header advert
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_12 | Pages 22 - 22
1 Mar 2013
Jordan C Quaye M Madi K Hsu Y Tong J Cossey A
Full Access

The treatment of acute full thickness chondral damage within the knee is a surgical challenge. Frequently used surgical techniques include chondroplasty, micro-fracture and chondrocyte implantation. These procedures give unpredictable functional outcomes and if the formation of neocartilage is achieved it is predominantly composed of type 1 collagen.

The TruFit osteochondral plug was designed to provide a scaffold for cell proliferation into full thickness chondral defects. It is a composite polymer composed of polylactide co-glycolide, calcium sulphate and poly-glycolide fibres. It is composed of 2 layers, one with a similar trabecular network to cancellous bone and a superficial layer designed to simulate articular lining.

The TruFit bone plug was analysed using micro-computed tomography. Its morphology characteristics, granulometry, mechanical performance and image guided failure were tested as well as numerical modelling to assess the permeability of TruFit.

Morphological parameters of the TruFit bone plug compared favourably with those of human tissue. Under load the scaffold exhibited shear bands throughout the composite leading to a failure mechanism similar to cancellous bone. Stress relaxation rates of the scaffolds were greatly decreased under wet conditions, likely due to plasticisation of the scaffold by water.

The biomechanical properties of the TruFit bone plugs are a cause for concern. The Scaffolds mechanical performance under load rapidly deteriorates in wet conditions at body temperature (the natural knee environment). This early failure will lead to defects in the articular surface where the plug has been inserted. Clinical data is sparse. This study correlates with work performed by Dockery et al & Spalding et al. These clinical studies have shown that the TruFit implant shows no evidence of bone ingrowth or osteoconductivity. It provides no subchondral support to neocartilage or tissue that was stimulated to form around the defects and surgical sites.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 10 | Pages 1397 - 1402
1 Oct 2010
Nada AN Debnath UK Robinson DA Jordan C

We describe the clinical outcome of a technique of surgical augmentation of chronic massive tears of the rotator cuff using a polyester ligament (Dacron) in 21 symptomatic patients (14 men, seven women) with a mean age of 66.5 years (55.0 to 85.0). All patients had MRI and arthroscopic evidence of chronic massive tears. The clinical outcome was assessed using the Constant and Murley and patient satisfaction scores at a mean follow-up of 36 months (30 to 46).

The polyester ligament (500 mm × 10 mm) was passed into the joint via the portal of Neviaser, medial to the tear through healthy cuff. The two ends of the ligament holding the cuff were passed through tunnels made in the proximal humerus at the footprint of the insertion of the cuff. The ligament was tied with a triple knot over the humeral cortex.

All the patients remained free from pain (p < 0.001) with improvement in function (p < 0.001) and range of movement (p < 0.001). The mean pre-operative and post-operative Constant scores were 46.7 (39.0 to 61.0) and 85.4 (52.0 to 96.0), respectively (p < 0.001). The mean patient satisfaction score was 90%. There were two failures, one due to a ruptured ligament after one year and the other due to deep-seated infection. The MR scan at the final follow-up confirmed intact and thickened bands in 15 of 17 patients.

This technique of augmentation gives consistent relief from pain with improved shoulder movement in patients with symptomatic massive tears of the rotator cuff.