Objective

By retrospective analysis of clinical data, to find new risk factors for postoperative dislocation after total hip replacement and the dose-effect relationship when multiple factors work simultaneously.

Methods

A nested case-control study was used to collect the dislocated hips from 5513 primary hip replacement case from 2000 to 2012. Apart from the patients with given cause of dislocation, 39 dislocated hips from 38 cases were compared with 78 hip from 78 cases free from dislocation postoperatively, which matched by the admission time. The factors that may affect the prosthetic unstable was found by the univariate analysis, and then they were performed multivariate logistic regression analysis and evaluation of a dose-effect factors.