Vol. 106-B, Issue SUPP_16 | Pages 77 - 77
19 Aug 2024
Fu H Singh G H C Lam J Yan CH Cheung A Chan PK Chiu KY
Full Access

Hip precautions following total hip arthroplasty (THA) limits flexion, adduction and internal rotation, yet these precautions cause unnecessary psychological stress. This study aims to assess bony and implant impingement using virtual models from actual patient's bony morphology and spinopelvic parameters to deduce whether hip precautions are necessary with precise implant positioning in the Asian population.

Individualized sitting and standing sacral slope data of robotic THAs performed at two tertiary referral centers in Hong Kong was inputted into the simulation system based on patients’ pre-operative sitting and standing lumbar spine X-rays. Three-dimensional dynamic models were reconstructed using the Stryker Mako THA 4.0 software to assess bony and implant impingement both anteriorly and posteriorly, with default cup placement at 40° inclination and 20° anteversion. Femoral anteversion followed individual patient's native version. A 36mm hip ball was chosen for all cups equal or above 48mm and 32mm for those below. Anterior impingement was assessed by hip flexion and posterior impingement was assessed by hip extension.

113 patients were included. At neutral rotation and adduction, no patients had anterior implant impingement at hip flexion of 100°. 1.7% had impingement at 110°, 3.5% had impingement at 120°, 9.7% had impingement at 130°. With 20° of internal rotation and adduction, 0.8% had anterior implant impingement at hip flexion of 90°, 7.1% had impingement at 100° and 18.5% had impingement at 110°. With the hip externally rotated by 20°, 0.8% of patients had posterior implant impingement, and 8.8% bony impingement at 0° extension.

With enabling technology allowing accurate component positioning, hip precautions without limiting forward flexion in neutral position is safe given precise implant positioning and adequate osteophyte removal. Patients should only be cautioned about combined internal rotation, adduction with flexion.


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 917 - 923
1 Jul 2015
Singh G Nuechtern JV Meyer H Fiedler GM Awiszus F Junk-Jantsch S Bruegel M Pflueger G Lohmann CH

The peri-prosthetic tissue response to wear debris is complex and influenced by various factors including the size, area and number of particles. We hypothesised that the ‘biologically active area’ of all metal wear particles may predict the type of peri-prosthetic tissue response.

Peri-prosthetic tissue was sampled from 21 patients undergoing revision of a small diameter metal-on-metal (MoM) total hip arthroplasty (THA) for aseptic loosening. An enzymatic protocol was used for tissue digestion and scanning electron microscope was used to characterise particles. Equivalent circle diameters and particle areas were calculated. Histomorphometric analyses were performed on all tissue specimens. Aspirates of synovial fluid were collected for analysis of the cytokine profile analysis, and compared with a control group of patients undergoing primary THA (n = 11) and revision of a failed ceramic-on-polyethylene arthroplasty (n = 6).

The overall distribution of the size and area of the particles in both lymphocyte and non-lymphocyte-dominated responses were similar; however, the subgroup with lymphocyte-dominated peri-prosthetic tissue responses had a significantly larger total number of particles.

14 cytokines (interleukin (IL)-1ß, IL-2, IL-4, IL-5, IL-6, IL-10, IL-13, IL-17, interferon (IFN)-γ, and IFN-gamma-inducible protein 10), chemokines (macrophage inflammatory protein (MIP)-1α and MIP-1ß), and growth factors (granulocyte macrophage colony stimulating factor (GM-CSF) and platelet derived growth factor) were detected at significantly higher levels in patients with metal wear debris compared with the control group.

Significantly higher levels for IL-1ß, IL-5, IL-10 and GM-CSF were found in the subgroup of tissues from failed MoM THAs with a lymphocyte-dominated peri-prosthetic response compared with those without this response.

These results suggest that the ‘biologically active area’ predicts the type of peri-prosthetic tissue response. The cytokines IL-1ß, IL-5, IL-10, and GM-CSF are associated with lymphocyte-dominated tissue responses from failed small-diameter MoM THA.

Cite this article: Bone Joint J 2015;97-B:917–23.