In 2005, we demonstrated that the polished triple-tapered
C-stem at two years had migrated distally and rotated internally.
From that series, 33 patients have now been followed radiologically,
clinically and by radiostereometric analysis (RSA) for up to ten
years. The distal migration within the cement mantle had continued
and reached a mean of 2 mm (0.5 to 4.0) at ten years. Internal rotation,
also within the cement mantle, was a mean 3.8° (external 1.6° to
internal 6.6°) The cement mantle did not show any sign of migration
or loosening in relation to the femoral bone. There were no clinical
or radiological signs indicating that the migration or rotation
within the cement mantle had had any
There are a number of patients in whom hip preservation surgery is not indicated as they have developed signs of early osteoarthritis, and nor can they have a hip replacement as they are too early in the disease process. The use of PRP in OA of the hip has not been studied systematically and this study concisely collates all the available data in the use of PRP in Hip OA. This systematic review and meta-analysis aimed to assess intra-articular platelet-rich plasma as a therapeutic intervention for hip osteoarthritis, including the duration of efficacy, influence of dose and composition of PRP, and the incidence of
Constrained acetabular inserts provide a solution for both complex primary and revision hip arthroplasty, but there have been ongoing concerns for high risk of failure and their longevity. The Stryker® Trident acetabular insert is pre-assembled with its constrained ring. We believe this to be the largest series of constrained acetabular inserts with a minimum of 5 year follow-up. We retrospectively reviewed all Stryker® Trident ‘All-Poly’ constrained acetabular inserts cemented into bone in our unit between 2008 and 2016. We collated demographic details and reviewed all patients’ radiographs and clinical notes. Indications for surgery, latest Oxford Hip Scores (OHS) and clinical and radiographic complications were identified. 117 consecutive Stryker® Trident ‘All-Poly’ constrained inserts were cemented into bone in 115 patients during the study period with a mean age of 80 (47–97). Most common indications for surgery were recurrent dislocation (47), complex primary arthroplasty (23), revision arthroplasty (19) and failed hemiarthroplasty (12). 41 patients required revision of the acetabular component only. Follow-up was a minimum of 5 years (mean 8.6, range 5–13). There were three 30-day mortalities and six 1-year mortalities. The mean latest OHS was 37 (24–45). Four cups failed in three patients, one at the cement-bone interface, two at the cement-prosthesis interface and one at the bipolar interface. These were treated conservatively in three patient and with excision arthroplasty in one patient. There were four peri-prosthetic fractures, one Vancouver C distal femur fracture treated conservatively and three Vancouver B1 fractures, two treated conservatively and one treated with open reduction internal fixation. There was breakage of one constrained ring with no
Aims. A recent report from France suggested an association between the use of cobalt-chrome (CoCr) femoral heads in total hip arthroplasties (THAs) and an increased risk of dilated cardiomyopathy and heart failure. CoCr is a commonly used material in orthopaedic implants. If the reported association is causal, the consequences would be significant given the millions of joint arthroplasties and other orthopaedic procedures in which CoCr is used annually. We examined whether CoCr-containing THAs were associated with an increased risk of all-cause mortality, heart outcomes, cancer, and neurodegenerative disorders in a large national database. Methods. Data from the National Joint Registry was linked to NHS English hospital inpatient episodes for 374,359 primary THAs with up to 14.5 years' follow-up. We excluded any patients with bilateral THAs, knee arthroplasties, indications other than osteoarthritis, aged under 55 years, and diagnosis of one or more outcome of interest before THA. Implants were grouped as either containing CoCr or not containing CoCr. The association between implant construct and the risk of all-cause mortality and incident heart failure, cancer, and neurodegenerative disorders was examined. Results. There were 158,677 individuals (42.4%) with an implant containing CoCr. There were 47,963 deaths, 27,332 heart outcomes, 35,720 cancers, and 22,025 neurodegenerative disorders. There was no evidence of an association between patients with CoCr implants and higher rates of any of the outcomes. Conclusion. CoCr-containing THAs did not have an increased risk of all-cause mortality, or clinically meaningful heart outcomes, cancer, or neurodegenerative disorders into the second decade post-implantation. Our findings will help reassure clinicians and the increasing number of patients receiving primary THA worldwide that the use of CoCr-containing implants is not associated with significant
Studies have shown that 10–30% patients do not achieve optimal function outcomes after total hip replacement (THR). High quality randomised controlled trials (RCTs) evaluating the clinical and cost-effectiveness of techniques to improve functional outcomes after THR are lacking. We performed this study to evaluate the feasibility of a RCT comparing patient-reported functional outcomes after hybrid or fully cemented THR (ISRCTN11097021). Patients were recruited from two centres and randomised to receive either a fully cemented or hybrid THR. Data collection included Patient Reported Outcome Measures (PROMs), non-serious adverse events of special interest (AESI), serious
Background. Orthopedic surgeons have relied heavily on opiates after total hip replacement (THR) despite no clear evidence of benefit and a rapidly growing abuse epidemic. Multimodal analgesia may reduce or even obviate the need for opiates after elective surgery. Methods. In a cluster-randomized, crossover trial, 235 patients undergoing THR were assigned to receive multimodal analgesia with minimal opiates (Group A-10 tablets), multimodal analgesia with a full opiate supply (Group B-60 tablets), or a traditional opiate regimen without multimodal analgesia (Group C-60 tablets). The multimodal regimen comprised scheduled-dose acetaminophen, meloxicam, and gabapentin. Primary outcomes were daily pain and opiate utilization for the first 30-days. Secondary outcomes included assessments of satisfaction, sleep-quality, opiate-related symptoms, hip function, and adverse events. Results. Daily pain was significantly lower in both multimodal groups, Group A (Coeff −0.81, p=0.003) and Group B (Coeff −0.61, p=0.021). While daily utilization and duration of opiate use was lower for both Group A (Coeff −0.77, p<0.001) and Group B (Coeff −0.30, p=0.04) compared with Group C, opiate use was also lower for Group A than Group B (Coeff −0.46, p=0.002). There were significantly fewer opiate-related symptoms in Group A compared to Group C (p=0.005), but Group B and C didn't differ (p=0.13). Additionally, both multimodal regimens improved satisfaction and sleep, and there was no difference in hip function or adverse events. Conclusion. A multimodal analgesic regimen with minimal opiates improved pain control while significantly decreasing opiate utilization and opiate-related
Due to well-known complications of metal-on-metal hip resurfacing arthroplasty the indication for this procedure has significantly decreased over the past years. As a high number of patients is currently living with resurfacing implants, however, there is a clear need for information about the longterm results and especially about the rate of local as well as systemic
Infection of a total hip replacement (THR) requires component removal and thorough local debridement. Usually, long-term antibiotic treatment in conjunction with a two-stage revision is required. This may take several months. One-stage revision using antibiotic-loaded cement has not gained widespread use, although the clinical and economic advantages are obvious. Allograft bone may be impregnated with high levels of antibiotics, and in revision of infected THR, act as a carrier providing a sustained high local concentration. We performed 37 one-stage revision of infected THRs, without the use of cement. There were three hips which required further revision because of recurrent infection, the remaining 34 hips (92%) stayed free from infection and stable at a mean follow-up of 4.4 years (2 to 8). No
Four uncemented Symax hip stems were extracted at three weeks and nine, 13 and 32 months, respectively, for reasons other than loosening. The reasons for implant removal were infection in two cases, recurrent dislocation in one and acetabular fracture in one. They were analysed to assess the effect and behaviour of an electrochemically deposited, completely resorbable biomimetic BONIT-hydroxyapatite (HA) coating (proximal part) and a DOTIZE surface treatment (distal part) using qualitative histology, quantitative histomorphometry and scanning electron microscopy (SEM). Early and direct bone-implant bonding with signs of active remodelling of bone and the HA coating were demonstrated by histology and SEM. No loose BONIT-HA particles or delamination of the coating were observed, and there was no inflammation or fibrous interposition at the interface. Histomorphometry showed bone-implant contact varying between 26.5% at three weeks and 83.5% at 13 months at the HA-coated implant surface. The bone density in the area of investigation was between 24.6% at three weeks and 41.1% at 32 months. The DOTIZE surface treatment of the distal part of the stem completely prevented tissue and bone apposition in all cases, thereby optimising proximal stress transfer. The overall features of this implant, in terms of geometry and surface texture, suggest a mechanically stable design with a highly active biomimetic coating, resulting in rapid and extensive osseo-integration, exclusively in the metaphyseal part of the stem. Early remodelling of the HA coating does not seem to have a detrimental effect on short-term bone-implant coupling. There were no
We have investigated the effect of using tranexamic
acid (TXA) during peri-acetabular osteotomy (PAO) on peri-operative
blood loss and blood transfusion requirements. In addition we analysed
whether the use of TXA was associated with an increased risk of
venous thromboembolism (VTE) following this procedure. A consecutive series of 96 PAOs, performed by a single surgeon,
were reviewed. A total of 48 patients received TXA and 48 did not.
The TXA group received a continuous infusion of TXA at a rate of
10 mg/kg/h. The primary outcome measure was the requirement for
blood transfusion. Secondary outcomes included total blood loss,
the decrease in the level of haemoglobin in the blood, the length
of hospital stay, and the complications of this treatment. The mean rate of transfusion was significantly lower in the TXA
group (62.5% vs 12.5%, p <
0.001). The mean blood
loss was also significantly reduced in the TXA group (1.9 L (standard
deviation (. sd. ) 0.9) vs 1.5 L (. sd. 0.7),
p <
0.01). No post-operative episodes of VTE were identified
in either group. . The use of TXA reduced the blood loss and the rate of transfusion
after PAO significantly, without
Metal-on-metal bearings are being increasingly used in young patients. The potential
Perthes’ disease (PD) is a childhood hip disorder that can affect the quality of life in adulthood due to femoral head deformity and osteoarthritis. There is very little data on how PD patients function as adults, especially from the patients’ perspective. The purpose of this study was to collect treatment history, demographic details, the University of California, Los Angeles activity score (UCLA), the 36-Item Short Form survey (SF-36) score, and the Hip disability and Osteoarthritis Outcome score (HOOS) of adults who had PD using a web-based survey method and to compare their outcomes to the outcomes from an age- and sex-matched normative population. The English REDCap-based survey was made available on a PD study group website. The survey included childhood and adult PD history, UCLA, SF-36, and HOOS. Of the 1,182 participants who completed the survey, the 921 participants who did not have a total hip arthroplasty are the focus of this study. The mean age at survey was 38 years (SD 12) and the mean duration from age at PD onset to survey participation was 30.8 years (SD 12.6).Aims
Methods
Refobacin Bone Cement R and Palacos Overall, 75 patients were included in the study and 71 were available at two years postoperatively. Prior to surgery, they were randomized to one of the three combinations studied: Palacos cement with use of the Optivac mixing system, Refobacin with use of the Optivac system, and Refobacin with use of the Optipac system. Cemented MS30 stems and cemented Exceed acetabular components were used in all hips. Postoperative radiographs were used to assess the quality of the cement mantle according to Barrack et al, and the position and migration of the femoral stem. Harris Hip Score, Oxford Hip Score, Forgotten Joint Score, and University of California, Los Angeles Activity Scale were collected.Aims
Methods
Introduction. Total Hip Replacement (THR) is an effective treatment for end stage degenerative disease of the hip and offers patients the prospect of long term pain relief, improved joint function and quality of life. Enhanced Recovery Programmes (ERP) aim to standardise routine perioperative care, reduce hospital length of stay (LOS) and promote rapid recovery after elective surgery. The aim of this study was to determine whether the implementation of an ERP could successfully reduce the length of hospital stay associated with primary THR and whether this could be achieved without compromising the expected functional outcome or risking an increased dislocation rate. Patients/Materials & Methods. Prospectively collected data on 1161 patients (611 managed with traditional rehabilitation and 550 with ERP) undergoing primary unilateral THR between 2005 and 2013 was retrospectively reviewed. Univariable statistical analysis was undertaken to identify factors that appeared to predict length of stay and a multiple linear regression model was then constructed to determine the significance and strength of effect of the individual predictors. Results. Median LOS was 5 days for those managed in the traditional method and 3 days for those managed with ERP (p<0.001). Multivariate regression models demonstrate that this effect on LOS is independent of and stronger than other factors affecting LOS and we did not observe increased rates of dislocation (1.03% versus 0.73%, p=0.75) or mortality (1.5% versus 0.6%, p=0.14) at one year postoperative in patients managed with ERP. Both groups demonstrated significant improvement in mean Harris Hip Score (+42.8 versus +41.5) at twelve to eighteen months postoperative and there was no significant difference in the magnitude of improvement between groups (p=0.09). Discussion. This is the first study to demonstrate the independent effect of ERP on LOS through multiple regression analysis and to directly compare functional outcomes of patients managed with ERP with the accepted gold standard (traditional rehabilitation) and these findings will be of use to surgeons counselling patients peiroperatively and healthcare planners. Conclusion. Implementation of ERP can reduce the hospital LOS for primary THR without
The aim of this study was to evaluate the incidence of liner malseating in two commonly used dual-mobility (DM) designs. Secondary aims included determining the risk of dislocation, survival, and clinical outcomes. We retrospectively identified 256 primary total hip arthroplasties (THAs) that included a DM component (144 Stryker MDM and 112 Zimmer-Biomet G7) in 233 patients, performed between January 2012 and December 2019. Postoperative radiographs were reviewed independently for malseating of the liner by five reviewers. The mean age of the patients at the time of THA was 66 years (18 to 93), 166 (65%) were female, and the mean BMI was 30 kg/m2 (17 to 57). The mean follow-up was 3.5 years (2.0 to 9.2).Aims
Methods
Hip arthroplasty aims to accurately recreate joint biomechanics. Considerable attention has been paid to vertical and horizontal offset, but femoral head centre in the anteroposterior (AP) plane has received little attention. This study investigates the accuracy of restoration of joint centre of rotation in the AP plane. Postoperative CT scans of 40 patients who underwent unilateral uncemented total hip arthroplasty were analyzed. Anteroposterior offset (APO) and femoral anteversion were measured on both the operated and non-operated sides. Sagittal tilt of the femoral stem was also measured. APO measured on axial slices was defined as the perpendicular distance between a line drawn from the anterior most point of the proximal femur (anterior reference line) to the centre of the femoral head. The anterior reference line was made parallel to the posterior condylar axis of the knee to correct for rotation.Aims
Methods
To evaluate the effect of ultrasound-targeted simvastatin-loaded microbubble destruction (UTMD In vitro, OA chondrocytes were treated with ultrasound (US), US-targeted microbubble destruction (UTMD), simvastatin (SV), and UTMDAims
Methods
Dual mobility implants in total hip arthroplasty are designed to increase the functional head size, thus decreasing the potential for dislocation. Modular dual mobility (MDM) implants incorporate a metal liner (e.g. cobalt-chromium alloy) in a metal shell (e.g. titanium alloy), raising concern for mechanically assisted crevice corrosion at the modular liner-shell connection. We sought to examine fretting and corrosion on MDM liners, to analyze the corrosion products, and to examine histologically the periprosthetic tissues. A total of 60 retrieved liners were subjectively scored for fretting and corrosion. The corrosion products from the three most severely corroded implants were removed from the implant surface, imaged using scanning electron microscopy, and analyzed using Fourier-transform infrared spectroscopy.Aims
Methods
Aseptic loosening is a leading cause of uncemented arthroplasty failure, often accompanied by fibrotic tissue at the bone-implant interface. A biological target, neutrophil extracellular traps (NETs), was investigated as a crucial connection between the innate immune system’s response to injury, fibrotic tissue development, and proper bone healing. Prevalence of NETs in peri-implant fibrotic tissue from aseptic loosening patients was assessed. A murine model of osseointegration failure was used to test the hypothesis that inhibition (through Patient peri-implant fibrotic tissue was analyzed for NETs biomarkers. To enhance osseointegration in loose implant conditions, an innate immune system pathway (NETs) was either inhibited (Aims
Methods
Vitamin E-infused highly crosslinked polyethylene (VEPE) has been introduced into total hip arthroplasty (THA) with the aim of further improving the wear characteristics of moderately and highly crosslinked polyethylenes (ModXLPE and HXLPE). There are few studies analyzing the outcomes of vitamin E-infused components in cemented arthroplasty, though early acetabular component migration has been reported. The aim of this study was to measure five-year polyethylene wear and acetabular component stability of a cemented VEPE acetabular component compared with a ModXLPE cemented acetabular component. In a prospective randomized controlled trial (RCT), we assessed polyethylene wear and acetabular component stability (primary outcome) with radiostereometric analysis (RSA) in 68 patients with reverse hybrid THA at five years follow-up. Patients were randomized to either a VEPE or a ModXLPE cemented acetabular component.Aims
Methods