Advertisement for orthosearch.org.uk
Results 1 - 12 of 12
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 54 - 54
1 Sep 2012
Barckman J Baas J Sorensen M Bechtold J Lange J Soballe K
Full Access

Introduction. Hip and knee arthroplasty present surgeons with difficult bone loss. In these cases the use of morselized allograft is a well established way of optimizing early implant fixation. In revisions, the surgical field is potentially infected. The use of allograft bone creates a “dead space” in which the immune system has impaired access, and even a small amount of bacteria may therefore theoretically increase the risk of infection. In vivo studies have shown that allograft bone is suitable as a vehicle of local antibiotic delivery. We hypothesized that the allograft bone could be used as a local antibiotic delivery vehicle without impairing the implant fixation, tested by mechanical push-out. Material and Methods. Following approval of the Institutional Animal Care and use Committee we implanted a cylindrical (10×6 mm) porous-coated Ti implant in each distal femur of 12 dogs observed for 4 weeks. The implants were surrounded by a circumferential gap of 2.5 mm impacted with a standardized volume of morselized allograft. In the two intervention groups, 0.2ml tobramycin solution of high (800mg/ml) and low (200mg/ml) concentration was added to the allograft, respectively. In the control group 0.2ml saline was added to the allograft. ANOVA-test was applied followed by paired t-test where appropriate. A p-value < 0,05 was considered statistically significant. Results. The impregnation of allograft bone revealed a relative decrease in biomechanical fixation. The decrease was higher in the high dose group than in the low dose group. The most extreme difference was a decrease in strength by 18% (P = 0,511), stiffness 15% (P = 0,135) and energy absorption 27% (P = 0,784). Conclusion. The result shows a trend towards a decrease in implant fixation correlating with the antibiotic concentration. Although the results are not statistically significant the use of antibiotic impregnation should be used with caution until further reaserch has been conducted


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 559 - 559
1 Sep 2012
Winkler H
Full Access

Aims. Infections of bone usually require multiple surgery and prolonged periods of treatment. One reason for problems is found in the presence of stationary phase bacteria embedded in biofilms that show increased resistance against conventional antibiotic therapy (up to 1000x MIC). Biofilms adhere to surfaces of avital material making radical debridement a prerequisite for cure. Osseous defects are common in such conditions and need to be addressed. To avoid re-infection high local antbiotic concentrations are necessary. Allograft bone may be impregnated with high loads of antibiotics using a special incubation technique. The resulting antibiotic bone compound (ABC) provides high and long lasting concentrations at the site of infection and is likely to restore bone stock simultaneously. Based on this technology we have developed a new surgical technique. Methods. 42 patients (10–67yrs) with chronic osteitis were included into a prospective study using a standardized protocol. Infection was at the humerus (1x), femur (10x), tibia (29x) or femur+tibia (2x), respectively. Treatment consisted of removal of foreign material, radical sequestrectomy and soft-tissue debridement followed by pressurized lavage. Surfaces of sclerotic bone were trimmed down to vital areas. The remaining osseous defects were filled with ABC, using an impaction technique resulting in complete dead space management. The allograft was impregnated with vancomycin, in cases with mixed pathogens combinations with tobramycin were used. Internal fixation was performed the same time whenever applicable. Sites were drained and closed immediately; rehabilitation did not differ from uninfected procedures. Results. 1 patient died shortly after surgery from cardiac failure. 41 could be followed for a minimum of 2 and a maximum of 6years (mean 3,1years). In 2 patients wound healing was unsatisfactory requiring additional coverage with a muscle flap. 2 patients showed material failure after intramedullary nailing, requiring exchange of the implant. In those cases no sign of infection was present at the time of revision. There were 3 cases with recurrence of infection, all originating from foci not detected during the index operation and becoming apparent between 3 and 12 months after surgery. Two could successfully be revised using the same technique; one refused revision and shows continuing fistulation. Radiological incorporation of allografts appeared as after conventional bone grafting, union of pseudarthroses was achieved between 2 and 6 months after (re-) stabilization. 40 patients (95,2%) were fully weight bearing, painfree and without any sign of infection at the latest follow up. Conclusion. Using antibiotic impregnated allograft bone eradication of pathogens, grafting of defects, dead space management and insertion of osteosynthetic material may be accomplished in a one stage procedure. Since the graft gradually is replaced by healthy own bone improved long term results may be expected as well as improved conditions in the case of another revision. The new technique provides for quick rehabilitation, improved results and markedly reduced costs of treatment in cases of bone infection


The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 157 - 167
1 Jan 2022
Makaram NS Goudie EB Robinson CM

Aims

Open reduction and plate fixation (ORPF) for displaced proximal humerus fractures can achieve reliably good long-term outcomes. However, a minority of patients have persistent pain and stiffness after surgery and may benefit from open arthrolysis, subacromial decompression, and removal of metalwork (ADROM). The long-term results of ADROM remain unknown; we aimed to assess outcomes of patients undergoing this procedure for stiffness following ORPF, and assess predictors of poor outcome.

Methods

Between 1998 and 2018, 424 consecutive patients were treated with primary ORPF for proximal humerus fracture. ADROM was offered to symptomatic patients with a healed fracture at six months postoperatively. Patients were followed up retrospectively with demographic data, fracture characteristics, and complications recorded. Active range of motion (aROM), Oxford Shoulder Score (OSS), and EuroQol five-dimension three-level questionnaire (EQ-5D-3L) were recorded preoperatively and postoperatively.


The Bone & Joint Journal
Vol. 103-B, Issue 3 | Pages 456 - 461
1 Mar 2021
Sasaki G Watanabe Y Yasui Y Nishizawa M Saka N Kawano H Miyamoto W

Aims

To clarify the effectiveness of the induced membrane technique (IMT) using beta-tricalcium phosphate (β-TCP) for reconstruction of segmental bone defects by evaluating clinical and radiological outcomes, and the effect of defect size and operated site on surgical outcomes.

Methods

A review of the medical records was conducted of consecutive 35 lower limbs (30 males and five females; median age 46 years (interquartile range (IQR) 40 to 61)) treated with IMT using β-TCP between 2014 and 2018. Lower Extremity Functional Score (LEFS) was examined preoperatively and at final follow-up to clarify patient-centered outcomes. Bone healing was assessed radiologically, and time from the second stage to bone healing was also evaluated. Patients were divided into ≥ 50 mm and < 50 mm defect groups and into femoral reconstruction, tibial reconstruction, and ankle arthrodesis groups.


The Bone & Joint Journal
Vol. 101-B, Issue 3 | Pages 260 - 265
1 Mar 2019
Lee SH Han SS Yoo BM Kim JW

Aims

The aim of this study was to evaluate the clinical and radiological outcomes of locking plate fixation, with and without an associated fibular strut allograft, for the treatment of displaced proximal humeral fractures in elderly osteoporotic patients.

Patients and Methods

We undertook a retrospective comparison of two methods of fixation, using a locking plate without an associated fibular strut allograft (LP group) and with a fibular allograft (FA group) for the treatment of these fractures. The outcome was assessed for 52 patients in the LP group and 45 in the FA group, with a mean age of 74.3 years (52 to 89), at a mean follow-up of 14.2 months (12 to 19). The clinical results were evaluated using a visual analogue scale (VAS) score for pain, the Constant score, the American Shoulder and Elbow Surgeons (ASES) score, and the range of movement. Radiological results were evaluated using the neck-shaft angle (NSA) and humeral head height (HHH).


The Bone & Joint Journal
Vol. 100-B, Issue 4 | Pages 646 - 651
1 Apr 2018
Attias N Thabet AM Prabhakar G Dollahite JA Gehlert RJ DeCoster TA

Aims

This study reviews the use of a titanium mesh cage (TMC) as an adjunct to intramedullary nail or plate reconstruction of an extra-articular segmental long bone defect.

Patients and Methods

A total of 17 patients (aged 17 to 61 years) treated for a segmental long bone defect by nail or plate fixation and an adjunctive TMC were included. The bone defects treated were in the tibia (nine), femur (six), radius (one), and humerus (one). The mean length of the segmental bone defect was 8.4 cm (2.2 to 13); the mean length of the titanium mesh cage was 8.3 cm (2.6 to 13). The clinical and radiological records of the patients were analyzed retrospectively.


Bone & Joint Research
Vol. 6, Issue 7 | Pages 423 - 432
1 Jul 2017
van der Stok J Hartholt KA Schoenmakers DAL Arts JJC

Objectives

The aim of this systematic literature review was to assess the clinical level of evidence of commercially available demineralised bone matrix (DBM) products for their use in trauma and orthopaedic related surgery.

Methods

A total of 17 DBM products were used as search terms in two available databases: Embase and PubMed according to the Preferred Reporting Items for Systematic Reviews and Meta Analyses statement. All articles that reported the clinical use of a DBM-product in trauma and orthopaedic related surgery were included.


The Bone & Joint Journal
Vol. 98-B, Issue 8 | Pages 1126 - 1131
1 Aug 2016
Shiels SM Cobb RR Bedigrew KM Ritter G Kirk JF Kimbler A Finger Baker I Wenke JC

Aims

Demineralised bone matrix (DBM) is rarely used for the local delivery of prophylactic antibiotics. Our aim, in this study, was to show that a graft with a bioactive glass and DBM combination, which is currently available for clinical use, can be loaded with tobramycin and release levels of antibiotic greater than the minimum inhibitory concentration for Staphylococcus aureus without interfering with the bone healing properties of the graft, thus protecting the graft and surrounding tissues from infection.

Materials and Methods

Antibiotic was loaded into a graft and subsequently evaluated for drug elution kinetics and the inhibition of bacterial growth. A rat femoral condylar plug model was used to determine the effect of the graft, loaded with antibiotic, on bone healing.


The Bone & Joint Journal
Vol. 95-B, Issue 5 | Pages 583 - 597
1 May 2013
Kurien T Pearson RG Scammell BE

We reviewed 59 bone graft substitutes marketed by 17 companies currently available for implantation in the United Kingdom, with the aim of assessing the peer-reviewed literature to facilitate informed decision-making regarding their use in clinical practice. After critical analysis of the literature, only 22 products (37%) had any clinical data. Norian SRS (Synthes), Vitoss (Orthovita), Cortoss (Orthovita) and Alpha-BSM (Etex) had Level I evidence. We question the need for so many different products, especially with limited published clinical evidence for their efficacy, and conclude that there is a considerable need for further prospective randomised trials to facilitate informed decision-making with regard to the use of current and future bone graft substitutes in clinical practice.

Cite this article: Bone Joint J 2013;95-B:583–97.


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 836 - 841
1 Jun 2015
Jónsson BY Mjöberg B

A total of 20 patients with a depressed fracture of the lateral tibial plateau (Schatzker II or III) who would undergo open reduction and internal fixation were randomised to have the metaphyseal void in the bone filled with either porous titanium granules or autograft bone. Radiographs were undertaken within one week, after six weeks, three months, six months, and after 12 months.

The primary outcome measure was recurrent depression of the joint surface: a secondary outcome was the duration of surgery.

The risk of recurrent depression of the joint surface was lower (p < 0.001) and the operating time less (p < 0.002) when titanium granules were used.

The indication is that it is therefore beneficial to use porous titanium granules than autograft bone to fill the void created by reducing a depressed fracture of the lateral tibial plateau. There is no donor site morbidity, the operating time is shorter and the risk of recurrent depression of the articular surface is less.

Cite this article: Bone Joint J 2015; 97-B:836–41


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 820 - 824
1 Jun 2013
Zsoldos CM Basamania CJ Bal GK

Gunshot injuries to the shoulder are rare and difficult to manage. We present a case series of seven patients who sustained a severe shoulder injury to the non-dominant side as a result of a self-inflicted gunshot wound. We describe the injury as ‘suicide shoulder’ caused by upward and outward movement of the gun barrel as the trigger is pulled. All patients were male, with a mean age of 32 years (21 to 48). All were treated at the time of injury with initial repeated debridement, and within four weeks either by hemiarthroplasty (four patients) or arthrodesis (three patients). The hemiarthroplasty failed in one patient after 20 years due to infection and an arthrodesis was attempted, which also failed due to infection. Overall follow-up was for a mean of 26 months (12 to 44). All four hemiarthroplasty implants were removed with no feasible reconstruction ultimately possible, resulting in a poor functional outcome and no return to work. In contrast, all three primary arthrodeses eventually united, with two patients requiring revision plating and grafting. These patients returned to work with a good functional outcome. We recommend arthrodesis rather than replacement as the treatment of choice for this challenging injury.

Cite this article: Bone Joint J 2013;95-B:820–4.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 672 - 678
1 May 2010
Robinson CM Wylie JR Ray AG Dempster NJ Olabi B Seah KTM Akhtar MA

We treated 47 patients with a mean age of 57 years (22 to 88) who had a proximal humeral fracture in which there was a severe varus deformity, using a standard operative protocol of anatomical reduction, fixation with a locking plate and supplementation by structural allografts in unstable fractures. The functional and radiological outcomes were reviewed.

At two years after operation the median Constant score was 86 points and the median Disabilities of the Arm, Shoulder and Hand score 17 points. Seven of the patients underwent further surgery, two for failure of fixation, three for dysfunction of the rotator cuff, and two for shoulder stiffness. The two cases of failure of fixation were attributable to violation of the operative protocol. In the 46 patients who retained their humeral head, all the fractures healed within the first year, with no sign of collapse or narrowing of the joint space. Longer follow-up will be required to confirm whether these initially satisfactory results are maintained.