header advert
Results 1 - 14 of 14
Results per page:
Bone & Joint Research
Vol. 8, Issue 3 | Pages 136 - 145
1 Mar 2019
Cerquiglini A Henckel J Hothi H Allen P Lewis J Eskelinen A Skinner J Hirschmann MT Hart AJ

Objectives

The Attune total knee arthroplasty (TKA) has been used in over 600 000 patients worldwide. Registry data show good clinical outcome; however, concerns over the cement-tibial interface have been reported. We used retrieval analysis to give further insight into this controversial topic.

Methods

We examined 12 titanium (Ti) PFC Sigma implants, eight cobalt-chromium (CoCr) PFC Sigma implants, eight cobalt-chromium PFC Sigma rotating platform (RP) implants, and 11 Attune implants. We used a peer-reviewed digital imaging method to quantify the amount of cement attached to the backside of each tibial tray. We then measured: 1) the size of tibial tray thickness, tray projections, peripheral lips, and undercuts; and 2) surface roughness (Ra) on the backside and keel of the trays. Statistical analyses were performed to investigate differences between the two designs.


Bone & Joint Research
Vol. 6, Issue 1 | Pages 52 - 56
1 Jan 2017
Hothi HS Kendoff D Lausmann C Henckel J Gehrke T Skinner J Hart A

Objectives

Mechanical wear and corrosion at the head-stem junction of total hip arthroplasties (THAs) (trunnionosis) have been implicated in their early revision, most commonly in metal-on-metal (MOM) hips. We can isolate the role of the head-stem junction as the predominant source of metal release by investigating non-MOM hips; this can help to identify clinically significant volumes of material loss and corrosion from these surfaces.

Methods

In this study we examined a series of 94 retrieved metal-on-polyethylene (MOP) hips for evidence of corrosion and material loss at the taper junction using a well published visual grading method and an established roundness-measuring machine protocol. Hips were retrieved from 74 male and 20 female patients with a median age of 57 years (30 to 76) and a median time to revision of 215 months (2 to 324). The reasons for revision were loosening of both the acetabular component and the stem (n = 29), loosening of the acetabular component (n = 58) and infection (n = 7). No adverse tissue reactions were reported by the revision surgeons.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 11 - 11
1 Mar 2013
Matthies A Suarez A Karbach L Henckel J Skinner J Noble P Hart A
Full Access

There are several component position and design variables that increase the risk of edge loading and high wear in metal-on-metal hip resurfacing (MOM-HR). In this study we combined all of these variables to calculate the ‘contact patch to rim distance’ (CPRD) in patients undergoing revision of their MOM-HR. We then determined whether CPRD was more strongly correlated with component wear and blood metal ion levels, when compared to any other commonly reported clinical variable. This was a retrospective study of 168 consecutively collected MOM-HR retrieval cases. All relevant clinical data was documented, including pre-revision whole blood cobalt and chromium ion levels. Wear of the bearing surfaces was then measured using a roundness-measuring machine. We found four variables to be significantly (p < 0.05) correlated with component wear and blood metal ion levels: (1) cup inclination angle, (2) cup version angle, (3) arc of cover, and (4) CPRD. The correlations between CPRD and both wear and ion levels were significantly stronger than those seen with any other variable (all p < 0.0001). Our study has shown that CPRD is the best predictor of component wear and blood metal ion levels, and may therefore be a useful parameter to help determine those patients who are at risk of high wear and require more frequent clinical surveillance.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 13 - 13
1 Mar 2013
Matthies A Racasan R Bills P Panagiotidou A Blunt L Skinner J Blunn G Hart A
Full Access

Material loss at the head-stem taper junction may contribute to the high early failure rates of stemmed large head metal-on-metal (LH-MOM) hip replacements. We sought to quantify both wear and corrosion and by doing so determine the main mechanism of material loss at the taper. This was a retrospective study of 78 patients having undergone revision of a LH-MOM hip replacement. All relevant clinical data was recorded. Corrosion was assessed using light microscopy and scanning electron microscopy, and graded according to a well-published classification system. We then measured the volumetric wear of the bearing and taper surfaces. Evidence of at least mild taper corrosion was seen in 90% cases, with 46% severely corroded. SEM confirmed the presence of corrosion debris, pits and fretting damage. However, volumetric wear of the taper surfaces was significantly lower than that of the bearing surfaces (p = 0.015). Our study supports corrosion as the predominant mechanism of material loss at the taper junction of LH-MOM hip replacements. Although the volume of material loss is low, the ionic products may be more biologically active compared to the particulate debris arising from the bearing surfaces.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 14 - 14
1 Mar 2013
Hart A Matthies A Racasan R Bills P Panagiotidou A Blunt L Blunn G Skinner J
Full Access

It has been speculated that high wear at the head-stem taper may contribute to the high failure rates reported for stemmed large head metal-on-metal (LH-MOM) hips. In this study of 53 retrieved LH-MOM hip replacements, we sought to determine the relative contributions of the bearing and taper surfaces to the total wear volume. Prior to revision, we recorded the relevant clinical variables, including whole blood cobalt and chromium levels. Volumetric wear of the bearing surfaces was measured using a coordinate measuring machine and of the taper surfaces using a roundness measuring machine. The mean taper wear volume was lower than the combined bearing surface wear volume (p = 0.015). On average the taper contributed 32.9% of the total wear volume, and in only 28% cases was the taper wear volume greater than the bearing surface wear volume. Despite contributing less to the total material loss than the bearing surfaces, the head-stem taper junction remains an important source of implant-derived wear debris. Furthermore, material loss at the taper is likely to involve corrosion and it is possible that the material released may be more biologically active than that from the bearing surface.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 21 - 21
1 Mar 2013
RAHMAN J KAYANI B GILLOTT E BENTLEY G SKINNER J MILES J CARRINGTON R BRIGGS T
Full Access

The Royal National Orthopaedic Hospital has completed an extensive trial of ACI versus MACI in the treatment of symptomatic osteochondral defects of the knee. A new technique has now been proposed which is quicker and easier to perform. This is the Gel-Type Autologous Chondrocyte Transplantation, CHONDRONTM. At Stanmore CHONDRON has been used for the past 17 months. Our aim was to assess the short term functional outcome of patients who have undergone CHONDRONTM using validated outcome scoring questionnaires. We retrospectively reviewed the notes of 43 patients that had undergone CHONDRONTM over one year ago and scored them using the Modified Cincinnati Score, the Visual Analogue Score and the Benltey Stanmore Functional Rating Score.

RESULTS

The mean pre-operative Modified Cincinnati Score was 39.9, which improved to a mean of 59.8 post-operatively. The mean Visual Analogue Score improved from 6.7 to 5.1 post-operatively. The median Bentley Functional Rating Score was 3 pre-operatively and 2 post-operatively.

CONCLUSIONS

These early results show that 76% of the patients who were treated with CHONDRONTM experienced a reduction in pain and improvement in post-operative function. In the patients in whom the symptoms were worse, the deterioration in score could be partly explained by numerous previous procedures on the same site, presence of early osteoarthritis or the presence of multiple osteochondral lesions. This highlights the importance of careful patient selection in order to gain maximum benefit from the procedure.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 69 - 69
1 Aug 2012
Picardo N Nawaz Z Gallagher K Whittingham-Jones P Parratt T Briggs T Carrington R Skinner J Bentley G
Full Access

The aim of this study was to determine whether the clinical outcome of autologous chondrocyte transplantation was dependent on the timing of a high tibial osteotomy in tibio-femoral mal-aligned knees. Between 2000 and 2005, forty-eight patients underwent autologous chondrocyte implantation with HTO performed at varying times relative to the second stage autologous chondrocyte implantation procedure. 24 patients had HTO performed simultaneously with their second stage cartilage transplantation, (the HTO Simultaneous Group). 5 patients had HTO prior to their cartilage procedure, (the HTO pre-ACI Group) and 19 had HTO performed between 1 to 4 years after their second stage cartilage implantation, (the HTO post-ACI Group). There were 29 men and 19 women with a mean age of 37 years (Range 28 to 50) at the time of their second stage procedure.

With average follow-up of 72 months we have demonstrated a significant functional benefit in performing the HTO either prior to or simultaneously with the ACI procedure in the mal-aligned knee. The failure rate in the Post-ACI group was 45% compared to the Pre-ACI and Simultaneous group, with failure rates of 20% and 25%, respectively.

An HTO performed prior to or simultaneously with an autologous chondrocyte implantation procedure in the mal-aligned knee, provides a significant protective effect by reducing the failure rate by approximately 50%.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 120 - 120
1 Aug 2012
Holleyman R Gikas P Tyler P Coward P Carrington R Skinner J Briggs T Miles J
Full Access

Background

The position of the hip-joint centre of rotation (HJC) within the pelvis is known to influence functional outcome of total hip replacement (THR). Superior, lateral and posterior relocations of the HJC from anatomical position have been shown to be associated with greater joint reaction forces and a higher incidence of aseptic loosening. In biomechanical models, the maximum force, moment-generating capacity and the range of motion of the major hip muscle groups have been shown to be sensitive to HJC displacement. This clinical study investigated the effect of HJC displacement and acetabular cup inclination angle on functional performance in patients undergoing primary THR.

Methods

Retrospective study of primary THR patients at the RNOH. HJC displacement from anatomical position in horizontal and vertical planes was measured relative to radiological landmarks using post-operative, calibrated, anterior-posterior pelvic radiographs. Acetabular cup inclination angle was measured relative to the inter-teardrop line. Maximum range of passive hip flexion, abduction, adduction, external and internal rotation were measured in clinic. Patient reported functional outcome was assessed by Oxford Hip Score (OHS) and WOMAC questionnaires. Data analysed using a linear regression model.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 40 - 40
1 Aug 2012
Dhinsa B Nawaz S Gallagher K Carrington R Briggs T Skinner J Bentley G
Full Access

Introduction

Autologous chondrocyte implantation (ACI) is contra-indicated in a joint rendered unstable by a ruptured anterior cruciate ligament (ACL). We present our experience of ACI repair with ACL reconstruction

Methods

Patients underwent arthroscopic examination and cartilage harvesting of the knee. A second operation was undertaken approximately six weeks later to repair the ruptured ACL with hamstring graft or Bone patella-Bone (BPB) and to implant the chondrocytes via formal arthrotomy. Three groups were assessed: Group 1: Simultaneous ACL Reconstruction and ACI; Group 2: Previous ACL Reconstruction with subsequent ACI repair; Group 3: Previously proven partial or complete ACL rupture, deemed stable and not treated with reconstruction with ACI procedure subsequently. Patients then underwent a graduated rehabilitation program and were reviewed using three functional measurements: Bentley functional scale, the modified Cincinnati rating system, and pain measured on a visual analogue scale. All patients also underwent formal clinical examination at review.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 111 - 111
1 Aug 2012
Holleyman R Gikas P Tyler P Coward P Carrington R Skinner J Briggs T Miles J
Full Access

It is known that excessive varus alignment of the femoral stem in total hip replacement (THR) creates a sub-optimal biomechanical environment which is associated with increased rates of revision surgery and component wear. Little is known regarding the effect of femoral stem alignment on patient functional outcome.

Methods

Retrospective study of primary THR patients at the RNOH. Alignment of the femoral stem component in-situ was measured subjectively by a consultant musculoskeletal radiologist in both coronal and sagittal planes using post-operative anterior-posterior and lateral pelvic radiographs. Each THR was grouped into valgus, minor-valgus, neutral, minor-varus or varus coronal plane alignment and posterior, minor-posterior, neutral, minor-anterior or anterior sagittal plane alignment. Patient reported functional outcome was assessed by Oxford Hip Score (OHS) and WOMAC questionnaires. Data analysed using a linear regression model.

Results

90 THRs were studied in 87 patients (55 Female). Mean age at THR=62 (22-86). Mean follow-up=17 months (11-39 months). Median OHS=16, WOMAC=8. Coronal plane alignment of the femoral stem was not associated with any change in OHS (p>0.05) or WOMAC score (p>0.05). Sagittal plane alignment of the femoral stem was not associated with any change in OHS (p>0.05) or WOMAC score (p>0.05).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 12 - 12
1 Aug 2012
Shekkeris A Perera J Bentley G Flanagan A Miles J Carrington R Skinner J Briggs T
Full Access

Articular cartilage implantation (ACI) and associated procedures (MACI = Matrix-assisted cartilage implantation) are now established treatments for osteochondral defects in the knee. The quality of repair in terms of histological appearance is frequently not known, whilst the correlation of histology results with functional outcomes remains undefined. Histological data of the quality of the repair tissue is sparse and a precise classification proved difficult.

This was a single-centre, prospective study. Over 12 years (1998-2010) 406 patients that underwent articular cartilage implantation procedures at our institution (ACI = 170, MACI = 205) had biopsies taken at the 1-2 year interval, in order to assess whether these contained ‘hyaline-like’ cartilage, ‘mixed hyaline-like with fibrocartilage’, fibrocartilage or fibrous tissue alone.

Histological sections of the biopsies were prepared and stained with haematoxylin, eosin and proteoglycan stains and viewed under polarised light. All biopsies were studied by a single histopathologist in a specialist, dedicated musculoskeletal laboratory.

All patients were assessed by the Cincinnati, Bentley and Visual Analogue scores both pre-operatively and at the time of the review.

The findings revealed that 56 patients healed with ‘hyaline-like’ cartilage (14.9%), 103 with ‘mixed’ (27.5%), 179 with fibrocartilage (47.7%) and 37 with fibrous tissue (9.9%).

These findings showed that 42.4% of defects were filled with ‘hyaline-like’ or ‘mixed’ cartilage, with 70% of these achieving a ‘fair’ to ‘excellent’ functional outcome. This was also observed in the fibrocartilage group, where 72% achieved similar results. Predictably 89% of the patients that healed by fibrous tissue had a poor functional outcome.

This study shows that 71% of patients whose osteochondral defects healed by either ‘hyaline-like’, ‘mixed’ or fibrocartilage experienced an improvement in the function. In contrast, only 11% of the patients whose defects filled with fibrous tissue, showed some functional improvement. Additionally, this data indicates the advantage of biopsies in assessing the overall results of cartilage implantation procedures.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 50 - 50
1 May 2012
Underwood RJ Cann PM Skinner J Hart A
Full Access

SUMMARY

The relationship between component position, wear rate and edge loading was investigated for 115 explanted current generation Metal-on-Metal (MoM) hips. Edge wear was detected in: 63% of all hips; and 48% of those with cups positioned within Lewinnek's box.

BACKGROUND

The link between steeply inclined cups (>55 degrees) and edge loading is known for all common hip bearing couples. Edge loading is associated with high rates of wear, and has been linked to premature failure of hips.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 65 - 65
1 May 2012
Hart A Lloyd G Sabah S Sampson B Underwood R Cann P Henckel J Cobb PJ Lewis A Porter M Muirhead-Allwood S Skinner J
Full Access

SUMMARY

We report a prospective study of clinical data collected pre, intra and post operation to remove both cup and head components of 118 failed, current generation metal on metal (MOM) hips. Whilst component position was important, the majority were unexplained failures and of these the majority (63%) had cup inclination angles of less than 55 degrees. Poor biocompatibility of the wear debris may explain many of the failures.

BACKGROUND

Morlock et al reported a retrospective analysis of 267 MOM hips but only 34 head and cup couples (ie most were femoral neck fractures) and without data necessary to define cause of failure. The commonest cause of failure in the National Joint Registry (NJR) is unexplained.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 28 - 28
1 May 2012
Masters J Sandison A Diss T Lali F Skinner J Hart A
Full Access

Metal-on-metal (MOM) hip resurfacings release chromium and cobalt wear debris into the surrounding joint. The hip tissue taken from failed MOM hips shows specific histological features including a subsurface band-like infiltrate of macrophages with particulate inclusions, perivascular lymphocytic infiltrate and fibrin exudation. This tissue response has been called Aseptic Lymphocytic Vasculitis Associated Lesion (ALVAL).

There is a recognised carcinogenic potential associated with hexavalent chromium and epidemiological data from first generation MOM arthroplasties may suggest an increased incidence of haematological malignancy. The ALVAL type reaction includes a marked proliferation of lymphocytes in the perivascular space and thorough investigation of this lymphocytic response is warranted.

This study aims to further characterise the lymphocytic infiltrate using immunohistochemistry and to test clonality using polymerase chain reaction (PCR).

Tissues from revised all cause failed MOM hip arthroplasties (n=77) were collected and analysed initially using routine H&E staining. Those that met the diagnostic criteria of ALVAL described above (n=34) were further stained with a panel of immunohistochemical markers (CD3, CD4, CD8 (T-cell markers) and CD20 (B-cell marker)). 10 representative ALVAL cases were selected and sent for gene rearrangement studies using PCR to determine whether the lymphocytes were polyclonal or monoclonal in nature.

The analysis of the lymphocytic aggregates in ALVAL, showed a mixed population of B and T cells. Within the aggregates, there was a predominance of B cells (CD20) over T cells (CD3). Of the 10 cases which were analysed by PCR, 7 were suitable for interpretation. None of these cases showed evidence of monoclonal lymphocyte proliferation.

The carcinogenic potential of wear debris from MOM hips, particularly affecting the haematopoietic system should be investigated. This study has shown a predominantly B-lymphocyte response in tissues surrounding MOM hips which is polyclonal. Although the numbers are small, the study suggests an immune mediated response in MOM hip tissue and excludes a neoplastic proliferation.

However, long term follow up of patients with MOM hips may be prudent.