Vol. 98-B, Issue SUPP_2 | Pages 43 - 43
1 Jan 2016
Hirayama T Sasaki K Takakubo Y Ito J Takagi M
Full Access

Background

Large head metal on metal total hip arthroplasty MOM THA have been consistently shown substantial improvement in wear performance compared with metal on polyethylene articulations. Large diameter femoral heads theoretically can reduce dislocation risk by increasing range of motion before impingement, increasing prosthetic jump distance. However, early failure associated with adverse local tissue reactions (ALTRs) to metal debris is an emerging problem after MOM THA. The purpose of this study was to evaluate mid-term results of MOM THA.

Materials and Methods

Twenty-five patients, 28 hips were included in this study. The average age of the patients at the time of surgery was 66.9 years. Three patients were men and 22 were women. MOM THAs were performed using 28 PINNACLE Cup system (DepPuy) (C-STEM: 23, S-ROM: 5) with posterior approach and head size of 36mm. Twenty-five primary THAs due to osteoarthritis in 22 cases and rheumatoid arthritis (RA) in one, and two revisions due to recurrent dislocation THA patients, were performed. The average follow up was 56.7 months. Evaluation items are JOA score, cup anteversion /lateral opening angle, and complications. Indication of the system were applied for patients with high risk of dislocation such as recurrent dislocation in primary and/or THAs, posterior pelvic tilt, elderly, RA and mental disorders.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 73 - 73
1 Jan 2016
Naganuma Y Takakubo Y Hirayama T Tamaki Y Oki H Yang S Sasaki K Kawaji H Ishii M Takagi M
Full Access

Introduction

Macrophages phagocytes implant wear debris and produce various cytokines to evoke inflammation and periprosthetic osteolysis of aseptic loosening. It had been reported that expression of Toll-like receptor (TLR) 2 and other TLRs increased in periprosthetic tissues of aseptic loosening. Pathogen-associated molecular patterns (PAMPs) and damaged-associated molecular patterns (DAMPs) have been known as ligands of TLRs and considered to be involved in the osteolytic reactions via TLRs. Another type of immune sensors, nucleotide-binding and oligomerization domain (NOD)-like receptors (NLR) with a pyrin domain 3 (NLRP3) can also recognize PAMPs and DAMPs as their lignds, which has been presumed to participate in the local host response of macrophage cascade via phagocytosis of implant wear particles. However, the contribution of NLRP3 in periprosthetic tissues of aseptic loosening and the correlation between TLR2 and NLRP3 are still unclear.

Materials and methods

TLR1, TLR2, TLR6, NLRP3, TNF-α and IL-1β of macrophages in aseptic loose periprosthetic tissues were immnohistorically evaluated and compared to osteoarthritic synovium. RAW264.7 cells, macrophagic cell line, were stimulated by titanium particles (Ti) and lipoteichoic acid (LTA)-coated Ti. The celluar reaction associated with TLR2 and NLRP3 and the correlation of them were analyzed at mRNA expression levels with small-interfering RNA of Irak2, one of adaptor molecules in TLR2 cascades.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 144 - 144
1 Jan 2016
Sasaki K Ishii M Kawaji H Takakubo Y Tamaki Y Hirayama T Takagi M
Full Access

Background and Purpose

Although the treatment for infected total hip arthroplasty (THA) has been still controversial, some reports suggested two-stage revision THA seems to be more preferable rather than one-stage revision. The purpose of this study is to estimate the outcome of treatment for infected THA in our institutions.

Patients and methods

The medical records of patients who have been underwent surgical treatment for infected THA between 2006 and 2012 in two hospitals and followed more than one year after surgery were reviewed. 34 patients and 35 hips were included. Age at surgery, gender, a period until surgical treatment after diagnosis of infection, method of treatment (debridement, one-stage or two-stage revision THA) and the outcome are estimated for each hips. Remission was defined by the absence of local and systemic sign of implant related infection and the normalization of WBC and C-reactive protein value without antibiotics.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 45 - 45
1 Jan 2016
Takakubo Y Sasaki K Narita A Oki H Naganuma Y Hirayama T Suzuki A Tamaki Y Togashi E Kawaji H Fukushima S Ishii M Takagi M
Full Access

Objectives

Biologic agents (BIO) drastically changed the rheumatoid arthritis (RA) therapy from starting to use biologics at 2003 in Japan. The rate of orthopaedic surgery, especially total joint arthroplasty (TJA) may reflect trends in disease severity, management and health outcomes.

Methods

We surveyed the number and rate of orthopaedic surgeries and TJA in RA treatment with BIO in the last decade, so called BIO-era.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 161 - 161
1 Sep 2012
Sawada Y Sawada H Hirayama T Tomita N
Full Access

Introduction

The tribological performance of grooved surfaces has been thoroughly analyzed, and such surfaces are thought to have great potential for hard-on-hard joint prosthesis. In related research, femtosecond laser-induced periodic surface structures (FLIPSSs) have been well developed to achieve grooved structures with submicron spacing (700nm) and amplitude (200nm). In this study, submicron-scale periodic grooved structures were made on SUS440C using a femtosecond laser, and its tribological performance was evaluated by both a pin-on-plate reciprocating sliding test and a ring-on-disk test.

Method

The pin-on-plate reciprocating test was performed using PAO6 (30.51cP at 37°C) as the lubricant. The pin and plate specimens were made of SUS440C and were polished to a surface roughness of 0.02μm Ra. The pin specimens were columnar in shape, and radial periodic grooved structures (700nm spacing x 200nm amplitude) were formed on the pin's outer periphery (from 4mm to 5mm in diameter).

The ring-on-disk test was performed using lubricants with different viscosity: PAO6 and PAO2 (4.60cP at 37°C). The ring-on-disk specimens were made of SUS440C and were polished to a surface roughness of 0.03μm Ra. Along the surface of the ring specimens, material was removed to create 4 elevated sections at 0°, 90°, 180° and 270°. These 4 sections were then polished and concentric grooved structures (700nm spacing x 200nm amplitude) were created along a 1.4mm circumferential path within each of these areas.