header advert
Results 1 - 2 of 2
Results per page:
Applied filters
Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 340 - 340
1 Jul 2011
Ignatiadis I Arapoglou D Pateromihelakis E Psyllakis P Hatzinikolaou N Pananis E Gerostathopoulos N
Full Access

To show the role and effectiveness of semi-constrained total elbow arthroplasty in restoring elbow function in severe, irreversible post-traumatic osseous and chondral injuries.

Eighteen patients, aged 19–80, 11 male and 7 female, suffering from serious, irreversible anatomical and functional lesions of the elbow joint due to previous severe untreated or inadequately treated fractures (T-type transcondylar, trochlear-condylar, open fxs with large bony defects, severe osteochondral, heterotopic ossification in ICU fracture patients). Postop follow up was 9–57 months.

All patients were treated with modular, cemented, semi-constrained linked total elbow arthroplasty. A functional brace was used post-operatively, and motion was permitted on the 3rd post-op day. The patients were allowed a full range of motion at 1 week post-op and they were subjected to vigorous physiotherapy.

Post-op results were evaluated by using Mayo, DASH, quick-DASH scores and measuring grip strength and range of motion. Our results ranged from satisfactory to excellent in 16 patiens, with good strength and wide motion arc (with up to 15o extension-flexion deficit). One old female patient suffered a severe cerebral stroke with a bad outcome. In another young male patient the motion arc reached only 40% of the normal (spasticity, ICU patient with brain injury).

Semi-constrained linked total elbow arthroplasty proves to be an effective method of treatment in severe, irreversible, intraarticular post-traumatic elbow injuries with chondral destruction and grave functional deficit, provided the proper technique is employed and a vigorous rehabilitation program is followed.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 344 - 344
1 Jul 2011
Ignatiadis I Arapoglou D Pateromihelakis E Mpeis K Pananis E Psyllakis P Gerostathopoulos N
Full Access

We prove the importance of the complete osteoligamentary elbow reconstruction and the usefulness of the liga-mentoplasty by palmaris longus combined with other procedures in complex elbow unstable injuries.

17 patients aged between 17 and 72 suffered elbow luxation or subluxation with rupture of the medial collateral ligament, associated with:

Fracture of the radius head,

fracture of the coronoidal process(terrible triade),1) olecranon fractures.

In 3 compaound injuries we had open fractures with Brahial artery lesion, Ulnar nerve pulsy, radial nerve laceration, Brahial plexus injury.

The lesions happened between 2 hours and 2 yrs pre-operatively, caused to work accidents or to traffic accidents with a follow up between 8–62 months. 10 of the injuries were operated almost in emergency by ligamen-toplasty with palmaris longus, coronoidal process fixation with screw or ancor, radial head osteosynthesis or prosthesis. The vascular injuries urgently operated while the nerve lesions left for secondary repair. A functional splint was applied postoperatively, initially fixated between 110–85 degrees. The splint removed 2 months postoperatively, while full rang of motion obtained.

We performed both Mayo clinic, DAS scores and grasp strength force and Range of Motion measurement evaluation procedures

Satisfactory to excellent results have been obtained in 11 cases with stable joints and range of motion with 20 degrees extension-flexion deficit while in I case the instability persited, in another one arrived 50% of the normal range of motion.

The complex elbow injuries with ligamentary instability are effectively treated if except fractures we always repair The medial-anterior ligaments lesion with liga-mentoplasty and ancors.