header advert
Results 1 - 50 of 3693
Results per page:
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 35 - 35
1 Dec 2013
Conditt M Illgen R
Full Access

While THA is regarded as one of the most successful surgeries in medicine, recent studies have revealed that ideal acetabular cup implantation is achieved as little as 50% of the time. Malalignment of the acetabular component in THA may result in dislocation, reduced range of motion, or accelerated wear. Recently, robotic-assisted surgery has been introduced to reduce the errors in component placement. The purpose of this study is to longitudinally assess the accuracy of cup placement of a single surgeon at three points in time: directly following a total joint fellowship, after 10 years of experience with manual instrumentation, and directly after adopting robotic technology. Three hundred patients received THA at a single center by a single surgeon representing three series of 100 consecutive patients in each series. The first series A included the surgeon's first 100 THA patients following graduation from joint fellowship (2/2000–5/2002). The second series B included the surgeon's last 100 THA patients before adopting robotic technology (12/2010–1/2012) and the final series C included the surgeon's first 100 THA patients using robotic assistance (4/2012–4/2013). The post-operative abduction and version of the cup was measured using PACS imaging software from the AP and cross-table lateral radiographs. Abduction was measured using a transverse line at the level of the teardrop and the lateral opening angle of the cup relative to this reference line. Anteversion was measured using the ischial method described by Schmalzreid on the crosstable lateral view and accounts for pelvic flexion. The average inclination for the groups A, B, and C was 48.6 ± 7.6°, 37.4 ± 6.2°, and 39.6 ± 47.6°, respectively and for anteversion was 29.3 ± 10.3°, 26.6 ± 8.4°, and 23.6 ± 5.7°, respectively. The cup placement in the original series A was within the Lewinnek safe zone only 31% of the time. This increased to 45% in series B and up to 74% in series C (p < 0.05). With the robotic series C, the three-dimensional pre-operative plan was obtained from the software. The average error (final placement–plan) was −0.7 ± 2.1° for inclination and 1.1 ± 2.0° for version. 93% of the inclination measurements and 94% of the version measurements were within 5° of the plan and 100% of both measurements were within 10° of the plan. Of note, 8% of the robotic cases were actually planned outside of the Lewinnek safe zone to accommodate for patient deformity and optimize correction to achieve the targeted combined anteversion of the acetabular and femoral components. Robotic assistance in THA leads to significantly more precise acetabular cup placement. As measured by the Lewinnek safe zone, 10 years of experience resulted in a 45% increase in precision, while adding robotic assistance resulted in a 139% increase in precision compared to the surgeon's initial performance. With greater knowledge of ideal acetabular cup position, highly accurate techniques may allow surgeons to decrease the risk of dislocation, promote durability and improve the ability to restore appropriate leg length and offset


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 323 - 323
1 Apr 2024
Fontalis A Kayani B Plastow R Giebaly DE Tahmassebi J Haddad IC Chambers A Mancino F Konan S Haddad FS


Bone & Joint Research
Vol. 10, Issue 10 | Pages 629 - 638
20 Oct 2021
Hayashi S Hashimoto S Kuroda Y Nakano N Matsumoto T Ishida K Shibanuma N Kuroda R

Aims. This study aimed to evaluate the accuracy of implant placement with robotic-arm assisted total hip arthroplasty (THA) in patients with developmental dysplasia of the hip (DDH). Methods. The study analyzed a consecutive series of 69 patients who underwent robotic-arm assisted THA between September 2018 and December 2019. Of these, 30 patients had DDH and were classified according to the Crowe type. Acetabular component alignment and 3D positions were measured using pre- and postoperative CT data. The absolute differences of cup alignment and 3D position were compared between DDH and non-DDH patients. Moreover, these differences were analyzed in relation to the severity of DDH. The discrepancy of leg length and combined offset compared with contralateral hip were measured. Results. The mean values of absolute differences (postoperative CT-preoperative plan) were 1.7° (standard deviation (SD) 2.0) (inclination) and 2.5° (SD 2.1°) (anteversion) in DDH patients, and no significant differences were found between non-DDH and DDH patients. The mean absolute differences for 3D cup position were 1.1 mm (SD 1.0) (coronal plane) and 1.2 mm (SD 2.1) (axial plane) in DDH patients, and no significant differences were found between two groups. No significant difference was found either in cup alignment between postoperative CT and navigation record after cup screws or in the severity of DDH. Excellent restoration of leg length and combined offset were achieved in both groups. Conclusion. We demonstrated that robotic-assisted THA may achieve precise cup positioning in DDH patients, and may be useful in those with severe DDH. Cite this article: Bone Joint Res 2021;10(10):629–638


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_1 | Pages 68 - 68
1 Jan 2017
Penny J Ding M Ovensen O Overgaard S
Full Access

The metal on metal implants was introduced without the proper stepwise introduction. The ASR resurfacing hip arthroplasty (RHA) withdrawn due to high clinical failure rates and the large diameter head THA (LDH-THA) are also widely abandoned. Early (2 year) radiostereometry studies does not support early instability as cause of failure but more likely metal wear products. A possible advantage may be maintenance of bone mineral density (BMD). We present 5 year prospective follow up from a randomized series, aiming to report changes from baseline and to investigate links between implant micromotion, Cr & Co ions and BMD. Patients eligible for an artificial hip were randomized to RHA, Biomet LDH-THA or standard Biometric THA. 19, 17 and 15 patients completed 5 year follow-up. All followed with BMD of the femur, acetabulum and for RHA the collum. RHA and THA with whole blood Co and Co. LDH-THA only at 5 year. RHA had marker based RSA of both components, cup only for LDH-THA. Translations were compiled to total translation (TT= √(x. 2. +y. 2. +z. 2. )). Data were collected at baseline, 8 weeks, 6 months, 1, 2 and 5 years. Statistical tests: ANCOVA for TT movement, Spearman's correlation for BMD, Cr, Co and BMI to TT at 5 years. RSA: The 5 year median (25%to75%) RHA cup translations were X=-0.00(−0.49 to 0.19) Y=0.15(−0.03 to 0.20), z=0.24(−0.42 to 0.37) and TT 0.58 (0.16 to 1.82) mm. For the LDH-THA X=−0.33(−0.90 to 0.20) Y=0.28(0.02 to 0.54), z=0.43(−1.12 to −0.19) and TT 1.06 (0.97 to 1.72) mm. The TT was statistically different (p<0.05) for the two cups. The RHA femoral component moved X=0.37(0.21 to 0.56) Y=0.02(−0.07 to 0.11), z=-0.01(−0.07 to 0.26) and TT 0.48 (0.29 to 0.60) mm at 5 years. There was no TT movement from year 2. The mean (SD) acetabular BMD was diminished to 93(90–97)% for RHA and 97(93–99.9)% for THA, but LDH-THA maintained 99(95–103)%. Overall femoral BMD was unchanged at 5 years for all interventions, but both stemmed implants lost 17% at the calcar. Median (25%to75%) whole-blood Cr peaked in the LDH-THA group with 1.7 (0.9 to 3.1) followed by RHA 1.2 (0.8 to 5.0) and THA with 0.5 (0.4 to 0.7)ppb. For Co the highest levels were found in RHA with 1.6(0.8 to 4.7) followed by LDH-THA 1.2 (0.7–1.7) and THA 0.2 (0.2 to 0.6) ppb. The only correlations above +/−0.3 for TT were the RHA femoral component with a correlation of 0.47 to BMI, 0.30 to Co and Cr. The ASR cup conversely had a negative correlation of −0.60 to BMI and again, the LDH-THA cup had a negative correlation of −0.37 to Cr. In contrast to registered revision rates, we found significantly larger movement for the Biomet cup than the ASR cup. The metal ion levels were similar. The LDH-THA cup maintained the acetabular BMD best at 5 years, but the difference was small, we are limited by small numbers and the correlations between TT and the covariates showed no clear pattern


The Bone & Joint Journal
Vol. 105-B, Issue 4 | Pages 373 - 381
15 Mar 2023
Jandl NM Kleiss S Mussawy H Beil FT Hubert J Rolvien T

Aims. The aim of this study was to evaluate the diagnostic accuracy of the absolute synovial polymorphonuclear neutrophil cell (PMN) count for the diagnosis or exclusion of periprosthetic joint infection (PJI) after total hip (THA) or knee arthroplasty (TKA). Methods. In this retrospective cohort study, 147 consecutive patients with acute or chronic complaints following THA and TKA were included. Diagnosis of PJI was established based on the 2018 International Consensus Meeting criteria. A total of 39 patients diagnosed with PJI (32 chronic and seven acute) and 108 patients with aseptic complications were surgically revised. Results. Using receiver operating characteristic curves and calculating the area under the curve (AUC), an optimal synovial cut-off value of 2,000 PMN/µl was determined (AUC 0.978 (95% confidence interval (CI) 0.946 to 1)). Using this cut-off, sensitivity and specificity of absolute synovial PMN count for PJI were 97.4% (95% CI 91.2 to 100) and 93.5% (95% CI 88.9 to 98.1), respectively. Positive and negative predictive value were 84.4% (95% CI 72.7 to 93.9) and 99.0% (95% CI 96.7 to 100), respectively. Exclusion of 20 patients with acute complications improved specificity to 97.9% (95% CI 94.6 to 100). Different cut-off values for THA (< 3,600 PMN/µl) and TKA (< 2,000 PMN/µl) were identified. Absolute synovial PMN count correlated strongly with synovial alpha-defensin (AD) (r = 0.759; p < 0.001). With a positive AD result, no additional PJI could be identified in any case. Conclusion. Absolute synovial PMN count is a widely available, rapid, cost-effective, and accurate marker in PJI diagnostics, whereas synovial AD appears to be a surrogate parameter of absolute synovial PMN count. Despite limitations in the early postoperative phase, wear, and rheumatic diseases in confirming PJI, an absolute synovial PMN count below 2,000/µl is highly suitable for ruling out PJI, with specific cut-off values for THA and TKA. Cite this article: Bone Joint J 2023;105-B(4):373–381


Bone & Joint Open
Vol. 5, Issue 3 | Pages 174 - 183
6 Mar 2024
Omran K Waren D Schwarzkopf R

Aims. Total hip arthroplasty (THA) is a common procedure to address pain and enhance function in hip disorders such as osteoarthritis. Despite its success, postoperative patient recovery exhibits considerable heterogeneity. This study aimed to investigate whether patients follow distinct pain trajectories following THA and identify the patient characteristics linked to suboptimal trajectories. Methods. This retrospective cohort study analyzed THA patients at a large academic centre (NYU Langone Orthopedic Hospital, New York, USA) from January 2018 to January 2023, who completed the Patient-Reported Outcomes Measurement Information System (PROMIS) pain intensity questionnaires, collected preoperatively at one-, three-, six-, 12-, and 24-month follow-up times. Growth mixture modelling (GMM) was used to model the trajectories. Optimal model fit was determined by Bayesian information criterion (BIC), Vuong-Lo-Mendell-Rubin likelihood ratio test (VLMR-LRT), posterior probabilities, and entropy values. Association between trajectory groups and patient characteristics were measured by multinomial logistic regression using the three-step approach. Results. Among the 1,249 patients, a piecewise GMM model revealed three distinct pain trajectory groups: 56 patients (4.5%) in group 1; 1,144 patients (91.6%) in group 2; and 49 patients (3.9%) in group 3. Patients in group 2 experienced swift recovery post-THA and minimal preoperative pain. In contrast, groups 1 and 3 initiated with pronounced preoperative pain; however, only group 3 exhibited persistent long-term pain. Multinomial regression indicated African Americans were exceedingly likely to follow trajectory groups 1 (odds ratio (OR) 2.73) and 3 (OR 3.18). Additionally, odds of membership to group 3 increased by 12% for each BMI unit rise, by 19% for each added postoperative day, and by over four if discharged to rehabilitation services (OR 4.07). Conclusion. This study identified three distinct pain trajectories following THA, highlighting the role of individual patient factors in postoperative recovery. This emphasizes the importance of preoperatively addressing modifiable risk factors associated with suboptimal pain trajectories, particularly in at-risk patients. Cite this article: Bone Jt Open 2024;5(3):174–183


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 30 - 30
23 Jun 2023
Shimmin A Plaskos C Pierrepont J Bare J Heckmann N
Full Access

Acetabular component positioning is commonly referenced with the pelvis in the supine position in direct anterior approach THA. Changes in pelvic tilt (PT) from the pre-operative supine to the post-operative standing positions have not been well investigated and may have relevance to optimal acetabular component targeting for reduced risk of impingement and instability. The aims of this study were therefore to determine the change in PT that occurs from pre-operative supine to post-operative standing, and whether any factors are associated with significant changes in tilt ≥13° in posterior direction. 13° in a posterior direction was chosen as that amount of posterior rotation creates an increase in functional anteversion of the acetabular component of 10°. 1097 THA patients with pre-operative supine CT and standing lateral radiographic imaging and 1 year post-operative standing lateral radiographs (interquartile range 12–13 months) were reviewed. Pre-operative supine PT was measured from CT as the angle between the anterior pelvic plane (APP) and the horizontal plane of the CT device. Standing PT was measured on standing lateral x-rays as the angle between the APP and the vertical line. Patients with ≥13° change from supine pre-op to standing post-op (corresponding to a 10° change in cup anteversion) were grouped and compared to those with a <13° change using unpaired student's t-tests. Mean pre-operative supine PT (3.8±6.0°) was significantly different from mean post-operative standing PT (−3.5±7.1°, p<0.001), ie mean change of −7.3±4.6°. 10.4% (114/1097) of patients had posterior PT changes ≥13° supine pre-op to standing post-op. A significant number of patients, ie 1 in 10, undergo a clinically significant change in PT and functional anteversion from supine pre-op to standing post-op. Surgeons should be aware of these changes when planning component placement in THA


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 10 - 10
23 Feb 2023
Hardwick-Morris M Twiggs J Miles B Jones E Bruce WJM Walter WL
Full Access

Dislocation is one of the most common complications in total hip arthroplasty (THA) and is primarily driven by bony or prosthetic impingement. The aim of this study was two-fold. First, to develop a simulation that incorporates the functional position of the femur and pelvis and instantaneously determines range of motion (ROM) limits. Second, to assess the number of patients for whom their functional bony alignment escalates impingement risk. 468 patients underwent a preoperative THA planning protocol that included functional x-rays and a lower limb CT scan. The CT scan was segmented and landmarked, and the x-rays were measured for pelvic tilt, femoral rotation, and preoperative leg length discrepancy (LLD). All patients received 3D templating with the same implant combination (Depuy; Corail/Pinnacle). Implants were positioned according to standardised criteria. Each patient was simulated in a novel ROM simulation that instantaneously calculates bony and prosthetic impingement limits in functional movements. Simulated motions included flexion and standing-external rotation (ER). Each patient's ROM was simulated with their bones oriented in both functional and neutral positions. 13% patients suffered a ROM impingement for functional but not neutral extension-ER. As a result, 48% patients who failed the functional-ER simulation would not be detected without consideration of the functional bony alignment. 16% patients suffered a ROM impingement for functional but not neutral flexion. As a result, 65% patients who failed the flexion simulation would not be detected without consideration of the functional bony alignment. We have developed a ROM simulation for use with preoperative planning for THA surgery that can solve bony and prosthetic impingement limits instantaneously. The advantage of our ROM simulation over previous simulations is instantaneous impingement detection, not requiring implant geometries to be analysed prior to use, and addressing the functional position of both the femur and pelvis


Bone & Joint Open
Vol. 5, Issue 7 | Pages 560 - 564
7 Jul 2024
Meißner N Strahl A Rolvien T Halder AM Schrednitzki D

Aims. Transfusion after primary total hip arthroplasty (THA) has become rare, and identification of causative factors allows preventive measures. The aim of this study was to determine patient-specific factors that increase the risk of needing a blood transfusion. Methods. All patients who underwent elective THA were analyzed retrospectively in this single-centre study from 2020 to 2021. A total of 2,892 patients were included. Transfusion-related parameters were evaluated. A multiple logistic regression was performed to determine whether age, BMI, American Society of Anesthesiologists (ASA) grade, sex, or preoperative haemoglobin (Hb) could predict the need for transfusion within the examined patient population. Results. The overall transfusion rate was 1.2%. Compared to the group of patients without blood transfusion, the transfused group was on average older (aged 73.8 years (SD 9.7) vs 68.6 years (SD 10.1); p = 0.020) and was mostly female (p = 0.003), but showed no significant differences in terms of BMI (28.3 kg/m. 2. (SD 5.9) vs 28.7 kg/m. 2. (SD 5.2); p = 0.720) or ASA grade (2.2 (SD 0.5) vs 2.1 (SD 0.4); p = 0.378). The regression model identified a cutoff Hb level of < 7.6 mmol/l (< 12.2 g/dl), aged > 73 years, and a BMI of 35.4 kg/m² or higher as the three most reliable predictors associated with postoperative transfusion in THA. Conclusion. The possibility of transfusion is predictable based on preoperatively available parameters. The proposed thresholds for preoperative Hb level, age, and BMI can help identify patients and take preventive measures if necessary. Cite this article: Bone Jt Open 2024;5(7):560–564


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 88 - 88
23 Feb 2023
Petterwood J McMahon S Coffey S Slotkin E Ponder C Wakelin E Orsi A Plaskos C
Full Access

Smartphone-based apps that measure step-count and patient reported outcomes (PROMs) are being increasingly used to quantify recovery in total hip arthroplasty (THA). However, optimum patient-specific activity level before and during THA early-recovery is not well characterised. This study investigated 1) correlations between step-count and PROMs and 2) how patient demographics impact step-count preoperatively and during early postoperative recovery. Smartphone step-count and PROM data from 554 THA patients was retrospectively reviewed. Mean age was 64±10yr, BMI was 29±13kg/m2, 56% were female. Mean daily step count was calculated over three time-windows: 60 days prior to surgery (preop), 5–6 weeks postop (6wk), and 11–12 weeks postop (12wk). Linear correlations between step-count and HOOS12 Function and UCLA activity scores were performed. Patients were separated into three step-count levels: low (<2500steps/day), medium (2500-5500steps/day), and high (>5500steps/day). Age >65years, BMI >30, and sex were used for demographic comparisons. Student's t-tests determined significant differences in mean step-counts between demographic groups and in mean PROMs between step-count groups. UCLA correlated with step-count at all time-windows (p<0.01). HOOS12 Function correlated with step-count preoperatively and at 6wk (p<0.01). High vs low step count individuals had improved UCLA scores preoperatively (∆1.8,p<0.001), at 6wk (∆1.1,p<0.05), and 12wk (∆1.6,p<0.01), and improved HOOS12 Function scores preoperatively (∆8.4,p<0.05) and at 6wk (∆8.8,p<0.001). Younger patients had greater step-count preoperatively (4.1±3.0k vs 3.0±2.5k, p<0.01) and at 12wk (5.1±3.3k vs 3.6±2.9k, p<0.01). Males had greater step-count preoperatively (4.1±3.0k vs. 3.0±2.7k, p<0.001), at 6wk (4.5±3.2k vs 2.6±2.5k, p<0.001), and at 12wk (5.2±3.6k vs. 3.4±2.5k, p<0.001). Low BMI patients had greater step-count at 6wk (4.3±3.3k vs. 2.6±2.7k, p<0.01) and 12wk (5.0±3.6k vs. 3.6±2.6k, p<0.05). Daily step-count is significantly impacted by patient demographics and correlates with PROMs, where patients with high step count exhibit improved PROMs. Generic recovery profiles may therefore not be appropriate for benchmarking across diverse populations


The Bone & Joint Journal
Vol. 104-B, Issue 3 | Pages 331 - 340
1 Mar 2022
Strahl A Kazim MA Kattwinkel N Hauskeller W Moritz S Arlt S Niemeier A

Aims. The aim of this study was to determine whether total hip arthroplasty (THA) for chronic hip pain due to unilateral primary osteoarthritis (OA) has a beneficial effect on cognitive performance. Methods. A prospective cohort study was conducted with 101 patients with end-stage hip OA scheduled for THA (mean age 67.4 years (SD 9.5), 51.5% female (n = 52)). Patients were assessed at baseline as well as after three and months. Primary outcome was cognitive performance measured by d2 Test of Attention at six months, Trail Making Test (TMT), FAS-test, Rivermead Behavioural Memory Test (RBMT; story recall subtest), and Rey-Osterrieth Complex Figure Test (ROCF). The improvement of cognitive performance was analyzed using repeated measures analysis of variance. Results. At six months, there was significant improvement in attention, working speed and concentration (d2-test; p < 0.001), visual construction and visual memory (ROCF; p < 0.001), semantic memory (FAS-test; p = 0.009), verbal episodic memory (RBMT; immediate recall p = 0.023, delayed recall p = 0.026), as well as pain (p < 0.001) with small to large effect sizes. Attention, concentration, and visual as well as verbal episodic memory improved significantly with medium effect sizes over η. 2. partial. = 0.06. In these cognitive domains the within-group difference exceeded the minimum clinically important difference. Conclusion. THA is associated with clinically relevant postoperative improvement in the cognitive functions of attention, concentration, and memory. These data support the concept of a broad interaction of arthroplasty with central nervous system function. Cite this article: Bone Joint J 2022;104-B(3):331–340


Full Access

We report the outcome of 320 primary Total Hip Arthroplasties (THA) with minimum 10-year follow-up (range 10–17 years, mean 12.6 years), performed by a single surgeon in Tauranga New Zealand, with the Exeter Contemporary Flanged all-polyethylene cup and Exeter femoral stem via a posterior approach. The aim of the study is to compare the results with the published results from the design centre and create a baseline cohort for further outcomes research in this centre. All patients were prospectively followed at 6 weeks, 1 year, 5 years, 10 years, (and 15 years when available). Of 333 cases that matched the inclusion criteria, 13 procedures in 12 patents were excluded because of concomitant bone grafting and/or supplementary cage fixation, leaving 320 primary THA procedures in 280 patients, including 26 bilateral procedures in 13 patients. Mean follow-up of the surviving cases was 12.6 (range 5.0-17.1) years. There were 12 revisions – 2 for fracture, 5 for instability, 1 for impingement pain and 4 for infection. There were no revisions for aseptic cup loosening. Kaplan-Meier survivorship with revision for aseptic loosening as the endpoint was 100% at 15.0 years (with minimum 40 cases remaining at risk). All-cause acetabular revision in 12 cases result in a Kaplan-Meier survival of 95.9% (95% CI: 93.5 to 98.3%). Cemented THA with the Exeter Contemporary Flanged cup and the Exeter stem is a durable combination with results that can be replicated outside of the design centre. The Exeter Contemporary Flanged cup has excellent survivorship at 15 years when used with the Exeter stem. Cemented THA with well-proven components should be considered the benchmark against which newer designs and materials should be compared


Bone & Joint Open
Vol. 4, Issue 1 | Pages 3 - 12
4 Jan 2023
Hardwick-Morris M Twiggs J Miles B Al-Dirini RMA Taylor M Balakumar J Walter WL

Aims. Iliopsoas impingement occurs in 4% to 30% of patients after undergoing total hip arthroplasty (THA). Despite a relatively high incidence, there are few attempts at modelling impingement between the iliopsoas and acetabular component, and no attempts at modelling this in a representative cohort of subjects. The purpose of this study was to develop a novel computational model for quantifying the impingement between the iliopsoas and acetabular component and validate its utility in a case-controlled investigation. Methods. This was a retrospective cohort study of patients who underwent THA surgery that included 23 symptomatic patients diagnosed with iliopsoas tendonitis, and 23 patients not diagnosed with iliopsoas tendonitis. All patients received postoperative CT imaging, postoperative standing radiography, and had minimum six months’ follow-up. 3D models of each patient’s prosthetic and bony anatomy were generated, landmarked, and simulated in a novel iliopsoas impingement detection model in supine and standing pelvic positions. Logistic regression models were implemented to determine if the probability of pain could be significantly predicted. Receiver operating characteristic curves were generated to determine the model’s sensitivity, specificity, and area under the curve (AUC). Results. Highly significant differences between the symptomatic and asymptomatic cohorts were observed for iliopsoas impingement. Logistic regression models determined that the impingement values significantly predicted the probability of groin pain. The simulation had a sensitivity of 74%, specificity of 100%, and an AUC of 0.86. Conclusion. We developed a computational model that can quantify iliopsoas impingement and verified its accuracy in a case-controlled investigation. This tool has the potential to be used preoperatively, to guide decisions about optimal cup placement, and postoperatively, to assist in the diagnosis of iliopsoas tendonitis. Cite this article: Bone Jt Open 2023;4(1):3–12


Bone & Joint Open
Vol. 3, Issue 12 | Pages 991 - 997
23 Dec 2022
McPherson EJ Stavrakis AI Chowdhry M Curtin NL Dipane MV Crawford BM

Aims. Large acetabular bone defects encountered in revision total hip arthroplasty (THA) are challenging to restore. Metal constructs for structural support are combined with bone graft materials for restoration. Autograft is restricted due to limited volume, and allogenic grafts have downsides including cost, availability, and operative processing. Bone graft substitutes (BGS) are an attractive alternative if they can demonstrate positive remodelling. One potential product is a biphasic injectable mixture (Cerament) that combines a fast-resorbing material (calcium sulphate) with the highly osteoconductive material hydroxyapatite. This study reviews the application of this biomaterial in large acetabular defects. Methods. We performed a retrospective review at a single institution of patients undergoing revision THA by a single surgeon. We identified 49 consecutive patients with large acetabular defects where the biphasic BGS was applied, with no other products added to the BGS. After placement of metallic acetabular implants, the BGS was injected into the remaining bone defects surrounding the new implants. Patients were followed and monitored for functional outcome scores, implant fixation, radiological graft site remodelling, and revision failures. Results. Mean follow-up was 39.5 months (36 to 71), with a significant improvement in post-revision function compared to preoperative function. Graft site remodelling was rated radiologically as moderate in 31 hips (63%) and strong in 12 hips (24%). There were no cases of complete graft site dissolution. No acetabular loosening was identified. None of the patients developed clinically significant heterotopic ossification. There were twelve reoperations: six patients developed post-revision infections, three experienced dislocations, two sustained periprosthetic femur fractures, and one subject had femoral component aseptic loosening. Conclusion. Our series reports bone defect restoration with the sole use of a biphasic injectable BGS in the periacetabular region. We did not observe significant graft dissolution. We emphasize that successful graft site remodelling requires meticulous recipient site preparation. Cite this article: Bone Jt Open 2022;3(12):991–997


The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 929 - 937
1 Aug 2022
Gurung B Liu P Harris PDR Sagi A Field RE Sochart DH Tucker K Asopa V

Aims. Total hip arthroplasty (THA) and total knee arthroplasty (TKA) are common orthopaedic procedures requiring postoperative radiographs to confirm implant positioning and identify complications. Artificial intelligence (AI)-based image analysis has the potential to automate this postoperative surveillance. The aim of this study was to prepare a scoping review to investigate how AI is being used in the analysis of radiographs following THA and TKA, and how accurate these tools are. Methods. The Embase, MEDLINE, and PubMed libraries were systematically searched to identify relevant articles. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for scoping reviews and Arksey and O’Malley framework were followed. Study quality was assessed using a modified Methodological Index for Non-Randomized Studies tool. AI performance was reported using either the area under the curve (AUC) or accuracy. Results. Of the 455 studies identified, only 12 were suitable for inclusion. Nine reported implant identification and three described predicting risk of implant failure. Of the 12, three studies compared AI performance with orthopaedic surgeons. AI-based implant identification achieved AUC 0.992 to 1, and most algorithms reported an accuracy > 90%, using 550 to 320,000 training radiographs. AI prediction of dislocation risk post-THA, determined after five-year follow-up, was satisfactory (AUC 76.67; 8,500 training radiographs). Diagnosis of hip implant loosening was good (accuracy 88.3%; 420 training radiographs) and measurement of postoperative acetabular angles was comparable to humans (mean absolute difference 1.35° to 1.39°). However, 11 of the 12 studies had several methodological limitations introducing a high risk of bias. None of the studies were externally validated. Conclusion. These studies show that AI is promising. While it already has the ability to analyze images with significant precision, there is currently insufficient high-level evidence to support its widespread clinical use. Further research to design robust studies that follow standard reporting guidelines should be encouraged to develop AI models that could be easily translated into real-world conditions. Cite this article: Bone Joint J 2022;104-B(8):929–937


The Bone & Joint Journal
Vol. 104-B, Issue 7 | Pages 859 - 866
1 Jul 2022
Innocenti M Smulders K Willems JH Goosen JHM van Hellemondt G

Aims. The aim of this study was to explore the relationship between reason for revision total hip arthroplasty (rTHA) and outcomes in terms of patient-reported outcome measures (PROMs). Methods. We reviewed a prospective cohort of 647 patients undergoing full or partial rTHA at a single high-volume centre with a minimum of two years’ follow-up. The reasons for revision were classified as: infection; aseptic loosening; dislocation; structural failure; and painful THA for other reasons. PROMs (modified Oxford Hip Score (mOHS), EuroQol five-dimension three-level health questionnaire (EQ-5D-3L) score, and visual analogue scales for pain during rest and activity), complication rates, and failure rates were compared among the groups. Results. The indication for revision influenced PROMs improvement over time. This finding mainly reflected preoperative differences between the groups, but diminished between the first and second postoperative years. Preoperatively, patients revised due to infection and aseptic loosening had a lower mOHS than patients with other indications for revision. Pain scores at baseline were highest in patients being revised for dislocation. Infection and aseptic loosening groups showed marked changes over time in both mOHS and EQ-5D-3L. Overall complications and re-revision rates were 35.4% and 9.7% respectively, with no differences between the groups (p = 0.351 and p = 0.470, respectively). Conclusion. Good outcomes were generally obtained regardless of the reason for revision, with patients having the poorest preoperative scores exhibiting the greatest improvement in PROMs. Furthermore, overall complication and reoperation rates were in line with previous reports and did not differ between different indications for rTHA. Cite this article: Bone Joint J 2022;104-B(7):859–866


The Bone & Joint Journal
Vol. 106-B, Issue 1 | Pages 69 - 76
1 Jan 2024
Tucker A Roffey DM Guy P Potter JM Broekhuyse HM Lefaivre KA

Aims. Acetabular fractures are associated with long-term morbidity. Our prospective cohort study sought to understand the recovery trajectory of this injury over five years. Methods. Eligible patients at a level I trauma centre were recruited into a longitudinal registry of surgical acetabular fractures between June 2004 and August 2019. Patient-reported outcome measures (PROMs), including the 36-Item Short Form Health Survey (SF-36) physical component summary (PCS), were recorded at baseline pre-injury recall and six months, one year, two years, and five years postoperatively. Comparative analyses were performed for elementary and associated fracture patterns. The proportion of patients achieving minimal clinically important difference (MCID) was determined. The rate of, and time to, conversion to total hip arthroplasty (THA) was also established. Results. We recruited 251 patients (253 fractures), with a 4:1 male to female ratio and mean age of 46.1 years (SD 16.4). Associated fracture patterns accounted for 56.5% of fractures (n = 143). Trajectory analysis showed all timepoints had significant disability versus baseline, including final follow-up (p < 0.001). Elementary fractures had higher SF-36 PCS at six months (p = 0.023) and one year (p = 0.007) compared to associated fractures, but not at two years (p = 0.135) or five years (p = 0.631). The MCID in SF-36 PCS was observed in 37.3% of patients (69/185) between six months and one year, 26.9% of patients (39/145) between one and two years, and 23.3% of patients (20/86) between two and five years, highlighting the long recovery potential of these injuries. A significant proportion of patients failed to attain the MCID after five years (38.1%; 40/105). Conversion to THA occurred in 13.1% of patients (11/110 elementary and 22/143 associated fractures). Approximately two-thirds of THAs (21/33 patients; 63.6%) were performed within two years of index surgery. Conclusion. Acetabular fractures significantly impact physical function. Recovery trajectory is often elongated beyond one year, with two-thirds of our patients displaying persistent clinically relevant long-term disability. Cite this article: Bone Joint J 2024;106-B(1):69–76


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 55 - 55
1 Jun 2018
Su E
Full Access

Acetabular implant position is important for the stability, function, and long-term wear properties of a total hip arthroplasty (THA). Prior studies of acetabular implant positioning have demonstrated a high percentage of outliers, even in experienced hip surgeons, when conventional instruments are used. Computer navigation is an attractive tool for use in THA, as it has been shown to improve the precision of acetabular component placement and reduce the incidence of outliers. However, computer navigation with imageless, large-console systems is costly and often interrupts the surgeon's workflow, and thus, has not been widely adopted. Another method to improve acetabular component positioning during THA is the use of fluoroscopy with the direct anterior approach. Studies have demonstrated that the supine position of the patient during surgery facilitates the use of fluoroscopic guidance, thus improving acetabular component position. A handheld, accelerometer-based navigation unit for use in total hip replacement has recently become available to assist the surgeon in positioning the acetabular component during anterior approach THA, potentially reducing the need for intra-operative fluoroscopic studies. We sought to compare the radiographic results of direct anterior THA performed with conventional instrumentation vs. handheld navigation to determine the accuracy of the navigation unit, and to see whether or not there was a reduction in the fluoroscopic time used during surgery. Furthermore, we timed the use of the navigation unit to see whether or not it required a substantial addition to surgical time. Our results demonstrate that a handheld navigation unit used during anterior approach THA had no difference with regard to acetabular cup positioning when compared to fluoroscopically assisted THA, but led to a reduction in the use of intra-operative fluoroscopy time


Bone & Joint Open
Vol. 2, Issue 8 | Pages 679 - 684
2 Aug 2021
Seddigh S Lethbridge L Theriault P Matwin S Dunbar MJ

Aims. In countries with social healthcare systems, such as Canada, patients may experience long wait times and a decline in their health status prior to their operation. The aim of this study is to explore the association between long preoperative wait times (WT) and acute hospital length of stay (LoS) for primary arthroplasty of the knee and hip. Methods. The study population was obtained from the provincial Patient Access Registry Nova Scotia (PARNS) and the Canadian national hospital Discharge Access Database (DAD). We included primary total knee and hip arthroplasties (TKA, THA) between 2011 and 2017. Patients waiting longer than the recommended 180 days Canadian national standard were compared to patients waiting equal or less than the standard WT. The primary outcome measure was acute LoS postoperatively. Secondarily, patient demographics, comorbidities, and perioperative parameters were correlated with LoS with multivariate regression. Results. A total of 11,833 TKAs and 6,627 THAs were included in the study. Mean WT for TKA was 348 days (1 to 3,605) with mean LoS of 3.6 days (1 to 98). Mean WT for THA was 267 days (1 to 2,015) with mean LoS of 4.0 days (1 to 143). There was a significant increase in mean LoS for TKA waiting longer than 180 days (2.5% (SE 1.1); p = 0.028). There was no significant association for THA. Age, sex, surgical year, admittance from home, rural residence, household income, hospital facility, the need for blood transfusion, and comorbidities were all found to influence LoS. Conclusion. Surgical WT longer than 180 days resulted in increased acute LoS for primary TKA. Meeting a shorter WT target may be cost-saving in a social healthcare system by having shorter LoS. Cite this article: Bone Jt Open 2021;2(8):679–684


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_7 | Pages 28 - 28
1 Apr 2017
Jones R
Full Access

As the American population ages and a trend toward performing total hip arthroplasty (THA) in younger patients continues, the number of Americans undergoing THA is projected to increase over time. The advent of the bundled payment system combined with the current medical utilization climate has placed considerable pressure on surgeons to produce excellent results with early functional recovery and short hospital stays. The US obesity epidemic has transcended into the arthroplasty patient population and surgeons must assess whether obesity is a risk factor for poor outcomes in THA and determine how it should be managed. We performed a recent literature review to determine how obesity impacts outcomes in total hip arthroplasty and what must be done to improve outcomes in the obese arthroplasty patient. Our goal is to answer 3 questions: does obesity increase the complication rate in THA, if obesity matters how obese is too obese, and what must be done to improve outcomes in the obese patient?. Ultimately, obesity has been shown to correlate with increased post-operative complications in THA. The arthroplasty surgeon must optimise the obese patient prior to surgery by identifying associated comorbidities and consider malnutrition screening with counseling. Notice should be taken of the degree of obesity as patients with BMI > 40 have demonstrated much higher complication rates. Strong consideration should be given to avoiding direct anterior approach in the obese patient. Healthy weight loss must be encouraged with appropriate patient counseling and treatment in order to achieve success with THA in obese patients.  


Bone & Joint Open
Vol. 2, Issue 7 | Pages 535 - 539
15 Jul 2021
Zak SG Lygrisse K Tang A Meftah M Long WJ Schwarzkopf R

Aims. As our population ages, the number of octogenarians who will require a total hip arthroplasty (THA) rises. In a value-based system where operative outcomes are linked to hospital payments, it is necessary to assess the outcomes in this population. The purpose of this study was to compare outcomes of elective, primary THA in patients ≥ 80 years old to those aged < 80. Methods. A retrospective review of 10,251 consecutive THA cases from 2011 to 2019 was conducted. Patient-reported outcome (PRO) scores (Hip disability and Osteoarthritis Outcome Score (HOOS)), as well as demographic, readmission, and complication data, were collected. Results. On average, the younger cohort (YC, n = 10,251) was a mean 61.60 years old (SD 10.71), while the older cohort (OC, n = 609) was 84.25 years old (SD 3.02) (p < 0.001). The OC had greater surgical risk based on their higher mean American Society of Anesthesiologists (ASA) scores (2.74 (SD 0.63) vs 2.30 (SD 0.63); p < 0.001) and Charlson Comorbidity Index (CCI) scores (6.26 (SD 1.71) vs 3.87 (SD 1.98); p < 0.001). While the OC stayed in the hospital longer than the YC (mean 3.5 vs 2.5 days; p < 0.001), there were no differences in 90-day emergency visits (p = 0.083), myocardial infarctions (p = 0.993), periprosthetic joint infections (p = 0.214), dislocations (p = 0.993), or aseptic failure (p = 0.993). The YC was more likely to be readmitted within 90 days (3.88% vs 2.18%, Β = 0.57; p = 0.048). There were no observed differences in 12-week (p = 0.518) or one-year (p = 0.511) HOOS scores. Conclusion. Although patients ≥ 80 years old have a greater number of comorbidities than younger patients, they had equivalent perioperative complication rates and PRO scores. This study demonstrates the safety and success of elective THA in octogenarians. Cite this article: Bone Jt Open 2021;2(7):535–539


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 359 - 364
1 Apr 2024
Özdemir E de Lange B Buckens CFM Rijnen WHC Visser J

Aims. To investigate the extent of bone development around the scaffold of custom triflange acetabular components (CTACs) over time. Methods. We performed a single-centre historical prospective cohort study, including all patients with revision THA using the aMace CTAC between January 2017 and March 2021. A total of 18 patients (18 CTACs) were included. Models of the hemipelvis and the scaffold component of the CTACs were created by segmentation of CT scans. The CT scans were performed immediately postoperatively and at least one year after surgery. The amount of bone in contact with the scaffold was analyzed at both times, and the difference was calculated. Results. The mean time between the implantation and the second CT scan was two years (1 to 5). The mean age of the patients during CTAC implantation was 75 years (60 to 92). The mean scaffold-bone contact area increased from 16% (SD 12.6) to 28% (SD 11.9). The mean scaffold-bone distance decreased from a mean of 6.5 mm (SD 2.0) to 5.5 mm (SD 1.6). None of the CTACs were revised or radiologically loose. Conclusion. There was a statistically significant increase of scaffold-bone contact area over time, but the total contact area of the scaffold in relation to the acetabular bone remained relatively low. As all implants remained well fixed, the question remains to what extend the scaffold contributes to the observed stability, in relation to the screws. A future design implication might be an elimination of the bulky scaffold component. This design modification would reduce production costs and may optimize the primary fit of the implant. Cite this article: Bone Joint J 2024;106-B(4):359–364


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 87 - 87
1 Jan 2016
Nishikawa H Sukezaki F
Full Access

Femoral trans-trochanteric rotational osteotomy(TRO) is widely used for the younger patients who have idiopathic osteonecrosis of femoral head. However, it usually converts to THA, and in hip arthroplasty, the procedure is commonly technically demanding and surgeon needs higher level of surgical technique. This study was designed to investigate comparison between simple THA and THA following TRO, and indicates specific surgical techniques of THA following TRO. Materials and Methods. Between 2002 and 2012, the senior authors performed 20 cementless THA in 16 patients who had followed after TRO. The operation time, blood loss, post-operative X-ray findings, and overall clinical results (JOA score) were investigated. These data were compared with simple THA following 10 years. Results. A mean duration between TRO and THA was 58 month, a mean age at the time of THA was 52.1 years old. Pre-operative classification was all Type C and stage 2 or higher stage. Osteonecrosis of femoral head before THA was mean 56.2%. Operation time was 160 minutes, and mean blood loss was 764 g. In post-operative X-ray findings, a cup was at original anatomy in place in all cases. There is a tendency of slight varus femoral stem position after THA following TRO. The JOA score was improved from 42.1 to 74.2. Discussion. Technically, there are a couple of issues in THA following TRO. Specific surgical techniques are needed. Surgical results depend on hip range of motion before THA. There is a difficulty of improvements in ROM after THA following TRO


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 62 - 62
1 Feb 2017
Kida D Ito T Kito Y Hattori Y Takahashi N Matsubara M
Full Access

Introduction. Accurate acetabular cup orientation could lead to successful surgical results in total hip arthroplasty (THA). We introduce a novel CT-based three-dimensional (3D) planning system, HipCOMPASS (Fig.1) and TARGET (Fig.2), which enable to design suitable alignment not only cup also surgical devices calculatingly, according to each pelvic inclination. Patients and Methods. We performed THA in 45 hips in 43 patients (female 37 and 6 men) between April 2014 and October 2015. Average age were 68 years old. THA operation was based on each parameter of the cup and device, providing a preoperative planning by ZedView system. HipCOMPASS and TARGET is linked with ZedView software, which is simultaneously calibrated adjustable parameters on this devices. Cup alignment was assessed by ZedView as well. Results. The differences of component alignment from the preoperative planning were shown in Tables. Conclusion. HipCOMPASS and TARGET might be more accurate than conventional method and more accessible system than navigation system in THA


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_22 | Pages 31 - 31
1 Dec 2016
Kraay M
Full Access

Arthritis of the hip is a relatively common problem in patients with neuromuscular disorders due to muscle imbalance around the hip from weakness, paralysis, contractures and spasticity. Neuromuscular disorders such as cerebral palsy, Parkinson's disease, poliomyelitis, previous cerebrovascular accident (CVA) and Charcot arthropathy have been considered by many to be contraindications to total hip arthroplasty (THA). The presence of certain anatomic abnormalities (excessive femoral anteversion, acetabular dysplasia, leg length discrepancy (LLD) and coax valga) and significant soft tissue contractures, muscle imbalance, and muscular weakness make THA a challenging surgical procedure in this patient population, and can predispose to dislocation and poor functional outcome following surgery. THA can, however, result in substantial pain relief and functional improvement, and can be safely performed, provided certain technical considerations are addressed. The patient's motor strength and functional status (ambulatory vs. “sitter”) should be carefully assessed preoperatively, since both of these factors may affect the choice of surgical approach and component position. Significant soft tissue contractures should be released at the time of surgery. Although these can be frequently performed “open”, percutaneous adductor tenotomy is occasionally necessary for patients with significant adduction contractures. Patients requiring significant soft tissue releases may benefit from 6 weeks of bracing to allow soft tissues to heal in appropriately and minimise risk of dislocation during this period of time. Use of modular femoral components that allow for correction of excessive femoral anteversion, should be considered in patients with coexistent dysplasia and neuromuscular disease (i.e., CP or polio). Large femoral head components should also be considered in patients with increased risk factors for dislocation. Despite their obvious theoretical advantages, the use of large head metal on metal THAs should be used with extreme caution in view of growing concerns about these devices. Although constrained acetabular liners are associated with an increased risk of mechanical failure, their use should be strongly considered in patients with significant motor weakness or major soft tissue deficiencies. Meticulous soft tissue closure of the capsule of the hip is recommended, especially when performing THA through a posterior approach. Patients with neuromuscular disorders associated with spasticity and involuntary movements need to be optimally treated medically prior to and indefinitely after THA. There are limited reports of outcomes following THA in patients with neuromuscular disorders, however, some generalizations based on underlying diagnosis can be made. Patients with cerebral palsy and polio frequently have acetabular dysplasia, excessive femoral anteversion and LLD, and although durability does not seem to be a major concern, dislocation and instability is relatively common and needs to be addressed. Durability and instability do not appear to be major concerns in patients with Parkinson's disease, however, these patients have frequent medical complications perioperatively and have deterioration in function over time due to the progressive nature of their underlying disorder. Patients with previous CVA also appear to have acceptable durability and dislocation risk, but are at high risk of developing heterotopic ossification postoperatively. Patients with Charcot arthropathy or myelodysplasia are at high risk of instability and appear to have limited functional improvement following THA. As a result, the consensus of opinion is that THA is contraindicated in these patients


The Bone & Joint Journal
Vol. 102-B, Issue 7 Supple B | Pages 27 - 32
1 Jul 2020
Heckmann N Weitzman DS Jaffri H Berry DJ Springer BD Lieberman JR

Aims. Dual mobility (DM) bearings are an attractive treatment option to obtain hip stability during challenging primary and revision total hip arthroplasty (THA) cases. The purpose of this study was to analyze data submitted to the American Joint Replacement Registry (AJRR) to characterize utilization trends of DM bearings in the USA. Methods. All primary and revision THA procedures reported to AJRR from 2012 to 2018 were analyzed. Patients of all ages were included and subdivided into DM and traditional bearing surface cohorts. Patient demographics, geographical region, hospital size, and teaching affiliation were assessed. Associations were determined by chi-squared analysis and logistic regression was performed to assess outcome variables. Results. A total of 406,900 primary and 34,745 revision THAs were identified, of which 35,455 (8.7%) and 8,031 (23.1%) received DM implants respectively. For primary THA, DM usage increased from 6.7% in 2012 to 12.0% in 2018. Among revision THA, DM use increased from 19.5% in 2012 to 30.6% in 2018. Patients < 50 years of age had the highest rates of DM implantation in every year examined. For each year of increase in age, there was a 0.4% decrease in the rate of DM utilization (odds ratio (OR) 0.996 (95% confidence interval (CI) 0.995 to 0.997); p < 0.001). Females were more likely to receive a DM implant compared to males (OR 1.077 (95% CI 1.054 to 1.100); p < 0.001). Major teaching institutions and smaller hospitals were associated with higher rates of utilization. DM articulations were used more commonly for dysplasia compared with osteoarthritis (OR 2.448 (95% CI 2.032 to 2.949); p < 0.001) during primary THA and for instability (OR 3.130 (95% CI 2.751 to 3.562) vs poly-wear; p < 0.001) in the revision setting. Conclusion. DM articulations showed a marked increase in utilization during the period examined. Younger patient age, female sex, and hospital characteristics such as teaching status, smaller size, and geographical location were associated with increased utilization. DM articulations were used more frequently for primary THA in patients with dysplasia and for revision THA in patients being treated for instability. Cite this article: Bone Joint J 2020;102-B(7 Supple B):27–32


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 95 - 95
1 May 2016
Kida D Ito T Kito Y Hattori Y Matsubara M
Full Access

Introduction. Accurate acetabular cup orientation could lead to successful surgical results in total hip arthroplasty (THA). We introduce a novel CT-based three-dimensional (3D) planning system, HipCOMPASS (Fg.1) and TARGET (Fig.2), which enable to design suitable alignment not only cup also surgical devices calculatingly, according to each pelvic inclination. Patients and methods. We performed THA in 13 patients (10 female and 3 men) between September 2014 and April 2014. Average age were 67 years old. THA operation was based on each parameter of the cup and device, providing a preoperative planning by ZedView system. HipCOMPASS and TARGET is linked with ZedView software, which is simultaneously calibrated adjustable parameters on this devices. Cup alignment was assessed by ZedView as well. Result. The differences of component alignment from the preoperative planning were shown in table. Conclusion. HipCOMPASS and TARGET might be more accurate than conventional method and more accessible system than navigation system in THA


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_7 | Pages 7 - 7
1 Apr 2017
Lieberman J
Full Access

An outpatient total hip arthroplasty (THA) will be defined as a THA performed at an ambulatory care facility where the patient is discharged the same day as the procedure. Such procedures are being done in the United States and the hypothesis is that a “same day” THA will lead to reduced costs and improved outcomes. However, there are no appropriately powered randomised controlled trials evaluating outcomes in this group of patients to support this hypothesis. It appears that a “same day” THA is here to stay. Therefore, the selection criteria for patients that undergo the procedure needs to be carefully defined. The safety of this regimen needs to be confirmed. In an evaluation of the NSQIP database, Otero et al. compared outcomes in patients discharged on POD 0 and POD 1 and noted that THA patients in the POD 0 group had increased rates of complications. Risk factors for complications included age >70, smoking, COPD, CAD and hematocrit less than 36. In addition, the patients discharged on POD 0 had higher rates of diabetes, steroid use and lower hematocrit. Clearly, the selection criteria for this procedure needs to be defined. In two separate studies, Goyal et al. and Dorr et al. noted that approximately 25% of patients were unable to leave the hospital on POD 0 usually because of nausea and/or hypertension. Issues to consider before developing a same day discharge program include: 1) Is the patient healthy enough to go home the same day as the surgery?; 2) Does the patient live close enough to the hospital to be discharged the same day?; 3) Can the family provide the appropriate care for the patient at home?; 4) Is it really better for the patient or just better for the surgeon?. If a surgeon embarks on a same day discharge program, rigorous selection criteria must be instituted and followed. In addition, the patient must have free choice with respect to a same day discharge versus a 24-hour stay


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_13 | Pages 86 - 86
1 Nov 2015
Berry D
Full Access

The goal is to avoid letting femoral deformity force suboptimal implant position/fixation. Suboptimal implant position has an adverse effect on hip biomechanics and often on hip function and durability. Classification - Practical approach to femoral deformities: categorise into 3 main groups: 1.) Very proximal, 2.) Subtrochanteric, 3.) Distal. Management of distal deformities: Most can be ignored if there is sufficient room to place conventional femoral implant. Management of proximal deformities: Option 1: Use implants that allow satisfactory positioning despite deformity…or… Option 2: Remove the deformity. Management of subtrochanteric level deformities: These are the most difficult. Problems: 1.) Too proximal to ignore, 2.) Too distal to bypass. Main treatment options: 1.) Resurfacing THA, 2.) Short stem THA, 3.) Corrective osteotomy with THA. Corrective osteotomy with THA: 1.) Perform osteotomy at level of deformity, 2.) In most cases a corrective osteotomy that creates a transverse osteotomy junction is simplest, 3.) Use an implant that provides reliable fixation in the femur (usually uncemented), 4.) Use implant that provides fixation of the proximal and distal fragments. Majority of proximal femoral deformities managed with one-stage procedure: 1.) Excise deformity and replace with metal, 2.) Implants that allow ignoring deformity, 3.) Corrective osteotomy


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 83 - 83
1 Jan 2016
Chotanaphuti T Khuangsirikul S Nuansalee N
Full Access

Osteolysis is one of a major cause of failure that affect long term survival rate in THA. Hard-on-hard bearing surface were developed to reduce wear and osteolysis, such as ceramic-on-ceramic which is the lowest wear rate was introduced but it still has squeaking and ceramic fracture. Metal-on-metal bearing surface significantly reduce wear rate but it still release metal ion which affect local tissue reaction. Then ceramic-on-metal is another choice of bearing with combine the advantage of reduce wear rate, metal ion release, no stripe wear, no squeaking and no ceramic fracture. However after clinical use ALTRs may occur and disturb the longevity of THA. During January 2009 to December 2009 we performed 98 THR with the same femoral stem and acetabular cup with difference bearing which were 87 cases of metal on cross-linked PE, 8 cases of ceramic on metal and 5 cases of metal on metal. Routinely postoperative care were done with clinical evaluation, plain x-rays and Harris hip score. After 5 years follow up there are clinical problems in ceramic on metal THA with decrease clinical score and progressive osteolysis in radiographic finding in 2 cases then we investigated to find the cause of this problem and revise the components. We preformed magnetic resonance imaging and collect blood sample for ESR, CRP and Cobalt and Chromium level. We revised 2 cases of ceramic on metal THA, during surgery we collected tissue for bacterial and AFB and histopathology. All retrieval components were studied for wear pattern. First patient have thigh pain and progressive osteolysis after year 4. th. of follow up. She had normal ESR and CRP with high level of cobalt and chromium level. We revised both components and tissue histopathology showed metallosis with chronic inflammation. Another patient had failure due to ALTRs with mixed solid-cystic mass at trochanteric bursa but component is stable then only bearing surface were change. Wear pattern at femoral head was in weight bearing area with corresponding to apical center wear of metal liner. Our study showed that only in group of ceramic-on-metal THA that have 5 years follow up have early reoperation due to osteolysis and tissue reaction. We routinely stop to use this bearing since 2010. But we have small number of cases in our study to conclude that is bearing are not suitable for clinical usage


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 19 - 19
1 Jan 2016
Hachiya Y Watanabe H Taniguchi S Muramatsu K Tanaka K Yoshioka A Ando K
Full Access

(Introduction). Metal on Metal (MoM) THA bearing as the second generation Total Hip Arthroplasty, widely came into use in Japan since 2000s. And it was expected to be able to ensure long-term use, the range of motion in the joints after surgeries, and the resistance to the dislocation, because MoM THAhad been considered to be able to use the large diameter head for its lower wear. However, there are some reports that the metal wear debris from MoM bearing surface generates the elevated serum ion level in the blood and the incidence of pseudotumor may occur subsequent to the metal wear debris. We performed MoM THA for 291 joints in 234 patients in our hospital since May 2005. But now, we refrain to use this. In this time, we will describe two cases of pseudotumor after implantation of MoM THA. (Case1) Age 64 years, female. This case showed the hip osteoarthritis on the right side, and we performed MoM THA in 2005. After that, she had slipped just prior to the three-year postoperative check-up, andstarted swelling up, hip joint pain, and the rise in CRP. Then, we performed to remove pesudotumor in 2008 and her CRP turned into negative. However, she was repeating hip dislocation several times and an MRI showed recur of pseudotumor. Finally, we changed her metal liner into a polyethylene liner in 2012. (Case2) Age 57 years, female. This case showed the hip osteoarthritis on the bilateral side, and we performed MoM THA in 2005. We had regularly measured her serum ion levels since 2009, and her cobalt level was indicating high concentration. In addition, there was shown 46ng/ml blood concentration of cobalt in her postoperative check-up in 2013. In 2014, she came to our hospital with chief complaint of the pain in the right groin, and we confirmed pseudotumor with MRI. (Conclusion). Nowadays, there have been various reports regarding the formation of mass lesion around the joint implants with MoM bearing, and the incidence rates, the methods of the diagnosis, and the treatment policies are introduced. However, they are realistically still not standardized. For this reason, we should fully understand the properties of MoM THA to perform the surgeries. And there is a need to be performed CT scans, MRI and ultrasound examination for the patients who claim a pain or the sense of discomfort in the area after surgery


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 392 - 392
1 Jul 2011
Hakki S
Full Access

Proximal load fixation in THA is paramount for maximum bone preservation and thus longevity of the implant. Conventional femoral stems may not achieve satisfactory proximal fixation in proximal/ distal femoral canal mismatch as in champagne type of femur, mal-united fractures, excessively bowed femur and some young large patients. Such mismatch can lead to uneven loading and a higher incidence of loosening or periprosthetic fracture. This risk is becoming higher with the recent trend to mini-invasive surgery. As an alternative to standard stem, the short stem femoral prosthesis was originally developed in the 1950’s and has recently been making a resurgence as a design conducive to the minimal invasive techniques, and allows for greater preservation of the natural anatomy. Our objective is to measure the clinical and radiological outcomes of the Metha. ®. hip short stem (a cementless, metaphyseal fix conserving diaphysis implant) with computer assisted technique and minimal invasive surgical approach. This study is a single center, open label, data collection study of 35 consecutive subjects undergoing OrthoPilot. ®. navigation, Metha. ®. stem plasmapore cup system with minimal invasive muscle sparing surgical approach. (B. Braun Aesculap; Tuttlingen, Germany). Pre-Operatively an IRB Informed Consent, no exclusion specific to the implant, Harris Hip Evaluation and routine hip/pelvis plain xray was performed. Post-Operatively, a CT Scan within 6 months, repeat Harris Hip Score (HHS) Evaluation. The implant is made of titanium alloy with plasmapore coating in @ 2/3 of the implant (< 8 cm engages in proximal femur with a total length average of 10.75 cm)(range 9.75–11.75). The bearing surface is metal/ highly cross linked polyethylene. Size 32 head of modular neck with plasmapore shell. All cases were done thru muscle sparing anterolateral mini invasive approach. At 6 months ± 1 month with an average age = 67, BMI= 37 (one was 360 pounds), Harris score was 46 preop and 96 post op.No thigh pain, No dislocation, Trendelenberg negative. Patient satisfaction was high. One fell had a non displaced fx of the neck that did not require revision but slowed full weight bearing for 6 weeks. One subsided in a 360 pound patient after he went full wt bearing while getting out of the shower a week after surgery. This was revised with a standard stem. The tip of two implants was discovered to have penetrated the proximal femur with no symptoms at 3 months period and no restriction to weight bearing during that period. This happened in the first 5 cases in which we modified technique with no other penetrations. Xray/CT scan showed no subsidence good bony ingrowth no radiolucency or loosening. The two penetrated corteses showed intense bony overgrowth on the two protruded tips of stem. We conclude that cementless metaphyseal short stem with proximal plasmapore coating is associated with excellent clinical and radiological results. The technical errors we faced in the early two cases were identified and avoided by using awl canal finder with suction tube palpation of canal and direct visualization of the metaphyses before hammering the broach. The combination of the short stem prosthesis, modularity of the neck, computer assisted technique and minimal invasive arthroplasty is expected to reduce recovery time, increase the potential for successful restoration of function and add to the longevity of the prosthetic joint


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 19 - 19
1 Jun 2018
Garbuz D
Full Access

Intra-operative fractures of the femur are on the rise mainly due to the increased use of cementless implants and the desire to get a tight press fit. The prevalence has been reported to be between 1–5% in cementless THAs. The key to preventing these fractures is to identify patients at high risk and careful surgical technique. Surgical risk factors include the use of cementless devices, revision hip surgery, the use of flat tapered wedges and MIS surgery. Patient factors that increased risk include increasing age, female gender, osteopenia and rheumatoid arthritis. These risk factors tend to be additive and certainly when more than one is present extra caution needs to be taken. Surgical technique is critical to avoid these intra-operative fractures. Fractures can occur during exposure and dislocation, during implant removal (in revision THA), during canal preparation and most commonly during stem insertion. In both primary, and especially in revision, THA be wary of the stiff hip in association with osteopenia or osteolysis. These patients require a very gentle dislocation. If this cannot be achieved, then alteration of the standard approach and dislocation may be needed. Examples of these include protrusion with an osteopenic femur and revision THA with a very stiff hip with lysis in the femur. Lastly, in cases with retained hardware, dislocate prior to removing plates and screws. After dislocation, the next challenge is gentle preparation of the femoral canal. A reasonable exposure is required to access the femoral canal safely. MIS procedures do not offer good access to femoral canal and this probably results in increased risk of fracture during broaching or implant insertion. When broaching, stop when broach will not advance further. When inserting a tapered wedge stem, be worried if stem goes further in than broach. In revision surgery, when taking the stem out from above, make sure the area of the greater trochanter does not overhang the canal. A high speed burr can clear the shoulder for easier access for removal. In revision THA with an ETO, place a cerclage wire prior to reaming and retighten prior to stem insertion. Even with careful surgical technique intra-operative femoral fractures will still occur. When inserting the stem, a sudden change in resistance is highly suggestive of fracture. Wide exposure of the entire proximal femur is necessary to confirm the diagnosis. The distal extent of the fracture must be seen. Only on occasion is an intra-operative radiograph needed. Management is directed to ensuring component stability and good fracture fixation. In primary total hip arthroplasty, calcar fractures are by far the most common. If using proximal fixation and you are certain the stem is stable, then all that is needed is cerclage wiring. As already mentioned, you must follow the fracture line distally so you are aware of how far down it goes. Often what appears to be a calcar split actually propagates distal to the lesser trochanter. In these cases, one would probably go for distal fixation plus wiring. In conclusion, intra-operative femoral fractures are on the rise. Prevention is the key


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_8 | Pages 36 - 36
1 May 2014
Kraay M
Full Access

Arthritis of the hip is a relatively common problem in patients with neuromuscular disorders due to muscle imbalance around the hip from weakness, paralysis, contractures and spasticity. Neuromuscular disorders such as cerebral palsy, Parkinson's disease, poliomyelitis, previous cerebrovascular accident (CVA) and Charcot arthropathy have been considered by many to be relative contraindications to total hip arthroplasty (THA). The presence of certain anatomic abnormalities (excessive femoral anteversion, acetabular dysplasia, leg length discrepancy (LLD) and coax valga) and significant soft tissue contractures, muscle imbalance, and muscular weakness make THA a challenging surgical procedure in this patient population, and can predispose to dislocation and poor functional outcome following surgery. THA can, however, result in substantial pain relief and functional improvement in patients with significant hip arthritis and neuromuscular disorders, and can be safely performed, provided certain technical considerations are addressed. The patient's motor strength and functional status (ambulatory vs. “sitter”) should be carefully assessed pre-operatively, since both of these factors may affect the choice of surgical approach and component position. Significant soft tissue contractures should be released at the time of surgery. Although these can be frequently performed “open”, percutaneous adductor tenotomy is occasionally necessary for patients with significant adduction contractures. Patients requiring significant soft tissue releases may benefit from 6 weeks of bracing to allow soft tissues to heal appropriately and minimise risk of dislocation during this period of time. Use of modular femoral components that allow for correction of excessive femoral anteversion, should be considered in patients with coexistent dysplasia and neuromuscular disease (i.e. CP or polio). Large femoral head components should also be considered in patients with increased risk factors for dislocation. Despite their obvious theoretical advantages, the use of large head metal on metal THAs should be used with extreme caution in view of growing concerns about these devices. Although constrained acetabular liners are associated with an increased risk of mechanical failure, their use should be strongly considered in patients with significant motor weakness or major soft tissue deficiencies. Meticulous soft tissue closure of the capsule of the hip is recommended, especially when performing THA through a posterior approach. Patients with neuromuscular disorders associated with spasticity and involuntary movements need to be optimally treated medically prior to and indefinitely after THA. There are limited reports of outcomes following THA in patients with neuromuscular disorders, however some generalisations based on underlying diagnosis can be made. Patients with cerebral palsy and polio frequently have acetabular dysplasia, excessive femoral anteversion and LLD, and although durability does not seem to be a major concern, dislocation and instability is relatively common and needs to be addressed. Durability and instability do not appear to be major concerns in patients with Parkinson's disease, however, these patients have frequent medical complications perioperatively and have deterioration in function over time due to the progressive nature of their underlying disorder. Patients with previous CVA also appear to have acceptable durability and dislocation risk, but are at high risk of developing heterotopic ossification postoperatively. Patients with Charcot arthropathy or myelodysplasia are at high risk of instability and appear to have limited functional improvement following THA. As a result, the consensus of opinion is that THA is contraindicated in patients with Charcot arthropathy and myelodysplasia


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_17 | Pages 85 - 85
1 Nov 2016
Berry D
Full Access

Introduction: The goal is to avoid letting femoral deformity force suboptimal implant position/fixation. Suboptimal implant position has an adverse effect on hip biomechanics and often on hip function and durability. Classification: Practical approach to femoral deformities: categorise into 3 main groups: Very proximal, Subtrochanteric, Distal. Management: Management of distal deformities: Most can be ignored if there is sufficient room to place conventional femoral implant. Management of proximal deformities: Option 1: Use implants that allow satisfactory positioning despite deformity…or… Option 2: Remove the deformity. Management of subtrochanteric level deformities: These are the most difficult. Problems: Too proximal to ignore, Too distal to bypass. Main treatment options: Resurfacing THA, Short stem THA, Corrective osteotomy with THA. Corrective osteotomy with THA: Perform osteotomy at level of deformity, In most cases a corrective osteotomy that creates a transverse osteotomy junction is simplest, Use an implant that provides reliable fixation in the femur (usually uncemented), Use implant that provides fixation of the proximal and distal fragments. Conclusions: Majority of proximal femoral deformities managed with one-stage procedure: Excise deformity and replace with metal, Implants that allow ignoring deformity, Corrective osteotomy


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_23 | Pages 26 - 26
1 Dec 2016
Thomas A Koenraadt K Joosten P van Geenen R Bolder S
Full Access

Aim. Prosthetic joint infection (PJI) is a major complication in THA. Nasal carriage with S. Aureus is a well-defined risk factor for infection in hospitalized patients. Risk for infection is reduced up to 50% by eradication therapy. Since PJI rates are very low and only 25% of the population are carriers, significant differences are hard to show and reports on PJI have been inconclusive. We analysed the effect of S. Aureus eradication therapy in THA. Methods. From 2011, patients receiving THA are screened for S. Aureus carriage and carriers are treated. This group was retrospectively compared with a historical THA group in which no screening and eradication therapy was done. We assumed similar carrier rates in both groups and calculated the risk reduction of eradication therapy for PJI in comparison to the historical carriers without treatment. Fisher's Exact test was used to compare outcome. Results. 2072 patients were screened and 478 patients were positive (23%). The historical control group consisted of 1248 patients, with 288 calculated carriers (23%). 15 PJI (0.72%) occurred vs 14 (1.12%) in the historical group (p=0.16). A 52% reduction in S. Aureus infections was found (0.33% vs 0.64% p=0.15). Infection rates for PJI caused by S. aureus was similar in non-carriers and carriers after eradication therapy (0.3 vs 0.4% p=0.506). The calculated infection rates in carriers in the historical group was reduced from 2.6% to 0.8% (RR 3,25, p=0.07) by eradication therapy and from 1.7% to 0,4% (RR 4,25, p=0.07) for S. Aureus PJI. Conclusions. A clear trend in reduction of PJI was demonstrated as a result of S. aureus screening and eradication therapy, reducing the rate of PJI for carriers to the same level as non-carriers


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 54 - 54
1 Feb 2017
Brown M Plate J Holst D Bracey D Bullock M Lang J
Full Access

Background. Fifteen to twenty percent of patients presenting for total hip arthroplasty (THA) have bilateral disease. While simultaneous bilateral THA is of interest to patients and surgeons, debate persists regarding its merits. The majority of previous reports on simultaneous bilateral THA involve patients in the lateral decubitus position, which require repositioning, prepping and draping, and exposure of a fresh wound to pressure and manipulation for the contralateral THA. The purpose of this study was to compare complications, component position, and financial parameters for simultaneous versus staged bilateral THAs using the direct anterior approach (DAA). Methods. Medical records were reviewed for patient demographics, medical history, operative time, estimated blood loss (EBL), change in hemoglobin, transfusion, tranexamic acid (TXA) use, length of stay (LOS), discharge disposition, leg length discrepancy, acetabular cup position, and perioperative complications. Cost and reimbursement data were analyzed. Results. Forty-four patients were included in the sequential group and fifteen patients in the simultaneous group (Figure 1). Operative time was significantly longer for simultaneous DAA THA, with procedures lasting 260 +/− 48 minutes compared to 132 +/− 30 minutes for a single arthroplasty in the sequential group (p<0.001). Patients undergoing simultaneous bilateral DAA THA also had a significantly higher EBL (p<0.001), hemoglobin drop (p<0.001), and blood transfusion rate (p<0.01) compared to parameters for a single arthroplasty in the sequential group. This was despite TXA being used in a significantly higher proportion of simultaneous procedures compared to sequential procedures (p<0.01). The LOS was significantly longer in patients undergoing simultaneous bilateral DAA THA (2.9 +/− 1.0 days) compared to sequential (2.2 +/− 0.6 days) (p<0.001). No deep venous thrombosis (DVT) or pulmonary embolism (PE) was detected in either group during the observation period. No significant difference was detected regarding perioperative complications or whether patients were able to be discharged home instead of to a post-inpatient facility (Figure 2). There was no significant difference in component position, complications, or readmissions between groups. Total cost per hip was significantly less for the simultaneous ($15,565 +/− 1,470) compared to the sequential group ($19,602 +/− 3,094) (p<0.001). There was no significant difference in total payments between the simultaneous group ($25,717 +/− 4,404) and the sequential group ($24,926 +/− 8,203) (p=0.93). Thus, with lower cost and similar reimbursement, profit per hip was significantly higher for the simultaneous ($9,606 +/− 5,060) compared to the sequential group ($5,324 +/− 7,997) (p<0.05). (Figure 3). Conclusions. Significant data regarding simultaneous bilateral THA has been published but results are conflicting and different surgical approaches were used. To our knowledge only four previous reports have been published examining simultaneous bilateral THA performed via the DAA. While simultaneous DAA THA presents challenges, our results suggest that simultaneous DAA THA may add value to the healthcare system without resulting in increased complications compared to sequential hip arthroplasty


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 96 - 96
1 Nov 2018
Frayssinet A Petta D Eglin D D'Este M Mosser G Helary C
Full Access

Collagen and hyaluronic acid are two major components of intervertebral disc (IVD). They give resistance and hydration to Nucleus Pulposus. In this study, we assessed the impact of Collagen (COLL) and Hyaluronic acid-Tyramine (THA) contents on the mechanical properties and the structure of composite hydrogels. For this purpose, a range of composites were obtained using a 4 mg/mL collagen concentration and different COLL/THA ratios from 8:1 to 1:5 (w/w). Composite gelling was performed by pH increase, triggering collagen fibrillogenesis and oxidative coupling of tyramine moieties in THA catalyzed by H. 2. O. 2. and horseradish peroxidase (HRP). To modulate the THA gelling kinetic, different HRP concentrations (0.05; 0.1 and 0.5 U/mL) were used. Composites with a low THA content exhibited a fibrillar structure and possessed mechanical properties close to those of pure collagen hydrogels (200 Pa). From the ratio 1:1, the storage modulus increased to reach c.a 1200 Pa for the ratio 1:5. From the ratio 1:2, the fibrillar structure disappeared and sheets, characteristic of THA hydrogels, were observed. The HRP activity dramatically impacted the physical properties. A rapid THA gelling associated with a high THA content tended to destabilize collagen fibrils and promoted the formation of covalent bond between collagen and THA. On the opposite a slow gelling kinetic favored collagen fibril formation up to the COLL/THA ratio 1:2. Taken together, these results show that a slow gelling and an 8 mg/mL THA concentration are the appropriate conditions to obtain biomimetic biomaterials for the treatment of Nucleus Pulposus


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 105 - 105
1 Mar 2009
Lazovic D Dunai F Kaib N
Full Access

Malposition of cups and stems in THA leads to a higher rate of dislocation and wear, to leg length discrepancies and to a higher revision rate. Surgical navigation of the implant components should lead to a more accurate position of THA. 1481 consecutive THA were evaluated from November 2001 to June 2006. In a first series until December 2002 127 THA with navigated cups were compared with 110 manually implanted THA. In a second series all following 766 THA with navigated cups were compared to 384 THA with both navigated cup and stem. Navigated surgery was done as a routine procedure by all surgeons, from residents to consultants. Evaluation was done for radiographs, clinical results, the navigation system data for cup anteversion and inclination, centre of rotation, leg lengthening, offset and antetorsion of the stem, technical exclusions and intra- and postoperative complications as dislocation, seroma, thrombosis and duration of surgery. The results showed a better alignment in inclination and anteversion of navigated cups compared to non navigated cups and additional improvement when cup and stem were navigated. In stem navigation a good control of the leg lengthening and a reliable prediction of the safe range of motion could be seen. The overall dislocation rate was 0.3% in the navigated groups after December 2002. Thrombosis, seroma and infection were seen in a very low rate in all groups


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_22 | Pages 33 - 33
1 May 2013
Kraay M
Full Access

Arthritis of the hip is a relatively common problem in patients with neuromuscular disorders due to muscle imbalance around the hip from weakness, paralysis, contractures and spasticity. Neuromuscular disorders such as cerebral palsy, Parkinson's disease, poliomyelitis, previous cerebrovascular accident (CVA) and Charcot arthropathy have been considered by many to be relative contraindications to total hip arthroplasty (THA). The presence of certain anatomic abnormalities (excessive femoral anteversion, acetabular dysplasia, leg length discrepancy (LLD) and coax valga) and significant soft tissue contractures, muscle imbalance, and muscular weakness make THA a challenging surgical procedure in this patient population, and can predispose to dislocation and poor functional outcome following surgery. THA can, however, result in substantial pain relief and functional improvement in patients with significant hip arthritis and neuromuscular disorders, and can be safely performed, provided certain technical considerations are addressed. The patient's motor strength and functional status (ambulatory vs. “sitter”) should be carefully assessed pre-operatively, since both of these factors may affect the choice of surgical approach and component position. Significant soft tissue contractures should be released at the time of surgery. Although these can be frequently performed “open,” percutaneous adductor tenotomy is occasionally necessary for patients with significant adduction contractures. Patients requiring significant soft tissue releases may benefit from 6 weeks of bracing to allow soft tissues to heal in appropriately and minimize risk of dislocation during this period of time. Use of modular femoral components that allow for correction of excessive femoral anteversion, should be considered in patients with coexistent dysplasia and neuromuscular disease (i.e. CP or polio). Large femoral head components should also be considered in patients with increased risk factors for dislocation. Despite their obvious theoretical advantages, the use of large head metal on metal THAs should be used with extreme caution in view of growing concerns about these devices. Although constrained acetabular liners are associated with an increased risk of mechanical failure, their use should be strongly considered in patients with significant motor weakness or major soft tissue deficiencies. Meticulous soft tissue closure of the capsule of the hip is recommended, especially when performing THA through a posterior approach. Patients with neuromuscular disorders associated with spasticity and involuntary movements need to be optimally treated medically prior to and indefinitely after THA. There are limited reports of outcomes following THA in patients with neuromuscular disorders, however some generalisations based on underlying diagnosis can be made. Patients with cerebral palsy and polio frequently have acetabular dysplasia, excessive femoral anteversion and LLD, and although durability does not seem to be a major concern, dislocation and instability is relatively common and needs to be addressed. Durability and instability do not appear to be major concerns in patients with Parkinsons disease, however, these patients have frequent medical complications perioperatively and have deterioration in function over time due to the progressive nature of their underlying disorder. Patients with previous CVA also appear to have acceptable durability and dislocation risk, but are at high risk of developing heterotopic ossification post-operatively. Patients with Charcot arthropathy or myelodysplasia are at high risk of instability and appear to have limited functional improvement following THA. As a result, the consensus of opinion is that THA is contraindicated in patients with Charcot arthropathy and myelodysplasia


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 86 - 86
1 May 2017
Meessen J Peter W Gorissen I Cannegieter S Tilbury C Wolterbeek R Verdegaal S Vermeulen H van der Linden H Dekker J Tordoir R Onstenk R Benard M Meijer V Slagboom P Nelissen R Vlieland TV
Full Access

Objective. Total Hip Arthroplasty (THA) and Total Knee Arthroplasty (TKA) bring relief of pain and functional disability to patients with end stage osteoarthritis, however the literature on their impact on patients’ level of physical activity (PA) is scarce. Methods. Cross-sectional study, performed in 2012, in 515 patients who underwent THA/TKA surgery in 2010–2011 and a random sample of persons aged >40 years from the Dutch general population participating in a national survey in the same period. PA in minutes per week (min/week) and adherence to the Dutch recommendation for health enhancing PA was measured by means of the Short QUestionnaire to ASsess Health enhancing PA (SQUASH) Additional assessments included socio-demographic characteristics, the presence of comorbidities, BMI and Short Form-12. Multivariable linear (total min/week) and logistic regression analyses (meeting PA recommendation), adjusting for confounders, were performed for THA and TKA separately. Results. 258 THA patients (64% female, mean age 70.0 (SD9.2)), 221 TKA patients (67% female, mean age 70.2 (SD8.9)) and 4373 persons from the general population sample (52% female, age 59.0 (SD12.0)) were included. In both regression analyses, the presence of joint arthroplasty was statistically significantly associated with more total min/week spent on PA (THA 7.0% increase, 95%-CI (2.0%–12.6%); TKA 7.4% increase, 95%-CI (1.6%–13.4%)) and a higher chance of adherence with PA recommendations (THA OR 1.90, 95%-CI (1.12–3.03); TKA OR 1.94, 95%-CI (1.19–3.15)). Conclusion. 6-18 months after surgery, THA/TKA patients were more physically active than a random sample of persons >40 years from the Dutch general population


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 58 - 58
1 May 2016
Suksathien Y Suksathien R
Full Access

Background. The short stem prosthesis showed good results in patients with primary osteoarthritis. However, there were a few studies about the short stem THA in patients with osteonecrosis of the femoral head (ONFH). Objective. To evaluate the clinical and radiographic results of the short stem THA in patients with ONFH. The authors hypothesized that the short stem THA would be a promising procedure for patients with ONFH. Material and Method. The authors reviewed 120 osteonecrotic hips in 93 patients who underwent THA with Metha® short stem from November 2010 to February 2013. The appearance of bone trabeculae development and radiolucent line was reviewed using Gruen's classification. The Harris hip score (HHS) was recorded at 6, 12, 24 and 36 months postoperative for evaluating the clinical results. Results. The mean age of patients was 44.4 years (18–68) with the mean BMI of 22.7 (15.1–32.5, SD 3.5). The average follow-up period was 29.2 months (20–47). The mean HHS was significantly improved from 43.9 (22.7–74, SD 7.7) preoperatively to 97.7 (85.9–100, SD 2.7) at 6 months postoperatively (p<0.01). The radiographic change around the stems showed bone trabeculae development at zone 1 (77 cases)(64.2%), 2 (27 cases)(22.5%), 3 (106 cases)(88.3%), 6 (120 cases)(100%) and 7 (115 cases)(95.8%). There was 1 case (0.8%) of 5 mm subsidence and the radiolucent line was observed in zone 1. There were 6 cases (5%) of intraoperative femoral fractures and were treated with cerclage wires, no further subsidence was observed. There was 1 case (0.8%) of distal stem perforation which had stable bone ingrowth. No revision was required. Conclusion. The clinical and radiographic results of the short stem THA in patients with ONFH are generally satisfactory. Its design enables preservation of the bone stock and the bone trabeculae appear to confirm the assumption of proximal force transmission. The authors believe that the short stem THA is a promising procedure for patients with ONFH


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_13 | Pages 88 - 88
1 Nov 2015
Penenberg B
Full Access

The transgluteal approach (TG) offers a user-friendly alternative to the heavily promoted anterior approach (DA) to total hip arthroplasty (THA). Our purpose is to illustrate the advantages and details of the technique, illustrate the surgical anatomy that differentiates TG from the “traditional posterior” technique, and point out the surprising similarities to the DA. Unlike the traditional posterior THA, the TG preserves ITB, quadratus, and obturator externus. The conjoined tendon is released, providing direct access to the femur via the piriformis fossa. Direct acetabular access is facilitated either by using a portal through which reaming and cup impaction are performed or offset instrumentation. Intra-operative digital radiography was used in all cases. We present the clinical and radiographic outcome of 850 consecutive primary THA using the TG. At 2–6 years follow-up, dislocation rate was 0.3%, cup abduction 35–50 degrees in 97%, 92% used a cane within 5 days, 61% reported driving within the first post-operative week. No intra-operative trochanteric fractures, nerve injuries, or wound problems were observed. Three calcar fractures were wired. Hospital stay averaged 1.5 days, no patient received a blood transfusion if their pre-operative hematocrit was normal, and 88% of patients were discharged on acetaminophen only. The TG is a reliable and highly successful alternative to commonly used soft tissue sparing approaches in THA. It permits accelerated recovery while assuring optimal component orientation. The surgeon familiar with the traditional posterior approach can embark on a gradual learning curve that can minimise the complication rate as the surgeon learns the technique


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 94 - 94
1 Jan 2016
Osadebe U Brekke A Ismaily S Loya-Bodiford K Gonzalez J Stocks G Mathis KB Noble P
Full Access

Background. With the rising demand for primary total hip arthroplasty (THA), there has been an emphasis on reducing the revision burden and improving patient outcomes. Although studies have shown that primary THA effectively minimizes pain and restores normal hip function for activities of daily living, many younger patients want to participate in more demanding activities after their operation. The purpose of this study was to examine the relationship between age, gender and patient satisfaction after total hip arthroplasty. Methods. With IRB approval, 2 groups of subjects were enrolled in this study: (i) 143 patients at an average of 25 months (range 10–69 months) post-primary THA, and (ii) 165 control subjects with no history of hip surgery or hip pathology. All subjects were assigned to one of four categories according to their age and gender: Group A: 40–60 year old males (31 THA; 42 Controls), Group B: 40–60 year old females (25 THA; 53 Controls), Group C: 60–80 year old males (35 THA; 25 Controls), and Group D: 60–80 year old females (36 THA; 23 Controls). Each patient completed a self-administered Hip Function Questionnaire (HFQ) which assessed each subject's satisfaction, expectations, symptoms and ability to perform a series of 94 exercise, recreational and daily living activities. These included participation in work-out activities, adventure and water sports, running and biking, and contact and team sports. Each participant was also asked their activity frequency, symptom prevalence and satisfaction with their hip in performing each activity. Results. When compared to controls, more THA patients reported at least weekly pain (20% vs. 7% p=0.001), stiffness (16% vs. 9% p=0.06), and dependence on analgesics at least weekly (8% vs. 5% p=0.42). Males age 40–60 were the only subgroup to differ significantly from their comparators in regards to pain, stiffness, or analgesic use (pain: 29% vs. 7% p=0.02; stiffness: 29% vs. 5% p=0.007; analgesics: 19% vs. 2% p=0.04). Looking at frequency of pain, more controls were dissatisfied than THA patients (64% vs 21% p=0.02). There were 12% of THA patients reporting their hip does not feel normal compared to 6% of controls (p=0.06); elderly males reported this more frequently than controls (p=0.016) and their elderly female counterparts (p=0.028). Of the effect modifiers tested, sensation of an abnormal hip (p=0.03) and frequent stiffness (p=0.003) portend lower satisfaction ratings while history of THA leads to better satisfaction rating vs. Control (p< 0.0001). Age and sex groups (p=0.33), the presence of pain (p=0.13), and analgesic use (p=0.16) were not significant modifiers. Discussion. Residual symptoms, especially stiffness, and the sensation that their hip is not normal after THA are negatively impact patient satisfaction, yet they are not uncommon in THA patients. Young THA males tend to experience more postoperative symptoms, however they remain satisfied and tolerate these symptoms well. Older THA males are less likely to report a normal feeling hip, but are generally satisfied with the outcome of THA


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 166 - 166
1 Sep 2012
Schreurs W
Full Access

Background. Because of the long life expectancy of young total hip arthroplasty (THA) patients and the limited durability of prosthetic implants in young patients, surgeon's always must take into account that the primary THA will be revised in the future. Therefore, not only the survival of the primary total hip in young patients is important, but we would also like to accentuate the revisability of a primary THA in this specific and high demanding patient population. Methods. Based on our philosophy, we always use cemented hip in young patients, if needed with acetabular bone impaction grafting. 343 consecutive cemented THA in 270 patients under the age of 50 years were evaluated, all implanted between 1988 and 2006. We also assessed the results of the revised THA (n=53) within the same population. Clinical, radiographical and survival of primary and revision THA were evaluated. Outcome. Survival analysis of all 343 hips with endpoint revision for any reason of either component showed a survival of 86% after 10 years. Survival of the stem and cup with endpoint aseptic loosening 93% after 10 years. Remarkably, the THA in which the cemented cup was combined with acetabular bone impaction grafting had a survival of 90% (SE 2.8) in contrast to a survival of 82% (SE 3.4) of the cups without an acetabular revision with endpoint revision for any reason of the whole prostheses(log-rank test, p=0.156) at 10 years. With no patient lost during follow-up, 53 primary hips were revised after a mean follow-up of 8.9 (range 2.0–19.3) years. The average follow-up of the revision THA was 4.2 (range 0.1–14.8) years. Three hips of this revision cohort needed a repeat revision, two had a reinfection after a septic revision and one revised cup failed 12 years after revision. The survival of the revised cohort with endpoint revision for any reason was 91% after 5 years, with endpoint aseptic loosening the survival at 5 years was 100 %. As well after primary as revision THA good clinical outcome scores were measured. Interpretation. Cemented implants in young patients showed satisfying results in primary as well as after revision THA with very acceptable survival and clinical outcomes. Keeping in mind that the young patient will outlive their primary THA, the primary hip has to be revisable and the results of the revision THA must be as good as the primary THA. Bone defects both in primary and revision THA can be successful managed with impacted bone grafts, without the need for augments, cages or larger implants


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 189 - 189
1 Mar 2013
Hafez M Bekhet R Rashad I
Full Access

Introduction. The purpose of this retrospective study was to review the outcome of THA in the treatment of bilateral hip ankylosis of different causes; surgical, septic or spontaneous. Methods & Material. 20 THA procedures in 10 patients were included in the study, 5 males and 5 females all had bilateral fusion. Previous pathologies included: ankylosing spondylitis, AVN, septic arthritis and surgical arthrodesis. Flexion deformity ranged (10°-45°). Shortening as compared to normal anatomy was up to 6 cm and leg length discrepancy (LLD) ranged from 1 cm to 2.5 cm. Most unified X-ray finding was massive osteophytes formation with 3 patients showing severe narrowing of the femoral canal. Operative time averaged 147 minutes (70–210) and lateral approach was used in all patients, anesthesia was general with only 3 undergoing spinal anesthesia. Results. Serious complications were reported and were related to the correction of LLD; 1 incidence of sciatic nerve injury that recovered in one year, and another incidence of femoral nerve injury (sensory > motor) that recovered within 3 months, and one case of incomplete correction of LLD. At 5 years follow up (minimum 6 month), there is no loosening or revision. Discussion. The conversion of bilateral fused hip joints to THA is a very rewarding surgery but with higher risk of complications


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 171 - 171
1 Mar 2010
ZHOU Y
Full Access

Dislocation after THA is the most common complication in modern THA, The reported failure rate of reoperation for recurrent instability is higher than any other indication for revision surgery. Treatment of dislocation after THA. Non-operative treatment. The first episode of dislocation after THA is usually treated by close reduction with or without brace treatment. There is no agreement about the role and effectiveness of bracing. Generally, bracing is indicated in the following circumstances:. First dislocation. Early laxity. No component malposition. Patients with poor general condition. The main management issues are about managing recurrent instability. Treatment choice is often complex and management begins by identifying the cause of instability. Causes to consider:. Component issue. Impingement. Soft tissue imbalance. Laxtiy. Abductor weakness. Trochanteric non-uion. Surgical Treatment. The decision to use operative treatment to stabilize the hip joint is complex and the surgeon must take into consideration:. How many times the hip dislocated. Interveral between dislocation. How long after THA the dislocation occur. Can the problem be solved by an operation. Operative risks. Treatment choices depends on the underlying mechanism of dislocation:. Correction of malposition. Correction of soft tissue laxity. Release contractures. Addressing problems of impingement. Using a large femoral head. Constrained liners


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 148 - 148
1 Jan 2016
Sawada N Yabuno K Kanazawa M
Full Access

The alumina on alumina articulation in THA has induced less macrophage reaction and cytokine section than polyethylene bearings. Thus THA using alumina on almina articulation has induced little periprosthetic osteolysis. However alumina fracture is still a concern. We had underwent 100 THAs that it was a cemented polyethylene backed acetabular component with an alumina inlay(ABS Cup; Kyocera, Kyoto, Japan), PHS stem(Kyocera) and 28mm alumina femoral head. This system was formerly used in only Japan, over 10 years results have not reported yet. We retrospectively reviewed 94 patients(100 hips) with cemented alumina on alumina THAs to identify factors relating to alumina failure, and to evaluate mid-term(>10years) results. 16 patients died from unrelated causes within 10 years of the operation and 14 patients was lost to follow up. The remaining 70 patients(79 Hips) were evaluated after a mean follow-up of 10 years. We performed clinical evaluation using the JOA score, and radiological evaluation was performed that inclination and anteversion angle of cup measurement with 2D template system at anteroposterior radiograph. On the radiographs at the final examination, radiolucency and osteolysis were evaluated around the acetabular component, and around the femoral component. These evaluations were scheduled for 3,6,9, and 12 months and yearly thereafter. All the operations were performed by same surgeon, at same center. Cumulative survival rates were calculated using the Kaplan-Meier method with failure defined as the end point of revision for alumina failure or for any reason. To compare groups with and without alumina failures in age, BMI, gender, activity, function, abduction angle, size of component, or existence of radiolucent lines, we used the nonparametric Mann-Whitney U-test. The mean age of the patients at surgery was 63.0 years. The mean follow up term was 13.8 years. Inclination and anteversion mean angle of cup were 45.6°and 14.2°.ã��Revision surgery was performed because of alumina inlay failure in 4hips(2 fractures and 2 dissociation;5.1%), loosening in 2 hips(2 cup loosenings; 2.5%) recurrent dislocation in 1 hip, and femoral fracture in 1 hip, no deep infection and DVT. The 10-year survival rate was 92.4% with revision for any reason and 95.9% with revision for alumina failure as the end point. We detected 3 ceramic failures at a mean of 8.9 years(4.1ï¼ï¿½12.5) after the index operation. There were no differences in BMI, function, cup angles(inclination and anteversion), and cup loosening among the 4hips with alumina failure. But there were differences in age, gender, and activity with alumina failure. This alumina on alumina THA yielded passably mid-term results, but it was occurred a high rate of catastrophic alumina inlay failure. In July 2000, we discontinued use of this type of THA to avoid alumina failure. This ABS cup was banned in 2002, because of numerous alumina failures. We suggest all patients with this type of acetabular component be followed carefully. Cemented polyethylene-backed alumina-on-alumina THA with a composite of alumina inlay had a relatively high rate of catastrophic alumina inlay failure(5.1ï¼ï¿½) during a mean of 13.8 years' follow up. There were differences in age, gender, and activity with alumina failure


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_1 | Pages 44 - 44
1 Feb 2015
Pagnano M
Full Access

Mini-posterior technique advantages: Familiar anatomy; Widely applicable; Predictable (and thus preventable) sources of errors; Demonstrated functional advantages over the 2-incision THA in recent prospective randomised trials and in direct comparison studies. Familiar anatomy: A substantial number of surgeons routinely use the posterior approach; With careful attention to skin incision placement and leg positioning intraoperatively it is relatively easy for most surgeons to shorten the skin incision; With the addition of specialised retractors, offset reamers and offset cup and stem inserters many THA can be done with a skin incision of 10cm or less; Easily converted to standard posterior approach if intraoperative concerns arise; Formal posterior capsular repair substantially lowers historical risk of dislocation. Widely applicable: With relatively little variation this approach can be used for a broad range of THA patients; Several variations of the mini-posterior technique exist (Sculco, Dorr, Swanson, Goldstein); Dorr technique has been used in my practice and we have studied it extensively in direct comparison studies against the 2-incision technique


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_22 | Pages 23 - 23
1 Dec 2016
Lee G
Full Access

While total hip arthroplasty (THA) has been shown successful at relieving pain and improving function in patients with coxarthrosis, wear and instability remain leading causes for revision surgery. Highly crosslinked polyethylene (HXPE) has significantly reduced wear and osteolysis but volumetric wear associated with the use of larger diameter ball heads may be an issue in the long-term. Finally, concerns with femoral taper corrosion have increased the utilization of ceramic ball heads in recent years. Ceramic on ceramic articulations are optimised for both minimizing implant wear and instability. It is biocompatible, wettable, and possesses the lowest in vitro and in vivo wear rates among all bearing couples. In fact, wear rates are lowest when the ceramic ball head size is maximised. Additionally, modern ceramic on ceramic THA designs have had an excellent clinical track record with low rates of loosening, failure, and no reports of osteolysis in even highly active, young patients. Concerns with ceramics center around issues related to fracture risk, squeaking, and cost. While the phenomenon of squeaking remains poorly understood, the reliability of ceramic implants have steadily improved with better materials, design, and manufacturing. The fracture risk for modern pure alumina implants and the newer alumina matrix composite ceramics are 1 in 5000 and 1 in 100,000, respectively. The advantages of ceramic on ceramic THAs will not be realised on every patient and therefore, should be selectively used. However, with expected increases in life expectancy and more young, active patients undergoing THA, ceramic on ceramic THA should be strongly considered in patients under age 60 years