header advert
Results 1 - 11 of 11
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 22 - 22
24 Nov 2023
Jo S Chao C Khilnani T Bostrom M Carli A
Full Access

Aim

Polypropylene (PPE) synthetic mesh is increasingly used in knee arthroplasty surgery to salvage a disrupted extensor mechanism. Despite its clinical success, it is associated with a high rate of periprosthetic joint infection (PJI), which is hypothesized to be caused by bacterial biofilm. The purpose of the current study is to describe the progression of PPE-based biofilm formation over time and to determine if intraoperative antiseptic solutions could be used to effectively remove biofilm when treating PJI.

Method

Commercially available knotted monofilament PPE mesh1 was cut into 10mm circular shape, immersed in tryptic soy broth (TSB) with methicillin-sensitive staphylococcus aureus and cultured individually in 48-well plates for 10 days to elucidate the biofilm grown on mesh over time. At every 24 hours, a triplicate of samples was retrieved and biofilm on the mesh was dislodged by sonicating at 52 kHz for 15 minutes and quantified by counting colony-forming units (CFUs) after overnight growth. The biofilm growth was also verified using scanning electron microscopy.

The effect of saline and antiseptic solutions was verified by exposing 1) 0.05% chlorohexidine gluconate2, 2) acetic acid-based mixture3, 3) diluted povidone-iodine (0.35%), 4) undiluted povidone-iodine (10%)4, and 5) 1:1 combination of 10% povidone-iodine & 3% hydrogen peroxide on immature and mature biofilms for 3 minutes, created by culturing with bacteria for 24 hours and 72 hours respectively. All experiments were performed in quintuples and repeated. Antiseptic treatments that produced a three-log reduction in CFU counts compared to controls were considered clinically significant.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 46 - 46
24 Nov 2023
Fowler M Nocon A Chiu Y Tam K Carli A
Full Access

Aim

Prosthetic joint infection (PJI) is a devastating and costly complication of total joint arthroplasty (TJA). Use of extended oral antibiotic prophylaxis (EOAP) has become increasingly popular in the United States following a highly publicized study (Inabathula et al) from a single center demonstrating a significant protective effect (81% reduction) against PJI in ‘high-risk’ patients. However, these results have not been reproduced elsewhere and EOAP use directly conflicts with current antibiotic stewardship efforts. In order to study the role of EOAP in PJI prevention, consensus is needed for what defines ‘high-risk’ patients. The revision TJA (rTJA) population is an appropriate group to study due to having a higher incidence of PJI. The purpose of the current study was to rigorously determine which preoperative conditions described by Inabathula et al. (referred to as Inabathula criteria (IBC)) confer a higher rate of PJI in patients undergoing aseptic rTJA.

Method

2,256 patients that underwent aseptic rTJA at a single high-volume institution between 2016–2022 were retrospectively reviewed. Patient demographics and comorbidities were recorded to determine if they had 1 or more ‘IBC’, a long list of preoperative conditions including autoimmune diseases, active smoking, body mass index (BMI)>35, diabetes mellitus, and chronic kidney disease (CKD). Reoperation for PJI at 90-days and 1-year was recorded. Chi-squared or Fischer's exact tests were calculated to determine the association between preoperative presence/absence of IBC and PJI. Multivariable logistic regressions were conducted to determine if specific comorbidities within the IBC individually conferred an increased PJI risk.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 25 - 25
1 Jul 2020
Galmiche R Beaulé P Salimian A Carli A
Full Access

Recently, new metallurgical techniques allowed the creation of 3D metal matrices for cementless acetabular components. Among several different products now available on the market, the Biofoam Dynasty cup (MicroPort Orthopedics® Inc., Arlington, TN, USA) uses an ultraporous Titanium technology but has never been assessed in literature. Coping with this lack of information, our study aims to assess its radiological osteointegration at two years in a primary total hip arthroplasty and compares it to a successful contemporary cementless acetabular cup.

This monocentric retrospective study includes 96 Dynasty Biofoam acetabular components implanted between March 2010 and August 2014 with a minimum 2 years radiographic follow-up. Previous acetabular surgery, any septic issue or re-operation for component malposition were exclusion criteria. They were compared to 96 THA using the Trident PSL matched for age, gender, BMI and follow-up. Presence of radiolucencies and sclerotic lines were described on AP pelvis views using the classification of DeLee and Charnley

There was no statistical difference between the two groups concerning demographics and mean follow-up (p> 0.05). Shell's anteversion was similar but inclination was greater in the biofoam group (p=0.006). 27,17% of the Biofoam shells presented radiolucencies in 2 zones or more and 0% of the Trident shells. 11,96% of Biofoam cups showed radiolucencies in the 3 zones of DeLee comparing to 0% of the Trident cups. There was no statistical difference between the Biofoam group (n=54/96) and the Trident PSL group (n=57/96) in pre-operative functional scores for both WOMAC subscales and SF-12. When evaluating last follow-up PROM's, no significant differences were found comparing the entirety of both groups, 56 Biofoam and 51 Trident PSL. No difference was found either when comparing Biofoam patients with ³ 2 zones of radiolucencies (n=15) to the whole Trident group (n=51).

This study raises concerns about radiologic evidence of osteointegration of the Biofoam acetabular cup. Nevertheless, these radiological findings do not find any clinical correlation considering clinical scores. Thus, it may question the real meaning of these high-rated radiolucencies, which at first sight reflect a poorer osteointegration. The first possible limitation with this study is an overinterpretation of the radiographs. Nevertheless, both observers were blinded regarding the patients groups and clinical outcomes and there was a strong inter-observer reliability. Although both cohorts were matched on their demographics and were similar on the cup anteversion, we noticed a slightly lower abduction angle in the Biofoam population. It could reduce the bone-implant coverage area and hence hinders the bony integration, but this difference was small and both groups remained in the Lewinneck security zone. Furthermore, even if patients were matched on age, gender, BMI and follow-up, other variables can influence early osteointegration (smoke status, osteoporosis) and have not been controlled even though we have no reasons to think their distribution could differ in the 2 groups.

The real clinical meaning of these findings remains unknown but serious concerns are raised about the radiographic osteointegration of the Dynasty Biofoam acetabular components. Concerns are all the more lawful that this implants aim to enhance osteointegration.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 95 - 95
1 Mar 2017
White P Carli A Meftah M Alexiades M Windsor R Ranawat A
Full Access

Introduction

Several studies have shown that functional outcomes are similar regardless of being discharged directly to home or to a rehabilitation center after total knee arthroplasty (TKA). Therefore, we sought to determine if there is a difference in patient care or patient satisfaction for patients discharged to in-patient rehabilitation or home-based rehabilitation.

Materials and Methods

Between February and May of 2015, one hundred and seventy one consecutive patients were prospective identified after undergoing TKA by one of three surgeons. At an average of six-weeks post TKA, all patients were asked a patient administered questionnaire to determine if diagnostic testing (ultrasounds, or x-rays) or blood transfusions were performed during the first-six weeks at either home (n=86) or a rehab (n=85) facility.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 69 - 69
1 May 2016
Carli A Lipman J Haas S
Full Access

Introduction

Positioning of a femoral sizing guide has been cited as being a critical intraoperative step during measured-resection based TKA as it determines femoral component rotation. Consequently, modern femoral sizing guides permit surgeons to ‘dial in’ external rotation when placing the guide. Although this feature facilitates guide placement, its effect on posterior femoral condylar resection and flexion gap stability is unknown. This study examines the effect of rotation on posterior femoral condylar resection among different posterior-referencing TKA designs.

Methods

Left-sided posterior-referencing femoral sizing guides and cutting blocks from nine posterior-referencing femoral sizing guides belonging to six TKA manufacturers were collected. Each guide underwent high-resolution photography at a setting of zero, three and greater than three degrees of external rotation. The axis of rotation for each guide was then identified and its location from the posterior condylar axis was recorded (figure). Cutting blocks from each system were then photographed and the amount of posterior condylar resection from the medial and lateral condyles was calculated for each setting of external rotation (figure). The posterior resection was then compared to the standard distal resections for each system.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 70 - 70
1 May 2016
Carli A Warth L Nestor B
Full Access

Introduction

Cementless fixation is the current preferred method for acetabular reconstruction in total hip arthroplasty (THA). Despite promising long-term results among several designs, theoretic concerns regarding the high modulus of elasticity, low friction against bone and low volumetric porosity of contemporary cementless cups have spurred the introduction of novel porous surfaces that are designed to improve osseointegration and decrease aseptic loosening. Although several novel surfaces have been introduced into clinical use over the past decade, very little literature regarding their clinical and radiographic performance exists. The current study investigates the performance of one such novel surface, Tritanium (Stryker, Mahwah, NJ).

Methods

We prospectively evaluated 121 consecutive THAs performed in 94 patients by a single arthroplasty surgeon using the Tritanium Primary Acetabular Component (Stryker, Mahwah, NJ). 109 hips (90.1%) had adequate clinical and radiological follow-up for analysis. Clinical parameters recorded included implant survivorship, Harris Hip Scores, WOMAC and SF-12. Furthermore, radiographs at the 6-week, 1 year and most recent clinical visit were evaluated by two blinded observers for implant position, evidence of radiolucency, sclerosis and component migration.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 27 - 27
1 May 2016
Carroll K Patel A Carli A Cross M Jerabek S Mayman D
Full Access

Introduction

While implant designs and surgical techniques have improved in total knee arthroplasty (TKA), approximately 20% of patients remain dissatisfied. The purpose of this study was to determine if reproduction of anatomic preoperative measurements correlated to improved clinical outcomes in TKA.

Methods

We retrospectively reviewed95 patients (106 knees) who underwent a TKA between 2012 −2013 with a minimum of one year follow-up. All patients had a pre and post-operative SF-12 and WOMAC scores. Pre and 6 week post-operative radiographs were reviewed to compare restoration of coronal plane alignment, maintenance of joint line obliquity, and maintenance of tibial varus. Coronal alignment was defined as the angle formed between the mechanical axis of the femur and the the tibia. Joint line obliquity was defined as the angle between the mechanical axis of the limb and the line which best parallels the joint space at the knee. Tibial varus was compared between the preoperative proximal lateral tibial angle and the angle formed by the mechanical axis of the tibia and tibial component postoperatively.


Introduction

Superficial wound complications can occur in up to 10% of total knee arthroplasty (TKA) patients and have been associated with deep infection. The ideal material for TKA closure should fulfill the following requirements: 1) fast intraoperative application, 2) minimal wound complications and discomfort, and 3) can be removed by patients without a home care visit. We present our experience with a novel, non-invasive, removable skin closure system compared to conventional staple closure.

Methods

We prospectively evaluated 105 consecutive patients who underwent unilateral or bilateral primary TKA and received skin closure consisting of the Zip 16 Surgical Skin Closure System (Zipline) for skin. All procedures were performed a by single surgeon (SBH) using a mini-midvastus approach. All patients were mobilized on the day of surgery and received 2 weeks of Rivaroxaban thromboprophylaxis. Patient demographics, medical comorbidities, in-hospital complications and wound healing and complications during the first 6-week post-operatively were recorded. Data was compared to a previous TKA cohort of 1,001 patients from the same surgeon who received staples for closure and warfarin for thromboprophylaxis.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 134 - 134
1 Sep 2012
Drager J Carli A Matache B Harvey EJ
Full Access

Purpose

Conservative treatment of minimally displaced distal radius fractures (DFR) remains controversial. Circumferential casting (CC) in the acute setting is believed to supply superior support compared to splinting, but is generally cautioned due to the limited capacity of a cast to accommodate ongoing limb swelling possibly leading to complications. However, there is no conclusive data on which to base these beliefs. Moreover, the appropriate management of cast complications while minimizing risk to fracture integrity remains unclear.

This retrospective study of distal radius fractures treated conservatively with circumferential cast in the acute setting aims to: A. Determine demographic, fracture dependant or management risk factors for CC complications. B. Determine the natural history for both patients with CC and those with CC necessitating cast modification.

Method

Hospital records and radiographic data of 316 patients with DRFs treated with CC at a tertiary-care university hospital between the years 2006 to 2009 were reviewed. Our primary outcome was to access risk factors for cast complications including swelling, pressure sores, neuropathies and loss of cast immobilization. Our secondary outcome accessed reduction stability in patients undergoing cast re-manipulation.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 181 - 181
1 Sep 2012
Carli A Kruijt J Alam N Hamdy RC
Full Access

Purpose

Pediatric orthopaedic surgeons encounter referrals from primary care practitioners and pediatricians that are benign in nature or within accepted limitations for physiological musculoskeletal variance. These referrals are believed to be secondary to insufficient pediatric musculoskeletal expertise and consume already limited pediatric orthopaedic resources. To date, our annual CME course dedicated to pediatric musculoskeletal medicine is the only one of its kind in Canada. It includes didactic teaching as well as a clinic of unnecessary referrals in which participants examine patients and receive feedback from consultants. The purpose of this study was to evaluate the impact of a pediatric musculoskeletal CME course on the quality of local outpatient referrals over a four year period.

Method

Retrospective chart reviews were performed to evaluate outpatient referrals at a tertiary orthopaedic center over an eight month period prior to the commencement of an annual CME course (2006–2007) and three years following its initiation (2010). 1041 consecutive referrals from the first time period and 1124 consecutive referrals from the second time period were collected. Referrals for normal conditions within physiological tolerance were identified based on the final clinical diagnosis by the consultant orthopaedic surgeon and the scheduled follow up.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 5 - 5
1 Sep 2012
Carli A Gao C Khayyat-Kholghi M Wang H Li A Ladel C Harvey EJ Henderson J
Full Access

Purpose

Internal fixation of fractures in the presence of osteopenia has been associated with a failure rate as high as 25%. Enhancing bone formation and osseointegration of orthopaedic hardware is a priority when treating patients with impaired bone regenerative capacity. Fibroblast Growth Factor (FGF) 18 regulates skeletal development and could therefore have applications in implant integration. This study was designed to determine if FGF 18 promotes bone formation and osseointegration in the osteopenic FGFR3−/− mouse and to examine its effect on bone marrow derived mesenchymal stem cells (MSCs).

Method

In Vivo: Intramedullary implants were fabricated from 0.4 × 10mm nylon rods coated with 300nm of titanium by physical vapour deposition. Skeletally mature, age matched female FGFR3−/− and wild type mice received bilateral intramedullary femoral implants. Left femurs received an intramedullary injection of 0.1μg of FGF 18 (Merck Serono), and right femurs received saline only. Six weeks later, femurs were harvested, radiographed, scanned by micro CT, and processed for undecalcified for histology. In Vitro: MSCs were harvested from femurs and tibiae of skeletally mature age matched FGFR3−/− and wild type mice. Cells were cultured in Alpha Modified Eagles Medium (αMEM) to monitor proliferation or αMEM supplemented with ascorbic acid and sodium beta-glycerophosphate to monitor differentiation. Proliferation was assessed through cell counts and metabolic activity at days 3, 6 and 9. Differentiation was assessed through staining for osteoblasts and mineral deposition at days 6, 9 and 12.