header advert
Results 1 - 4 of 4
Results per page:
The Bone & Joint Journal
Vol. 101-B, Issue 9 | Pages 1151 - 1159
1 Sep 2019
Oike N Kawashima H Ogose A Hatano H Ariizumi T Kaidu M Aoyama H Endo N

Aims

We analyzed the long-term outcomes of patients observed over ten years after resection en bloc and reconstruction with extracorporeal irradiated autografts

Patients and Methods

This retrospective study included 27 patients who underwent resection en bloc and reimplantation of an extracorporeal irradiated autograft. The mean patient age and follow-up period were 31.7 years (9 to 59) and 16.6 years (10.3 to 24.3), respectively. The most common diagnosis was osteosarcoma (n = 10), followed by chondrosarcoma (n = 6). The femur (n = 13) was the most frequently involved site, followed by the tibia (n = 7). There were inlay grafts in five patients, intercalary grafts in 15 patients, and osteoarticular grafts in seven patients. Functional outcome was evaluated with the Musculoskeletal Tumor Society (MSTS) scoring system.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 90 - 90
1 May 2016
Kawashima H Nakano S Yoshioka S Toki S Kashima M Nakamura M Chikawa T Kanematsu Y Sairyo K
Full Access

Flexion contracture sometimes occurs after primary total knee arthroplasty (TKA). In most cases, flexion contracture after TKA gradually improves over time. However, some severe cases require manipulation or revision surgery.

We searched our clinical database for patients who underwent primary TKA at our institution between 2008 and 2015. By reviewing patient records, we identified three patients (one man and two women) with a severe flexion contracture 30° after primary TKA. Although all three patients gained more than 120° in flexion intraoperatively, they developed flexion contracture after discharge from our institution. We performed manipulation under anaesthesia (MUA) for all three cases several months later. The two female patients had improved range of motion (ROM) right after the manipulation. However, one of them regained flexion contracture 1 year after the MUA.

We report the details of the male patient, who had the worst flexion contracture (−60°). An 80-year-old man had right knee osteoarthritis. His history indicated only hypertension. The right knee ROM before the TKA was −20° extension and 135° flexion. His radiographs showed advanced-stage osteoarthritis. We performed cemented TKA (posterior stabiliser design). Three weeks after the operation, his right knee pain improved. The right knee ROM was −10° extension and 100° flexion just before discharge. However, he returned to our institution because of right knee pain and flexion contracture 31 months after the surgery. The flexion contracture gradually worsened without any trauma. When he returned, the right knee ROM was −60° extension and 135° flexion. Manipulation under general anaesthesia was not effective. Therefore, we performed revision TKA immediately. We excised the scar tissue of the posterior knee joint. Then, we shortened the distal femoral end by 1 cm and reduced the size of the femoral component. After the operation, the right knee ROM was improved to −10° flexion and 130° extension.

The reported prevalence of stiffness after TKA was from 1.3% to 13%. Although the deleterious effects of persistent flexion contractures > 15° is well understood, whether they resolve with time or need surgical intervention is controversial. MUA is generally the initial option for patients with flexion contractures, with the possibility of some improvement. If severe flexion contracture remains after manipulation, revision TKA, which may be considered as a useful treatment option, should be considered.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 88 - 88
1 Mar 2013
Kajino Y Kabata T Maeda T Iwai S Kuroda K Fujita K Kawashima H Sanada S Tsuchiya H
Full Access

Introduction

Hip resurfacing arthroplasty has been surgical options in younger and more active patients with osteoarthritis (OA) and osteonecrosis (ON) of the femoral head. Although excellent midterm results of this procedure have been reported, there is a concern about postoperative impingement between the preserved femoral neck and the acetabular component. There were few reports about kinematics after hip resurfacing. Therefore, the purpose of this study was to investigate the postoperative motion analysis after hip resurfacing using a noble dynamic flat-panel detector (FPD) system by which clear sequential images were obtained with low dose radiation exposure.

Materials and methods

11 patients (mean age: 47.8 ± 7.4), 15 hips were included in this study. There were ten men and one woman. The preoperative diagnoses were ON of the femoral head in 10 hips, OA in 3 hips, and others in 2 hips. Mean postoperative follow-up period was 25.1 ± 21.6 months. Femoral anteversion, cup inclination and cup anteversion were measured on computed tomography and plain radiograph. Impingement signs such as the reactive osteophyte formation and divot around the femoral neck were also investigated on the anteroposterior (AP) and lateral radiographs. Sequential images of active and passive flexion motion in 45-degrees semilateral position, and active abduction motion in a supine position were obtained using a noble dynamic FPD system.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 412 - 414
1 Mar 2005
Eimori K Ogose A Hotta T Kawashima H Omori G Endo N

We describe two patients with a diffuse haemangioma of the lower limb complicated by pathological fracture of the femoral shaft, one of whom was treated by a bone graft and immobilisation in a cast, and the other by external fixation and injection of bone marrow. A review of the literature identified difficulty in control of bleeding and obtaining bony union.