Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 11 - 11
1 Jan 2018
Saraogi A Lokikere N Siney P Nagai H Purbach B Raut V Kay P
Full Access

Introduction: Revision hip arthroplasty for aseptic loosening of femoral component is successfully treated with impaction bone grafting technique. Owing to easier technique and shorter operative time, distally fixed non-cemented long stems have gained popularity in the present era. However, use of long stems could make subsequent re-revision difficult due to further bone loss. The standard length stem has been often critiqued due to apprehension of peri-prosthetic fracture.

This study aims to determine the long-term outcomes of the impaction bone grafting of the femur for aseptic loosening in revision hip arthroplasty using standard length C-stems. 168 total hip revisions of 162 patients with impaction bone grafting and cemented standard C-stem (done with standardized technique) between 1995 and 2008 at a tertiary referral centre were included. Revisions for infection and segmental bone defects were excluded.

Mean follow-up of the 168 revision hips was 10.5 years (range 5 – 19.1 years). 14 patients (8.3%) were re-revised, reasons being, persistent deep infection (1.8%), repeated dislocations (1.2%), cup loosening (4.8%) and stem loosening (1.2%). Only 1 patient (0.6%) was re-revised due to stem loosening alone. No peri-prosthetic fractures (intra-operative or post-operative) or stem breakage were identified.

Use of standard stem length in hip revisions with impaction bone grafting does not increase the risk of peri-prosthetic fractures, instead, reconstitutes the bone stock. This questions the conventional principle of bypassing the distal cavitation of femur by 2 cortical diameters with the use of long stem. In our experience, a good proximal femur support is key to performance of standard length cemented stems in revision for aseptic loosening irrespective of grade of distal cavitation for cavitatory defects of femur when treated with impaction bone grafting.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_12 | Pages 51 - 51
1 Nov 2015
Highcock A Siney P Wroblewski B Jones HW Raut V
Full Access

Introduction

Severe osteolysis of the femur secondary to aseptic loosening in hip arthroplasty, remains a difficult revision scenario. Multiple techniques have been developed to aid the surgeon, including restoration of bone stock with impaction bone grafting or strut allografts, various distal fixation prostheses and mega-prostheses. Cemented femoral components, with integration of the cement into the cavitations, has largely fallen out of favour. We examined the long-term outcomes with this technique.

Patients/Materials & Methods

Between 1977 and 1990, 109 patients had a cemented stem revision (without bone grafting) for severe femoral osteolysis in the absence of infection. Severe osteolysis was defined as cavitation in a minimum of 4 Gruen zones. Follow-up included functional scoring, radiological assessment and any complications. Further revision and survivorship analysis for stem failure or aseptic loosening of the femoral component were recorded.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 916 - 920
1 Jul 2005
Ebied A Hoad-Reddick DA Raut V

A reduced femoral offset in total hip replacement has been thought to be disadvantageous. We reviewed the results of 54 consecutive primary total hip replacements in 49 patients (mean age of 68 years) performed between August 1990 and December 1994, with a mean follow-up of 8.8 years (sd 2.1). The mean pre-operative femoral offset for these hips was 41 mm (sd 7.4). All patients received a low-offset Charnley stem and a polyethylene cup inserted by a single surgeon.

At their latest follow-up, surviving patients had a significant improvement in the performance of their hip. Three had undergone revision, one each for deep infection, recurrent dislocation and late pain with subluxation. No hips had been revised, or were at risk of revision, for aseptic loosening. The mean annual linear rate of wear was 0.2 mm (sd 0.08) for the whole group. There was no correlation between the pre-operative femoral offset and the post-operative rate of wear. Our survivorship estimate was 91% when revision for any reason was taken as an end-point, but 100% if aseptic loosening was considered as the end-point. Our study demonstrates that a low-offset femoral stem can produce good, medium-term results.