header advert
Results 1 - 2 of 2
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 35 - 35
1 Jun 2023
Shields D Eng K Clark T Madhavani K Coundurache C Fong A Mills E Dennison M Royston S McGregor-Riley J
Full Access

Introduction

Open tibial fractures typically occur as a consequence of high energy trauma in patients of working age resulting in high rates of deep infection and poor functional outcome. Whilst improved rates of limb salvage, avoidance of infection and better ultimate function have been attributed to improved centralisation of care in orthoplastic units, there remains no universally accepted method of definitive management of these injuries. The aim of this study is to the report the experience of a major trauma centre utilising circular frames as definitive fixation in patients sustaining Gustilo-Anderson (GA) 3B open fractures

Materials & Methods

A prospectively maintained database was interrogated to identify all patients. Case notes and radiographs were reviewed to collate patient demographics and injury factors . The primary outcome of interest was deep infection rate with secondary outcomes including time to union and secondary interventions


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 88 - 88
1 Sep 2012
Kang J Wazir A Fong A Joshi S Marjoram T Hussein A Reddy R Ashford RU Godsiff S
Full Access

Objectives

All Polyethylene Tibial components in Total Knee Arthroplasty have been in use for some years, studies showing equivalent results to Total Knee Arthroplasty (TKA) with metal-backed Tibial components at 10 years have shown no significant difference between the two on radiostereometric analysis and revision rates[1].

Post operative patient outcome data using standard metal-backed Tibial components is widely reported in the literature. This study is looking at patient outcomes following All-polyethylene tibial component TKA. We hypothesize that using standard patient outcome measures, an improvement comparable with that expected for metal-backed tibial component TKA will be shown with All-polyethylene tibial component TKA.

Methods

Between August 2006 and August 2008, 229 all-polyethylene tibial component TKA were implanted at the elective orthopedic unit. The choice of implant was entirely dependent on surgeon's preference.

Of the 229 patient's, 225 details were available for review, 27 did not wish to take part in the study and 1 patient died a year following surgery of an unrelated illness. The remaining 197 patients agreed to take part in the study.

The patient's were contacted either in person or over the telephone and asked to completed questionnaires for standard knee scoring.

These included: the Oxford Knee Score (OKS), the WOMAC Score and the SF-12 Score, both pre-operatively and post operatively.