Bone & Joint Research
Vol. 12, Issue 9 | Pages 590 - 597
20 Sep 2023
Uemura K Otake Y Takashima K Hamada H Imagama T Takao M Sakai T Sato Y Okada S Sugano N

Aims

This study aimed to develop and validate a fully automated system that quantifies proximal femoral bone mineral density (BMD) from CT images.

Methods

The study analyzed 978 pairs of hip CT and dual-energy X-ray absorptiometry (DXA) measurements of the proximal femur (DXA-BMD) collected from three institutions. From the CT images, the femur and a calibration phantom were automatically segmented using previously trained deep-learning models. The Hounsfield units of each voxel were converted into density (mg/cm3). Then, a deep-learning model trained by manual landmark selection of 315 cases was developed to select the landmarks at the proximal femur to rotate the CT volume to the neutral position. Finally, the CT volume of the femur was projected onto the coronal plane, and the areal BMD of the proximal femur (CT-aBMD) was quantified. CT-aBMD correlated to DXA-BMD, and a receiver operating characteristic (ROC) analysis quantified the accuracy in diagnosing osteoporosis.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 56 - 56
1 Mar 2017
Uemura K Takao M Otake Y Koyama K Yokota F Hamada H Sakai T Sato Y Sugano N
Full Access

Background

Cup anteversion and inclination are important to avoid implant impingement and dislocation in total hip arthroplasty (THA). However, it is well known that functional cup anteversion and cup inclination also change as the pelvic sagittal inclination (PSI) changes, and many reports have been made to investigate the PSI in supine and standing positions. However, the maximum numbers of subjects studied are around 150 due to the requirement of considerable manual input in measuring the PSIs. Therefore, PSI in supine and standing positions were measured fully automatically with a computational method in a large cohort, and the factors which relate to the PSI change from supine to standing were analyzed in this study.

Methods

A total of 422 patients who underwent THA from 2011 to 2015 were the subjects of this study. There were 83 patients with primary OA, 274 patients with DDH derived secondary OA (DDH-OA), 48 patients with osteonecrosis, and 17 patients with rapidly destructive coxopathy (RDC). The median age of the patient was 61 (range; 15–87). Preoperative PSI in supine and standing positions were measured and the number of cases in which PSI changed more than 10° posteriorly were calculated. PSI in supine was measured as the angle between the anterior pelvic plane (APP) and the horizontal line of the body on the sagittal plane of APP, and PSI in standing was measured as the angle between the APP and the line perpendicular to the horizontal surface on the sagittal plane of APP (Fig. 1). The value was set positive if the pelvis was tilted anteriorly and was set negative if the pelvis tilted posteriorly. Type of hip disease, sex, and age were analyzed with multiple logistic regression analysis if they were related to PSI change of more than 10°. For accuracy verification, PSI in supine and standing were measured manually with the previous manual method in 100 cases and were compared with the automated system used in this study.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 39 - 39
1 Mar 2017
Takao M Ogawa T Yokota F Otake Y Hamada H Sakai T Sato Y Sugano N
Full Access

Introduction

Patients with hip osteoarthritis have a substantial loss of muscular strength in the affected limb compared to the healthy limb preoperatively, but there is very little quantitative information available on preoperative muscle atrophy and degeneration and their influence on postoperative quality of life (QOL) and the risk of falls. The purpose of the present study were two folds; to assess muscle atrophy and degeneration of pelvis and thigh of patients with unilateral hip osteoarthritis using computed tomography (CT) and to evaluate their impacts on postoperative QOL and the risk of falls.

Methods

We used preoperative CT data of 20 patients who underwent primary total hip arthroplasty. The following 17 muscles were segmented with our developed semi-automated segmentation method: iliacus, gluteus maximus, gluteus medius, gluteus minimus, rectus femoris, tensor facia lata, adductors, pectinus, piriformis, obturator externus, obturator internus, semimenbranosus, semitendinosus, vastus medialis and vastus lateralis/intermedius (Fig. 1). Volume and radiological density of each muscle were measured. The ratio of those of affected limb to healthy limb was calculated. At the latest follow-up, the WOMAC score was collected and a history of falls after surgery was asked. The average follow- up period was 6 years.

Comparison of the volume and radiological density of each muscle between affected and healthy limbs was performed using the Wilcoxon signed rank test. Correlations between the volume and radiological density of each muscle and each score of the WOMAC were evaluated with Spearman's correlation coefficient. The volume and radiological density of each muscle between patients with and without a history of falls were compared using Mann-Whitney U test.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_5 | Pages 55 - 55
1 Feb 2016
Grupp R Otake Y Murphy R Parvizi J Armand M Taylor R
Full Access

Computer-aided surgical systems commonly use preoperative CT scans when performing pelvic osteotomies for intraoperative navigation. These systems have the potential to improve the safety and accuracy of pelvic osteotomies, however, exposing the patient to radiation is a significant drawback. In order to reduce radiation exposure, we propose a new smooth extrapolation method leveraging a partial pelvis CT and a statistical shape model (SSM) of the full pelvis in order to estimate a patient's complete pelvis. A SSM of normal, complete, female pelvis anatomy was created and evaluated from 42 subjects. A leave-one-out test was performed to characterise the inherent generalisation capability of the SSM. An additional leave-one-out test was conducted to measure performance of the smooth extrapolation method and an existing “cut-and-paste” extrapolation method. Unknown anatomy was simulated by keeping the axial slices of the patient's acetabulum intact and varying the amount of the superior iliac crest retained; from 0% to 15% of the total pelvis extent. The smooth technique showed an average improvement over the cut-and-paste method of 1.31 mm and 3.61 mm, in RMS and maximum surface error, respectively. With 5% of the iliac crest retained, the smoothly estimated surface had an RMS surface error of 2.21 mm, an improvement of 1.25 mm when retaining none of the iliac crest. This anatomical estimation method creates the possibility of a patient and surgeon benefiting from the use of a CAS system and simultaneously reducing the patient's radiation exposure.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_28 | Pages 84 - 84
1 Aug 2013
Murphy R Otake Y Lepistö J Armand M
Full Access

Introduction

The goal of this work is to develop a system for three-dimensional tracking of the acetabular fragment during periacetabular osteotomy (PAO) using x-ray images. For PAO, the proposed x-ray image-based navigation provides geometrical and biomechanical assessment of the acetabular fragment, which is unavailable in the conventional procedure, without disrupting surgical workflow or requiring tracking devices.

Methods

The proposed system combines preoperative planning with intraoperative tracking and near real-time automated assessment of the fragment geometry (radiographic angles) and biomechanics (contact pressure distribution over the acetabular surface). During PAO, eight fiducial beads are attached to the patient after incision and prior to performing osteotomy. Four of the beads attach to the iliac wing above the expected superior osteotomy (these are termed confidence points), and four attach on the expected fragment (denoted fragment points).

At least two x-ray images are obtained before and after osteotomy. In each set of images, image processing routines segment the fiducials and triangulate the 2D fiducial projections in 3D space. A paired-point registration between the confidence points triangulated from the two x-ray image sets aligns the imaging frames. We measured the transformation between the fragment points with respect to the confidence points to quantify the motion of the acetabular fragment. Applying an image-based 2D-3D registration to the measured acetabular transformation localises the reoriented acetabular fragment with respect to an anatomical coordinate system. We present the surgeon with visualisation and automatic estimations of radiographic angles and biomechanics of the reoriented acetabular fragment.

We conducted an experiment to evaluate feasibility and accuracy of the proposed system using a high density pelvic sawbone. Stainless steel beads were glued to the sawbone as fiducials. X-ray images were selected from cone-beam CT (CBCT) scans with an encoded motorised C-arm. Fiducial segmentation from reconstructed volumes of the CBCT scans provided a ground truth for the experiment.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIV | Pages 12 - 12
1 Oct 2012
Kang X Yau W Otake Y Taylor R
Full Access

Anterior Cruciate Ligament (ACL) rupture is one of the commonest injuries in sports medicine. However, the rates of the reported graft re-rupture range from 2–10%, leading to around 3000 to 10000 revision ACL reconstructions in United States per annum. Inaccurate tunnel positions are considered to be one of the commonest reasons leading to failure and subsequent revision surgery. Additionally, there remains no consensus of the optimal position for ACL reconstructions.

The positions of the bone tunnels in patients receiving ACL reconstruction are traditionally assessed using X-rays. It is well known that conventional X-ray is not a precise tool in assessing tunnel positions. Thus, there is a recent trend in using three-dimensional (3D) CT. However, routine CT carries a major disadvantage in terms of significant radiation hazard. In addition, it is both inconvenient and expensive to use CT as a regular assessment tools during the follow-up.

The goal of the present work is to develop a novel 2D-3D registration method using single X-ray image and a surface model. By performing such registration for two post-operative X-rays, we can further calculate the 3D tunnel positions after ACL reconstructions. Our framework consists of five parts: (1) a surface model of the knee, (2) a 2D-3D registration algorithm, (3) a 3D tunnel position calculation, (4) a graphic user interface (GUI), and (5) a semi-transparency rendering. Among them, the crucial part is our 2D-3D registration method that estimates the relative position of the knee model in the imaging coordinate system. Once registered, the 3D position of an ACL tunnel in the knee model is calculated from the imaging geometry. The only interaction required is to mark the ACL tunnels on the X-rays through the GUI.

We propose two 2D-3D registration methods. One is a contour-based method that uses pure geometric information. Most methods in this category accomplish the registration by extracting contours in X-rays, establishing their correspondences on the 3D model, and calculating the registration parameters. Unlike these methods, which need point-to-point correspondences, our method optimises the registration parameters in a statistical inference framework without giving or establishing point-to-point correspondences. Due to the use of the statistical inference, our method is robust to the spurs and broken contours that automatically extracted by the contour detector.

The second method takes into account both the geometric shape of the object and the intensity property (intensity changes) of the image, where the intensity changes can be detected via image gradients. The use of gradient is based on the interpretation that two images are considered similar, if intensity changes occur at the same locations. The angles between the image gradients and the projected surface normals were used as a distance measure. The summation of the measures for all projected model points gives us the gradient term, which we multiply the contour-based measurement. Multiplication is preferred over addition because addition of the terms would require both terms to be normalised.

To evaluate the feasibility of our methods, a simulation study was conducted using Digitally Reconstructed Radiographs (DRR) of a sawbone underwent a single-bundle ACL reconstruction performed by an experienced orthopedic surgeon. The real position of the bone tunnel entry point was obtained using the CT images, which were acquired using a custom-made well-calibrated cone-beam CT. The knee model was built by downsampling and smoothing the high-resolution CT reconstructions. It is important in our experiments to make the model different from the original reconstruction since this simulates the condition in which patient's CT is unavailable. Two DRRs generated from approximately anteroposterior and lateral viewpoints were used. For each DRR, 50 trials of 2D-3D registration were carried out for the femoral part using 50 different initialisations, which were randomly selected from the values independently and uniformly distributed within ±10 degrees and ±10 mm of the ground-truth.

Compared with the ground-truth established using the CT images, our single image contour-based method achieved accurate estimations in rotations and in-plane translations, which were (−0.67±1.38, −0.98±0.84, −0.42±0.71) degrees and (0.11±0.26, −0.06±1.20) mm for the anteroposterior image, and (−0.78±0.76, −0.37±0.87, 0.70±0.88) degrees and (−0.14±0.22, 0.31±0.71) mm for the lateral one, respectively. The same experiments were also performed using the second method. However, it did not produce desirable results in our experiments. The tunnel entry point was then calculated using the averaged registration result of our contour-based method. The entry point of the tunnel was obtained with high accuracy of 1.25 mm distance error from the real position of the entry point.

For the 2D-3D registration, the estimated off-plane translations showed relatively low accuracy. It is well known that the depth can be difficult to be accurately estimated using one single image. As the result showed, the accuracy in rotations and in-plane translations is more important for ACL tunnel position estimation in our framework. As for the image gradient, it is too sensitive to the small perturbation caused by image noises. A more robust way of integrating the gradient information into our contour-based method is required. We propose a novel approach for estimating the 3D position of bone tunnels in ACL reconstruction using two post-operative X-rays. It was tested in a sawbone study using DRRs. The most significant advantage of our approach is to potentially eliminate the necessity of acquiring a patient's CT. The success in developing and validating the proposed workflow will allow convenient and precise assessment of tunnel positions in ACL reconstruction with minimal risk of radiation hazard.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 170 - 170
1 Mar 2008
Aikawa K Sugano N Miki H Hagio K Nakamura N Otake Y Hattori A Suzuki N Yoshikawa H
Full Access

While numerous studies have examined dislocation caused by basic everyday movements, no objective studies have investigated body positions to minimize risk of dislocation during intercourse. We therefore used a four-dimensional motion analysis system to assess sexual activities in patients who had undergone total hip arthroplasty (THA), to identify body positions displaying less risk of dislocation.

Five body-surface infrared sensors were placed on five healthy female volunteers, and maximum hip joint angle was measured. Subjects were asked to take the following three body positions: supine (missionary); top (woman on top); and kneeling (doggy-style). Angle data obtained using body surface markers were combined with three-dimensional skeletal models extracted using CT images obtained from the 24 joints of 16 patients who had undergone THA, to ascertain angles at which collision with the artificial joint or skeleton would occur.

Collision angle for: supine position at maximum abduction in flexion was 77±16° in flexion and 82±57° in medial rotation; top position at maximum extension was 36±16° in flexion and 68±53° in medial rotation; top position at maximum flexion was 12±9° in flexion and 14±11° in medial rotation; kneeling position at maximum extension was 115±1° in flexion and 127±44° in medial rotation; and kneeling position at maximum flex-ion was 14±8° in flexion and 17±11° in medial rotation.

The present study only assessed risk for dislocation caused by collision with the artificial joint or skeleton, and did not take into account the effects of soft tissue. However, we were able to quantitatively assess angle of the hip joint for some leg positions involved with various common coital positions. The results showed that the supine position at maximum abduction in flexion is relatively safe, since the range of motion before collision would occur was relatively wide. In addition, top and kneeling positions at maximum extension were relatively safe, but caution must be exercised at maximum flexion, as not much extra angle was available in flexion and medial rotation.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 170 - 170
1 Mar 2008
Hagio K Sugano N Nishii T Miki H Otake Y Hattori A Suzuki N Yonenobu K Yoshikawa H Ochi T
Full Access

We have developed a novel system of 4-dimensional motion analysis after total hip arthroplasty (THA) that can aid in preventing dislocation by assessing safe range of motion for patients in several daily activities.

This system uses skeletal structure data from CT and motion capture data from an infrared position sensor. A 3-D model reconstructed from CT data is combined with the motion capture data. Using this system, we analyzed hip motion when getting up from and sitting down in a chair or picking up an object while sitting in a chair in 17 patients (26 hips) who underwent THA. To assess the accuracy of this system’s measurements, open MRI was used to evaluate positions of skin markers against bones in 5 healthy volunteers in various postures.

No impingement between bones and/or implants was found in any subjects during any activities. However, mean angle at the point of maximum hip flexion was different for each patient. The open MRI results indicated that average error in hip angle of the present system was within 5 degrees for each static posture.

The functional position of the pelvis during daily activities must be taken into account when assessing the real risk of dislocation. The present system enables dynamic analysis involving not only alignment of components and bones of each patient, but also individual differences in characteristics of daily motions. Further investigation using this system can help determine safe ranges of motion for preventing hip dislocation, improving the accuracy of individualized guidance for patients regarding postoperative activities.