with Maxim tibial components (Zimmer Biomet). PE inlay migration, PE wear, tibial component migration, and the anatomical knee axis were evaluated on weightbearing stereoradiographs. PE inlay wear was measured as the deepest penetration of the femoral component into the PE inlay. Results. At mean six years’ follow-up, the PE wear rate was 0.08 mm/year (95% confidence interval 0.06 to 0.09 mm/year). PE inlay external rotation was below the precision limit and did not influence PE wear. Varus knee alignment did not influence PE wear (p = 0.874), but increased tibial component total translation (p = 0.041). Conclusion. The PE inlay was well fixed and there was no relationship between PE stability and PE wear. The PE wear rate was low and similar in the medial and lateral compartments. Varus knee alignment did not influence PE wear. Cite this article: Bone Joint Res 2024;13(5):226–236


Bone & Joint Open
Vol. 4, Issue 4 | Pages 262 - 272
11 Apr 2023
Batailler C Naaim A Daxhelet J Lustig S Ollivier M Parratte S

Aims. The impact of a diaphyseal femoral deformity on knee alignment varies according to its severity and localization. The aims of this study were to determine a method of assessing the impact of diaphyseal femoral deformities on knee alignment for the varus knee, and to evaluate the reliability and the reproducibility of this method in a large cohort of osteoarthritic patients. Methods. All patients who underwent a knee arthroplasty from 2019 to 2021 were included. Exclusion criteria were genu valgus, flexion contracture (> 5°), previous femoral osteotomy or fracture, total hip arthroplasty, and femoral rotational disorder. A total of 205 patients met the inclusion criteria. The mean age was 62.2 years (SD 8.4). The mean BMI was 33.1 kg/m. 2. (SD 5.5). The radiological measurements were performed twice by two independent reviewers, and included hip knee ankle (HKA) angle, mechanical medial distal femoral angle (mMDFA), anatomical medial distal femoral angle (aMDFA), femoral neck shaft angle (NSA), femoral bowing angle (FBow), the distance between the knee centre and the top of the FBow (DK), and the angle representing the FBow impact on the knee (C’KS angle). Results. The FBow impact on the mMDFA can be measured by the C’KS angle. The C’KS angle took the localization (length DK) and the importance (FBow angle) of the FBow into consideration. The mean FBow angle was 4.4° (SD 2.4; 0 to 12.5). The mean C’KS angle was 1.8° (SD 1.1; 0 to 5.8). Overall, 84 knees (41%) had a severe FBow (> 5°). The radiological measurements showed very good to excellent intraobserver and interobserver agreements. The C’KS increased significantly when the length DK decreased and the FBow angle increased (p < 0.001). Conclusion. The impact of the diaphyseal femoral deformity on the mechanical femoral axis is measured by the C’KS angle, a reliable and reproducible measurement. Cite this article: Bone Jt Open 2023;4(4):262–272


Bone & Joint Open
Vol. 5, Issue 6 | Pages 489 - 498
12 Jun 2024
Kriechling P Bowley ALW Ross LA Moran M Scott CEH

Aims. The purpose of this study was to compare reoperation and revision rates of double plating (DP), single plating using a lateral locking plate (SP), or distal femoral arthroplasty (DFA) for the treatment of periprosthetic distal femur fractures (PDFFs). Methods. All patients with PDFF primarily treated with DP, SP, or DFA between 2008 and 2022 at a university teaching hospital were included in this retrospective cohort study. The primary outcome was revision surgery for failure following DP, SP, or DFA. Secondary outcome measures included any reoperation, length of hospital stay, and mortality. All basic demographic and relevant implant and injury details were collected. Radiological analysis included fracture classification and evaluation of metaphyseal and medial comminution. Results. A total of 111 PDFFs (111 patients, median age 82 years (interquartile range (IQR) 75 to 88), 86% female) with 32 (29%) Su classification 1, 37 (34%) Su 2, and 40 (37%) Su 3 fractures were included. The median follow-up was 2.5 years (IQR 1.2 to 5.0). DP, SP, and DFA were used in 15, 66, and 30 patients, respectively. Compared to SP, patients treated with DP were more likely to have metaphyseal comminution (47% vs 14%; p = 0.009), to be low fractures (47% vs 11%; p = 0.009), and to be anatomically reduced (100% vs 71%; p = 0.030). Patients selected for DFA displayed comparable amounts of medial/metaphyseal comminution as those who underwent DP. At a minimum follow-up of two years, revision surgery for failure was performed in 11 (9.9%) cases at a median of five months (IQR 2 to 9): 0 DP patients (0%), 9 SP (14%), and 2 DFA (6.7%) (p = 0.249). Conclusion. Using a strategy of DP fixation in fractures, where the fracture was low but there was enough distal bone to accommodate locking screws, and where there is metaphyseal comminution, resulted in equivalent survival free from revision or reoperation compared to DFA and SP fixation. Cite this article: Bone Jt Open 2024;5(6):489–498


Bone & Joint Open
Vol. 3, Issue 5 | Pages 383 - 389
1 May 2022
Motesharei A Batailler C De Massari D Vincent G Chen AF Lustig S

Aims. No predictive model has been published to forecast operating time for total knee arthroplasty (TKA). The aims of this study were to design and validate a predictive model to estimate operating time for robotic-assisted TKA based on demographic data, and evaluate the added predictive power of CT scan-based predictors and their impact on the accuracy of the predictive model. Methods. A retrospective study was conducted on 1,061 TKAs performed from January 2016 to December 2019 with an image-based robotic-assisted system. Demographic data included age, sex, height, and weight. The femoral and tibial mechanical axis and the osteophyte volume were calculated from CT scans. These inputs were used to develop a predictive model aimed to predict operating time based on demographic data only, and demographic and 3D patient anatomy data. Results. The key factors for predicting operating time were the surgeon and patient weight, followed by 12 anatomical parameters derived from CT scans. The predictive model based only on demographic data showed that 90% of predictions were within 15 minutes of actual operating time, with 73% within ten minutes. The predictive model including demographic data and CT scans showed that 94% of predictions were within 15 minutes of actual operating time and 88% within ten minutes. Conclusion. The primary factors for predicting robotic-assisted TKA operating time were surgeon, patient weight, and osteophyte volume. This study demonstrates that incorporating 3D patient-specific data can improve operating time predictions models, which may lead to improved operating room planning and efficiency. Cite this article: Bone Jt Open 2022;3(5):383–389