header advert
Results 1 - 7 of 7
Results per page:
Applied filters
Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 10 - 10
2 Jan 2024
Martínez T Mariscal G Hevia E Barrios C
Full Access

The multimodal management of canal stenosis is increasing, and inhibitors of central sensitization are playing a crucial role in central sensitization processes. Pregabalin and gabapentin are antiepileptic drugs that reduce presynaptic excitability. The objective of this study was to investigate whether the use of pregabalin and gabapentin is effective in the symptomatic management of canal stenosis.

A literature search was conducted in four databases. The inclusion criteria were studies that compared pregabalin or gabapentin with a control group in lumbar canal stenosis. Randomized clinical trials and a comparative retrospective cohort study were included. The main clinical endpoints were VAS/NRS, ODI, and RDQ (Roland Morris Disability Questionnaire) at 2, 4, 8 weeks, and 3 months, adverse events, and walking distance were also collected. Data were combined using Review Manager 5.4 software.

Six studies and 392 patients were included. The mean age was 60.25. No significant differences were observed in VAS at 2, 4, and 8 weeks: (MD: 0.23; 95% CI: −0.63-1.09), (MD: −0.04; 95% CI: −0.64 to −0.57), and (MD: −0.6; 95% CI: −1.22 to 0.02). Significant differences were observed in favor of pregabalin with respect to VAS at three months: (MD: −2.97; 95% CI: −3.43 to −2.51). No significant differences were observed in ODI (MD: −3.47; 95% CI: −7.15 to −0.21). Adverse events were significantly higher in the pregabalin/gabapentin group (OR 5.88, 95%CI 1.28-27.05). Walking distance and RDQ could not be compared, although the results were controversial.

Gabapentinoids have not been shown to be superior to other drugs used in the treatment of LSS or to placebo. However, they have shown a higher incidence of adverse effects, improved results in VAS at 3 months, and a slight improvement in ambulation at 4 months in combination with NSAIDs compared to NSAIDs in monotherapy.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 2 - 2
2 Jan 2024
Mariscal G Burgos J Antón-Rodrigálvarez L Hevia E Barrios C
Full Access

In healthy subjects, respiratory maximal volumes are highly dependent on the sagittal range of motion of the T7-T10 segment. In AIS, the abolition of T7-T10 dynamics related to the stiffness induced by the apex region in Lenke IA curves could harm ventilation during maximal breathing. The aim of this study was to analyze the dynamics of the thoracic spine during deep breathing in AIS patients and in healthy matched controls. This is a cross-sectional, case-control study. 20 AIS patients (18 girls, Cobb angle, 54.7±7.9°; Risser 1.35±1.2) and 15 healthy volunteers (11 girls) matched in age (12.5 versus 15.8 yr. mean age) were included. In AIS curves, the apex was located at T8 (14) and T9 (6). Conventional sagittal radiographs of the whole spine were performed at maximal inspiration and exhalation. The ROM of each spinal thoracic functional segment (T1-T7, T7-T10, T10-T12) and the global T1-T12 ROM were measured. In healthy subjects, the mean T1-T12 ROM during forced breathing was 16.7±3.8. AIS patients showed a T1-T12 ROM of 1.1±1.5 (p<0.05), indicating a sagittal stiffness of the thoracic spine. A wide T7-T10 ROM (15.3±3.0) was found in healthy controls (91.6% of the T1–T12 ROM). AIS patients showed only 0.4±1.4 ROM at T7-T10 (36.4% of the T1-T12 ROM) (p<0.001). There was a significant positive correlation between the magnitude of T7-T10 kyphosis in maximal exhalation and both FVC (% of predicted FVC) and FEV1. In conclusion, Lenke 1A AIS patients show a restriction of the thoracic spine motion with an almost complete abolition of T7-T10 ROM, a crucial segment for deep breathing. T7-T10 stiffness could explain the ventilatory limitations found in AIS patients.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 24 - 24
2 Jan 2024
Burgos J Mariscal G Antón-Rodrigálvarez L Sanpera I Hevia E García V Barrios C
Full Access

The aim of this study was to report the restauration of the normal vertebral morphology and the absence of curve progression after removal the instrumentation in AIS patients that underwent posterior correction of the deformity by common all screws construct whitout fusion. A series of 36 AIS immature patients (Risser 3 or less) were include in the study. Instrumentation was removed once the maturity stage was complete (Risser 5). Curve correction was assessed at pre and postoperative, before instrumentation removal, just post removal, and more than two years after instrumentation removal. Epiphyseal vertebral growth modulation was assessed by a coronal wedging ratio (WR) at the apical level of the main curve (MC). The mean preoperative coronal Cobb was corrected from 53.7°±7.5 to 5.5º±7.5º (89.7%) at the immediate postop. After implants removal (31.0±5.8 months) the MC was 13.1º. T5–T12 kyphosis showed a significant improvement from 19.0º before curve correction to 27.1º after implants removal (p<0.05). Before surgery, WR was 0.71±0.06, and after removal WR was 0.98±0.08 (p<0.001). At the end of follow-up, the mean sagittal range of motion (ROM) of the T12-S1 segment was 51.2±21.0º. SRS-22 scores improved from 3.31±0.25 preoperatively to 3.68±0.25 at final assessment (p<0.001). In conclusion, fusionless posterior approach using a common all pedicle screws construct correct satisfactory scoliotic main curves and permits removal of the instrumentation once the bone maturity is reached. The final correction was highly satisfactory and an acceptable ROM of the previously lower instrumented segments was observed.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 145 - 145
11 Apr 2023
Mariscal G Jover N Balfagón A Barrés M
Full Access

Solid organ transplant (SOT) recipients present an increased medical risk; however, few studies analyze the outcomes of these patients undergoing hip fracture surgery. This study aimes to determine the incidence of hip fracture in SOT patients and to compare the outcomes of SOT patients with matched non-SOT controls after hip fracture fixation.

A retrospective review identified 20 SOT patients with hip fracture at a single center from 2016 to 2021 and were matched (1:1) with a cohort of 20 patients with hip fracture without SOT. Patient outcomes, mortality/survival and clinical outcomes were compared between two groups.

The incidence of hip fracture in SOT patients was 20/1787, 1.1%. There were significant differences in mortality rate (73.3% SOT group vs. 26.7% non-SOT group; p<0.05). There were no differences in survival time (p=0.746). There were no differences in time to surgery (5.0 days SOT group vs. 3.1 days non-SOT group; p=0.109), however, there were significant differences in the hospital length of stay (14 days SOT group vs. 8.6 days non-SOT group; p=0.018). There were no differences regarding the complication rate between the two groups (9/20, 45% vs. 6/20, 30% in the SOT and non-SOT groups, respectively).

SOT patients with associated hip fracture required longer hospital length of stay than non-SOT patients. SOT patients did not show greater clinical complications; however, they presented higher mortality rate compared to non-SOT patients.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 121 - 121
11 Apr 2023
Mariscal G Burgos J Antón-Rodrigálvarez L Hevia E Barrios C
Full Access

To analyze the dynamics of the thoracic spine during deep breathing in AIS patients and in healthy matched controls.

Case-control cross-sectional study. 20 AIS patients (18 girls, Cobb angle, 54.7±7.9°; Risser 1.35±1.2) and 15 healthy volunteers (11 girls) matched in age (12.5 versus 15.8 yr. mean age) were included. In AIS curves, the apex was located in T8 (14) and T9 (6). Conventional sagittal radiographs of the whole spine were performed at maximal inspiration and expiration. The ROM of each spinal thoracic functional segment (T1-T7, T7-T10, T10-T12), the global T1–T12 ROM were measured. Respiratory function was assess by forced vital capacity (FVC), expiratory volume (FEV1), FEV1/FVC, inspiratory vital capacity (IVC) and peak expiratory flow (PEF).

In healthy subjects, the mean T1–T12 ROM during forced breathing was 16.7±3.8. AIS patients showed a T1-T12 ROM of 1.1±1.5 (p<0.05) indicating a sagittal stiffness of thoracic spine. A wide T7–T10 ROM (15.3±3.0) was found in healthy controls (91.6% of the T1–T12 ROM). AIS patients showed only 0.4±1.4 ROM at T7-T10 (36.4% of the T1–T12 ROM) (p<0.001). There was a significant correlation between T7-T10 ROM and IVC.

Lenke 1A AIS patients show a restriction of the thoracic spine motion with an almost complete abolition of T7-T10 ROM, a crucial segment participating in the deep breathing. T7-T10 stiffness could explain the ventilatory limitations found in AIS patients.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 74 - 74
4 Apr 2023
Mariscal G Barrés M Barrios C Tintó M Baixauli F
Full Access

To conduct a meta-analysis for intertrochanteric hip fractures comparing in terms of efficacy and safety short versus long intralomedullary nails.

A pubmed search of the last 10 years for intertrochanteric fracture 31A1-31A3 according to the AO/OTA classification was performed. Baseline characteristics of each article were obtained, complication measures were analyzed: Peri-implant fracture, reoperations, deep/superficial infection, and mortality. Clinical variables consisted of blood loss (mL), length of stay (days), time of surgery (min) and nº of transfusions. Functional outcomes were also recorded. A meta-analysis was performed with Review Manager 5.4.

Twelve studies were included, nine were retrospective. The reoperations rate was lower in the short nail group and the peri-implant fracture rate was lower in the long nail group (OR 0.58, 95% CI 0.38 to 0.88) (OR 1.88, 95% CI 1.04 to 3.43). Surgery time and blood loss was significantly higher in the long nail group (MD −12.44, 95% CI −14.60 to −10.28) (MD −19.36, 95% CI −27.24 to −11.48). There were no differences in functional outcomes.

The short intramedullary nail has a higher risk of peri-implant fracture; however, the reoperation rate is lower compared to the long nail. Blood loss and surgery time was higher in the long nail group.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 124 - 124
1 Nov 2021
Mariscal G Camarena JN Galvañ T Barrios C Fernández P
Full Access

Introduction and Objective

The treatment of severe deformities often requiring aggressive techniques such as vertebral resection and osteotomies with high comorbidity. To mitigate this risk, several methods have been used to achieve a partial reduction of stiff curves. The objective of this study was to evaluate and quantify the effectiveness of the Perioperative Halo-Gravity Traction (HGT) in the Treatment of Severe Spinal Deformity in Children.

Materials and Methods

A historical cohort of consecutive childs with severe spinal deformity who underwent to a perioperative HGT as a part of the treatment protocol. Minimum follow-up of 2 years. Demographic, clinical and radiological data, including time duration of perioperative HGT and Cobb angle in the coronal and sagittal plane. The radiological variables were measured before the placement of the halo, after placement of the halo, at the end of the period of traction, after surgery and in the final follow-up.