header advert
Results 1 - 11 of 11
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 40 - 40
10 May 2024
Zhang J Miller R Chuang T
Full Access

Introduction

Distal femur fractures have traditionally been stabilized with either lateral locking plate or retrograde intramedullary nail. Dual-plates and nail-plate combination fixation have the theoretical biomechanical advantage, faster union and allows patients to weight bear immediately.

The aim of this study is to compare single vs combination fixation, and evaluate outcomes and complications.

Method

We retrospectively reviewed all patients over 60, admitted to Christchurch Hospital, between 1st Jan 2016 and 31st Dec 2022, with an AO 33A/33B/33C distal femur fracture. Patient demographics, fracture characteristics, operation details, and follow up data were recorded.

Primary outcomes are union rate, ambulatory status at discharge, and surgical complications. Secondary outcomes include quality of reduction, operation time and rate of blood transfusions.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 59 - 59
10 Feb 2023
Hancock D Morley D Wyatt M Roberts P Zhang J van Dalen J
Full Access

When removing femoral cement in revision hip surgery, creating an anterior femoral cortical window is an attractive alternative to extended trochanteric osteotomy. We describe our experience and evolution of this technique, the clinical and radiological results, and functional outcomes.

Between 2006 and 2021 we used this technique in 22 consecutive cases at Whanganui Hospital, New Zealand. The average age at surgery was 74 years (Range 44 to 89 years). 16 cases were for aseptic loosening: six cases for infection.

The technique has evolved to be more precise and since 2019 the combination of CT imaging and 3-D printing technology has allowed patient-specific (PSI) jigs to be created (6 cases). This technique now facilitates cement removal by potentiating exposure through an optimally sized anterior femoral window.

Bone incorporation of the cortical window and functional outcomes were assessed in 22 cases, using computer tomography and Oxford scores respectively at six months post revision surgery. Of the septic cases, five went onto successful stage two procedures, the other to a Girdlestone procedure.

On average, 80% bony incorporation of the cortical window occurred (range 40 −100%). The average Oxford hip score was 37 (range 22 – 48). Functional outcome (Oxford Hip) scores were available in 11 cases (9 pre-PSI jig and 2 using PSI jig). There were two cases with femoral component subsidence (1 using the PSI jig).

This case series has shown the effectiveness of removing a distal femoral cement mantle using an anterior femoral cortical window, now optimized by using a patient specific jig with subsequent reliable bony integration, and functional outcomes comparable with the mean score for revision hip procedures reported in the New Zealand Joint Registry.


Bone & Joint Open
Vol. 2, Issue 2 | Pages 111 - 118
8 Feb 2021
Pettit M Shukla S Zhang J Sunil Kumar KH Khanduja V

Aims

The ongoing COVID-19 pandemic has disrupted and delayed medical and surgical examinations where attendance is required in person. Our article aims to outline the validity of online assessment, the range of benefits to both candidate and assessor, and the challenges to its implementation. In addition, we propose pragmatic suggestions for its introduction into medical assessment.

Methods

We reviewed the literature concerning the present status of online medical and surgical assessment to establish the perceived benefits, limitations, and potential problems with this method of assessment.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_7 | Pages 30 - 30
1 Jul 2020
Faizan A Zhang J Scholl L
Full Access

Iliopsoas tendonitis after total hip arthroplasty (THA) can be a considerable cause of pain and patient dissatisfaction. The optimal cup position to avoid iliopsoas tendonitis has not been clearly established. Implant designs have also been developed with an anterior recess to avoid iliopsoas impingement. The purpose of this cadaveric study was to determine the effect of cup position and implant design on iliopsoas impingement.

Bilateral THA was performed on three fresh frozen cadavers using oversized (jumbo) offset head center revision acetabular cups with an anterior recess (60, 62 and 66 mm diameter) and tapered wedge primary stems through a posterior approach. A 2mm diameter flexible stainless steel cable was inserted into the psoas tendon sheath between the muscle and the surrounding membrane to identify the location of the psoas muscle radiographically. CT scans of each cadaver were imported in an imaging software. The acetabular shells, cables as well as pelvis were segmented to create separate solid models of each. The offset head center shell was virtually replaced with an equivalent diameter hemispherical shell by overlaying the outer shell surfaces of both designs and keeping the faces of shells parallel. The shortest distance between each shell and cable was measured. To determine the influence of cup inclination and anteversion on psoas impingement, we virtually varied the inclination (30°/40°/50°) and anteversion (10°/20°/30°) angles for both shell designs.

The CT analysis revealed that the original orientation (inclination/anteversion) of the shells implanted in 3 cadavers were as follows: Left1: 44.7°/23.3°, Right1: 41.7°/33.8°, Left2: 40/17, Right2: 31.7/23.5, Left3: 33/2908, Right3: 46.7/6.3. For the offset center shells, the shell to cable distance in all the above cases were positive indicating that there was clearance between the shells and psoas. For the hemispherical shells, in 3 out of 6 cases, the distance was negative indicating impingement of psoas. With the virtual implantation of both shell designs at orientations 40°/10°, 40°/20°, 40°/30° we found that greater anteversion helped decrease psoas impingement in both shell designs. When we analyzed the influence of inclination angle on psoas impingement by comparing wire distances for three orientations (30°/20°, 40°/20°, 50°/20°), we found that the effect was less pronounced. Further analysis comparing the offset head center shell to the conventional hemispherical shell revealed that the offset design was favored (greater clearance between the shell and the wire) in 17 out of 18 cases when the effect of anteversion was considered and in 15 out of 18 cases when the effect of inclinations was considered.

Our results indicate that psoas impingement is related to both cup position and implant geometry. For an oversized jumbo cup, psoas impingement is reduced by greater anteversion while cup inclination has little effect. An offset head center cup with an anterior recess was effective in reducing psoas impingement in comparison to a conventional hemispherical geometry. In conclusion, adequate anteversion is important to avoid psoas impingement with jumbo acetabular shells and an implant with an anterior recess may further mitigate the risk of psoas impingement.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 63 - 63
1 Jul 2020
Zhang J Zhao G Li F Wang JH
Full Access

Tendinopathy is one of the most common orthopaedic pathological conditions characterized by tendon degenerative changes. Excessive mechanical loading is considered as a major causative factor in the development of tendinopathy, but the mechanisms of pathogenesis remain unclear. High mobility group box-1 (HMGB1), a potent inflammatory mediator when released into the matrix, has been identified in the early stage tendinopathy patients. Since the release and contribution of HMGB1 in tendinopathy development due to mechanical overloading is unknown, we investigated the role of HMGB1 in tendinopathy using a mouse intensive treadmill running (ITR) model and injection of glycyrrhizin (GL), a specific inhibitor of HMGB1.

A total of 48 mice were divided into four groups, Cage Control group: The animals were allowed to move freely in their cage, GL group: The animals were received daily IP injection of GL (50 mg/kg body weight) for 24 weeks, ITR group: The animals ran on treadmill at 15 meters/min for three h/ day, five days a week for 12 or 24 weeks, GL+ITR group: The animals ran the same protocol as that of ITR group plus daily IP injection of GL for 12 or 24 weeks. Six mice/group were sacrificed at 12 or 24 weeks and the Achilles and patellar tendon tissues were harvested and used for histochemical staining and immunostaining.

Mechanical overloading induced HMGB1 released from the cell nuclei to the matrix (Fig. 1a, b) caused tendon inflammation (Fig. 1c, d) and led to tendon degenerative changes (Fig. 1e-j). After 12 weeks of ITR, the tendon tissue near the bone insertion site showed typical tendinopathic changes in cell shape, accumulation of glycosaminoglycans (GAG) (Fig. 1e, f), and increase in SOX-9 staining (Fig. 1g-j). After 24 weeks ITR, the distal site of Achilles tendon showed considerable changes in cell shape (Fig. 2A, g, arrows), which is round compared to more elongated in the control and GL groups (Fig. 2A, e, f). However, daily treatment with GL prior to ITR blocked the cell shape change (Fig. 2A, h) and, ITR induced extensive GAG accumulation in ITR group (Fig. 2B, bottom panel). Furthermore, GL inhibited ITR-induced expression of chondrogenic markers (SOX-9 and collagen II) in the tendons (Fig. 3).

Our results showed that mechanical overloading-induced HMGB1 plays a critical role in the development of tendinopathy by initiating tendon inflammation and eventual degeneration characterized by the presence of chondrocyte-like cells, accumulation of proteoglycans, high levels of collagen type II production, and chondrogenic marker SOX-9 expression. These results provide the first evidence for the role of HMGB1 as a therapeutic target to prevent tendinopathy before its onset and block further development at its early inflammation stages. The inhibition of tendinopathy development by GL administration in this study also suggests the putative therapeutic potential of this natural triterpene that is already in clinical use to treat other inflammation-related diseases.

For any figures or tables, please contact authors directly.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 59 - 59
1 Feb 2020
Zhang J Bhowmik-Stoker M Yanoso-Scholl L Condrey C Marchand K Marchand R
Full Access

Introduction

Valgus deformity in an end stage osteoarthritic knee can be difficult to correct with no clear consensus on case management. Dependent on if the joint can be reduced and the degree of medial laxity or distension, a surgeon must use their discretion on the correct method for adequate lateral releases. Robotic assisted (RA) technology has been shown to have three dimensional (3D) cut accuracy which could assist with addressing these complex cases. The purpose of this work was to determine the number of soft tissue releases and component orientation of valgus cases performed with RA total knee arthroplasty (TKA).

Methods

This study was a retrospective chart review of 72 RATKA cases with valgus deformity pre-operatively performed by a single surgeon from July 2016 to December 2017. Initial and final 3D component alignment, knee balancing gaps, component size, and full or partial releases were collected intraoperatively. Post-operatively, radiographs, adverse events, WOMAC total and KOOS Jr scores were collected at 6 months, 1 year and 2 year post-operatively.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 76 - 76
1 Feb 2020
Zhang J Sawires A Matzko C Sodhi N Ehiorobo J Mont M Hepinstall M
Full Access

Background

Manually instrumented knee arthroplasty is associated with variability in implant and limb alignment and ligament balance. When malalignment, patellar maltracking, soft tissue impingement or ligament instability result, this can lead to decreased patient satisfaction and early failure. Robotic technology was introduced to improve surgical planning and execution. Haptic robotic-arm assisted total knee arthroplasty (TKA) leverages three-dimensional planning, optical navigation, dynamic intraoperative assessment of soft tissue laxity, and guided bone preparation utilizing a power saw constrained within haptic boundaries by the robotic arm. This technology became clinically available for TKA in 2016. We report our early experience with adoption of this technique.

Methods

A retrospective chart review compared data from the first 120 robotic-arm assisted TKAs performed December 2016 through July 2018 to the last 120 manually instrumented TKAs performed May 2015 to January 2017, prior to introduction of the robotic technique. Level of articular constraint selected, surgical time, complications, hemoglobin drop, length of stay and discharge disposition were collected from the hospital record. Knee Society Scores (KSS) and range of motion (were derived from office records of visits preoperatively and at 2-weeks, 7-weeks and 3-month post-op. Manipulations under anesthesia and any reoperations were recorded.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 44 - 44
1 Feb 2020
Zhang J Bhowmik-Stoker M Yanoso-Scholl L Condrey C Marchand K Hitt K Marchand R
Full Access

Introduction

Studies have shown that dissatisfaction following TKA may stem from poor component placement and iatrogenic factors related to variability in surgical execution. A CT-based robotic assisted system (RA) allows surgeons to dynamically balance the joint prior to bone resection. This study aimed to determine if this system could improve TKA planning, reduce soft tissue releases, minimize bone resection, and accurately predict component size in varus knee.

Method

Four hundred and seventy four cases with varus deformity undergoing primary RATKA were enrolled in this prospective, single center and surgeon study. Patient demographics and intraoperative surgical details were collected. Initial and final 3-dimensional alignment, component position, bone resection depths, use of soft tissue releases, knee balancing gaps, and component size were collected intraoperatively. WOMAC and KOOS Jr. scores were collected 6 months, and 1 year postoperatively. Descriptive statistics were applied to determine the changes in these parameters between initial and final values.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 60 - 60
1 Feb 2020
Zhang J Persohn S Bhowmik-Stoker M Otto J Paramasivam M Wahdan A Choplin R Territo P
Full Access

Introduction

Component position and overall limb alignment following Total Knee Arthroplasty (TKA) have been shown to influence device survivorship and clinical outcomes. However current methods for measuring post-operative alignment through 2D radiographs and CTs may be prone to inaccuracies due to variations in patient positioning, and certain anatomical configurations such as rotation and flexion contractures. The purpose of this paper is to develop a new vector based method for overall limb alignment and component position measurements using CT. The technique utilizes a new mathematical model to calculate prosthesis alignment from the coordinates of anatomical landmarks. The hypothesis is that the proposed technique demonstrated good accuracy to surgical plan, as well as low intra and inter-observer variability.

Methods

This study received institutional review board approval. A total of 30 patients who underwent robotic assisted TKA (RATKA) at four different sites between March 2017 and January 2018 were enrolled in this prospective, multicenter, non-randomized clinical study. CT scans were performed prior to and 4–6 weeks post-operatively. Each subject was positioned headfirst supine with the legs in a neutral position and the knees at full extension. Three separate CT scans were performed at the anatomical location of the hip, knee, and ankle joint. Hip, knee, and ankle images were viewed in 3D software and the following vertices were generated using anatomical landmarks: Hip Center (HC), Medial Epicondyle Sulcus (MES), Lateral Epicondyle (LE), Femur Center (FC), Tibia Center (TC), Medial Malleolus (MM), Lateral Malleolus (LM), Femur Component Superior (FCS), Femur Component Inferior (FCI), Coronal Femoral Lateral (CFL), Coronal Femoral Medial (CFM), Coronal Tibia Lateral (CTL), and Coronal Tibia Medial (CTM). Limb alignment and component positions were calculated from these vertices using a new mathematical model.

The measurements were compared to the surgeons’ operative plan and component targeted positions for accuracy analysis. Two analysts performed the same measurements separately for inter-observer variability analysis. One of the two analysts repeated the measurements at least 30 days apart to assess intra-observer variability. Correlation analysis was performed on the intra-observer analysis, while Bland Altman analysis was performed on the inter-observer analysis.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 43 - 43
1 Feb 2020
Mont M Kinsey T Zhang J Bhowmik-Stoker M Chen A Orozco F Hozack W Mahoney O
Full Access

Introduction

Component position and overall limb alignment following total knee arthroplasty (TKA) have been shown to influence prosthetic survivorship and clinical outcomes. Robotic-assisted (RA) total knee arthroplasty has demonstrated improved accuracy to plan in cadaver studies compared to conventionally instrumented (manual) TKA, but less clinical evidence has been reported.

The objective of this study was to compare the three-dimensional accuracy to plan of RATKA with manual TKA for overall limb alignment and component position.

Methods

A non-randomized, prospective multi-center clinical study was conducted to compare RATKA and manual TKA at 4 U.S. centers between July 2016 and August 2018. Computed tomography (CT) scans obtained approximately 6 weeks post-operatively were analyzed using anatomical landmarks. Absolute deviation from surgical plans were defined as the absolute value of the difference between the CT measurements and surgeons’ operative plan for overall limb, femoral and tibial component mechanical varus/valgus alignment, tibial component posterior slope, and femoral component internal/external rotation. We tested the differences of absolute deviation from plan between manual and RATKA groups using stratified Wilcoxon tests, which controlled for study center and accounted for skewed distributions of the absolute values. Alpha was 0.05 two-sided. At the time of this abstract, data collections were completed for two centers (52 manual and 58 RATKA).


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 147 - 147
1 Feb 2020
Yang D Huang Y Zhou Y Zhang J Shao H Tang H
Full Access

Aims

The incidence of thigh pain with the short stem varies widely across different studies. We aimed to evaluate the incidence and characteristics of post-operative thigh pain after using a particular bladed short stem and its potential risk factors.

Patients and Methods

We respectively reviewed 199 consecutive patients who underwent unilateral total hip replacement using the Tri-lock stem from 2013–2016, of which 168 patients were successfully followed up with minimum two year clinical follow-up. All information about thigh pain and pre- and postoperative HHS score were gathered and all preoperative and immediate postoperative radiographs were available for review. Any complications were recorded.