header advert
Results 1 - 50 of 478
Results per page:
The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 463 - 468
1 Apr 2009
Fukunaga K Kobayashi A Minoda Y Iwaki H Hashimoto Y Takaoka K

The patellar clunk syndrome describes painful catching, grinding or jumping of the patella when the knee moves from a flexed to an extended position after total knee replacement (TKR). The posterior stabilised TKR had been noted to have a higher incidence of this problem. Mobile-bearing posteriorly stabilised TKRs have been introduced to improve patellar tracking and related problems by a mechanism of self-alignment. We evaluated the patellar clunk syndrome in 113 knees in 93 patients with such a TKR at a mean follow-up of 2.3 years (2.0 to 3.2). The syndrome was identified in 15 knees (13.3%). Logistic regression analysis showed that the absolute value of the post-operative angle of patellar tilt was significantly associated with the occurrence of patellar clunk (p = 0.025). Patellar tracking should be carefully checked during surgery


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 4 | Pages 561 - 565
1 May 2002
Akagi M Kaneda E Nakamura T Ueno M Yamanashi W Miyajima H

The Bisurface knee prosthesis (BP) has a posterior stabilising cam (ball-and-socket joint) in the mid-posterior region of the femorotibial joint in an attempt to improve the range of movement. Based on an in vitro weight-bearing study contact areas of the Insall/Burstein 2 (IB2) and the BP knee were compared using pressure-sensitive films. The stability afforded by the cam was evaluated by means of dislocation distances in the vertical and horizontal planes. Significant adverse anterior translation in mid-flexion was not observed with the BP knee since the cam was effective above 60° of flexion. At flexion of 60° or more, the total contact areas were larger, as the cam represented a weight-bearing surface. The dislocation distances for the BP knee compared favourably with those for the IB2 knee. We conclude that the cam of the BP knee allows good movement, stability and wear


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 1 | Pages 100 - 106
1 Jan 2003
Sundararaj GD Behera S Ravi V Venkatesh K Cherian VM Lee V

We present a prospective study of patients with tuberculosis of the dorsal, dorsolumbar and lumbar spine after combined anterior (radical debridement and anterior fusion) and posterior (instrumentation and fusion) surgery. The object was to study the progress of interbody union, the extent of correction of the kyphosis and its maintenance with early mobilisation, and the incidence of graft and implant-related problems. The American Spinal Injury Association (ASIA) score was used to assess the neurological status. The mean preoperative vertebral loss was highest (0.96) in the dorsal spine. The maximum correction of the kyphosis in the dorsolumbar spine was 17.8°. Loss of correction was maximal in the lumbosacral spine at 13.7°. All patients had firm anterior fusion at a mean of five months. The incidence of infection was 3.9% and of graft-related problems 6.5%. We conclude that adjuvant posterior stabilisation allows early mobilisation and rehabilitation. Graft-related problems were fewer and the progression and maintenance of correction of the kyphosis were better than with anterior surgery alone. There is no additional risk relating to the use of an implant either posteriorly or anteriorly even when large quantities of pus are present


Bone & Joint 360
Vol. 10, Issue 5 | Pages 32 - 35
1 Oct 2021


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 37 - 37
7 Aug 2023
Mudiganty S Jayadev C Carrington R Miles J Donaldson J Mcculloch R
Full Access

Abstract. Introduction. Total knee replacement (TKR) in patients with skeletal dysplasia is technically challenging surgery due to deformity, joint contracture, and associated co-morbidities. The aim of this study is to follow up patients with skeletal dysplasia following a TKR. Methodology. We retrospectively reviewed 22 patients with skeletal dysplasia who underwent 31 TKRs at our institution between 2006 and 2022. Clinical notes, operative records and radiographic data were reviewed. Results. Achondroplasia was the most common skeletal dysplasia (8), followed by Chondrodysplasia punctata (7) and Spondyloepiphyseal dysplasia (5). There were fourteen men and eight women with mean age of 51 years (28 to 73). The average height of patients was 1.4 metres (1.16–1.75) and the mean weight was 64.8 Kg (34.3–100). The mean follow up duration was 68.32 months (1–161). Three patients died during follow up. Custom implants were required in twelve patients (38.71%). Custom jigs were utilised in six patients and two patients underwent robotic assisted surgery. Hinged TKR was used in seventeen patients (54.84%), posterior stabilised TKR in nine patients (29.03%), and cruciate retaining TKR in five patients (16.13%). One patient underwent a patella resurfacing for persistent anterior knee pain and another had an intra-operative medial tibial plateau fracture which was managed with fixation. No revisions occurred during the follow up period. Conclusion. Despite the technical challenges and complexity of TKR within this unique patient group, we demonstrate good implant survivorship during the study period. Cross sectional imaging is recommended preoperatively for precise planning and templating


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 118 - 118
2 Jan 2024
Stroobant L Verstraete M Onsem S Victor J Chevalier A
Full Access

Numerous papers present in-vivo knee kinematics data following total knee arthroplasty (TKA) from fluoroscopic testing. Comparing data is challenging given the large number of factors that potentially affect the reported kinematics. This paper aims at understanding the effect of following three different factors: implant geometry, performed activity and analysis method. A total of 30 patients who underwent TKA were included in this study. This group was subdivided in three equal groups: each group receiving a different type of posterior stabilized total knee prosthesis. During single-plane fluoroscopic analysis, each patient performed three activities: open chain flexion extension, closed chain squatting and chair-rising. The 2D fluoroscopic data were subsequently converted to 3D implant positions and used to evaluate the tibiofemoral contact points and landmark-based kinematic parameters. Significantly different anteroposterior translations and internal-external rotations were observed between the considered implants. In the lateral compartment, these differences only appeared after post-cam engagement. Comparing the activities, a significant more posterior position was observed for both the medial and lateral compartment in the closed chain activities during mid-flexion. A strong and significant correlation was found between the contact-points and landmarks-based analyses method. However, large individual variations were also observed, yielding a difference of up to 25% in anteroposterior position between both methods. In conclusion, all three evaluated factors significantly affect the obtained tibiofemoral kinematics. The individual implant design significantly affects the anteroposterior tibiofemoral position, internal-external rotation and timing of post-cam engagement. Both kinematics and post-cam engagement additionally depend on the activity investigated, with a more posterior position and associated higher patella lever arm for the closed chain activities. Attention should also be paid to the considered analysis method and associated kinematics definition: analyzing the tibiofemoral contact points potentially yields significantly different results compared to a landmark-based approach


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 4 - 4
11 Apr 2023
Lynch J Perriman D Scarvell J Pickering M Galvin C Smith P
Full Access

Total knee replacement (TKR) design aims to restore normal kinematics with emphasis on flexion range. The survivorship of a TKR is dependent on the kinematics in six-degrees-of-freedom (6-DoF). Stepping up, such as stair ascent is a kinematically demanding activity after TKR. The debate about design choice has not yet been informed by 6-DoF in vivo kinematics. This prospective randomised controlled trial (RCT) compared kneeling kinematics in three TKR designs. 68 participants were randomised to receive either cruciate retaining (CR-FB), rotating platform (CR-RP) or posterior stabilised (PS-FB) prostheses. Image quality was sufficient for 49 of these patients to be included in the final analysis following a minimum 1-year follow-up. Patients completed a step-up task while being imaged using single-plane fluoroscopy. Femoral and tibial computer-aided design (CAD) models for each of the TKR designs were registered to the fluoroscopic images using bespoke software OrthoVis to generate six-degree-of-freedom kinematics. Differences in kinematics between designs were compared as a function of flexion. There were no differences in terminal extension between the groups. The CR-FB was further posterior and the CR-RP was more externally rotated at terminal extension compared to the other designs. Furthermore, the CR-FB designs was more posteriorly positioned at each flexion angle compared to both other designs. Additionally, the CR-RP design had more external femoral rotation throughout flexion when compared with both fixed bearing designs. However, there were no differences in total rotation for either step-up or down. Visually, it appears there was substantial variability between participants in each group, indicating unique patient-specific movement patterns. While use of a specific implant design does influence some kinematic parameters, the overall patterns are similar. Furthermore, there is high variability indicating patient-specific kinematic patterns. At a group level, none of these designs appear to provide markedly different step-up kinematic patterns. This is important for patient expectations following surgery. Future work should aim to better understand the unique patient variability


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 26 - 26
2 Jan 2024
Jacob A Heumann M Zderic I Varga P Caspar J Lauterborn S Haschtmann D Fekete T Gueorguiev B Loibl M
Full Access

Stand-alone anterior lumbar interbody fusion (ALIF) provides the opportunity to avoid supplemental posterior fixation. This may reduce morbidity and complication rate, which is of special interest in patients with reduced bone mineral density (BMD). This study aims to assess immediate biomechanical stability and radiographic outcome of a stand-alone ALIF device with integrated screws in specimens of low BMD. Eight human cadaveric spines (L4-sacrum) were instrumented with SynFix-LR™ (DePuy Synthes) at L5/S1. Quantitative computed tomography was used to measure BMD of L5 in AMIRA. Threshold values proposed by the American Society of Radiology 80 and 120 mg CaHa/mL were used to differentiate between Osteoporosis, Osteopenia, and normal BMD. Segmental lordosis, anterior and posterior disc height were analysed on pre- and postoperative radiographs (Fig 1). Specimens were tested intact and following instrumentation using a flexibility protocol consisting of three loading cycles to ±7.5 Nm in flexion-extension, lateral bending, and axial rotation. The ranges of motion (ROM) of the index level were assessed using an optoelectronic system. BMD ranged 58–181mg CaHA/mL. Comparison of pre- and postoperative radiographs revealed significant increase of L5/S1 segmental lordosis (mean 14.6°, SD 5.1, p < 0.001) and anterior disc height (mean 5.8mm, SD 1.8, p < 0.001), but not posterior disc height. ROM of 6 specimens was reduced compared to the intact state. Two specimens showed destructive failure in extension. Mean decrease was most distinct in axial rotation up to 83% followed by flexion-extension. ALIF device with integrated screws at L5/S1 significantly increases segmental lordosis and anterior disc height without correlation to BMD. Primary stability in the immediate postoperative situation is mostly warranted in axial rotation. The risk of failure might be increased in extension for some patients with reduced lumbar BMD, therefore additional posterior stabilization could be considered. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 112 - 112
10 Feb 2023
Ross M Vince K Hoskins W
Full Access

Constrained implants with intra-medullary fixation are expedient for complex TKA. Constraint is associated with loosening, but can correction of deformity mitigate risk of loosening?. Primary TKA's with a non-linked constrained prosthesis from 2010-2018 were identified. Indications were ligamentous instability or intra-medullary fixation to bypass stress risers. All included fully cemented 30mm stem extensions on tibia and femur. If soft tissue stability was achieved, a posterior stabilized (PS) tibial insert was selected. Pre and post TKA full length radiographs showed. i. hip-knee-ankle angles (HKAA). ii. Kennedy Zone (KZ) where hip to ankle vector crosses knee joint. 77 TKA's in 68 patients, average age 69.3 years (41-89.5) with OA (65%) post-trauma (24.5%) and inflammatory arthropathy (10.5%). Pre-op radiographs (62 knees) showed varus in 37.0%. (HKAA: 4. o. -29. o. ), valgus in 59.6% (HKAA range 8. o. -41. o. ) and 2 knees in neutral. 13 cases deceased within 2 years were excluded. Six with 2 year follow up pending have not been revised. Mean follow-up is 6.1 yrs (2.4-11.9yrs). Long post-op radiographs showed 34 (57.6%) in central KZ (HKKA 180. o. +/- 2. o. ). . Thirteen (22.0%) were in mechanical varus (HKAA 3. o. -15. o. ) and 12 (20.3%) in mechanical valgus: HKAA (171. o. -178. o. ). Three failed with infection; 2 after ORIF and one with BMI>50. The greatest post op varus suffered peri-prosthetic fracture. There was no aseptic loosening or instability. Only full-length radiographs accurately measure alignment and very few similar studies exist. No cases failed by loosening or instability, but PPF followed persistent malalignment. Infection complicated prior ORIF and elevated BMI. This does not endorse indiscriminate use of mechanically constrained knee prostheses. Lower demand patients with complex arthropathy, especially severe deformity, benefit from fully cemented, non-linked constrained prostheses, with intra-medullary fixation. Hinges are not necessarily indicated, and rotational constraint does not lead to loosening


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 108 - 108
23 Feb 2023
Lee W Foong C Kunnasegaran R
Full Access

Most studies comparing medial pivot to the posterior stabilised (PS) systems sacrifice the PCL. It is unknown whether retaining the PCL in the Medial Congruent (MC) system may provide further benefit compared to the more commonly used PS system. A retrospective review of a single-surgeon's registry data comparing 44 PS and 25 MC with PCL retained (MC-PCLR) TKAs was performed. Both groups had similar baseline demographics in terms of age, gender, body mass index, and American Society for Anaesthesiology score. There was no significant difference in their preoperative range of motion (ROM) (104º±20º vs. 102º±20º,p=0.80), Oxford Knee Score (OKS) (27±6 vs. 26±7,p=0.72), and Knee Society Scoring System (KS) Function Score (KS-FS) (52±24 vs. 56±24,p=0.62). The preoperative KS Knee Score (KS-KS) was significantly lower in the PS group (44±14 vs. 54 ± 18,p<0.05). At 3-months postoperation, the PS group had significantly better OKS (38±6 vs. 36±6,p=0.02) but similar ROM (111º±14º vs. 108º±12º,p=0.25), KS-FS (73±20 vs. 68±23, p=0.32) and KS-KS (87±10 vs. 86±9,p=0.26). At 12-months postoperation, both groups had similar ROM (115º±13º vs. 115º±11º,p=0.99), OKS (41±5 vs. 40±5,p=0.45), KS-FS (74±22vs.78±17,p=0.80), and KS-KS (89±10vs.89±11,p=0.75). There was statistically significant improvement in all parameters at 1-year postoperation (p<0.05). The PS group had significant improvement in all parameters from preoperation to 3-month postoperation (p<0.05), but not from 3-month to 1-year postoperation (p≥0.05). The MC-PCLR group continued to have significant improvement from 3-month to 1-year postoperation (p<0.05). The MC provides stability in the medial compartment while allowing a degree of freedom in the lateral compartment. Preserving the PCL when using MC may paradoxically cause an undesired additional restrain that slows the recovery process of the patients after TKA. In conclusion, compared to MC-PCLR, a PS TKA may expect significantly faster improvement at 3 months post operation, although they will achieve similar outcomes at 1-year post operation


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 105 - 112
1 Jan 2021
Lynch JT Perriman DM Scarvell JM Pickering MR Galvin CR Neeman T Smith PN

Aims. Modern total knee arthroplasty (TKA) prostheses are designed to restore near normal kinematics including high flexion. Kneeling is a high flexion, kinematically demanding activity after TKA. The debate about design choice has not yet been informed by six-degrees-of-freedom in vivo kinematics. This prospective randomized clinical trial compared kneeling kinematics in three TKA designs. Methods. In total, 68 patients were randomized to either a posterior stabilized (PS-FB), cruciate-retaining (CR-FB), or rotating platform (CR-RP) design. Of these patients, 64 completed a minimum one year follow-up. Patients completed full-flexion kneeling while being imaged using single-plane fluoroscopy. Kinematics were calculated by registering the 3D implant models onto 2D-dynamic fluoroscopic images and exported for analysis. Results. CR-FB designs had significantly lower maximal flexion (mean 116° (SD 2.1°)) compared to CR-RP (123° (SD 1.6°)) and PS-FB (125° (SD 2.1°)). The PS-FB design displayed a more posteriorly positioned femur throughout flexion. Furthermore, the CR-RP femur was more externally rotated throughout kneeling. Finally, individual patient kinematics showed high degrees of variability within all designs. Conclusion. The increased maximal flexion found in the PS-FB and CR-RP designs were likely achieved in different ways. The PS-FB design uses a cam-post to hold the femur more posteriorly preventing posterior impingement. The external rotation within the CR-RP design was surprising and hasn’t previously been reported. It is likely due to the polyethylene bearing being decoupled from flexion. The findings of this study provide insights into the function of different knee arthroplasty designs in the context during deep kneeling and provide clinicians with a more kinematically informed choice for implant selection and may allow improved management of patients' functional expectations. Cite this article: Bone Joint J 2021;103-B(1):105–112


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 62 - 62
1 Oct 2019
White PB Satalich J Ranawat AS Ranawat CS
Full Access

Background. The purpose of this study was to evaluate the clinical and radiographic outcomes of the rotating-platform, posterior-stabilized PFC Sigma at fifteen-year follow-up. Methods. Between January 2000 and November 2001, two hundred consecutive patients underwent TKA with a rotating-platform, posterior stabilized total knee arthroplasty with cement. All patients have been followed prospectively and all patients with minimum 12 year follow up were included in this analysis. Forty-nine TKAs were available for our final analysis with a mean follow up of 16.0 years. Results. The improvements in Knee Society pain and function scores were 44 to 83. The 15-year Koos Jr interval scores for cohort was 76.2. The range of motion improved from 111° to 115°. The prevalence of residual pain was 32.5%, painless crepitation was 15% and 5% reporting painful crepitation at 15-year follow up via PROMs. Kaplan-Meier analysis revealed that the survivorship was 100% due to mechanical failure as an endpoint, and 95% as reoperation as an end-point. Conclusions. At fifteen-year follow up, the rotating-platform, posterior stabilized arthroplasty demonstrated excellent survivorship and radiographic results. Peripatellar crepitation, occasionally requiring excision, remains an issue. For figures, tables, or references, please contact authors directly


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 90 - 90
1 Nov 2021
Kowalski E Catelli D Lamontagne M Dervin G
Full Access

Introduction and Objective. Gait variability is the amplitude of the fluctuations in the time series with respect to the mean of kinematic (e.g., joint angles) or kinetic (e.g., joint moments) measurements. Although gait variability increases with normal ageing or pathological mechanisms, such as knee osteoarthritis (OA). The purpose was to determine if a patient who underwent a total knee arthroplasty (TKA) can reduce gait variability. Materials and Methods. Twenty-five patients awaiting TKA were randomly assigned to receive either medial pivot (MP, m=7/f=6, age=62.4±6.2 years) or posterior stabilized (PS, m=7/f=5, age=63.7±8.9 years) implants, and were compared to 13 controls (CTRL, m=7/f=6, age=63.9±4.3 years). All patients completed a gait analysis within one month prior and 12 months following surgery, CTRLs completed the protocol once. A waveform F-Test Method (WFM) was used to compare the variance in knee biomechanics variables at each interval of the gait cycle. Results. Preoperatively, the PS group had greater sagittal knee angle variability compared to the MP (32–58% gait cycle) and CTRL (21–53% gait cycle) groups. Postoperatively, no difference in sagittal knee angle variability existed between any of the groups. Preoperatively, sagittal knee moment variability was greater in the MP (2–39% gait cycle) and PS (5–19% and 42–57% gait cycle) groups compared to the CTRL. Postoperatively, sagittal knee moment was lower in the MP (49–55% gait cycle) and greater in the PS (23–36% gait cycle) compared to the CTRL. Knee power variability was greater preoperatively in the MP (52–61% gait cycle) and PS (52–62% gait cycle) compared to the CTRL. Postoperatively, knee power variability was lower in the MP (17–22% and 45–50% gait cycle) and PS (6–23%, 34–41% and 45–49% gait cycle) compared to the CTRL group. Conclusions. Preoperatively, knee OA patients have greater variability in knee moments than CTRLs during the transition from double-limb support to single-limb support on the affected limb. This indicates knee instability as patients are adopting a gait strategy that refers to knee muscle contraction avoidance. The MP group showed greater knee stability postoperatively as they had lower knee moment and power variability compared to the CTRL. The significance of having less variability than CTRLs is not well understood at this time. Future research on muscle activity is needed to determine if neuromuscular adaptations are causing these reductions in variability after TKA


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 426 - 433
1 Apr 2020
Boettner F Sculco P Faschingbauer M Rueckl K Windhager R Kasparek MF

Aims. To compare patients undergoing total knee arthroplasty (TKA) with ≤ 80° range of movement (ROM) operated with a 2 mm increase in the flexion gap with matched non-stiff patients with at least 100° of preoperative ROM and balanced flexion and extension gaps. Methods. In a retrospective cohort study, 98 TKAs (91 patients) with a preoperative ROM of ≤ 80° were examined. Mean follow-up time was 53 months (24 to 112). All TKAs in stiff knees were performed with a 2 mm increased flexion gap. Data were compared to a matched control group of 98 TKAs (86 patients) with a mean follow-up of 43 months (24 to 89). Knees in the control group had a preoperative ROM of at least 100° and balanced flexion and extension gaps. In all stiff and non-stiff knees posterior stabilized (PS) TKAs with patellar resurfacing in combination with adequate soft tissue balancing were used. Results. Overall mean ROM in stiff knees increased preoperatively from 67° (0° to 80°) to 114° postoperatively (65° to 135°) (p < 0.001). Mean knee flexion improved from 82° (0° to 110°) to 115° (65° to 135°) and mean flexion contracture decreased from 14° (0° to 50°) to 1° (0° to 10°) (p < 0.001). The mean Knee Society Score (KSS) improved from 34 (0 to 71) to 88 (38 to 100) (p < 0.001) and the KSS Functional Score from 43 (0 to 70) to 86 (0 to 100). Seven knees (7%) required manipulations under anaesthesia (MUA) and none of the knees had flexion instability. The mean overall ROM in the control group improved from 117° (100° to 140°) to 123° (100° to 130°) (p < 0.001). Mean knee flexion improved from 119° (100° to 140°) to 123° (100° to 130°) (p < 0.001) and mean flexion contracture decreased from 2° (0° to 15°) to 0° (0° to 5°) (p < 0.001). None of the knees in the control group had flexion instability or required MUA. The mean KSS Knee Score improved from 48 (0 to 80) to 94 (79 to 100) (p < 0.001) and the KSS Functional Score from 52 (5 to 100) to 95 (60 to 100) (p < 0.001). Mean improvement in ROM (p < 0.001) and KSS Knee Score (p = 0.017) were greater in knees with preoperative stiffness compared with the control group, but the KSS Functional Score improvement was comparable (p = 0.885). Conclusion. TKA with a 2 mm increased flexion gap provided a significant improvement of ROM in knees with preoperative stiffness. While the improvement in ROM was greater, the absolute postoperative ROM was less than in matched non-stiff knees. PS TKA with patellar resurfacing and a 2 mm increased flexion gap, in combination with adequate soft tissue balancing, provides excellent ROM and knee function when stiffness of the knee had been present preoperatively. Cite this article: Bone Joint J 2020;102-B(4):426–433


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 42 - 42
1 Oct 2018
McCalden RW Clout A Naudie DD MacDonald SJ Somerville LE
Full Access

Purpose. The success of total knee replacement (TKR) surgery can be attributed to improvements in TKR design, instrumentation, and surgical technique. Over a decade ago oxidized zirconium (OxZr) femoral components were introduced as an alternative bearing surface to cobalt-chromium (CoCr), based on strong in-vitro evidence, to improve the longevity of TKR implants. Early reports have demonstrated the clinical success of this material however no long-term comparative studies have demonstrated the superiority of OxZr implants compared to a more traditional CoCr implant. This study aims to compare long-term survivorship and outcomes in OxZr and CoCr femoral components in a single total knee design. Methods. We reviewed our institutional database to identify all patients whom underwent a TKA with a posterior stabilized OxZr femoral component with a minimum of 10 years of follow-up. These were then matched to patients whom underwent a TKA with the identical design posterior stabilized CoCr femoral component during the same time period by gender, age and BMI. All patients had their patella resurfaced. All patients were prospectively evaluated preoperatively and postoperatively at 6 weeks, 3 months, 12 months, 2 years and every 1 to 2 years thereafter. Prospectively collected clinical outcome measures included, Western Ontario and McMaster Universities osteoarthritis index (WOMAC), Short-Form 12 (SF-12) and Knee Society clinical rating scores (KSCRS). Charts and radiographs were reviewed to determine the revision rates and survivorship (both all cause and aseptic) at 10 years allowing comparison between the two cohorts. Paired analysis was performed to determine if differences existed in patient reported outcomes. Results. There were 194 OxZr TKAs identified and matched to 194 CoCr TKAs. There was no difference in average age (OxZr, 54.2 years; CoCr, 54.4 years), Gender (OxZr, 61.9% female; CoCr, 61.9% female) and average body mass index (OxZr, 35.9 kg/m2; CoCr, 36.4 kg/m2) between the two cohorts. There were no significant differences preoperatively in any of the outcome scores between the two groups (WOMAC (p=0.361), SF-12 (p=0.771) and KSCRS (p=0.161)). Both the SF12 (p=0.787) and WOMAC (p=0.454) were similar between the two groups, however the OxZr TKA cohort had superior KSCRS compared to the CoCr TKA cohort at a minimum of 10 years (173.5 vs. 159.1, p=0.002). With revision for any reason as the end point, there was no significant difference in 10-year survivorship between the two groups (OxZr and CoCr, 96.4%, p=0.898). Similarly, aseptic revisions demonstrated comparable survivorship rates at 10-year between the OxZr (98.9%) and CoCr groups (97.9%) (p=0.404). Conclusion. In this matched cohort study, both groups demonstrated similar improvements in patient reported outcomes, although the OxZr cohort had greater KSCRS scores compared to the CoCr cohort. The reason for this difference is not clear but may represent selection bias, where OxZr implants were perhaps used in more active patients. Implant survivorship, based on revision rates for all causes and/or aseptic reasons, was excellent and similar for both the OxZr and CoCr femoral components at 10 years. Therefore, with respect to implant longevity at the end of the first decade, there appears to be no clear advantage of OxZr compared to CoCr for patients with similar demographics with this specific posterior stabilized TKA design. Further follow-up into the second and third decade may be required to demonstrate if a difference does exist


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 375 - 375
1 Jul 2011
Lamberton T Poutawera V
Full Access

Knee flexion is often decreased in severe arthritis causing pain, and functional limitations in lifestyles and occupations. Newer knee replacement designs offer the possibility of greater knee motion. The objective of our study was to compare the clinical outcomes, in particular the range of motion, in patients treated with a total knee arthroplasty using either a standard posterior stabilized knee prosthesis or a high flexion posterior stabilized knee prosthesis, with regard to return to function within 1 year of surgery. This was a prospective randomized single blinded study. Forty patients were randomly assigned to receive either a standard fixed bearing posterior stabilized or a modified high flexion fixed bearing posterior stabilized Smith & Nephew Genesis II total knee joint replacement. Clinical outcomes were determined from data collected on all patients who were evaluated pre-operatively, at twelve weeks post-operatively, and at one year post-operatively. Data collected included SF-12, WOMAC, and Oxford knee scores, and knee range of motion measurements. 37 of 40 patients enrolled completed the study. 22 patients were randomized to receive a standard posterior stabilized fixed bearing Genesis II knee replacement and 22 were randomized to receive a Hi-Flex posterior stabilized fixed bearing knee replacement. ROM, quality of life, and clinical scores at 12 months will be presented


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 130 - 130
1 Mar 2010
Kim J Choi C Park T Park Y Park K
Full Access

The purpose of this study was to evaluate the effect of decreasing tibial slope on extention gap during posterior stabilized total knee arthroplasty. 110 posterior stabilized total knee arthroplasties were studied for 2 groups;. having flexion contractures(n=35),. having no flexion contracture(n=75). In each group, we measured the decrease of tibial slope and frequency of additional distal femoral resecions that were done due to insufficient extension gap in comparison with flexion gap during posterior stabilized total knee arthroplasty. We also compared frequencies of additional distal femoral resections between 2 parts having more and less slope decrease in each groups. In each group, tibial slope decrease were 8.7 degrees, 7.4 degrees(p=0.145) and frequencies of additional resection were 51.4%, 24%(p=0.005) in average. In 2 parts having more and less slope decrease in each group, frequencies of additional resection were 44.4% vs 58.8%(p=0.505), 13.2% vs 35.1%(p=0.032). Results suggested that more decrease of tibial slope reduced frequency of additional distal femoral resection during posterior stabilized total knee arthroplasty in group having no flexion contracture. Decreasing tibial slope can be considered as a factor influencing on extension gap during posterior stabilized total knee arthroplasty. The estimation of predictable tibia slope decrease through preoperative radiologic findings can be beneficial in performing succeful posterior stabilized total knee arthroplasty


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 60 - 60
1 Feb 2021
Lustig S Batailler C Servien E Foissey C
Full Access

Introduction. Increasingly young and active patients are concerned about revision arthroplasty forcing the manufacturers to think about revision prostheses that fit to this population while meeting the indications and fitting with bone losses and ligament deficiencies. One of those industrials claims that its system allows the surgeon to rise the constraint from a posterior stabilized (PS) prostheses to a semi-constraint total stabilized (TS) prostheses without modifying the gait pattern thanks to a similar single radius design. The aim of the study was to compare gait parameters in patients receiving either PS or TS knee prostheses. Methods. Nineteen patients in each groups were prospectively collected for this study and compared between each other. All subjects were assessed with a 3D knee kinematics analysis, performed with an optoelectronic knee assessment device (KneeKG®). Were measured for each knees range of motion (ROM) in flexion–extension, abduction–adduction, internal–external rotation and anterior–posterior displacement. Results. There were no significant kinematic differences between PS and TS groups. The ROM in flexion-extension was 44° in PS group vs 46° in TS group, the ROM in internal-external rotation was 5.5° in PS group vs 4°in TS group. Peak varus angle during loading was equal (2.5°) and higher in PS group during swing phases (5.5° vs 3.7°) without any significancy. There appeared to be less antero-posterior translation in the TS group (maximum posterior displacement of −1 mm vs −5 mm) linked to the larger central post-cam without any significancy. Conclusion. TS designed have comparable gait parameters than PS prostheses. Its use won't prejudice the patient concerning the walking pattern


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 47 - 47
1 Apr 2019
Luo Z Zhou Z Pei F
Full Access

Object. Although single-radius designs have theoretical advantages in some aspects, there has been a paucity of evaluation studies. The purpose of this study was to compare 10-year clinical, radiological, survivorship outcomes of single radius and multi radius posterior stabilized prosthesis in total knee arthroplasty(TKA) with Rheumatoid Arthritis (RA). Method. In this retrospective observational study, we reviewed 240 patients (240 knees) with RA who underwent TKA between Oct 2005 and Dec 2007: SR group (120 patients, 120 knees, Stryker Scorpio NRG) and MR group (120 patients, 120 knees, Depuy sigma RP). A 1 : 1 matched case control study was conducted in two groups which were similar in terms of age, gender, BMI, ASA classification and operation team. Mean follow-up periods were 10.73±1.13 (range: 8–13) years and 10.82±1.09 (range: 7–13) years. Results. In SR group, the mean HSS score improved significantly from 38.63±8.76 to 87.67±6.62, the mean VAS score decreased significantly from 7.37±0.24 to 0.45±0.12. the mean range of motion improved significantly from 105.52°±7.78°to 124.32°±8.12° (p<0.001). In MR group, the mean HSS score improved significantly from 38.75±8.34 to 89.29±5.21, the mean VAS score decreased significantly from 7.62±0.26 to 0.33±0.10. the mean range of motion improved significantly from 104.18°±7.62° to 122.52°±8.03°(p<0.001). (See Figure 1) Clinical and functional improvements had no significant differences between the two groups. 6 complications were noted in SR group, including 2 cases of prosthetic loosening, 1 case of periprosthetic osteolysis, 3 cases of periprosthetic bright lines.6 complications were noted in MR group, including 2 cases of prosthetic loosening and 4 cases of periprosthetic bright lines. No case of infection was observed in two groups. Survivorship using Kaplan-Meier survival analysis was 97.5% (95% confidence interval [CI]: 96.8–98.3%) for the SR at 10 years and 98.3% (95% CI: 97.3–99.5%) for the MR group at 10 years, with no significant difference (p=0.755). (See Figure 2). Conclusion. This study suggested that both single-radius and multi-radius posterior stabilized prostheses can lead to satisfactory outcomes for clinical function, radiological evaluation and survivorship among RA patients undergoing TKA, and no significantly clinical differences was shown in two types of prostheses


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 83 - 83
1 Mar 2021
McAleese T Quinn M Graves S Clark G
Full Access

Abstract. Objectives. Patella resurfacing in primary total knee arthroplasty (TKA) remains a contentious issue. Australian rates of patellar resurfacing are 66.6%, significantly higher compared to UK rates of 8–15% and Swedish rates of 2%. Resurfacing has gained popularity in Australia since registry data has shown decreased revision rates with no increase in patellar component related complications. We present for discussion an analysis of 113,694 total knee arthroplasties using commonly implanted prostheses in the UK. Methods. We included all TKA's since the Australian register's conception on 01/09/1999 for a primary diagnosis of osteoarthritis involving the use of either the Triathlon or Duracon implant with and without patellar components. The primary outcome of the study was time to revision for Triathlon's resurfaced and non-resurfaced prosthesis compared to the Duracon's equivalent data. We also analysed the reasons for revision between the 4 groups, type of revision and complication rates. We then compared minimally stabilised and posterior stabilised prostheses. Results. The cumulative revision rate for Triathlon prostheses with resurfacing after 12 years was 3.2% (95% CI, 2.9% to 3.6%) compared to 5.6% (95% CI, 5.0% to 6.2%) without resurfacing. Duracon's equivalent data was 6.3% with resurfacing and 5.9% without resurfacing. Triathlon prosthesis with resurfacing have much lower rates of revision due to loosening, patellofemoral pain, patellar erosion compared to unresurfaced Triathlon prostheses. Conclusion. Triathlon with re-surfacing has lower revision rates regardless of age or BMI. Previous concerns regarding patellofemoral loosening, tibial wear, maltracking relate to Duracon only, indicating the importance of implant specific studies. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 56 - 56
1 Feb 2021
Catani F Illuminati A Ensini A Zambianchi F Bazzan G
Full Access

Introduction. Robotics have been applied to total knee arthroplasty (TKA) to improve surgical precision in component placement and joint function restoration. The purpose of this study was to evaluate prosthetic component alignment in robotic arm-assisted (RA)-TKA performed with functional alignment and intraoperative fine-tuning, aiming for symmetric medial and lateral gaps in flexion/extension. It was hypothesized that functionally aligned RA-TKA the femoral and tibial cuts would be performed in line with the preoperative joint line orientation. Methods. Between September 2018 and January 2020, 81 RA cruciate retaining (CR) and posterior stabilized (PS) TKAs were performed at a single center. Preoperative radiographs were obtained, and measures were performed according to Paley's. Preoperatively, cuts were planned based on radiographic epiphyseal anatomies and respecting ±3° boundaries from neutral coronal alignment. Intraoperatively, the tibial and femoral cuts were modified based on the individual soft tissue-guided fine-tuning, aiming for symmetric medial and lateral gaps in flexion/extension. Robotic data were recorded. Results. A total of 56 RA-TKAs performed on varus knees were taken into account. On average, the tibial component was placed at 1.9° varus (SD 0.7) and 3.3° (SD 1.0) in the coronal and sagittal planes, respectively. The average femoral component alignment, based on the soft tissue tensioning with spoons, resulted as follows: 0.7° varus (SD 1.7) in the coronal plane and 1.8° (SD 2.1) of external rotation relative to surgical transepicondylar axis in the transverse plane. A statistically significant linear direct relationship was demonstrated between radiographic epiphyseal femoral and tibial coronal alignment and femoral (r=0.3, p<0.05) and tibial (r=0.3, p<0.01) coronal cuts, resepctively. Conclusion. Functionally aligned RA-TKA performed in varus knees, aiming for ligaments’ preservation and balanced flexion/extension gaps, provided joint line respecting femoral and tibial cuts on the coronal plane


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_1 | Pages 80 - 80
1 Feb 2015
Berend K
Full Access

The goals of total knee arthroplasty (TKA) are to relieve pain, restore function, and provide a stable joint. In regard to types of implants, the workhorses are posterior cruciate retaining (CR), posterior stabilised (PS), and posterior stabilised constrained (PSC) designs. However, the continuum of constraint now ranges from standard cruciate retaining (CR-S) to CR lipped (CR-L), to anterior stabilised (CR-AS), to posterior stabilised, to a PS “plus” that fits with a PS femoral component but provides a small degree of varus-valgus constraint, to a PSC or constrained condylar type of device, to a rotating hinge. As the degree of deformity, bone loss, contracture, ligamentous instability and osteopenia increases, so does the demand for prosthetic constraint. When deformity is minimal and the posterior cruciate ligament (PCL) is intact and functional, a CR-S device is appropriate. For moderate deformity with deficiency or compromise of the PCL, a CR-AS or posterior stabilised device is warranted. In severe cases, with attenuation or absence of either of the collateral ligaments, a constrained condylar device, with options of stems, wedges and augments, is advisable. In salvage situations, when both collaterals are compromised, a rotating hinge should be utilised. Prerequisites for use of a CR-S device are an intact PCL, balanced medial and lateral collateral ligaments, and equal flexion and extension gaps. With a CR-L bearing, a slight posterior lip is incorporated into the sagittal profile of the component to provide a small amount of extra stability in the articulation. It is important for the surgeon to be aware of the design features of the implant system he or she is using. For example, in a system where the CR-S bearing has 3 degrees of posterior slope and the CR-L bearing has no slope, the thickness of a CR-L bearing posteriorly is approximately 2mm greater than the CR-S. A CR-L bearing is indicated for to provide stability where the flexion gap is just slightly looser than the extension gap and the PCL is intact. If the patient's knee is somewhat lax in flexion and stable in extension, a CR-L bearing may help to stabilise both the flexion and extension gaps yet still allow the knee to obtain full extension, whereas if a CR-S bearing in the next thicker size is used to stabilise the flexion gap, a flexion contracture may result. CR-AS bearings are indicated when the flexion and extension gaps are balanced, but the PCL is deficient, and the surgeon does not want to change to a PS design, which requires additional bony resection of intercondylar notch. The PCL is one of the strongest ligaments in the knee, and affords inherent stability to the TKA. In flexion, the PCL not only affords AP stability, but also imparts flexion gap stability, acting as a lateral stabiliser of the medial compartment and a medial stabiliser of the lateral compartment. The PCL has a crucial role with respect to femoral rollback, which imparts added efficiency to the extensor mechanism. PCL retention is a more biologically preserving operative intervention than PS-TKA


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 89 - 89
1 Dec 2020
Lentine B Tarka M Schottel P Nelms N Russell S Blankstein M
Full Access

Introduction. Femoral periprosthetic fractures above TKA are commonly treated with retrograde intramedullary nailing (IMN). This study determined if TKA design and liner type affect the minimum knee flexion required for retrograde nailing through a TKA. Methods. Twelve cadaveric specimens were prepared for six single radius (SR) TKAs and six asymmetric medial pivot (MP) TKAs. Trials with 9mm polyethylene liners were tested with cruciate retaining (CR), cruciate substituting (CS) and posterior stabilizing (PS) types. The knee was extended to identify the minimum knee flexion required to allow safe passage of the opening reamer while maintaining an optimal fluoroscopic starting point for retrograde nailing. Furthermore, the angle of axis deviation between the reamer and the femoral shaft was calculated from fluoroscopic images. Results. In all specimens, the reamer entry point was posterior to Blumensaat's line. In the SR TKA, the average flexion required was 70, 71 and 82 degrees for CR, CS and PS respectively. The required flexion in PS was significantly greater than the other designs (p=0.03). In the MP TKA, the average flexion required was 74, 84 and 123 degrees for CR, CS and PS respectively. The required flexion was significantly greater in CS and PS designs (p<0.0001). Femoral component size did not affect the minimum flexion required. Furthermore, the entry reamer required 9.2 (SR) and 12.5 (MP) degrees of posterior axis deviation from the femur. Conclusions. Our study illustrates four novel factors to consider when performing retrograde nailing through TKA. First, significant knee flexion is required to obtain an ideal radiographic starting point when retaining the liner. Second, PS implants require more flexion with both TKA designs. Third, femoral component size does not affect the flexion required. Fourth, there is a consistent posterior axis deviation of the entry reamer from the femoral shaft, explaining the commonly created extension deformity


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_29 | Pages 20 - 20
1 Aug 2013
van Graan W van der Merwe W
Full Access

Background:. We studied the effect of posterior condylar offset on maximum knee flexion after a posterior stabilised total knee arthroplasty. We also looked at gender difference and the post-operative change in posterior condylar offset. Methods:. Eighty consecutive computer navigated posterior stabilised total knee replacements were prospectively assessed intra-operatively for maximum knee flexion. The flexion angle was measured and recorded with an imageless computer navigation system (Brainlab) before and after implantation of the prosthesis. This was correlated with a radiological review of the posterior condylar offset pre- and post-operatively, as defined by posterior condylar offset ratio (PCOR) originally described by Soda (2007) and modified by the Bristol Knee Group (2010). Results:. No relationship could be found between change in posterior femoral offset ratio and the change in knee flexion before and after implantation of the prosthesis (p = 0.46.)This was especially true for female subjects (p = 0.87.)For male patients there was a trend towards an inverse relationship demonstrating decreasing flexion with an increase in PCOR (p = 0.16.) PCOR increased in 91 % of cases and overall increased from an average of 0.44 pre-operatively to 0.49 post-operatively. The increase in PCOR was smaller where a large pre-operative PCOR was present (p = 0.0006.)Pre-operative flexion correlated significantly with postoperative flexion (p = 0.00.)There was no difference in PCOR between male and female patients. Conclusion:. Knee flexion is not influenced by a change in posterior condylar offset in posterior stabilised knees. The increase in posterior condylar offset with a posterior stabilised TKA could by explained a larger increase in the flexion gap than in the extension gap, when sectioning the posterior cruciate ligament. The PCOR increases in cases with smaller pre-operative posterior condylar offset. Pre-operative flexion is a significant predictor of postoperative flexion


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_8 | Pages 84 - 84
1 May 2014
Berend K
Full Access

The goals of total knee arthroplasty (TKA) are to relieve pain, restore function, and provide a stable joint. In regard to types of implants, the workhorses are posterior cruciate retaining (CR), posterior stabilised (PS), and posterior stabilised constrained (PSC) designs. However, the continuum of constraint now ranges from standard cruciate retaining (CR-S) to CR lipped (CR-L), to anterior stabilised (CR-AS), to posterior stabilised, to a PS “plus” that fits with a PS femoral component but provides a small degree of varus-valgus constraint, to a PSC or constrained condylar type of device, to a rotating hinge. As the degree of deformity, bone loss, contracture, ligamentous instability and osteopenia increases, so does the demand for prosthetic constraint. When deformity is minimal and the posterior cruciate ligament (PCL) is intact and functional, a CR-S device is appropriate. For moderate deformity with deficiency or compromise of the PCL, a CR-AS or posterior stabilised device is warranted. In severe cases, with attenuation or absence of either of the collateral ligaments, a constrained condylar device, with options of stems, wedges and augments, is advisable. In salvage situations, when both collaterals are compromised, a rotating hinge should be utilised. Prerequisites for use of a CR-S device are an intact PCL, balanced medial and lateral collateral ligaments, and equal flexion and extension gaps. With a CR-L bearing, a slight posterior lip is incorporated into the sagittal profile of the component to provide a small amount of extra stability in the articulation. It is important for the surgeon to be aware of the design features of the implant system he or she is using. For example, in a system where the CR-S bearing has 3 degrees of posterior slope and the CR-L bearing has no slope, the thickness of a CR-L bearing posteriorly is approximately 2mm greater than the CR-S. A CR-L bearing is indicated for to provide stability where the flexion gap is just slightly looser than the extension gap and the PCL is intact. If the patient's knee is somewhat lax in flexion and stable in extension, a CR-L bearing may help to stabilise both the flexion and extension gaps yet still allow the knee to obtain full extension, whereas if a CR-S bearing in the next thicker size is used to stabilise the flexion gap, a flexion contracture may result. CR-AS bearings are required less frequently. They are indicated when the flexion and extension gaps are balanced, but the PCL is deficient, and the surgeon does not want to change to a PS design, which requires additional bony resection of intercondylar notch. The PCL is one of the strongest ligaments in the knee, and affords inherent stability to the TKA. In flexion, the PCL not only affords AP stability, but also imparts flexion gap stability, acting as a lateral stabiliser of the medial compartment and a medial stabiliser of the lateral compartment. The PCL has a crucial role with respect to femoral rollback, which imparts added efficiency to the extensor mechanism. PCL retention is a more biologically preserving operative intervention than PS-TKA


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 94 - 94
1 Sep 2012
Kosashvili Y Serendono JS Ben-Lulu O Safir O Gross AE Backstein D
Full Access

Purpose. Two-stage re-implantation after infection of Total Knee Arthroplasty (TKA), remains the gold standard to which other forms of treatment should be compared. The primary purpose of this study was to determine the rates of failure and functional outcome of two stage revision TKA for treatment of infection comparing cemented posterior stabilized compared to constrained condylar implants. Method. The study group included 25 consecutive patients who had two stage revision TKA to treat infection with an average follow up of 3.25 1.5 years (range 2–6). In all patients the diagnosis of infection was made using standard serum parameters as well as aspiration for joint fluid analysis. Eight patients had posterior stabilized TKAs and 17 patients with had constrained condylar TKAs. Clinical evaluation included the Knee Society Knee Scores (KSKS) at each follow-up visit as well as a detailed record of any difficulties or complications. Results. No patient (8/8) in the LPS posterior stabilized group and 16 of 17 (94.1%) patients in the LCCK constrained condylar group, had any complaint indicative of instability. Two patients (8%) had re-infection (1 in each group). There was no significant difference between the knee scores (p=0.64) and function scores (p=0.38) of the LPS posterior stabilized and LCCK constrained condylar groups at latest follow up. Conclusion. Our findings suggest that the strategy of using the least constrained implants that provide adequate stability as judged intra-operatively is appropriate also in 2 stage revision TKAs for infection


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 128 - 128
1 Dec 2013
Moon Y Lim H Ko KR Lee KH So S Seo J
Full Access

Background:. The safety implications of achieving high flexion after TKA and the use of high flexion prostheses remain issues of concern. It is possible that different designs have different clinical and radiological results and complications, such as, early aseptic loosening. However, little information is available on the clinical results of TKAs performed using single-radius, high-flex posterior stabilized design. Accordingly, this study was undertaken to document results of single-radius, high-flex posterior stabilized TKAs with minimum 7-year follow-up. Methods:. From April 2003 to February 2006, 308 patients (455 knees) underwent TKA using single-radius, high-flex posterior stabilized design and among those patients, 251 patients (388 knees) included in this study who were able to be followed up for a minimum 7 year. Clinical results were evaluated using Knee Society Knee scores (KSKS) and Knee Society Function scores (KSFS) at last follow-up. The passive knee flexion was measured using a goniometer before and after surgery. The survival rate of the implants and implant-specific complications such as osteolysis or loosening were investigated. The osteolysis or loosening around the components was recorded according to the Knee Society Radiological scoring System. Results:. Mean Knee Society Knee score improved from 48.2 preoperatively to 96.8 postoperatively and mean Function score improved from 49.7 preoperatively to 74.2 postoperatively, respectively. The average range of motion (ROM) improved from 112.7° preoperatively to 131.5° postoperatively. Postoperative mechanical axis deviation (MAD) was within −3° to 3°, in 316 knees (81.4%). Non-progressive osteolysis was observed at zone 4 of the femoral component in eight knees (2.06%), at zone 3 of the tibial component in one knee (0.26%), at zone 2 of the tibial component in two knees (0.52%), and at zone 1 of the tibial component in thirteen knees (3.35%) in anteroposterior view. Two cases were revised due to infection and recurrent hemarthrosis. However, no complications, like early aseptic loosening, that have been associated with high flexion designs were observed. Conclusions:. Clinical results for TKAs conducted using a single-radius, high-flex posterior stabilized design with a minimum 7-year follow-up were favorable. Furthermore, no high flexion implant-specific complications such as early aseptic loosening were encountered


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 368 - 368
1 Mar 2004
Forster M
Full Access

Aims: In this study, data from previously published survival analysis life tables of primary total condylar type TKRs has been combined to enable comparison of different design features. In particular, does posterior stabilisation or metal backing of the tibial component improve the longevity of primary cemented þxed bearing condylar type TKRs?Methods: To be included, the article had to give 5 or more years results of a primary cemented þxed bearing condylar type TKRs including a survival analysis life table. Series performed on a selected patient group (for example young age, elderly or rheumatoid arthritis) were excluded to reduce possible bias. When 2 series of the same implant from the same institution were available, the most recent article with the longest follow up was used. Results: Survival analysis data from 16 papers (5950 knees) was combined to compare design features. There was no difference in survival between posterior stabilised implants and those that were not or between metal-backed and all-polyethylene tibial components. Those all-polyethylene tibial components that were not stabilised had signiþcantly better survival than metal-backed, non stabilised tibial components and posterior stabilised, metalbacked components (p< 0.05) but not posterior stabilised, all-polyethylene components. Conclusions: Using the currently available literature, posterior stabilisation or metal backing of the tibial component does not improve the longevity of primary cemented þxed bearing condylar type TKRs


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_22 | Pages 85 - 85
1 May 2013
Berend K
Full Access

The goals of total knee arthroplasty (TKA) are to relieve pain, restore function, and provide a stable joint. In regard to types of implants, the workhorses are posterior cruciate retaining (CR), posterior stabilised (PS), and posterior stabilised constrained (PSC) designs. However, the continuum of constraint now ranges from standard cruciate retaining (CR-S) to CR lipped (CR-L), to anterior stabilised (CR-AS), to posterior stabilised, to a PS “plus” that fits with a PS femoral component but provides a small degree of varus-valgus constraint, to a PSC or constrained condylar type of device, to a rotating hinge. As the degree of deformity, bone loss, contracture, ligamentous instability and osteopenia increases, so does the demand for prosthetic constraint. When deformity is minimal and the posterior cruciate ligament (PCL) is intact and functional, a CR-S device is appropriate. For moderate deformity with deficiency or compromise of the PCL, a CR-AS or posterior stabilised device is warranted. In severe cases, with attenuation or absence of either of the collateral ligaments, a constrained condylar device, with options of stems, wedges and augments, is advisable. In salvage situations, when both collaterals are compromised, a rotating hinge should be utilised. Prerequisites for use of a CR-S device are an intact PCL, balanced medial and lateral collateral ligaments, and equal flexion and extension gaps. With a CR-L bearing, a slight posterior lip is incorporated into the sagittal profile of the component to provide a small amount of extra stability in the articulation. It is important for the surgeon to be aware of the design features of the implant system he or she is using. For example, in a system where the CR-S bearing has 3° of posterior slope and the CR-L bearing has no slope, the thickness of a CR-L bearing posteriorly is approximately 2 mm greater than the CR-S. A CR-L bearing is indicated for to provide stability where the flexion gap is just slightly looser than the extension gap and the PCL is intact. If the patient's knee is somewhat lax in flexion and stable in extension, a CR-L bearing may help to stabilize both the flexion and extension gaps yet still allow the knee to obtain full extension, whereas if a CR-S bearing in the next thicker size is used to stabilise the flexion gap, a flexion contracture may result. CR-AS bearings are required less frequently. They are indicated when the flexion and extension gaps are balanced, but the PCL is deficient, and the surgeon does not want to change to a PS design, which requires additional bony resection of intercondylar notch. The PCL is one of the strongest ligaments in the knee, and affords inherent stability to the TKA. In flexion, the PCL not only affords AP stability, but also imparts flexion gap stability, acting as a lateral stabilizer of the medial compartment and a medial stabiliser of the lateral compartment. The PCL has a crucial role with respect to femoral rollback, which imparts added efficiency to the extensor mechanism. PCL retention is a more biologically preserving operative intervention than PS-TKA


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 217 - 217
1 Jul 2008
Anjarwalla NK Morcom RK Fraser RD
Full Access

Objectives: The purpose of this study was to assess the effect of different types of posterior stabilisation on the fusion rate of anterior lumbar interbody fusion (ALIF). Thin section CT scanning has shown a higher rate of pseudarthrosis with ALIF than previously reported with standard radiological modalities. Cadaveric studies have demonstrated that posterior stabilisation would increase stiffness of the motion segment and is likely to enhance the rate of fusion with ALIF. The results of thin section CT scanning of ALIF, with and without posterior stabilisation, has not been reported previously. Methods: Patients with discogenic back pain confirmed by discography underwent ALIF surgery as a stand alone procedure or with posterior stabilisation – using trans-laminar screws, unilateral pedicle screws or bilateral pedicle screws. Patients were followed up prospectively and thin section CT scanning was used to assess inter-body fusion. Results: The fusion rate for stand alone ALIF was 51%, for patients with supplementary stabilisation with trans-laminar screws 58%, with unilateral pedicle screws 89% and with bilateral pedicle screws 88%. When ALIF was combined with pedicle screw stabilisation a significant difference in the fusion rate was found (p< 0.01). Conclusion: The addition of pedicle screw fixation at the time of ALIF produces a significant increase in the rate of interbody fusion


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 5 - 5
1 Oct 2020
Zamora T Garbuz DS Greidanus NV Masri BA
Full Access

Introduction. Our objective is to describe early and midterm results with the use of a new knee prosthesis as an articulating spacer in planned two-stage management for infected total knee arthroplasty. As a second objective, we compared outcomes between the group with a retained first stage and those with a completed 2-stage revision. Methods. Forty-seven patients (48 knees) from January 2012 and November 2017 underwent a 2-stage exchange with an articulating spacer with new implants was used for a chronic knee periprosthetic joint infection with a mean follow-up of 3.7 years (2–6.5 years). The most frequently identified infecting organism was MSSA (31%), MRSA (21%) or MRSE (20%). At the first stage, a new PS femoral component and a new all-polyethylene posterior stabilized (PS) tibial component or a standard PS tibial liner were cemented with antibiotic-cement, typically 3.6 gm tobramycin and vancomycin 1.5 gm. IV antibiotics for six weeks were administered. The planned reimplantation was at 3 months, but ninetteen spacers (14 all poly tibias and 5 tibial liner) were retained for over 12 months. Postoperative assessment included knee range of motion (ROM), quality of life (QOL) scores (SF-12, WOMAC, KOOS, Oxford, and UCLA scores), and a satisfaction scale from 0–100%. Results. Of the 48 knees, 8 failed due to lack of infection control, and 2 died within the first year for medical reasons (4%), giving a failure rate of 17% (8/46). One of these knees was not revised due to poor medical status. Of the remaining 7, 2 had a repeat 2-stage exchange, one a single stage revision and 4 irrigation and debridement with retained implants. All 7 had a successful outcome with infection control after this, leaving a permanent failure rate of 2% (1/46). Five of the 19 knees with initially retained implants were revised to a second stage after 12 months for continued pain or instability (1/14 all poly tibia and 4/5 PS liner). There were no significant differences in final range of motion or QOL scores between patients with a retained first stage procedure and those who underwent a second stage operation. Also, there was no statistically significant difference in the initial failure rate due to infection between patients with a complete 2-stage revision and those with a retained first stage (19% (6/31) vs. 14% (2/14), respectively; p=0.613). Conclusions. When an all poly tibial implant is used a spacer in two-stage exchange arthroplasty, it may be retained for over 12 months, with no difference in infection control, range of motion, and quality of life assessment to patients with complete 2-stage revision surgery. With this technique, the second stage may be delayed in patients who are doing well, and may never need to be revised, hence we propose the new term “one-and-a-half stage exchange”


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_17 | Pages 70 - 70
1 Nov 2016
Tria A
Full Access

Bicruciate ligament retaining total knee arthroplasty preserves all of the ligaments of the knee while still addressing the ligament balance and the flexion-extension gaps. The concept of cruciate ligament preservation is not new and both Townley and Cartier designed prostheses in the late 1980s that did preserve all of the ligaments. Their results were quite acceptable for that time in knee replacement surgery but the posterior stabilised and cruciate retaining designs controlled most of the market. The surgical technique for cruciate ligament preservation was more difficult, and without clear clinical benefit, most surgeons gravitated towards the cruciate retaining and posterior stabilised designs. In the late 1990s, evaluation of the total knee arthroplasty began to assess knee kinematics in addition to pain and functional outcomes. At the same time, studies on the unicondylar knee arthroplasty demonstrated impressive scores in motion and patient satisfaction with preservation of all of the ligamentous structures of the knee. Over the past two years, new designs that preserve all of the ligaments of the knee have returned to the market. The instruments have been improved and the prostheses have been changed to respect the kinematics of the knee. Fifteen to twenty percent of all total knee replacement patients are not completely satisfied with the surgery and the authors believe that complete ligament preservation may address this complaint


Purpose. The purpose of this study was to compare intercompartmental loads and the proportion of knees with unbalanced loads after tensiometer-assisted balancing (TAB) between cruciate retaining (CR) and posterior stabilized (PS) total knee arthroplasty (TKA). Materials and Methods. Forty-five CR and 45 PS TKAs using a single prosthesis were prospectively evaluated. The intercompartmental loads in 10°, 45°, and 90° of knee flexion after TAB were evaluated; the proportions of load imbalance (medial load – lateral load >15 lbs) in each flexion angle after TAB were investigated. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of TAB were calculated, with the sensor-balanced loads considered the reference standard. Results. The average loads of the medial compartment in CR TKA were greater than the adequate load (55 lbs) in every knee flexion angle; those of PS TKA were <55 lbs. The proportions of the load imbalance were >50% in every knee flexion angle in both CR and PS TKA (CR >64.4% and PS >57.8%), and there was no difference between the groups (p > 0.515). The sensitivity, specificity, PPV, and NPV of TAB were 91.7%, 66.7%, 57.9% and 94.1%, respectively, in CR, and 100%, 62.5%, 40 %, and 100%, respectively, in PS TKA. Conclusions. The appropriate load balancing from the tensiometer seemed to be difficult in both CR and PS TKA. The intraoperative load sensor had a role in accurate load balancing to overcome the poor PPV of the tensiometer in both types of TKA


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 112 - 112
1 Jun 2018
Vince K
Full Access

The most recent Australian registry has a database of 547,407 knee arthroplasties, having added over 52,000 in 2016. Total knee arthroplasties (TKA) comprise 83.8%, revisions (RevTKA) 8.1% and “partials of all types” 8.1%. Since 2003, the percent of TKA has increased from 76.7%, RevTKA has stayed stable and partial replacements have declined from 14.5%. In the last year, however, TKA declined slightly. There is a slightly higher percentage of women (56.1%) undergoing TKA and this has remained very stable since 2003. Revision rates are slightly higher for men. Percentages of the youngest (<55) and oldest (>85) are small and stable. The 75–84 year olds have declined as 55–74 year olds have increased. This represents a gradual shift to earlier TKA surgery. More patella are resurfaced and this is a gradual trend with a cross over in 2010 when half were resurfaced. Computer navigation is progressively more popular and now accounts for almost 30% of cases. Cement fixation is also increasing and accounts for about 65% of cases. Crosslinked polyethylene is gradually replacing non crosslinked and in 2014 was used in 50% of cases. Revisions are performed most commonly for loosening and infection. Revision rates correlate directly with age. Loosening is the most common indication for revision in both genders, but males have a distinctly higher revision rate due to infection. Revision rates are slightly higher in all forms of mobile bearing than fixed bearing. Minimally constrained (cruciate retaining) devices are used in the majority of TKAs. Posterior stabilised implants are in slight decline, having peaked in about 2008–2010. Minimally constrained implants are in slight decline as medial pivot/medial congruent devices have been used more frequently. Revision rates are similar amongst all three implant types: PS implants are revised at a slightly higher rate. When an early Medial Pivot (MP) implant is excluded the newer version has better results. The reasons for revision are similar amongst all 3 groups with slightly higher loosening rates for PS designs. (Could this represent backside wear with older locking mechanisms, surface finish and non crosslinked poly?) The MP designs had slightly higher revision rates for “pain”, which is not recognised as a reasonable indication for revision. Revision rates are steadily higher for TKAs without patella resurfacing over 16 years, but the questions as to whether: i. the surgeries were secondary resurfacings or full revisions or ii. if secondary resurfacings eliminated pain are unknown. The combinations at greatest risk of revision were a posterior stabilised or medial pivot arthroplasty without patellar resurfacing. Cementless fixation leads to a higher revision rate. If age and computer navigation are evaluated in terms of revision rates, young patients with and without computer navigated arthroplasties failed at the highest rates, distinct from patients >65. However, if failure rates due only to loosening are evaluated, then computer navigation leads to a lower revision rate in the <65 group. This has been interpreted as the protective effect of better component position that only shows up in patients who use the arthroplasty more aggressively. Patient specific instrumentation (PSI) or Individual Designed Instrumentation (IDI) were revised at marginally higher rates than conventional instrumentation. Crosslinked polyethylene appears to be superior at 12 years (CRR= 4%) versus non crosslinked polyethylene (CRR>7%). This is the result of fewer failures due to loosening with crosslinked poly. The superiority of crosslinked poly was greater in the younger, more active patient


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 463 - 463
1 Apr 2004
Thorpe P Williams R Licina P
Full Access

Introduction: Anterior lumbar interbody fusion (ALIF) with posterior stabilisation is an established treatment for degenerative disc disease. 1. Some previous reports have advocated a goal of 360 degree fusion, and condemned posterior stabilisation as it does not achieve fusion of the posterior facet joints. 2. Others have claimed that the concept of a ‘locked pseudarthrosis’ gives satisfactory clinical results. 3. There is also a contention that private or self-funding patients achieve better results after spinal fusion compared to those treated under compensation or Dept. Veterans Affairs (DVA) schemes. Methods: Twenty patients who had undergone an ALIF with posterior stabilisation were retrospectively reviewed. All had a follow-up greater than 12 months. 13 patients were private and 7 non-private. The groups were aged and sex matched. Radiological assessment of fusion was made with reconstruction CT scans. Oswestry Disability Index (ODI) scores were recorded preoperatively, 6 months and 12 months post operation. Results: Patients with locked pseudarthrosis showed no significant difference in outcome compared to those with radiological fusion. Both groups showed signifi cant improvement in ODI scores after ALIF (mean preop. = 52 – range 16-74; mean postop. = 18 – range 0-52; p< 0.01). There was a significantly greater improvement (p< 0.02) in ODI scores in private patients (mean reduction = 41 points) compared to worker’s compensation or DVA patients (mean reduction = 22 points). Discussion: The results indicate that ALIF with posterior stabilisation can achieve good clinical results even with a ‘locked pseudarthrosis’. While there is no significant difference between outcomes in different health funding groups shown in the study, carefully patient select for this treatment is the key to success


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 524 - 524
1 Sep 2012
Prasad K Hussain A
Full Access

We hypothesised that an independent Notch Trial is essential on the same lines as other Component Trials-Femoral, Tibial and Patellar - in posterior stabilised total knee arthroplasty. Therefore we evolved Notch Trial to visually ascertain the adequacy of intercondylar resection and eliminate the possibility of femoral intercondylar fractures. We undertook a retrospective study to evaluate Notch Trial by the frequency of the need to remove osteophytes or file uneven surfaces in intercondylar resection by using the detachable box part of the trial femoral component, assess occurrence of distal femoral intercondylar fractures and demonstrate Notch Trial in posterior stabilised total knee replacement. We studied 206 patients, 113 females and 93 males, who underwent consecutive primary posterior stabilised total knee replacements applying Notch Trial between 2000 and 2008 in a District General Hospital under our team. Outcome Measurements were 1) frequency of the need to remove osteophytes or file uneven surfaces in intercondylar resection and 2) occurrence of distal femoral intercondylar fractures intraoperatively or on postoperative radiographs. We had to remove the osteophytes and file the cut surfaces in 183 (88.88%) of patients after Notch Trial. We had no distal femoral intercondylar fractures intraoperatively or on postoperative radiographs. Notch Trial allows the surgeon to directly visualise and ascertain the adequacy and precise fit of femoral notch cut with cam part of femoral component to ensure a press fit femoral component in condylar posterior cruciate substituting total knee replacement. Notch Trial prior to Femoral Component Trial effectively pre-empts intraoperative distal femoral intercondylar fractures. We recommend that Notch Trial should become part of the protocol for cruciate substituting total knee replacement and implants of all companies should have the option of a detachable box component for Notch Trial


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 81 - 81
1 Apr 2012
Acharya S Garg A Chahal R Kalra K
Full Access

The study was conducted to review the outcome in cases of anterior expandable interbody cages inserted through a posterior only approach. Cases selected were the anterior cage insertion and posterior stabilization patients managed by posterior only approach. Study includes the patients of various pathologies requiring 3 column support. Twenty patients were included in study. Pathology in 9 patients was tuberculosis, trauma in 3, tumours in 3, metastasis in 3 and deformities in 2patients. Patients with or without neurological deficit were included. Cases were carefully assessed and patients with single level involvement were included as more then single level involvement required more extensive exposure and possible nerve root sacrifice. Detailed neurological status was recorded. The surgery was performed in prone position and after posterior stabilization by pedicle screws the extracavitatory approach was used to insert the expandable cage. In cases of suspicious pathologies the samples for histopathology and staining were collected. Morbidity, mortality blood loss, surgical time, complications, outcome of surgery were compared with historical controls of front and back surgery. The insertion of cages from posterior approach was feasible in all carefully planned cases. None of the patients had problem related to implant in form of cage displacement. All the patients had satisfactory outcome. Posterior stabilization of spine with expandable cage insertion from posterior approach saves the operating time, spares the additional surgical incision and blood loss without compromising the outcome. In carefully planned surgeries it gives excellent results irrespective of etiology


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 155 - 155
1 Jul 2014
Hutchinson R Choudry Q McLauchlan G
Full Access

Summary. The 80% porous structure of trabecular metal allows for bone ingrowth in more than 90% of the available surface. The Nexgen LPS Uncemented Knee using a trabecular metal tibial component has performed well at minimum of 5 years’ follow-up. Introduction. Total Knee Arthroplasty prostheses most frequently used in today's practice have cemented components. These have shown excellent clinical results. The fixation can however weaken with time, and cement debris within the articulation can lead to accelerated wear. Cementless implants are less commonly used, but some have also shown good long-term clinical results. The potential advantages of cementless implants are retention of bone stock, less chance of third-body wear due to the absence of cement, shorter operative time, and easier treatment of periprosthetic fractures. The posterior stabilised knee replacement has been said to increase tangential shear stresses on the tibial component and increases contact stresses on the cam and post mechanism hence the great debate of cruciate retaining or cruciate sacrificing implants. Objectives. We report the results of a prospective cohort of consecutive primary total knee arthroplasties using an uncemented posterior stabilised prosthesis using a trabecular metal (tantalum) tibial component at a minimum 5-year follow-up. Methods. Prospective 5 year follow-up of patients undergone an uncemented posterior stabilised total knee replacement using a trabecular metal tibial component (NexgenLPS). Clinical examination, Oxford knee score, Knee society score, SF12 and radiological evaluation undertaken at review. Results. 81 patients, 45 female, 36 male. Left 31, Right 50. Mean age 74.3 yrs range (51–90). SF12, mean: 31.8 range (25–37). Oxford Knee Score Pre-op Mean 20.1 range (9–36) Post op: Mean 32.1 range (9–48). Knee Society score. Pain Mean 91.8; range (60–100). Functional score mean 76.2; range (30–100). Mean Range of movement 110.5 degrees range (90–125). No evidence of loosening at 5 yrs. No deep infection. No Revisions. Conclusion. Although there are a variety of methods of achieving satisfactory initial fixation in cementless components, trabecular metal has an advantage owing to its cellular structure resembling bone. The 80% porous structure of trabecular metal allows for bone ingrowth in more than 90% of the available surface. The Nexgen LPS Uncemented Knee using a trabecular metal tibial component used in this series has shown no evidence of loosening at a minimum of 5 years’ follow-up and the prosthesis as a whole has performed very well clinically. Its early results are comparable to those prostheses most commonly used as reported by the arthroplasty registers. The longer term results from this prosthesis are awaited with interest


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 331 - 332
1 Nov 2002
Sengupta D Grevitt M Freeman B Mehdian S Mulholland R Webb J
Full Access

Objective: This study investigates whether the sequence of anterior and posterior procedure has any effect on the lordosis, disc height and stability in combined A-P fusion of the lumbar spine. Design: A biomechanical study on cadaver lumbar spine. Materials and Methods: Twelve motion segments (between L2–L5) from four cadaver lumbar spines were studied. Anterior and posterior stabilization were performed using a Syncage (Synthes, Switzerland) of appropriate sizes, and translaminar screws respectively. Load-deformation characteristics in flexion-extension, lateral bending, and torsion were tested in a material-testing machine (Dartec, Stourbridge, UK) with 7.5Nm cyclical load. Angular deformation of each motion segment was determined simultaneously, by 2-D optical reflex camera system (Pro-reflex, Qualysis, Sweden). Disc height, and angle of lordosis between the adjacent endplates were determined from lateral radiographs. These parameters were measured in the intact spine, after A-P fixation with front first, and after back procedure first. Results: Compared to the intact spine, the disc height was significantly increased (p< 0.05) when Syncages were introduced before posterior fixation, but not when posterior fixation was done first (p = 0.12). The angle of lordosis was increased significantly with posterior stabilization first, but only marginally, with anterior stabilization first. The stability of the motion segments increased significantly with combined A-P fusion, compared to either anterior or posterior fixation alone. With posterior stabilization first, the stability in all directions were greater but not statistically significant, compared to anterior stabilization first (p> 0.05). Conclusion: In combined A-P fusion of lumbar spine, the lordosis is better restored when posterior stabilization is done first, but disc height is better restored when the anterior stabilization is performed first. Stability of fixation is not significantly affected by altering the sequence


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 49 - 49
1 Jul 2020
Gascoyne T Parashin S Teeter M Bohm E Laende E Dunbar MJ Turgeon T
Full Access

The purpose of this study was to examine the influence of weight-bearing on the measurement of in vivo wear of total knee replacements using model-based RSA at 1 and 2 years following surgery. Model-based RSA radiographs were collected for 106 patients who underwent primary TKR at a single institution. Supine RSA radiographs were obtained post-operatively and at 6-, 12-, and 24-months. Standing (weight-bearing) RSA radiographs were obtained at 12-months (n=45) and 24-months (n=48). All patients received the same knee design with a fixed, conventional PE insert of either a cruciate retaining or posterior stabilized design. Ethics approval for this study was obtained. In order to assess in vivo wear, a highly accurate 3-dimensional virtual model of each in vivo TKA was developed. Coordinate data from RSA radiographs (mbRSA v3.41, RSACore) were applied to digital implant models to reconstruct each patient's replaced knee joint in a virtual environment (Geomagic Studio, 3D Systems). Wear was assessed volumetrically (digital model overlap) on medial and lateral condyles separately, across each follow-up. Annual rate of wear was calculated for each patient as the slope of the linear best fit between wear and time-point. The influence of weight-bearing was assessed as the difference in annual wear rate between standing and supine exams. Age, BMI, and Oxford-12 knee improvement were measured against wear rates to determine correlations. Weight bearing wear measurement was most consistent and prevalent in the medial condyle with 35% negative wear rates for the lateral condyle. For the medial condyle, standing exams revealed higher mean wear rates at 1 and 2 years, supine, 16.3 mm3/yr (SD: 27.8) and 11.2 mm3/yr (SD: 18.5) versus standing, 51.3 mm3/yr (SD: 55.9) and 32.7 mm3/yr (SD: 31.7). The addition of weight-bearing increased the measured volume of wear for 78% of patients at 1 year (Avg: 32.4 mm3/yr) and 71% of patients at 2 years (Avg: 48.9 mm3/yr). There were no significant (95% CI) correlations between patient demographics and wear rates. Volumetric, weight-bearing wear measurement of TKR using model-based RSA determined an average of 33 mm3/yr at 2 years post-surgery for a modern, non-cross-linked polyethylene bearing. This value is comparable to wear rates obtained from retrieved TKRs. Weight-bearing exams produced better wear data with fewer negative wear rates and reduced variance. Limitations of this study include: supine patient imaging performed at post-op, no knee flexion performed, unknown patient activity level, and inability to distinguish wear from plastic creep or deformation under load. Strengths of this study include: large sample size of a single TKR system, linear regression of wear measurements and no requirement for implanted RSA beads with this method. Based on these results, in vivo volumetric wear of total knee replacement polyethylene can be reliably measured using model-based RSA and weight-bearing examinations in the short- to mid–term. Further work is needed to validate the accuracy of the measurements in vivo


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 29 - 29
1 Feb 2017
Ishida K Shibanuma N Toda A Kodato K Inokuchi T Matsumoto T Takayama K Kuroda R Kurosaka M
Full Access

PURPOSE. Total knee arthroplasty (TKA) is a successful technique for treating painful osteoarthritic knees. However, the patients' satisfaction is not still comparable with total hip arthroplasty. Basically, the conditions with operated joints were anterior cruciate ligament (ACL) deficient knees, thus, the abnormal kinematics is one of the main reason for the patients' incomplete satisfaction. Bi-cruciate stabilized (BCS) TKA was established to reproduce both ACL and posterior cruciate ligament (PCL) function and expected to improve the abnormal kinematics. However, there were few reports to evaluate intraoperative kinematics in BCS TKA using navigation system. Hence, the aim in this study is to reveal the intraoperative kinematics in BCS TKA and compare the kinematics with conventional posterior stabilized (PS) TKA. Materials and Methods. Twenty five consecutive subjects (24 women, 1 men; average age, 77 years; age range, 58–85 years) with varus osteoarthritis undergoing navigated BCS TKA (Journey II, Smith&Nephew) were enrolled in this study. An image-free navigation system (Stryker 4.0 image-free computer navigation system; Stryker) was used for the operation. Registration was performed after minimum medial soft tissue release, ACL and PCL resection, and osteophyte removal. Then, kinematics including tibiofemoral rotational angles from maximum extension to maximum flexion were recorded. The measurements were performed again after implantation. We compared the kinematics with the kinematics of paired matched fifty subjects who underwent conventional posterior stabilized (PS) TKA (25 subjects with Triathlon, Stryker; 25 subjects with PERSONA, ZimmerBiomet) using navigation statistically. Results. Preoperative tibiofemoral rotational kinematics were almost the same between the three implants groups. Kinematics at post-implantation found that tibia was significantly internally rotated compared to the kinematics at registration in all three implants at maximum extension position (p<0.05), however the tibial rotational position with BCS TKA was significantly externally rotated at maximum extension position, compared to the other two implant position (p<0.05). The tibial rotational position with Triathlon PS TKA was externally rotated at 60 degrees of flexion compared to the other two implant position, however the results were not statistically significant. Discussion and Conclusion. Previous study found that PCL resection changed tibial rotational position and the amount of tibial internal rotation, affecting postoperative maximum flexion angles. This study found that BCS TKA can reduce the amount of rotational changes, compared to conventional PS TKA. Further studies are needed to investigate the kinematic changes in BCS TKA affect the postoperative clinical outcomes


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 26 - 26
1 May 2019
Padgett D
Full Access

First generation condylar knee replacements suffered from 2 prominent observations: Difficulty in stair climbing and Limited range of motion. Improved understanding of knee kinematics, the importance of femoral rollback, and enhanced stability in flexion led to 2 differing schools of thought: posterior cruciate ligament retention or posterior cruciate substitution. The advantages of posterior cruciate substitution include predictable CAM-post engagement leading to rollback, predictable ROM, stability during stair climbing, ease of knee balancing regardless of degree of angular deformity, and avoidance of issues such as PCL tightness / laxity at time of index procedure, as well as late ligament disruption leading to late instability. Evolution has shown that human appendages that no longer served a purpose, slowly shrivel up. As we have seen with the appendix, the coccyx, and the erector pili muscles, these vestigial organs no longer are necessary for daily function and are destined for obsolescence. I submit: the PCL in knee arthroplasty IS THE VESTIGIAL ORGAN: not the posterior stabilizing mechanism!


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_I | Pages - 43
1 Mar 2002
Piétu G Cappelli M Waast D Guilleux C
Full Access

Purpose: Retrograde nailing is emerging among methods proposed or stabilisation of femoral fractures above total knee arthroplasties (TKA). Material and methods. Between June 1994 and may 2000, 12 fractures above TKA were treated by retrograde nailing. These fractures occurred 43 months (4–51) after implantation of the TKA in three men and women aged 74 years (43–88). The fracture was situated just above the prosthetic trochlea in ten, and distant from the implant in two. The posterior cruciate ligament was preserved in six TKA and six were posterior stabilised prostheses. Indications for arthroplasty were degenerative joint disease in nine and rheumatoid polyarthritis in three. Four patients had proximal implants (one fixation and three prostheses). A percutaneous approach was used except for three cases in order protect the tibial component. Closed reduction was achieved, but required an open reduction for completion in two cases. the nail was advanced just to the trochlea in patients with a preserved posterior cruciate ligament and beyond the posterior stabilisation cage for the posterior stabilised implants. The knee was mobilised immediately after surgery and total weight-bearing was encouraged four to six weeks later. Results: There was one error in the proximal aiming, one metastatic infection from a leg ulcer at three months and one tibial loosening in a polyarthritic woman 66 months after arthroplasty, i.e. 51 months after the fracture. Bone healing was achieved at two to four months. Frontal deviation was less than 5°. Recurvatum was less than 5° in eight cases, between 5° and 10° in two cases and between 10° and 20° in two others. At mean follow-up of 23 months (3–60), maximal moss of mobility was 10°. There was not worsening of pain. Discussion: Retrograde nailing leads to bone healing with satisfactory frontal alignment and minimal loss of mobility. The approach uses the initial incision, facilitating complementary procedures or revision if needed. The main problem is controlling recurvatum, even though at the follow-up reported there was no clinical impact or loosening. The limitations of this method are well defined: free medullary canal, sufficient knee flexion, compatible femoral component. The tibial obstacle in posterior stabilised implants is less well known; It should be protected during the nailing if it is high. The polyethylene insert may have to be removed temporarily in certain cases. Conclusion: The two principal problems with retrograde nailing are recognising implants compatible with this technique and controlling recurvatum. Results are acceptable with a minimally invasive technique


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 137 - 137
1 Feb 2020
Dessinger G Argenson J Bizzozero P LaCour M Komistek R
Full Access

Introduction. Numerous fluoroscopic studies have been conducted to investigate kinematic variabilities of total knee arthroplasty (TKA). In those studies, subjects having a posterior stabilized (PS) TKA experience greater weightbearing knee flexion and posterior femoral rollback of the lateral condyle. In those same studies, subjects did experience a high incidence of variable medial condyle motion and reverse axial rotation, especially occurring when the cam engaged the post. More recently, a PS TKA was designed to accommodate both gender and ethnicity. Therefore, the objective of this study was to assess in vivo kinematics for subjects having this TKA type to determine if subjects having this PS TKA experienced more optimal knee kinematics. Methods. Twenty-five subjects in this study were asked to perform a deep knee bend to maximum knee flexion and a step-up maneuver while under fluoroscopic surveillance. All subjects were patients of one experienced surgeon and received the same PS TKA. Using a 3D-2D registration technique, the CAD models, supplied by the sponsoring company, were superimposed over x-ray images at specified increments throughout the fluoroscopic footage. The kinematics were then analyzed to evaluate lateral anterior/posterior (LAP) and medial anterior/posterior (MAP) condyle translation as well as axial rotation of the femur with respect to the tibia. Results. During the DKB activity, the average flexion for the PS TKA subjects was 1108°. On average subjects experienced a lateral condyle motion in the posterior direction of 7.3mm, with the maximum amount of posterior rollback being 12.8 mm. These same subjects experienced an average medial condyle motion in the posterior direction of 4.8 mm with the maximum amount of posterior motion being 7.8 mm. Therefore, with the lateral condyle rolling more posterior than the medial condyle, these subjects experienced an average amount of 7.1° of axial rotation, with a maximum of 12.0°. Only one subject in this study experienced a reverse axial rotation from full extension to maximum knee flexion. During the step-up maneuver, subjects consistently experienced a roll forward motion of both their condyles. Discussion. Subjects in this study experienced a high incidence and magnitude of lateral condyle posterior femoral rollback, leading a normal-like axial rotation pattern, although less in magnitude compared to the normal knee. There was variability occurring with the medial condyle as some experience experienced an anterior slide while others rolled in the posterior direction. As seen in previous studies, during mid flexion both condyles experienced a more variable motion pattern. Twenty-five subjects having a posterior cruciate retaining TKA are being added to this study to determine if retention of the PCL in a similarly designed TKA leads to more normal-like kinematic patterns


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 59 - 60
1 Jan 2004
Becquet E Migaud H Giraud F Eddine TA Gougeon F Dequennoy A
Full Access

Purpose: Posterior stabilisation with a third condyle was introduced by Henri Dejour with the HLSI prosthesis. While the posterior stabilisation process has been validated, this implant still raises some problems with the tibial fixation in patients with advanced joint degeneration, leading to the development of the HLSII model. The purpose of the present retrospective work was to evaluate functional outcome and persistance of the HLSII prosthesis fixation. Material and methods: Between January 1992 and December 1993, 105 total knee arthroplasties (TKA) were performed in 94 consecutive patients using posterior stabilised HLSII prostheses. Indications were joint degeneration (40% stage 4) in 78% and polyarthritis in 19%. None of the patients were lost to follow-up but 14 patients died, six were bedridden (stroke sequela) and four were contacted by phone only. In all, 70 patients (77 TKA), mean age 66 years (22–79) were retained for clinical and radiological assessment at mean follow-up of seven years (range 6–8 years). All implants were cemented and the patella was resurfaced in all cases. Eight operators participated in this series. Junior surgeons (n=5) implanted one-third of the prostheses. Results: The mean IKS knee score rose from 27±18 points (0–63) preoperatively to 81±18 (21–100) at last follow-up, function score from 35±20 (0–75) to 64±24 (0–100) (P< 0.0001). Motion changed from 114° (60–140°) to 116° (40–135°) (NS).Eighty-six percent of the patients used stairs (13% without handrail and 28% with alternate steps) versus 52% before the intervention (1% without handrail and 1% with alternate steps). (P=0.001). Knee alignment was normal ±5° in 87% of the cases versus 27% before surgery (P< 0.0001). Seventy-nine percent of the knees had a slope ±2° (desired slope 0°). The patellar retinaculum was sectioned in one quarter of the knees which led to four of the five postoperative haematomas (no revision). Five patellar fractures were noted, including two with patellar loosening (revised) and one clunk (cured after arthroscopic release). Lucent lines observed under the medial tibial plateau in 30% of the cases (all < 1 mm) were more frequent in patients with more severe joint degeneration and genu varus preoperatively (P =0.01). There was no case of aseptic femorotibial loosening. One case of late infection (30 months) was followed by replacement arthroplasty. Survival rate, taking mechanical and/or infectious failure as the endpoint, was 97± 1.3% at 90 months. Discussion: Good axial control emphasises the reliability of the instrumentation since one-third of the prostheses were implanted by junior surgeons. Improvements in tibial fixation with the HLSII appear to be effective, particularly for stage 4 degeneration. Long-term surveillance is however necessary. The femoropatellar joint can give rise to non-infectious complications and should be improved. The concept of posterior stabilisation with a third condyle authorises good flexion amplitude and favours use of stairs


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 23 - 23
1 Mar 2009
Kelalis G Zahariou K Kollintzas L Kalampokis A Morakis A
Full Access

PURPOSE: To record our experience in surgical treatment of thoracic spine fractures with posterior stabilization, decompression and ligamentotaxis. MATERIALS AND METHODS: From January 2000 until July 2006, 67 patients (48 males and 19 females), aged 16 to 85 years old (average 41,2 y.o) were surgically treated in our department due to thoracic spine fractures. Preoperative X-Ray and CT scan were used in all cases while in most of the cases we performed MRI to further evaluate the damage. In all cases we performed decompression and posterior stabilization using four different hardware types and whenever possible ligamentotaxis. Continuous electrophysiological monitoring was alo ued in all operations. We recorded the pre- and postoperative neurological status, the vertebral height loss, the kyphotic angle and spinal canal occupation. Moreover we recorded the average hospitalization time, the transfusion needs as well as major and minor complications. At the follow-up we measured the loss of correction at 3, 6 and 12 months postoperatively. The follow up ranged from 4 to 48 months. RESULTS: Neurological damage was recorded in 43 % of the patients. The average preoperative kyphotic angle was 38.2° while the average spinal canal occupation was 29.8 %. The immediate postoperative correction was 16.7 °. During the follow-up we observed small, insignificant loss of correction. There were no major complications. CONCLUSION: In cases of thoracic spine fractures the surgical treatment with posterior stabilization and ligamentotaxis is offering significant stability and adequate long term results


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 232 - 232
1 Nov 2002
Bowditch M Paterson R
Full Access

Eighteen porous coated posterior stabilized prostheses, inserted without cement or screws have been reviewed. Six were revised within two years. One was infected. The remaining five were revised for persistent symptoms considered to be due to tibial component loosening. Three of the four improved after revision with cementing of the tibial component, the other has remained symptomatic. One patient was lost to follow-up. Clinical review of the remaining eleven was good or excellent at two years. Radiographs at two years, available in eight, revealed that all had a non progressive I mm radio-lucent line at the bone- tibial prosthesis interface. The lack of bony ingrowth and apparent symptomatic early loosening in the four revised, suggests that posterior stabilised tibial prostheses may require additional initial fixation. From our experience in this short series, it is recommend that the tibial component of this prosthesis and perhaps any other posterior stabilized design, be cemented or fixed with screws


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 99 - 99
1 Feb 2020
Schroder F Post C Simonis F Wagenaar F in'tVeld RH Verdonschot N
Full Access

Introduction. Instability, loosening, and patellofemoral pain belong to the main causes for revision of total knee arthroplasty (TKA). Currently, the diagnostic pathway requires various diagnostic techniques such as x-rays, CT or SPECT-CT to reveal the original cause for the failed knee prosthesis, but increase radiation exposure and fail to show soft-tissue structures around TKA. There is a growing demand for a diagnostic tool that is able to simultaneously visualize soft tissue structures, bone, and TKA without radiation exposure. MRI is capable of visualising all the structures in the knee although it is still disturbed by susceptibility artefacts caused by the metal implant. Low-field MRI (0.25T) results in less metal artefacts and offers the ability to visualize the knee in weight-bearing condition. Therefore, the aim of this study is to investigate the possibilities of low field MRI to image, the patellofemoral joint and the prosthesis to evaluate the knee joint in patients with and without complaints after TKA. Method. Ten patients, eight satisfied and two unsatisfied with their primary TKA, (NexGen posterior stabilized, BiometZimmer) were included. The patients were scanned in sagittal, coronal, and transversal direction on a low field MRI scanner (G-scan Brio, 0.25T, Esaote SpA, Italy) in weight-bearing and non-weight-bearing conditions with T1, T2 and PD-weighted metal artefact reducing sequences (TE/TR 12–72/1160–7060, slice thickness 4.0mm, FOV 260×260×120m. 3. , matrix size 224×216). Scans were analysed by two observers for:. - Patellofemoral joint: Caton-Descamps index and Tibial Tuberosity-Trochlear Groove (TT-TG) distance. - Prosthesis malalignment: femoral component rotation using the posterior condylar angle (PCA) and tibial rotation using the Berger angle. Significance of differences in parameters between weight-bearing and non-weight-bearing were calculated with the Wilcoxon rank test. To assess the reliability the inter and intra observer reliability was calculated with a two-way random effects model intra class correlation coefficient (ICC). The two unsatisfied patients underwent revision arthroplasty and intra-operative findings were compared with MRI findings. Results. In the satisfied group, a significant difference was found between TT-TG distance in non-weight-bearing and weight-bearing condition (p=0.018), with a good interrater reliability ICC=0.89. Furthermore, differences between weight-bearing and non-weight-bearing were found for the CD ratio, however, not significant (p=0.093), with a good interrater reliability ICC=0.89. The Berger angle could be measured with an excellent interrater reliability (ICC=0.94). The PCA was hard to assess with a poor interrater reliability (ICC=0.48). For one unsatisfied patient a deviation was found for tibial component rotation, according to the perioperative findings as, ‘malposition of the tibial component’. For the other unsatisfied patient revision surgery was performed due to aseptic loosening in which the MRI showed a notable amount of synovitis. Conclusion. It is possible to image the patellofemoral joint and knee prosthesis with low field MRI. Patellofemoral measurements and tibial component rotation measurements can reliably be performed. For the two patients with complaints MRI findings were consistent with intra-operative findings. Further research should focus on a larger group of patients with complaints after TKA to verify the diagnostic capacity of low field MRI for peri-prosthetic knee problems. For any figures or tables, please contact authors directly


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 5 | Pages 798 - 803
1 Nov 1989
Scuderi G Insall J Windsor R Moran M

The survivorship method of analysis has been used to compare the failure rate and overall success of 1,430 cemented primary total knee arthroplasties performed at The Hospital for Special Surgery over a 15-year period. There were 224 total condylar prostheses with a polyethylene tibia, 289 of the posterior stabilised type with an all polyethylene tibia, and 917 posterior stabilised with a metal-backed tibial component. There were 12 failures in the total condylar series, giving an average annual failure rate of 0.65% and a 15-year success rate of 90.56%. The posterior stabilised prosthesis with a polyethylene tibia showed an average annual failure rate of 0.27% and a 10-year success rate of 97.34%, and this prosthesis with a metal-backed tibial component gave an annual failure rate of 0.19% and a seven-year success rate of 98.75%. The overall survival rate was not influenced by sex or age, diagnosis or the percentage of ideal body weight. No metal-backed tibial components have yet needed revision for loosening. It seems that infection will be the major cause of failure


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_II | Pages 181 - 181
1 Apr 2005
di Vico G Cerciello S Bussiere C Selmi TAS Neyret P
Full Access

This study presents the results of 1188 original and innovative posteriorly stabilized TKA procedures in which the femoral bone stock is preserved with a shallow compartment insofar as possible. The TKA procedure is directly derived from Insall’s original technique, except for the posterior stabilisation design, where a third median condyle starts working at 30° of knee flexion. A total of 1188 primary TKA procedures were consecutively performed in a university hospital. Average follow-up was 30 months (0–168 months). The implants were cemented (except for 35 femoral components) and the patella resurfaced (except for nine cases). Clinical results were assessed using the IKS Score. The quality of the implantation was analysed on long-leg X-rays (1175 preoperative and 883 postoperative long-leg films available at follow-up). The results showed that 95% of patients were very satisfied or at least satisfied. Knee score and functional scores were 44 and 54 preoperatively and 90 and 78 postoperatively. Mean range of motion was 116°. On X-ray analysis, the average mechanical femorotibial angle was 179° postoperatively. Survival of the implant for revision was 94.2% at 14 years. We performed 83 re-operations (nine patellar fractures, 14 infections, 12 cases of stiffness and 11 clunck syndromes), including 33 component revisions. Clinical results compared favourably with the literature. This original posterior stabilisation design confirmed the good and excellent results at follow-up. We obtain good range of motion, and no revision was due to polyethylene wear