header advert
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 49 - 49
1 Jan 2016
Hsiao C Tsai Y Yu S Tu Y
Full Access

Introduction

Locking plates can provide greater stability than conventional plates; however, reports revealed that fractures had a high incidence of failure without medial column support; the mechanical support of medial column could play a significant role in humeral fractures. Recent studies have demonstrated the importance of intramedullary strut in proximal humeral fracture fixation, the relationship to mechanical stability and supporting position of the strut remain unclear. The purpose of this study was to evaluate the influence of position of the intramedullary strut on the stability of proximal humeral fractures using a locking plate.

Materials and methods

Ten humeral sawbone (Synbone) and locked plates (Synthes, cloverleaf plate), with and without augmented intramedullary strut (five in each group) for proximal humerus fractures, were tested using material testing machine to validate the finite element model. A 10 mm osteotomy was performed at surgical neck and a strut graft (10 cm in length) was inserted into the fracture region to lift the head superiorly. Each specimen was statically tested at a rate of 5 mm/min until failure. To build the finite element (FE) model, 64-slices CT images were converted to create a 3D solid model. The material properties of screws and plates were modeled as isotropic and linear elastic, with an elastic modulus of 110 GPa, (Poisson's ratio, n=0.3). The Young's moduli of cortical and cancellous bones were 17 GPa and 500 MPa (n=0.4), respectively. Three alter shifting toward far cortex by 1, 2, and 3 mm in humeral canal were installed in the simulating model.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 50 - 50
1 Jan 2016
Hsiao C Tsai Y Yang T Hsu C Tu Y
Full Access

Introduction

Distal femur fracture is a critical issue in orthopedic trauma, because it is difficult to manage especially in cases with intra-articular fracture. Osteoporosis may cause instability of implant and increase complications. Few studies investigate on the stability of distal femur osteoporotic fracture and the behaviors under cycling. Our hypothesis was that the stiffness of construct would decrease as cycling in osteoporotic bone.

Materials and Methods

Seven cadaver specimens were used in this study. Relative bone density for each specimen was evaluated using CT scanning by three known calibration phantoms scanned simultaneously with the specimen. All cadaver specimens were divided normal (group 1) and osteoporosis (group 2) in accordance with the bone density. The titanium distal femur locking plates with 6 screws placed in distal femur condyle and 4 in shaft. A 10 mm gap with 65 mm proximal to the center of articular surface and a vertical fractural line between intra-articular were created to simulate AO C2 type fracture. Each specimen was cyclically loaded in two-phase at a frequency of 2 Hz. Phase 1 was set at 1000 N for 10000 cycles. In phase 2, the load was set at 2000 N for 10000 cycles. Then, the specimen was loaded up to failure at a rate of 5 mm/min. Stiffness was evaluated from the linear portion of load-displacement curve at 2000 cycle interval.