Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_6 | Pages 36 - 36
1 May 2019
Syed F Magra M Saunders P Ugwuoke A Young S
Full Access

Introduction

Primary fixation in uncemented Total Hip Replacement (THR) is achieved by implanting an appropriately sized stem. Last year, in our pilot study, we classified undersizing & reported the incidence of subsidence & radiolucent lines (RLL) in undersized uncemented stems. Now we report on a larger cohort of patients, reporting undersizing and its association with radiolucent lines and subsidence. Secondarily we report on the effect of using a collar, patients' BMI, and in a smaller group the five-year failure rate.

Methods

A retrospective review of electronic records of 1337 cases who underwent THR using the Corail stem was carried out. 1204 (Collared 1042, Uncollared 162) had a minimum follow up of 1 year, 693 of those had a follow up of at least 5 years. Radiological review was carried out by 2 independent investigators.


The Bone & Joint Journal
Vol. 100-B, Issue 8 | Pages 1010 - 1017
1 Aug 2018
Jain S Magra M Dube B Veysi VT Whitwell GS Aderinto JB Emerton ME Stone MH Pandit HG

Aims

This study aimed to evaluate implant survival of reverse hybrid total hip arthroplasty (THA) at medium-term follow-up.

Patients and Methods

A consecutive series of 1082 THAs in 982 patients with mean follow-up of 7.9 years (5 to 11.3) is presented. Mean age was 69.2 years (21 to 94). Of these, 194 (17.9%) were in patients under 60 years, 663 (61.3%) in female patients and 348 (32.2%) performed by a trainee. Head size was 28 mm in 953 hips (88.1%) or 32 mm in 129 hips (11.9%). Survival analysis was performed and subgroups compared using log rank tests.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_9 | Pages 36 - 36
1 May 2018
Jain S Magra M Dube B Veysi V Whitwell G Aderinto J Emerton M Stone M Pandit H
Full Access

Introduction

Reverse hybrid total hip replacement (THR) offers significant theoretical benefits but is uncommonly used. Our primary objective was to evaluate implant survival with all cause revision and revision for aseptic loosening of either component as endpoints.

Patients/Materials & Methods

Data was collected prospectively on 1, 088 (988 patients) consecutive reverse hybrid THRs. Mean patient age was 69.3 years (range, 21–94) and mean follow-up was 8.2 years (range, 5–11.3). No patients were lost to follow-up. Overall, 194 (17.8%) procedures were performed in patients under 60 years, 666 (61.1%) were performed in female patients and 349 (32.1%) were performed by a trainee. Acetabular components were ultra-high molecular weight polyethylene in 415 (38.1%) hips, highly cross-linked polyethylene in 669 (61.5%) hips and vitamin E stabilised polyethylene in 4 (0.4%) hips. Femoral stems were collared in 757 (69.7%) hips and collarless in 331 (30.3%) hips. Femoral head sizes were 28 mm in 957 (87.9%) hips and 32 mm in 131 (12.1%) hips. Survival analysis was performed using Kaplan Meier methodology. Log rank tests were used to asses differences in survival by age, gender, head size and surgeon grade.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_9 | Pages 38 - 38
1 May 2018
Magra M McConnell J Syed F Saunders P Young S
Full Access

Introduction

Undersizing of an uncemented femoral stem is a post-operative description of a radiograph with unclear clinical importance. It may not always translate into a suboptimal clinical outcome.

Aim

To describe a novel classification system of undersizing in a fully hydroxyapatite coated femoral implant, assess if it could be reliably reported between observers, and describe a simple way to assess the degree of undersizing on an AP radiograph.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 10 - 10
1 Jan 2016
Magra M Bhamra M
Full Access

Introduction

The rapidly expanding aging population in the UK are living longer than ever before, which is reflected by the rising number of relatively fit and healthy people that sustain fracture NOF (neck of femur). According to current NICE (National institute for health clinical excellence) guidelines a large proportion of fracture NOF patients meet the requirements to have a total hip arthroplasty (THA) for this injury. Dislocation rate of THA can be as high as 20% for patients with fracture NOF, which is a disastrous complication in these vulnerable patients. Numerous techniques have been adopted to minimise the risk of dislocation. The use of dual mobility (tripolar) acetabular components is one such strategy with a proven track record in the literature that is employed by surgeons at our institute.

Objectives

To assess the dislocation rate in patients with fracture NOF treated with dual mobility (tripolar) THAs in our unit.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 369 - 369
1 Jul 2008
Magra M Hughes S ElHaj A Maffulli N
Full Access

Background and objectives: Tenocytes change their structure, composition and mechanical properties to adapt to mechanical loading. Voltage gated and mecha-nosensitive ion channels may play a key role in human tenocytes to regulate some or all initial responses to mechanical stimulation. To date, there has been no direct investigation of ion channel expression by human tenocytes.

Methods: Human tenocytes were cultured from patellar tendon samples harvested from five patients undergoing routine total knee replacement surgery (mean age: 66 years; range 63-73 years). RT-PCR, Western Blotting and whole cell electrophysiological studies were performed to investigate the expression of different classes of ion channels within tenocytes.

Results: Human tenocytes express mRNA and protein encoding voltage operated calcium channel (VOCCs) sub-units (Ca alpha 1A, Ca alpha 1C, Ca alpha 1D, Ca alpha2 delta1) and the mechanosensitive tandem pore domain potassium channel (2PK+) TREK-1. They exhibit whole cell currents consistent with the functional expression of these channels. In addition, other ionic currents were detected within these tenocytes consistent with the expression of voltage gated potassium channels, voltage gated sodium channels, and other outwardly rectifying leak currents.

Discussion and conclusions: Human tendon cells show increased levels of intracellular calcium when stress is applied to them. One of the mechanisms by which this occurs is by the influx of extracellular calcium into the cell via ion channels. VOCCs and TREK channels have been implicated in mechanotransduction signalling pathways in numerous connective tissue cell types. This study suggests that these mechanisms may be present in human tenocytes. In addition, human tenocytes may express other channel currents. Ion channels may represent potential targets for the pharmacological management of chronic tendinopathies.