header advert
Results 1 - 3 of 3
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 42 - 42
1 Sep 2012
Smitham P Khan W Hazlerigg A Bajaj S McCarthy I Calder P
Full Access

Introduction

Patients undergoing limb reconstruction with the Taylor Spatial Frame (TSF) often perceive that their frame is loose due to the rattle they hear when mobilising. Our aim was to determine how much and where this movement is in the various frame/bone constructs currently on the market.

Method

Using standard tibial saw bones three frames (TSF, Ilizarov and Hexapod) were made in an identical fashion. Constructs were cyclically loaded 4 times to 200 N in tension and compression using the Instron MTS. This was repeated three times. A seventh strut was also placed in the TSF construct and the tests repeated. Bones were then removed and the tests repeated for the frames alone.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 45 - 45
1 Sep 2012
Bajaj S Patel S Eastwood D Calder P
Full Access

Aim

To evaluate the results and complications of bone transport in the treatment of massive tibial bone defects, using the Ilizarov method.

Methods

15 patients underwent bone transport using the Ilizarov technique to treat massive tibial bone defects. The average age of the patients was 8.7 years (3–24 years) and the mean bone defect was 10.8 cms. Following a latent period of 1 week, distraction of the transport doughnut was commenced at 1mm/24 hours in 4 quarterly turns. A docking procedure was performed in 7 cases which involved freshening of the bone ends and autogenous bone grafting from the iliac crest. Following docking the fixator was removed once the regenerate had consolidated.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 117 - 117
1 Mar 2012
Bajaj S Tadevosyan V Satish V
Full Access

Aim

To investigate the effect of Tranexamic acid on blood loss associated with Total Knee Replacement Surgery.

Methods

A prospective double blind randomised controlled trial was conducted on 48 patients undergoing unilateral primary cemented total knee replacement. The mean age of the patients was 68 years. Recruitment was based on specific inclusion and exclusion criteria. Patients were randomised to receive either 10 mg/kg of tranexamic acid or a similar volume of normal saline at the time of cementing the prosthesis before deflation of the tourniquet. Both the patient and the surgeon were blinded to the type of injection. The post-operative blood loss was calculated in each case.