Advertisement for orthosearch.org.uk
Results 1 - 20 of 26
Results per page:
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 108 - 108
1 Feb 2020
Aggarwal A Sharif D Prakash M Saini U
Full Access

Introduction. Patients undergoing total knee arthroplasty (TKA) with end-stage osteoarthritis of knee have secondary foot and ankle pathology. Some compensatory changes occur at ankle and subtalar joint secondary to malalignment and deformity at the knee joint. Purpose was to evaluate the changes in hindfoot malalignment and foot deformities in patients with advanced osteoarthritis of knee requiring TKA and effect of correction of knee deformities post TKA on foot/Ankle alignment. Methods. 61 consecutive patients with Kellgren-Lawrence grade IV osteoarthritis knee undergoing TKA were enrolled in a prospective blinded study. Demographic data, deformities at knee and ankle, hindfoot malalignment and functional outcome scores such as VAS, KSS, WOMAC scores, Foot and Ankle Disability Index (FADI) and Foot posture index (FPI) were recorded preoperatively and postoperatively at 6, 12 weeks and final follow up (range: 6–21 months; mean: 14.2months). Results. Statistically significant improvement was observed in KSS score, WOMAC score, FADI and FPI after TKA. There was improvement in ankle valgus after correction of knee varus deformity. Hind foot changes mainly occured at subtalar joint. Hallux valgus (10 patients), and Pesplanus (5 patients) were associated with advanced osteoarthritis of knee. Gait profile score and Gait deviation index improved significantly after TKA. There was increased stance phase and decreased stride length in knee osteoarthritis patients which improved after TKA. Conclusion. Hind foot malalignment with foot deformities (hind foot valgus) occur secondary to knee malalignment and deformities (varus deformity) in advanced osteoarthritis of knee which subsequently improve following TKA


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 55 - 55
1 May 2012
H. R R. R S. D T. A R H
Full Access

Purpose. To examine measurement properties of four disability outcomes in patients with advanced osteoarthritis of the glenohumeral joint. Methods. This was a prospective longitudinal study of patients with advanced osteoarthritis of the glenohumeral joint who underwent a Total Shoulder Arthroplasty (TSA) and were followed for 6 months. Four measures [Western Ontario Osteoarthritis Shoulder (WOOS) Index, the American Shoulder and Elbow Surgeons (ASES) assessment, Constant-Murley score (CMS), and Quick Disabilities of the Arm, Shoulder, and Hand (QuickDASH)] were completed 2-3 weeks before surgery and at 6 months after surgery. Results. Seventy-seven patients (average age: 66, range 35 to 86, 60% women, 40% men) participated in the study. The Cronbach's Coefficient Alpha of subjective measures was high at 0.91, 0.86, and 0.83 for WOOS, ASES, and QuickDASH respectively. All measures were able to discriminate between men and women's levels of disability at p< 0.05. Correlations between pre-operative scores were moderate (0.59 to -0.79) and slightly increased post-operatively (0.61 to -0.87). All measures were sensitive in detecting change in the disability status over a period of 6 months. Conclusion. All four disability measures were reliable and valid for use in patients with advanced osteoarthritis of the glenohumeral joint. Outcome measurement in busy clinics can be facilitated by choosing valid and reliable measures that have the advantage of simplicity for use by patients and clinicians. The consensus-based standards for selection of outcome measures have been developed for hip and knee arthritis and need to take place for the shoulder joint. Developing consensus by an international group of experts will improve consistency in using outcome measures in patients with shoulder problems


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_13 | Pages 13 - 13
1 Nov 2019
Saini UC Kumar AS S Prakash M Aggarwal AK
Full Access

Advanced osteoarthritis of knee is associated with low-backache in a significant number of patients and adversely affects the quality of life. There is a paucity of literature describing outcomes of backache after total-knee-arthroplasty (TKA). We evaluated backache in patients of advanced knee-osteoarthritis and their functional and radiological outcomes after TKA after approval from Institutional ethics committee. Fifty-nine patients (40 females and 19 males) were included. Mean body-mass index was 28.7. Mean visual analogue score (VAS) for knee-pain was 7.98 preoperatively and 1.6 in follow-up. For chronic backache, the mean VAS score improved from 6.08 to 2.4, Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) improved from 67.5 to 37.8, Knee society score (KSS) from 49.8 to 76.6, Oswestry Disability Index (ODI) Score from 55.44 to 34.65 and SF-36 Quality-of-life score from 44.95 to 74.63. There was a significant correlation between in knee and low-back functional scores. Magnetic resonance imaging-based scoring of degenerative changes (Pfirrmann grading) showed improvement only in 13.5% patients; 56% showed no change and 30.5% showed deterioration of scores. Chronic low backache is a significant co-morbidity in advanced knee-osteoarthritis. TKA has the potential to relieve backache along with knee-pain and improves quality of life


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 27 - 27
10 May 2024
Chan V Yeung S Chan P Fu H Cheung M Cheung A Luk M Tsang C Chiu K
Full Access

Introduction and Aim

Quadriceps strength is crucial for physical function in patients with knee osteoarthritis (KOA). This study aimed to investigate the effect of combining blood flow restriction (BFR) with low-intensity training (LIT) on quadricep strength in patients with advanced KOA.

Methods

Patients with advanced KOA were block randomized by gender into the control or BFR group. The control group received LIT with leg press (LP) and knee extension (KE) at 30% of 1-repetition maximum (1-RM), while the BFR group underwent the same training with 70% limb occlusion.

Physical function and patient-reported outcomes were assessed up to 16 weeks.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_13 | Pages 5 - 5
1 Nov 2019
Prasad KSRK Schemitsch E Lewis P
Full Access

Tibial cut is a crucial step in ensuring adequate and appropriate proximal tibial resection for mechanical orientation and axis in total knee replacement. We evolved the concept and technique of Condylar Differential for planned tibial cuts in conventional total knee replacement, which accounts for individual variations and reflects individual mechanical orientation and alignment. We used Condylar Differential in 37 consecutive total knee replacements including valgus knees and severe advanced osteoarthritis. First a vertical line is drawn on digital weight bearing anteroposterior radiograph for mechanical axis of tibia. Then a horizontal line is drawn across and perpendicular to the mechanical axis. The distances between the horizontal line and the lowest reproducible points of articular surfaces of medial and lateral tibial condyles respectively are measured. The difference between two measurements obviously represents Condylar Differential. Condylar Differential, adjusted to the nearest millimetre, is maintained in executing tibial cuts, successively if necessary. Condylar Differential measurement showed a very wide variation, ranging from 8–6 (2 mm) to 10-0 (10 mm). We found that prior measurement of Condylar Differential is a simple, consistent and effective estimate and individualises the tibial cut for optimal templating of tibia. We encountered no problems, adopting this technique, in our series. Condylar Differential contributes to optimal individualised tibial cut in conventional total knee replacement and is a useful alternative to computer navigated option with comparable accuracy in this respect. While we used the technique in digitised radiographs, this technique can also be applied to plain films, allowing for magnification


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_13 | Pages 10 - 10
1 Nov 2019
Kheiran A Ngo DN Bindra R Wildin CJ Ullah A Bhowal B Dias JJ
Full Access

The primary aim of this study was to identify the rate of osteoarthritis in scaphoid fracture non-union. We also aimed to investigate whether the incidence of osteoarthritis correlates with the duration of non-union(interval), and to identify the variables that influence the outcome. We retrospectively reviewed 273 scaphoid fracture non-union presented between 2007 and 2016. Data included patient demographics, interval, fracture morphology, grade of osteoarthritis (Kellgren-Lawrence) and scaphoid non-union advanced collapse (SNAC), and overall health-related quality of life. Patients were divided into two groups (SNAC and Non-SNAC). Group differences were analysed using Mann-Whitney U test and association with Pearson's correlations. A two-sided p-value of <0.05 was considered significant. The scaphoid fracture non-union were confirmed on CT scans (n=243) and plain radiographs (n=35). The subjects were 32 females and 260 males with the mean age of 33.8 years (SD, 13.2). The average interval was 3.1 years (range, 0–45 years). Osteoarthritis occurred in 58% (n=161) of non-unions, and 42% (n=117) had no osteoarthritis. In overall, 38.5% (n=107) had SNAC-1, 9% (n=25) with SNAC-2, and 10.4% (n=29) presented with SNAC-3. The mean interval in the non-SNAC group was 1.2 years, and in SNAC 1,2, and 3 were 2.6, 6.8, and 11.1 years, respectively. The average summary index in SNAC and non- SNAC groups was 0.803 and 0.819, respectively. Our results also showed a significant correlation between advanced osteoarthritis and proximal fracture non-unions(P<0.05). We concluded that there is no clear correlation between the interval and the progression of osteoarthritis. SNAC was more likely to occur in fractures aged 2 years or older


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 145 - 145
1 Apr 2019
Prasad KSRK Schemitsch E Lewis P
Full Access

Background. Mechanics and kinematics of the knee following total knee replacement are related to the mechanics and kinematics of the normal knee. Restoration of neutral alignment is an important factor affecting the long-term results of total knee replacement. Tibial cut is a vital and crucial step in ensuring adequate and appropriate proximal tibial resection, which is essential for mechanical orientation and axis in total knee replacement. Tibial cut must be individually reliable, reproducible, consistent and an accurate predictor of individual anatomical measurements. Conventional tibial cuts of tibia with fixed measurements cannot account for individual variations. While computer navigated total knee replacement serves as a medium to achieve this objective, the technology is not universally applicable for differing reasons. Therefore we evolved the concept and technique of Condylar Differential for planned tibial cuts in conventional total knee replacement, which accounts for individual variations and reflects the individual mechanical orientation and alignment. Methods. We used the Condylar Differential in 37 consecutive total knee replacements. We also applied the technique in valgus knees and severe advanced osteoarthritis. First a vertical line is drawn on the digital weight bearing anteroposterior radiograph for mechanical axis of tibia. Then a horizontal line is drawn across and perpendicular to the mechanical axis of tibia. The distances between the horizontal line and the lowest reproducible points of the articular surfaces of the medial and lateral tibial condyles respectively are measured. The difference between the two measurements obviously represents the Condylar Differential. Condylar Differential, adjusted to the nearest millimeter, is maintained in executing the tibial cuts, if necessary successive cuts. Results. Condylar Differential measurement showed a very wide variation, ranging from 8–6 (2 mm) to 10-0 (10 mm). We found that prior measurement of Condylar Differential is a simple, consistent and effective estimate and individualizes the tibial cut for optimal templating of tibia in total knee replacement. We encountered no problems, adopting this technique, in our consecutive series of total knee replacements. Conclusions. Condylar Differential contributes to optimal individualized tibial cut in conventional total knee replacement and is a useful alternative to computer navigated option with comparable accuracy in this respect. While we used the technique of Condylar Differential in digitized radiographs, this technique can also be applied to plain films, allowing for the magnification


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 31 - 31
1 Apr 2019
Torres A Goldberg T Bush JW
Full Access

Introduction. Total knee arthroplasty is a highly effective procedure to improve the quality of life in patients with advanced osteoarthritis. The number of these procedures are expected to grow 174% by 2030. This growth rate is expected to economically strain the health care system. A potential solution to alleviate this problem is the utilization of single use instruments (SUI). Potential advantages of SUI include: improved operating room efficiencies, decreased costs associated with traditional instrument management (sterile processing, shipping), and decreased infection risk. The present study examines the clinical results of SUI compared to standard instrumentation. Furthermore, economic modeling is performed to examine the cost savings that is potentially realized with their use. Materials and Methods. 51 patients receiving a TKA with use of SUI were prospectively compared to 49 patients utilizing standard instrumentation. Knee Society Scores and Radiographic alignment will be evaluated. Adverse events will be recorded. Economic modeling of SUI will be performed in 4 different areas: 1. Decreased infection burden; 2. Operating room logistics; 3. Sterile processing savings; and 4. Instrument logistical savings. Results. The average Pre-operative KSS (Objective/Functional) scores were 48.7/41.6 for the SIU patients compared to 50.2/38.7 for the standard instrumentation patients. Post-operative improvements measured 84.0/72.8 and 83.9/76.4 for the 2 groups respectively. The Pre-operative Hip-Knee-Ankle Angle was 176.2 and 177.0 for the 2 groups. The SUI HKA improved to 179.3 while the standard improved to 178.9. There were no statistical differences between the 2 groups. Furthermore, there were no cases of subsidence, migration, loosening, or infection in either group. There were no SUI procedure abandonments. Economic analysis revealed a decreased risk of Infection burden of $28.08/case. Operating room efficiencies include reduced set-up/take-down time and case efficiency savings/case. This averages $348.14/case. Instrument sterilization savings occur by bypassing the central sterile-processing department completely and models to $700/case. Finally, instrument logistics savings include time and money spent organizing/turning over/shipping instrument sets for cases. This estimate is $112.88/case for a total economic value of $1, 189.10/case. Discussion. In summary, the present study confirms that SUI provides similar clinical and radiographic results to standard instrumentation for TKA. Furthermore, SUI offers significant cost savings/case via potential benefits of reduced risk of infection, increased operating room productivity, and significant tray sterilization and loaner instrumentation cost savings


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 128 - 128
1 Apr 2019
Kebbach M Geier A Darowski M Krueger S Schilling C Grupp TM Bader R
Full Access

Introduction. Total knee replacement (TKR) is an established and effective surgical procedure in case of advanced osteoarthritis. However, the rate of satisfied patients amounts only to about 75 %. One common cause for unsatisfied patients is the anterior knee pain, which is partially caused by an increase in patellofemoral contact force and abnormal patellar kinematics. Since the malpositioning of the tibial and the femoral component affects the interplay in the patellofemoral joint and therefore contributes to anterior knee pain, we conducted a computational study on a cruciate-retaining (CR) TKR and analysed the effect of isolated femoral and tibial component malalignments on patellofemoral dynamics during a squat motion. Methods. To analyse different implant configurations, a musculoskeletal multibody model was implemented in the software Simpack V9.7 (Simpack AG, Gilching, Germany) from the SimTK data set (Fregly et al.). The musculoskeletal model comprised relevant ligaments with nonlinear force-strain relation according to Wismans and Hill-type muscles spanning the lower extremity. The experimental data were obtained from one male subject, who received an instrumented CR TKR. Muscle forces were calculated using a variant of the computed muscle control algorithm. To enable roll-glide kinematics, both tibio- and patellofemoral joint compartments were modelled with six degrees of freedom by implementing a polygon-contact-model representing the detailed implant surfaces. Tibiofemoral contact forces were predicted and validated using data from experimental squat trials (SimTK). The validated simulation model has been used as reference configuration corresponding to the optimal surgical technique. In the following, implant configurations, i.e. numerous combinations of relative femoral and tibial component alignment were analysed: malposition of the femoral/tibial component in mediolateral (±3 mm) and anterior-posterior (±3 mm) direction. Results. Mediolateral translation/malposition of the tibial component did not show high influence on the maximal patellofemoral contact force. Regarding the mediolateral translation of the femoral component, similar tendencies were observed. However, lateralisation of the femoral component (3 mm) clearly increased the lateral patella shift and medialisation of the tibial component (3 mm) led to a slightly increased lateral patella shift. Compared to the reference model, pronounced posterior translation of the tibial and femoral component resulted in a lower patellofemoral contact force, further increasing with higher anterior translation of the components. The translation of the tibial component showed smaller influence on the patellofemoral contact force than the translation of the femoral component. Discussion. In our present study, the mediolateral malposition of the femoral and tibial component showed no major impact on patellofemoral contact force and contribution to anterior knee pain in patients with CR TKR. However, the influence of implant component positioning in anterior-posterior direction on patellofemoral contact force is evident, especially for the femoral component. Our generated musculoskeletal model can contribute to computer-assisted preclinical testing of TKR and may support clinical decision-making in preoperative planning


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 83 - 83
1 Jun 2018
Lachiewicz P
Full Access

It is unusual to require the use of a total knee implant with more constraint than a posterior-stabilised post in primary knee arthroplasty. The most common indication is a knee with a severe deformity, usually fixed valgus with an incompetent medial collateral ligament, and an inability to correctly balance the knee in both flexion and extension. The pre-operative deformity is usually greater than 15–20 degrees fixed valgus and may be associated with a severe flexion contracture. This is usually seen in an elderly female patient with advanced osteoarthritis. Those pre-operative diagnoses more likely to require a constrained design include advanced rheumatoid arthritis, true neuropathic joint, and the “Charcot-like” joint due to bone loss or crystalline arthritis. Rarely, patients with periarticular knee Paget's disease of bone may require more constraint following correction of a severe deformity through the knee joint. Beware those patients with a staple or screw at the medial epicondyle or those with severe heterotopic ossification at the medial joint line, as this may signify a serious prior injury to the medial collateral ligament. Finally, there is a possibility of inadvertent division of the medial collateral ligament intra-operatively. Although this situation may be treated with suture repair and bracing, my choice is to switch to more constraint and early unbraced motion. There are over 20 designs of varus-valgus constrained components, with a variety of tibial post designs with specific rotary and angular biomechanics, and many have the option of adding modular stems. Our experience with constrained, non-linked designs has been favorable with both the use of nonmodular and modular stem extensions. Longer-term survival analysis has shown a 96% survival at 10 years with these constrained components. However, the older designs frequently required a lateral retinacular release for proper patella tracking, and there were patella complications (fracture and osteonecrosis) in 16%. With a more modern design, over the past 12 years, the need for a lateral retinacular release and patella complications have been notably decreased. Varus-valgus constrained components have a small but important role in primary total knee arthroplasty for patients with severe deformity or an incompetent medial collateral ligament


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 65 - 65
1 Apr 2018
Chang S
Full Access

Total knee arthroplasty has been the main treatment method among advanced osteoarthritis (OA) patients. The main post-operative evaluation considers the level of pain, stability and range of motion (ROM). The knee flexion level is one of the most important categories in the total knee arthroplasty patient's satisfaction in Asian countries due to consistent habits of floor-sitting, squating, kneeling and cross legged sitting. In this study, we discovered that the posterior capsular release enabled the further flexion angles by 14 degrees compared to the average ROM without posterior release group. Our objective was to increase the ROM using the conventional total knee arthroplasty by the posterior capsular release. Posterior capsular release is being used in order to manage the flexion contraction. Although the high flexion method extends the contact area during flexion by extending the posterior condyle by 2mm, the main problem has been the early femoral loosening. We searched for the method to get the deep knee flexion with the conventional knee prosthesis. 122 OA patients with less than preoperative 130 flexion that underwent conventional TKAs using Nexgen from January, 2014 to September, 2016 were reviewed. Posterior femoral osteophytes were removed as much as possible, but 74 cases were performed posterior capsular release, while 48 cases were not performed. After checking postoperative ROM after 6 months of operation, we compared 74 knees with a posterior capsular release and 48 knees without posterior capsular release. As a result, the average ROM in the posterior capsular release group was 132 degrees, but the average ROM without posterior release group is 118 degrees. No postoperative hyperextension was found when the adequate size of polyethylene (PE) thickness was utilized. Hence, the conventional TKA with a posterior capsular release showed satisfactory clinical outcomes in the deep knee flexion of Asians


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 85 - 85
1 Apr 2019
Haidar F Tarabichi S Osman A Elkabbani M Mohamed T
Full Access

Introduction. Most of the algorithm available today to balance varus knee is based on a surgeon's hands-on experience without full understanding of pathological anatomy of varus knee. The high-resolution MRI allows us to recognize the anatomical details of the posteromedial corner and the changes of the soft tissue associated with the osteoarthritis and varus deformity. We have in this study, reviewed 60 cases of severe varus knee scheduled for TKR and compared it to normal MRI and those MRI were evaluated and read by a musculoskeletal radiologist. We have documented clearly the changes that happens in soft tissue, leading to tight medial compartment. We will also show multiple short intra-operative video confirming that MRI findings. Material & method. We have retrospectively reviewed the MRI on 60 patients with advanced osteoarthritis varus knee. We also reviewed 20 MRI for a normal knee matched for age. We evaluated the posteromedial complex and MCL in sagittal PD-weighted VISTA to check the alignment of the MCL and posteromedial complex and the associate MCL bowing and deformity that could happen in osteoarthritis knee. We have measured the thickness of the posteromedial complex and the posterior medial bowing of the superficial MCL and the involvement of the posterior oblique ligament in those patients. To measure the posterior bowing of the MCL, a line was drawn through the posterior aspect of both menisci and we measured the distance between the posterior edge of MCL to that line in actual image. To measure the thickness of the posteromedial complex, we measured it at two areas in the posterior medial corner posteriorly at the level of the medial meniscus. Measuring the medial bowing of the MCL was done by a line drawn through the medial edge of the femoral condyle and the tibial condyle at the level of the medial meniscus to the inner aspect of the MCL. The normal distance between the posterior aspects of the MCL to the posterior meniscus line was approximately measured 2 cm. in average. Results. We were able to recognize and measure the medial deviation of MCL in all arthritic knees due to the deformity and the effect of the medial margin osteophyte and medial extrusion of the meniscus. Thickening of posteromedial complex was recognized in the majority of the cases with prominent thickening seen in 50/60 knees with average thickness measuring approximately 1.2 cm due to the synovial thickening, adhesions, granulation tissue, degenerated medial meniscus, and involvement of the posterior oblique ligament and the capsular branch of the semimembranosus tendon, as well as the oblique popliteal ligament. The involvement of posterior oblique ligament were seen in majority of the cases. In 55 cases we have showed a heterogeneous appearance of the ligament and loss of normal signal within the postero medial complex and we have documented that the oblique ligament will cause the posterior bowing of the MCL. The medial bowing of the MCL is also correlated to the severity of the varus deformity with an average distance to the normal medial line of the medial meniscus measuring approximately 1.1 cm. Discussion. Our study shows that the changes affecting the superficial MCL is likely to be secondary to the obvious changes involving the posteromedial complex and to the marginal osteophyte as well as the extrusion of the medial meniscus. Also, we have confirmed that there are deforming structures such as the oblique ligament with adhesion and thickening with all the posterior medial complex. Those changes clearly caused the posterior bowing to the superficial MCL without an actual shortening of the ligament. The scarring tissue in the posteromedial corner and the adhesion is acting as a soft phyte tensioning and deforming the ligament and the posterior capsule. The oblique ligament act as a deforming forces forcing the superficial MCL to bow posteriorly. The lengths of the superficial MCL stayed the same. Conclusion. The conventional wisdom of releasing the distal attachment of the superficial medial MCL to balance knee has to be a challenge based on our MRI finding. Releasing the superficial MCL can sometimes lead to a major instability of the knee requiring a more constrained implant. Our MRI assessment clearly showed that the Superficial MCL is deformed because of posterior bowing and medial bowing and considerable thickening of the posteromedial corner, as well as the accompanying osteophyte. We believe that clearing the superficial MCL and excising those thickened scar tissue in the posterior medial corner will enable us to balance the knee without creating instability Conclusion: The conventional wisdom of releasing the distal attachment of the superficial medial MCL to balance knee has to be a challenge based on our MRI finding. Releasing the superficial MCL can sometimes lead to a major instability of the knee requiring a more constrained implant. Our MRI assessment clearly showed that the Superficial MCL is deformed because of posterior bowing and medial bowing and considerable thickening of the posteromedial corner, as well as the accompanying osteophyte. We believe that clearing the superficial MCL and excising those thickened scar tissue in the posterior medial corner will enable us to balance the knee without creating instability


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 114 - 114
1 May 2016
Laky B Koelblinger R Brandl G Anderl W Schwameis E
Full Access

Arthrodesis of the first metatarsophalangeal joint (MTPJ) has been reported as gold standard for the treatment of advanced hallux rigidus and is a well-documented procedure. However, many patients demand a mobile MTPJ and therefore joint sparing procedures like MTPJ-arthroplasty have gained popularity. The aim of the present study was to present first mid-term results after hemiarthroplasty to treat advanced osteoarthritis of the first MTPJ. Between April 2006 and October 2013, a total of 81 hemiprostheses (AnaToemic®, Arthrex) in 71 consecutive patients (44 females, 27 male, 10 bilateral; mean age, 58 [range, 45–82]) were implanted at the St. Vincent Hospital Vienna (Austria). The indication for surgery was persistent MTPJ pain after failed conservative treatment combined with radiologic evidence of osteoarthritis (advanced hallux rigidus grade II-IV). Patients were clinically examined using the American Orthopaedic Foot and Ankle Society (AOFAS) score before surgery and at the final follow-up visit. Patient's satisfaction with the treatment was recorded. Radiological results were evaluated using standard x-rays and revision surgeries were documented. The mean preoperative AOFAS Scores significantly increased from 51 to 88 points after an average follow-up duration of 5 years (p<0.001). Most patients (76%) were either very satisfied or satisfied with the procedure. Radiological assessment showed some kind of radiolucencies on the base plate, whereas the stem of the prosthesis was well integrated in most of the cases; however clinical outcome was not affected by minor radiolucent lines on the base plate. In the majority of patients the implant was in situ at last follow-up. If revision surgery, due postoperative pain or implant loosening, was required; it occurred within 12 to 36 months. According to our promising mid-term results with a MTPJ-hemiprostheses, we conclude that MTPJ-arthroplasty is an effective alternative treatment modality for anatomical reconstruction of the first MTPJ with the benefit to reduce pain and maintain mobility


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 168 - 168
1 Jun 2012
Nasser E Tarabichi S
Full Access

We hypothesize that tethering adhesions of the quadriceps muscle are the major pathological structures responsible for a limited range of motion in the stiff arthritic knee. Forty-two modified quadriceps muscle releases were performed on 24 patients with advanced osteoarthritis scheduled for total knee arthroplasty. The ranges of motion were documented intraoperatively both before and immediately after the release. Passive flexion improved significantly in all patients (mean, 32.4 degrees of improvement, P < .001) following a modified quadriceps release, despite any presence of osteophytes or severe deformities. These results strongly implicate adhesions of the quadriceps muscle to the underlying femur, which prevent the distal excursion of the quadriceps tendon, as the restrictive pathology preventing deep flexion in patients with osteoarthritis


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 75 - 75
1 May 2016
Nakano S Yoshioka S Toki S Kashima M Nakamura M Chikawa T Kanematsu Y Sairyo K
Full Access

Purpose. Proximal femoral osteotomy is an attractive joint preservation procedure for osteonecrosis of the femoral head. The purpose of this study was to investigate the cause of failure of proximal femoral osteotomy in patients with osteonecrosis of the femoral head. Patients and Methods. Between 2008 and 2014, proximal femoral osteotomy was performed by one surgeon in 13 symptomatic hips. Ten trans-trochanteric rotational osteotomies (anterior: 7, posterior: 3) and 3 intertrochanteric curved varus osteotomy were performed. Of the patients, 9 were male and 1 was female, with a mean age at surgery of 36.9 years (range, 25–55 years). The mean postoperative follow-up period was 38 months (range, 12–72 months). Three patients (4 hips) had steroid-induced osteonecrosis, and 7 (9 hips) had alcohol-associated osteonecrosis. At 6 postoperative weeks, partial weight bearing was permitted with the assistance of 2 crutches. At more than 6 postoperative months, full weight bearing was permitted. Patients who had the potential to achieve acetabular coverage of more than one-third of the intact articular surface on preoperative hip radiography, computed tomography, and magnetic resonance imaging were considered suitable for this operation. A clinical evaluation using the Japanese Orthopaedic Association (JOA) scoring system and a radiologic evaluation were performed. Clinical failure was defined as conversion to total hip arthroplasty (THA) or progression to head collapse and osteoarthritis. The 13 hips were divided into two groups, namely the failure and success groups. Results. The mean preoperative JOA score was 59 points. The score in the success group (7 hips) improved to 89 points at the time of final follow-up. In the failure group (6 hips), 5 hips were converted to THA because of progression to secondary collapse or osteoarthritis in a mean postoperative period of 35 months (range, 24–51 months). After converting to THA, good clinical and radiographic results were achieved, except in 1 patient who had incomprehensible severe pain around the affected hip. Advanced osteoarthritis was observed in 1 hip awaiting THA. Various factors cause failure of proximal femoral osteotomy, such as difficulty in controlling the underlying disease with less than 10 mg of steroid (Fig. 1), overuse of the affected hip within 6 postoperative months without the physician's consent, vascular occlusion after total necrosis of the femoral head as a result of damage to the nutritional vessel during or after the operation, and incorrect judgement of the indication of the operation and the extent of the intact load-bearing area. Conclusion. We think that full weight bearing should be permitted postoperatively only after more than 6 months, and heavy work and sport, only after more than 1 year. Efforts should be made to improve surgeons' skill in proximal femoral osteotomy and accurate judgement of imaging data. For steroid-induced osteonecrosis of the femoral head, proximal femoral osteotomy is an acceptable procedure for relieving pain if the underlying disease can be controlled with not more than 5 mg of steroid


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 220 - 220
1 Dec 2013
Aggarwal A Chakraborty S Bahl A
Full Access

Patients with symptomatic osteoarthritis of the knee are typically obese and relatively less active and may be associated with cardiovascular deconditioning and increased risk of heart disease. Purpose of this study was to evaluate the impact of the total knee arthroplasty upon cardiovascular status of the patient, as indicated by assessment of the endothelial function and correlation of the same with the functional outcome. Endothelial function has been found to correlate with the cardiovascular health of an individual closely and therefore was chosen as a noninvasive means to study the same. This study was conducted prospectively in 34 patients of advanced Osteoarthritis of knee joint (11 males, 23 females) who underwent unilateral (25) or bilateral (9) total knee arthroplasty at a mean age of 59.2 + 9.7 years (range 40–77 years). All the patients underwent preoperative assessment of endothelial function by the method of flow mediated dilatation (FMD). We report the results at 2 to 3.5 years (mean, 3.0) follow-up. The reassessment of the endothelial function and functional outcome in terms of Knee society score were performed at follow up. We noted excellent improvement in Knee society score (mean 102.3 + 22.9 at 6 months, 152.5 + 19.8 at 18 months and 174.4 + 17.3 at 42 months compared to 65.4 + 30.3 preoperatively). There was good improvement in endothelial function at 6 months (29.98 + 19.28%) and excellent improvement (69.87 + 35.57%) at 18 months and (85.65 + 26.14%) at 42 months respectively. Significant improvement in endothelial function can result following total knee arthroplasty


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLII | Pages 7 - 7
1 Sep 2012
Berstock JR Spencer RF
Full Access

Pre-existing hip pathology such as femoroacetabular impingement is believed by some, to have a direct causal relationship with osteoarthritis of the hip. The strength of this relationship remains unknown. We investigate the prevalence of abnormal bone morphology in the symptomatic hip on the pre-operative anteroposterior pelvic radiograph of consecutive patients undergoing hip resurfacing. Rotated radiographs were excluded. One hundred patients, of mean age 53.5 years were included (range 33.4–71.4 years, 32% female). We examined the films for evidence of a cam-type impingement lesion (alpha angle >50.5°, a pistol grip, Pitt's pits, a medial hook, an os acetabuli and rim ossification), signs of acetabular retroversion or a pincer-type impingement lesion (crossover sign, posterior wall sign, ischial sign, coxa profunda, protrusio, coxa vara, Tonnis angle < 5°), and hip dysplasia (a Tonnis acetabular angle >14° and a lateral centre-edge angle of Wiberg <20°). Pre-existing radiographic signs of pathology were present in a large proportion of hips with low grade (Tonnis grade 1–2) arthritis. There is a group of patients who presented with more advanced osteoarthritis in which we suspect abnormal bone morphology to be a causative factor but, for example, neck osteophytes obscure the diagnosis of a primary cam lesion. Our findings corroborate those of Harris and Ganz. Impingement is radiographically detectable in a large proportion of patients who present with early arthritis of the hip, and therefore we agree that it is a likely pre-cursor for osteoarthritis. Treatments directed at reducing hip impingement may stifle the progression of osteoarthritis


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 238 - 238
1 Jun 2012
Tamaki T
Full Access

Background. We have often experienced a change of the tone of the hammering sound during the press-fit implantation of cementless acetabular components in total hip arthroplasty (THA). The tone of the impact sound before the press-fit of acetabular components seems to differ from the tone after the press-fit. This change of tone may depend on the accuracy of the fit of the acetabular component, or it may simply be a subjective perception. The aim of this study is to evaluate the impact sounds in the press-fit implantation of cementless acetabular components. Methods. The hammering sounds in press-fit implantation of acetabular components were studied intraoperatively in 22 patients (28 hips) who underwent primary THA for treatment of advanced osteoarthritis. All operations were performed via the direct anterior approach in a supine position. The hemispherical titanium-alloy acetabular component (TriAD; stryker) was implanted in all patients. A sound level meter (NA-28; RION) was used to record and analyze the sounds. The hammering sounds of the first three hits and last three hits were recorded as the “before press-fit” and “after press-fit” sound samples, respectively. A frequency analysis was then performed at the point of peak sound pressure in each sample. Results. The dominant frequency of the impact sounds was equal to or lower than 1 kHz in 20% of the before press-fit samples and 76% of the after press-fit samples, and equal to or higher than 4 kHz in 69% of the before press-fit samples and 21% of the after press-fit samples. The frequency of the impact sounds changed significantly (p<0.01) during the press-fit implantation. Conclusion. The frequency of the impact sound changed significantly during the press-fit implantation of cementless acetabular components. We conclude that an intraoperative evaluation of the impact sound might help to improve accuracy when implanting the acetabular component


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 67 - 67
1 Jun 2012
Gado I Tarabichi S
Full Access

INTRODUCTION. The majority of implants available in the market today were designed to allow for a flexion up to 130 degree angle. The LPS Mobile Flex was designed to accommodate deep flexion, up to 160 degree angle. The purpose of this study is to evaluate the clinical result of the LPS Mobile Flex knee. MATERIALS AND METHODS. From January 1999 to February 200, 1043 (one thousand and forty three) surgeries were performed on patients treated for advanced osteoarthritis. All the surgeries were carried out by the same surgeon. The majority of the patients had bilateral total knee replacements simultaneously. Mobile and fixed implants were used. Pre-operative ranges of motion were documented on lateral x-ray. Patients were considered to have full flexion if they were able to flex the knee to at least 140 degree and sit on the ground with calf touching thigh for at least one minute. Data were processed at University of Dundee. RESULTS. 67% obtained full flexion as defined above. The majority of the cases with full flexion had full movement pre-operatively; except for 63 cases. Average range of motion was much better than University of Dundee data base. Complications included; 2 cases of peroneal nerve palsy, three of dislocation, and two of infection, a case of rupture of MCL ligament, a case of intra-operative tibial plateau fracture, 2of supracondylar femur fracture and 4 patella clunck. CONCLUSION. The LPS Flex Implant had a similar complication rate to those reported by other series. There was no complication that could be specifically attributed to deep flexion. However it should be stressed that this exceptional result has to do mainly with careful patient selection


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_13 | Pages 28 - 28
1 Nov 2015
Haddad F
Full Access

Total knee replacement (TKR) is considered the “gold standard” treatment for advanced osteoarthritis (OA) of the knee with good survivorship and functional outcomes. However up to 20% of patients undergoing TKR may have unicompartmental disease only. Treatment options for medial compartment arthritis can include both unicompartmental knee replacements (UKR) and TKR. While some surgeons favor TKR with a proven track record, others prefer UKR due to more normal joint kinematics, better proprioception and better motion. There is also a higher rate of return to sports amongst patients with UKR compared to TKR. When considering all knee procedures, partial knee replacements account for 7–9%, primary TKRs for 83–88%, and revision knee replacements for 5–8%. Unicompartmental Knee Replacements comprise more than 90% of all partial knee replacement procedures. Proponents of UKR cite as advantages the preservation of normal knee kinematics, lower peri-operative morbidity, blood loss and infection risk compared with TKRs, as well as accelerated patient rehabilitation and recovery. However, partial knee replacements have a higher rate of revision than TKRs. This may be partly because they are inserted in patients with higher expectations, and partly because they are easier to revise. As a result, the volume of UKRs implanted has diminished over time and continues to decline. We compared patient reported outcomes, satisfaction and perception of normality of the knee post-operatively between UKR and TKR. A single unit and single surgeon series of patients were recruited. Data was collated for 68 well-matched patients with more than 24 months follow-up. UKR was undertaken in patients with isolated medial compartment osteoarthritis; stable ACL and less than grade 3 lateral patellar changes of the Outerbridge classification. TKR was undertaken for the rest. The patients were assessed with validated knee scores including the Total Knee Function Questionnaire (TKFQ) which focuses on recreational and sporting outcomes as well as activities of daily living (ADL). Patient satisfaction and perception of knee normality was measured on a visual analogue scale. Thirty-four patients with a TKR and 34 patients with a UKR were analyzed. The average ages in the TKR and UKR groups were 69.25 and 67.26 years, respectively. The patients were well-matched for demographics and had equivalent pre-operative morbidities and scores. The UKR group had better WOMAC (p=0.003), SF36 (physical: p<0.001 mental: p=0.25), Oxford knee (p<0.001) and Knee Society scores (p=0.002, function: p<0.001). The UKR group showed better outcomes in the TKFQ including exercise and sport (p= 0.02), movement and lifestyle (p=0.02) and the ADL (p=0.002). There was, however, no difference in patient satisfaction scores (p=0.41) and perception of how normal the knee felt between the two groups (p=0.99). A UKR procedure confers better functional outcome in terms of recreation and sport compared to TKR procedures. While UKR is an appropriate choice in the elderly yet active patient with unicompartmental knee arthritis, satisfaction is similar to that of patients with a TKR reflecting higher pre-operative expectations. We believe that in appropriate centers, the UKR procedure is associated with excellent outcomes. UKR should have a secure place in the knee arthroplasty armamentarium provided current knowledge regarding patient selection and surgical technique is followed