header advert
Results 1 - 6 of 6
Results per page:
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 6 - 6
1 Oct 2020
Hegde V Bracey DN Johnson R Dennis DA Jennings JM
Full Access

Introduction

Periprosthetic joint infection (PJI) is a devastating complication after total joint arthroplasty. Patients undergoing revision for PJI may experience considerable psychological distress and symptoms of depression, both of which are linked to poor post-operative outcomes. We therefore aim to identify the prevalence of depressive symptoms in patients prior to treatment for PJI.

Methods

All patients between September 2008 – October 2018 undergoing single or 2-stage revision for PJI with minimum 1-year follow-up were retrospectively reviewed at a single institution. The 2-stage (n=37) and single stage (n=39) patients that met inclusion criteria were matched based off age (+/−5), gender and BMI (+/−5) to patients undergoing aseptic revisions. Based on prior literature, patients were considered to have depressive symptoms if their VR-12 mental component score (MCS) was below 42. Using Student's t-tests, outcomes evaluated included pre-operative and 1-year post-operative VR-12 MCS and physical component scores (PCS).


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_9 | Pages 7 - 7
1 Oct 2020
Goswami K Clarkson S Dennis DA Klatt BA O'Malley M Smith EL Pelt CE Gililland J Peters C Malkani AL Palumbo B Minter J Goyal N Cross M Prieto H Lee G Hansen E Ward D Bini S Higuera C Levine B Nam D Della Valle CJ Parvizi J
Full Access

Introduction

Surgical management of PJI remains challenging with patients failing treatment despite the best efforts. An important question is whether these later failures reflect reinfection or the persistence of infection. Proponents of reinfection believe hosts are vulnerable to developing infection and new organisms emerge. The alternative hypothesis is that later failure is a result of an organism that was present in the joint but was not picked up by initial culture or was not a pathogen initially but became so under antibiotic pressure. This multicenter study explores the above dilemma. Utilizing next-generation sequencing (NGS), we hypothesize that failures after two stage exchange arthroplasty can be caused by an organism that was present at the time of initial surgery but not isolated by culture.

Methods

This prospective study involving 15 institutions collected samples from 635 revision total hip (n=310) and knee (n=325) arthroplasties. Synovial fluid, tissue and swabs were obtained intraoperatively for NGS analysis. Patients were classified per 2018 Consensus definition of PJI. Treatment failure was defined as reoperation for infection that yielded positive cultures, during minimum 1-year follow-up. Concordance of the infecting pathogen cultured at failure with NGS analysis at initial revision was determined.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 18 - 18
1 Oct 2019
Jennings JM Mejia M Williams MA Johnson RM Yang CC Dennis DA
Full Access

Background

Optimal perioperative fluid management has not been established in patients undergoing orthopaedic surgical procedures. Our purpose was to investigate the effects of perioperative fluid management on patients experiencing TKA.

Methods

One hundred thirty patients who met inclusion criteria undergoing primary unilateral TKA were prospectively randomized into traditional (TFG) vs. oral (OFG) perioperative fluid management groups. The TFG had a predetermined (4L) amount of intravenous fluids (IVF) administered in the perioperative period. The OFG began drinking a minimum of three, 20-ounces servings of clear fluids daily for three days prior to surgery. This cohort also drank 10-ounces of clear fluids 4 hours prior to surgery. Perioperative IVF were discontinued when the patient began oral intake or when the total amount of IVF reached 500mL. Outcome measures included: body-weight (BW) fluctuations, knee motion, leg girth, bioelectrical impendence, quadriceps activation, functional outcomes testing, KOOS JR, VR-12, laboratory values, vital signs, patient satisfaction, pain scores, and adverse events.


The Bone & Joint Journal
Vol. 101-B, Issue 7_Supple_C | Pages 84 - 90
1 Jul 2019
Jennings JM Loyd BJ Miner TM Yang CC Stevens-Lapsley J Dennis DA

Aims

The aim of this study was to determine whether closed suction drain (CSD) use influences recovery of quadriceps strength and to examine the effects of drain use on secondary outcomes: quadriceps activation, intra-articular effusion, bioelectrical measure of swelling, range of movement (ROM), pain, and wound healing complications.

Patients and Methods

A total of 29 patients undergoing simultaneous bilateral total knee arthroplasty (TKA) were enrolled in a prospective, randomized blinded study. Patients were randomized to receive a CSD in one limb while the contralateral limb had the use of a subcutaneous drain (SCDRN) without the use of suction (‘sham drain’). Isometric quadriceps strength was collected as the primary outcome. Secondary outcomes consisted of quadriceps activation, intra-articular effusion measured via ultrasound, lower limb swelling measured with bioelectrical impendence and limb girth, knee ROM, and pain. Outcomes were assessed preoperatively and postoperatively at day two, two and six weeks, and three months. Differences between limbs were determined using paired Student’s t-tests or Wilcoxon’s signed-rank tests.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 55 - 55
1 Oct 2018
Jennings JM Loyd BJ Miner T Yang CC Stevens-Lapsley J Dennis DA
Full Access

Introduction

Closed suction intraarticular drain (CSD) use after total knee arthroplasty (TKA) has been studied with regards to wound healing and range of motion, however, no data exist on how CSD use impacts knee joint effusion and quadriceps strength. The primary purpose of this study was to determine whether CSD use influences recovery of quadriceps strength. Secondary outcomes examined effects of CSD on intraarticular effusion, lower limb swelling, knee range of motion (ROM), pain and wound healing complications.

Methods

Twenty-nine patients undergoing same-day bilateral TKA were enrolled in a prospective, randomized blinded study. Subjects were randomized to receive a CSD on one lower extremity while the contralateral limb had the use of a subcutaneous drain (SCDRN) without the use of suction. Isometric quadriceps strength was collected as the primary outcome. Secondary outcomes consisted of quadriceps muscle activation, intraarticular effusion measured via ultrasound, lower extremity swelling measured with bioelectrical impendence, lower extremity girth, ROM, and pain. Outcomes were assessed preoperatively and postoperatively at day 2, 2 and 6 weeks and 3 months. Differences in limbs were determined using paired t-tests or Wilcoxon signed rank tests.


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 1 | Pages 33 - 39
1 Jan 2001
Dennis DA Komistek RD Walker SA Cheal EJ Stiehl JB

We carried out weight-bearing video radiological studies on 40 patients with a total knee arthroplasty (TKA), to determine the presence and magnitude of femoral condylar lift-off. Half (20) had posterior-cruciate-retaining (PCR) and half (20) posterior-cruciate-substituting (PS) prostheses. The selected patients had successful arthroplasties with no pain or instability. Each carried out successive weight-bearing knee bends to maximum flexion, and the radiological video tapes were analysed using an interactive model-fitting technique.

Femoral lift-off was seen at some increment of knee flexion in 75% of patients (PCR TKA 70%; PS TKA 80%). The mean values for lift-off were 1.2 mm with a PCR TKA and 1.4 mm with a PS TKA. Lift-off occurred mostly laterally with the PCR TKA, and both medially and laterally with the PS TKA. Separation between the femoral condyles and the articular surface of the tibia was recorded at 0°, 30°, 60° and 90° of flexion. Femoral condylar lift-off may contribute to eccentric polyethylene wear, particularly in designs of TKA which have flatter condyles. Coronal conformity is an important consideration in the design of a TKA.