header advert
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 182 - 182
1 Sep 2012
Martinez Carranza N Nurmi-Sandh H Lagerstedt A Hultenby K Berg H Ryd L
Full Access

Single focal grade IV cartilage lesion in the knee has a poor healing capacity. Instead these lesions often progress to severe and generalized osteoarthritis that may result in total knee replacement. Current treatment modalities aim at biological repair and, although theoretically appealing, the newly formed tissue is at the best cartilage-like, often fibrous or fibrocartilaginous. This at the expense of sophisticated laboratory resources, delicate surgery and strict compliance from patients.

An alternative may be small implants of biomaterial inserted to replace the damaged cartilage. We investigated the response of the opposing tibia cartilage to a metallic implant inserted at different depth into the surrounding cartilage level.

Methods

The medial femoral condyle of both knees of 12 sheep, 70–90kg, 2 year of age and from the same breeder, was operated. A metallic implant with an articulating surface of 316L stainless steel, diameter of 7mm, HA plasma sprayed press-fit peg and a tailored radius and contour to the sheep femoral condyle was placed at the most weight-bearing position. The level of the implant was aimed flush, 0,3 and 0,8 mm below surrounding cartilage. The animals were stabled indoors, allowed to move freely and euthanized after 6 and 12 weeks. Postoperatively the knees were high resolution photographed for macroscopic evaluation. The position and depth of the implant were analysed using a laser scan device. Tibial and femoral condyles specimen were decalcified and slices were prepared for microscopic evaluation. Implant position and cartilage damage was assessed from two independent observers using a macroscopic ICRS score and a modified histologic score according to Mankin.

Results

22 tibia condyles showed a variety of cartilage damage ranging from severe damage down to subchondral bone to an almost pristine condition. There was a strong correlation between implant position and damage to opposing cartilage surface. Mankin score correlated significantly with implant position (p<0.001 regression analysis, r2=.45) as did the ICRS score (p<0.001, regression analysis, r2=.67). Implants sitting proud were associated with poor Mankin score. There was no difference between 6-week and 3-months knees.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 5 | Pages 583 - 588
1 May 2009
Rasch A Byström AH Dalén N Martinez-Carranza N Berg HE

Muscle atrophy has been demonstrated in patients suffering from osteoarthritis of the hip, but little is known about muscular recovery after total hip replacement (THR). A total of 20 patients with unilateral osteoarthritis of the hip were assessed before, six months and two years after THR. The cross-sectional area and radiological density of the muscles of the hip, thigh, calf and back were measured using CT. We hypothesised that the muscles would not recover fully after operation.

After two years comparison of the limb with the THR with the healthy limb showed that there was such a reduction in the cross-sectional area in iliopsoas (7.0%; p = 0.006) and the hip adductors (8.4%, p = 0.003) and in the radiological density in gluteus maximus (10.1 Hounsfield units; p < 0.001), gluteus medius/minimus (5.6 Hounsfield units; p = 0.011), iliopsoas (3.9 Hounsfield units; p < 0.001) and the adductors (2.4 Hounsfield units; p = 0.022).

Thus, there was persistent muscle atrophy in muscles acting about the hip two years after THR. We suggest that an earlier operation or a more intensive rehabilitation may reverse these changes.