header advert
Results 1 - 7 of 7
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 27 - 27
1 Jul 2012
White SP Forster MC Joshy S
Full Access

Background

Dual compartment knee replacement has been introduced to allow sparing of the cruciate ligaments and lateral compartment and preserve some biomechanics of knee function.

Aim

To study the early clinical and radiographic results of this new prosthesis.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 49 - 49
1 Jul 2012
Goodson MW Rath NK White SP John A Forster MC
Full Access

NICE guidelines state patients undergoing elective TKR receive post-operative chemical prophylaxis unless contraindicated, following guideline implementation our aim was to determine VTE incidence and wound complication outcomes related to administration of Rivaroxaban or Enoxaparin.

From April to October 2010 we prospectively studied 294 patients having primary or revision TKR. Each received either Rivaroxoban (n=219), Enoxaparin (n=68), UHF 5000 units (n=4) or no thromboprohylaxis (n=3) post-operatively. Primary outcome was identification of symptomatic post-operative VTE incidence and compared incidence over the same period in 2009 when aspirin was the standard chemical prophylaxis for VTE. Secondary outcomes were prolonged wound oozing rates and wound washout.

VTE occurred in 3 of 219 patients (2 PE, 1 DVT) receiving Rivaroxaban, and 1 PE in a patient who did not receive any thromboprophylaxis. No patients prescribed Enoxaparin developed VTE. In the same period 2009 there were 21 confirmed PEs in 512 patients undergoing TKR. This was statistically significant (Chi squared test p=0.02).

Prolonged oozing was noted in 3 patients receiving Enoxaparin, and 17 patients receiving Rivaroxaban. 6 patients treated with Rivaroxaban returned to theatre, 3 for continuous ooze, 2 for wound dehiscence and 1 for infection. During the same period in 2009, there was only 1 return to theatre for haematoma washout. (Chi squared test; p=0.02).

Following the NICE guidelines, there is a reduction in the PE rate following TKR but there is an increase in the overall return to theatre rate.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 4 | Pages 510 - 516
1 Apr 2012
Hickey BA Kempshall PJ Metcalfe AJ Forster MC

As part of the national initiative to reduce waiting times for joint replacement surgery in Wales, the Cardiff and Vale NHS Trust referred 224 patients to the NHS Treatment Centre in Weston-Super-Mare for total knee replacement (TKR). A total of 258 Kinemax TKRs were performed between November 2004 and August 2006. Of these, a total of 199 patients (232 TKRs, 90%) have been followed up for five years. This cohort was compared with 258 consecutive TKRs in 250 patients, performed at Cardiff and Vale Orthopaedic Centre (CAVOC) over a similar time period. The five year cumulative survival rate was 80.6% (95% confidence interval (CI) 74.0 to 86.0) in the Weston-Super-Mare cohort and 95.0% (95% CI 90.2 to 98.2) in the CAVOC cohort with revision for any reason as the endpoint. The relative risk for revision at Weston-Super-Mare compared with CAVOC was 3.88 (p < 0.001). For implants surviving five years, the mean Oxford knee scores (OKS) and mean EuroQol (EQ-5D) scores were similar (OKS: Weston-Super-Mare 29 (2 to 47) vs CAVOC 29.8 (3 to 48), p = 0.61; EQ-5D: Weston-Super-Mare 0.53 (-0.38 to 1.00) vs CAVOC 0.55 (-0.32 to 1.00), p = 0.79). Patients with revised TKRs had significantly lower Oxford knee and EQ-5D scores (p < 0.001).

The results show a higher revision rate for patients operated at Weston-Super-Mare Treatment Centre, with a reduction in functional outcome and quality of life after revision. This further confirms that patients moved from one area to another for joint replacement surgery fare poorly.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 15 - 15
1 Mar 2012
Verghese N Joshy S Cronin M Forster MC Robertson A
Full Access

Recently biodegradable synthetic scaffolds (Trufit plug) have provided novel approach to the management of chondral and osteochondral lesions. The aim of this study was to assess our 2 year experience with the Trufit plug system.

22 patients aged 20 to 50 years old all presenting with knee pain over a 2 year period were diagnosed either by MRI or arthroscopically with an isolated chondral or osteochondral lesion and proceeded to either arthroscopic or mini arthrotomy Trufit plug implantation. In 5 patients plug implantation was undertaken along with ACL reconstruction (3), medial meniscal repair (1) and contralateral knee OCD screw fixation (1). Pre and post operative IKDC scores were obtained to assess change in knee symptoms and function.

At a mean follow up of 15 months (range 2 – 24 months) improved IKDC scores were achieved with the scores improving with time. 2 patients have had a poor result and have had further surgery for their chondral lesions. One patient had failure of graft incorporation at second look arthroscopy and went onto to have a good result after ACI. The second patient had good graft incorporation on second look but had progression of osteoarthritic degeneration throughout the other compartments of the knee which were not initially identified at the time of Trufit plugging.

We conclude that Trufit plug is an alternative method for managing isolated chondral and osteochondral lesions of the knee which avoids harvest site morbidity or the need for staged surgery.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 80 - 80
1 Mar 2012
Joshy S Verghese N White SP Robertson A Forster MC
Full Access

Involvement of Patellofemoral joint (PFJ) has significant bearing in the management of osteoarthritis of the knee. The aim of this study is to assess the relationship between skyline radiographs, MRI and arthroscopic findings in the patellofemoral joint.

Data was collected prospectively from fifty-three patients who underwent arthroscopy. There were 36 males and 17 females in the group with mean age of 48 years (range 18-71). Arthroscopically PFJ arthritis was classified based on Outerbridge grading system. Patients with Outerbridge grade III and IV lesions were considered to have significant arthritis of the PFJ. Kellgren-Lawrence grading system was used to assess the skyline radiographs. Radiographically patients with grade III and IV Kelgren-Lawrence changes were considered to have significant osteoarthritis of the PFJ. MRI scans were also studied to assess involvement of PFJ. Thirty-two patients had MRI scan and 20 patients had skyline views done as part of preoperative work up. Arthroscopic findings were considered as gold standard.

MRI scan had specificity of 75%, sensitivity of 81%, positive predictive value of (PPV) 77 and negative predictive value of (NPV) 80% in diagnosing significant PFJ arthritis. Skyline radiographs had specificity of 100%, sensitivity of 50%, PPV of 100% and NPV of 57%. The overall accuracy of skyline radiographs in predicting significant PFJ arthritis was 70% and for MRI was 78%. We conclude that skyline radiographs has some value in he diagnosis of PFJ arthritis, however the sensitivity and negative predictive value is very is poor.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 7 | Pages 903 - 906
1 Jul 2009
Trickett RW Hodgson P Forster MC Robertson A

We aimed to determine the reliability, accuracy and the clinical role of digital templating in the pre-operative work-up for total knee replacement.

Initially a sample of ten pre-operative digital radiographs were templated by four independent observers to determine the inter- and intra-observer reliability of the process. Digital templating was then performed on the radiographs of 40 consecutive patients undergoing total knee replacement by a consultant surgeon not involved with the operation, who was blinded to the size of the implant inserted. The Press Fit Condylar Sigma Knee system was used in all the patients. The size of the implant as judged by templating was then compared to that of the size used.

Good inter- and intra-observer agreement was demonstrated for both femoral and tibial templating. However, the correct size of the implant was predicted in only 48% of the femoral and 55% of the tibial components. Albeit reproducible, digital templating does not currently predict the correct size of component often enough to be of clinical benefit.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1006 - 1010
1 Aug 2006
Forster MC Bauze AJ Bailie AG Falworth MS Oakeshott RD

The clinical results of bilateral total knee replacement staged at a one-week interval during a single hospital admission were compared with bilateral total knee replacements performed under the same anaesthetic and with bilateral total knee replacements performed during two separate admissions. The data were retrospectively reviewed. All operations had been performed by the same surgeon using the same design of prosthesis at a single institution.

The operative time and length of stay for the one-week staged group were comparable with those of the separate admission group but longer than for the patients treated under one anaesthetic. There was a low rate of complications and good clinical outcome in all groups at a mean follow-up of four years (1 to 7.2). The group staged at a one-week interval had the least blood loss (p = 0.004).

With appropriate patient selection, bilateral total knee replacement performed under a single anaesthetic, or staged at a one-week interval, is a safe and effective method to treat bilateral arthritis of the knee.