header advert
Results 1 - 16 of 16
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 3 - 3
7 Aug 2023
Fennelly J Santini A Papalexandris S Pope J Yorke J Davidson J
Full Access

Abstract

Background

Oxidized zirconium (OxZr) has been introduced as an alternative bearing for femoral components in Total Knee Arthroplasty (TKA). It has a ceramic-like zirconium oxide outer layer with a low coefficient of friction. Early studies have found OxZr TKA to have a low incidence of early failure in young high demand patients. Currently no study has reported on the outcome of these implants beyond ten years.

Objectives

The purpose of our study was to present an in-depth 15-year survival analysis of cemented Profix II OxZr TKA.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_2 | Pages 3 - 3
1 Mar 2022
Guta D Santini A Fountain J Scott S Rourke H Davidson J Folb J
Full Access

Aims

The International Consensus Meeting on Musculoskeletal Infection (ICM, Philadelphia 2018) recommended histology as one of the diagnostic tests although this is not routinely used in a number of UK hospitals. This study aims to explore the role of histology in the diagnosis of infection and whether it is of practical use in those cases where the microbiology samples are either diagnostically unclear or do not correspond to the pre-operative diagnosis or the clinical picture.

Patients and Methods

We identified 85 patients who underwent revision knee arthroplasty for either septic or aseptic loosening and for whom both microbiology and histology samples were taken. The procedures were performed by the senior experienced surgeons specialised in revision knee arthroplasty in two centres from Liverpool. Each patient had a minimum of five tissue samples taken, using separate knife and forceps and each sample was divided in half and sent for microbiology and histology in different containers.

Fifty-four patients (63.5%) underwent a single-staged revision; ten patients (11.8%) underwent the 1st stage of a two staged revision; eleven patients (12.9%) underwent the 2nd stage of a two staged revision; one patient (1.2%) underwent an additional revision stage; three patients (3.5%) were treated with a DAIR; three patients (3.5%) had a 2-in-1 revision; two patients (2.4%) had a debridement and polyethylene exchange; and one patient (1.2%) had an arthroscopy biopsy of knee replacement.

The cost to process five microbiology samples for each patient was £122.45 on average and for the five histology samples was £130.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 3 - 3
1 Mar 2021
Chimutengwende-Gordon M Callary S Davidson J Costi K Pannach S Stamenkov R Howie DW Solomon LB
Full Access

Femoral impaction bone grafting (IBG) may be used to restore bone stock in revision total hip arthroplasty (THA) and allow use of a shorter, than otherwise, length prosthesis. This is most beneficial in young patients who are more likely to require further revision surgery. This study aimed to assess the results of femoral IBG for staged revision THA for infection. A prospective cohort of 29 patients who underwent staged revision THA for infection with femoral IBG and a cemented polished double-tapered (CPDT) stem at the final reconstruction was investigated.

The minimum follow-up was two years (2 – 10 years, median 6 years). Stem subsidence was measured with radiostereometric analysis. Clinical outcomes were assessed with the Harris Hip, Harris Pain, and and Société Internationale de Chirurgie Orthopédique et de Traumatologie Activity (SICOT) Scores. The original infection was eradicated in 28 patients. One patient required a repeat staged revision due to re-infection with the same organism. At two-year follow-up, the median subsidence at the stem-bone interface was −1.70 mm (−0.31 to −4.98mm). The median Harris Hip Score improved from 51 pre-operatively to 80 at two years (p=0.000), the Harris Pain Score from 20 to 44 (p=0.000) and the SICOT Score from 2.5 to 3 (p=0.003).

As successful eradication of infection was achieved in the majority of patients and the stem migration was similar to that of a primary CPDT stem, this study supports the use of femoral IBG during the final reconstruction of the femur after staged revision THA for infection.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_11 | Pages 22 - 22
1 Jun 2016
Davidson J Sabah S Berber R Hothi H Miles J Carrington R Power A Skinner J Hart A
Full Access

Introduction

The Birmingham Hip Resurfacing (Smith & Nephew London, UK) is the most popular hip resurfacing (HR) in the UK. However, it is now subject to two Medical Device Alerts (MDA) from the Medicines and Healthcare products Regulatory Agency (MHRA).

Patients/Materials & Methods

A cross-sectional survey of primary metal-on-metal hip procedures recorded on the National Joint Registry for England, Wales and Northern Ireland (NJR) until 5th November 2013 was performed.

Cost-analysis was based on an algorithm for surveillance of HR at a tertiary referral centre and followed previous MHRA guidance. NIHR NHS Treatment costs were used.

The local protocol encompassed: patient outcome scoring (Oxford hip score), blood metal ion measurement (cobalt, chromium), cross-sectional imaging (MRI) and discussion at an internet-enabled multidisciplinary team meeting (iMDT) in addition to routine hip surveillance.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 310 - 310
1 Dec 2013
Frostick S Roebuck M Davidson J Santini A Peter V Banks J Williams A Wang H Thachil J Jackson R
Full Access

Introduction:

Wear debris from articulating joint implants is inevitable. Small debris particles are phagocytosed by macrophages. Larger particles initiate the fusion of many macrophages into multi-nucleated giant cells for particle encasement. Macrophages are recruited into inflamed tissues from the circulating monocyte population. Approximately 10% of white blood cells are monocytes which after release from the bone marrow circulate for 2–3 days, before being recruited into tissues as inflammatory macrophages or undergoing apoptosis. Circulating MRP8/14 (S100A8/A9) is a measure of monocyte recruitment, part of the monocyte-endothelial docking complex, and shed during monocyte transmigration across the endothelium. The higher the S100A8/A9 the more monocytes being recruited giving an indirect measure of debris production.

Methods:

2114 blood samples were collected from arthroplasty patients with hip or knee osteoarthritis (primary, post-traumatic and secondary), 589 before their primary arthroplasty, 1187 patients > 1 year post-arthroplasty, 101 patients before revision for aseptic loosening and 237 patients >1 year post-revision. Plasma S100A8/A9 was measured using BMA Biomedicals Elisa kit, normal levels in health adults are 0.5–3 mg/ml. Joint specific scores, WOMAC knee or Oxford Hip adjusted to percent of maximum, together with SF-12 were completed.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 311 - 311
1 Dec 2013
Frostick S Williams A Wang H Davidson J Santini A Thachil J Banks J Jackson R Roebuck M
Full Access

Introduction:

The risk factors for degenerative joint disease are well established: increasing age, obesity, joint abnormalities, trauma and overuse, together with female gender, ethnic and genetic factors. That obesity is a significant risk factor for developing osteoarthritis in non-weight-bearing as well as weight-bearing and joints was one of the first indications that the risk was nor purely that of aberrant biomechanical loading. Low grade chronic systemic inflammation is a component of each of ageing and obesity, atherosclerosis and diabetes, culminating in Metabolic Syndrome. In our study of 1684 patients with joint degeneration 85% were overweight or obese and 65% older than 65 years with 62% being both, 73% of patients were taking medications for serious, ‘non-orthopaedic’ health problems such as cardiovascular or respiratory disease, obesity or NIDDM. Monocytes are a major component of chronic inflammation, approximately 10% of white blood cells are monocytes which circulate for 2–3 days, before being recruited into tissues as inflammatory macrophages or undergoing apoptosis. Circulating S100A8/A9 (MRP8/14) is a measure of monocyte recruitment being shed during monocyte transmigration across the endothelium. The higher the S100A8/A9 the more monocytes being recruited giving an indirect measure of chronic inflammatory status.

Methods:

2154 blood samples were collected from arthroplasty patients (first or second joint replacement), 1135 Female and 1019 Male, age 29–93 years, body mass index (BMI) 18–56, with hip or knee osteoarthritis (primary, post-traumatic and secondary), 589 before a primary arthroplasty, 1187 patients >1 year post-arthroplasty, 101 patients before revision for aseptic loosening and 237 patients >1 year post-revision. All study patients received metal on UHMWPE implants. Plasma S100A8/A9 was measured using BMA Biomedicals Elisa kit, normal levels in healthy adults are 0.5–3 mg/ml. The data were analysed using SPSS, p values were calculated using Spearman's test.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 474 - 474
1 Sep 2012
Atrey A Edmondson M East D Miles K Ellens N Butt D Butler-manuel A Warshafsky J Davidson J
Full Access

In this review, we present the data of one of the largest non-designer, mid- to long-term follow ups of the AGC.

We present a total of 1538 AGC knees during a 15 year period, of which 902 were followed up by postal or telephone questionnaire focused on Oxford Knee Scores, Visual analogues of function and pain and survival analyses performed. Mean length of follow up was 10.4 years.

85.7% of patients had an Oxford knee score of between 0 and 40, with 71.2% scoring between 0–30.

65.6% of patients responded with a Visual Analogue Score (VAS) of 0 or 1 at rest (minimum pain 0) and 53.9% reporting VA scores of 0 or 1 while walking.

87.5% of patients reported Excellent or good functional reports at final follow up and 90.3% reporting excellent or good pain control compared to per-operative levels.

Survival analysis confirms excellent survivorship.

This large cohort and multi-surgeon trial reproduces the excellent results as demonstrated by the designer centre (Ritter et al.). Mid to long term outcome sows excellent function and analgesia. Complication rates are low and the necessity for revision remains low.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 72 - 72
1 Sep 2012
Cohen D Cartwright-Terry M Pope J Davidson J Santini A
Full Access

Purpose

To review the outcomes of patients undergoing manipulation under anaesthetic (MUA) after primary total knee arthroplasty (TKA) and predict those that may require such a procedure.

Methods

Prospective analysis of patients who required MUA post TKA performed by two surgeons using the same prosthesis from 2003 to 2008. Compared to a control group of primary TKA matched for age, gender and surgeon. All patients in both groups had pre- and post-operative measurements of range of movement. Risk factors were identified including warfarin and statin use, diabetes and body mass index.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 68 - 68
1 Sep 2012
Davidson J Chana R Miles K East D Apthorp H Butler-Manuel P
Full Access

Introduction

The Oxford Total Meniscal Knee (TMK by Biomet), is a total knee replacement with a multidirectional mobile bearing. As part of the evaluation of the TMK we compared our group of TMK knee replacements with an equivalent cohort of AGC total knee replacements.

Methods

Patients recruited to AGC trial from 1994 to 2001. 254 AGC knee replacements sequentially recruited in 210 patients. Patients recruited to TMK trial from 2001 to 2007. 221 TMK knee replacements sequentially recruited in 193 patients. Patients prospectively randomised to having uncemented HA coated (HAC) or cemented versions in both groups. Each patient was reviewed pre-operatively, at 6 weeks, 6 months, 1 year and then annually.

All AGC & TMK TKR's were assessed clinically using HSS scores and radiographically. TMK group also assessed using AKSS and OKQ scores.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 60 - 60
1 Jul 2012
Colaço H Davidson J Pekicten B Ahmed S Skyrme A Armitage A Rajaratnam S
Full Access

Purpose

This study investigates the effect of early tourniquet release on range of flexion following total knee replacement, and the influence of anticoagulation with Rivaroxaban and Clexane (Enoxaparin).

Method

78 patients were included in the study, who underwent unilateral primary total knee replacement (TKR) in our department under the care of two specialist knee surgeons over a 12 month period. 27 patients underwent TKR with early release of the tourniquet and haemostasis, prior to closure of quadriceps layer: 22 were anticoagulated with Rivaroxaban (GROUP ER), 15 with the low molecular weight heparin Clexane (GROUP EC). Over the same time period, 41 patients TKR with late release of the tourniquet, following closure and bandaging: 13 were anticoagulated with Rivaroxaban (GROUP LR), 28 with Clexane (GROUP LC). A standardised operative technique was employed, and all patients received an AGC (Biomet) PCL-retaining prostheses. Outcome was assessed with range of flexion at 12 weeks postoperatively.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 106 - 106
1 Jul 2012
Cartwright-Terry M Cohen D Pope J Davidson J Santini A
Full Access

Purpose

To review the outcomes of patients undergoing manipulation under anaesthetic (MUA) after primary total knee arthroplasty (TKA) and predict those that may require such a procedure.

Methods

We prospectively analysed all patients who required MUA post TKA performed by 2 surgeons using the same prosthesis from 2003 to 2008 and compared them to a control group of primary TKA matched for age, gender and surgeon. All patients in both groups had pre- and post-operative measurements of range of movement. In addition risk factors were identified including warfarin and statin use, diabetes and body mass index.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 562 - 563
1 Oct 2010
Davidson J Broderick A Davies B Floyd A Kothari A Shah Y Sushma S
Full Access

Introduction: Lumbar disc disease comprises of a heavy portion of the workload in spinal as well as general orthopaedic clinic.

It is well accepted that nerve root tension signs such as straight leg raise (SLR) & Lasegue’s test are sensitive at diagnosing nerve root impingement secondary to lumbar disc degeneration. In isolation, however, they lack specificity & have a poor positive predictive value (PPV). This can lead to uncertainty in clinical diagnosis.

Our study proves that a structured approach to clinical examination with cumulative nerve root tension signs (RTS) significantly increases the tests’ specificity and PPV, therefore giving clinicians more confidence in their diagnosis.

Methods: Prospective review of 1303 patients seen in one Orthopaedic consultant’s spinal clinic from 2004 until 2008. Data was collected using a standardized proforma. Pattern of pain as well as RTS (SLR, Lasegue, bowstring and crossover) were recorded and cross-referenced with subsequent MRI findings. In our dataset a positive MRI result was one in which the demonstrated disc lesion and nerve impingement corresponded with patient symptoms. Patients included were all those presenting with lower back and/or neuropathic leg pain. Patients had to be excluded from series due to incomplete datasets & missing MRI scans.

Results: N = 858. Our results showed that as we progressed from 1 RTS up to 4 RTS there was a significant increase in the PPV : 1RTS PPV = 0.333 (CI 0.25 – 0.43), 2RTS PPV = 0.78 (CI 0.69 – 0.86), 3RTS PPV 0.87 (CI 0.81 – 0.91), 4RTS PPV 0.93 (CI 0.66 – 0.99). There was also significant increases in specificity compared with 1RTS: 1RTS 0.75 (CI 0.70 – 0.8), 2RTS 0.94 (CI 0.91 – 0.96), 3RTS 0.92 (CI 0.89 – 0.95), 4RTS 0.99 (CI 0.98 – 0.99).

Discussion: This study shows that combining root tension signs as part of a structured assessment leads to a significant cumulative increase in the PPV and specificity of the diagnosis of nerve root impingement. Hence proving the importance of clinical examination. This method of sequential, cumulative RTS has not previously been documented in the literature.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 418 - 418
1 Jul 2010
Jakaraddi C Garcia-Finana M Neal T Navin A Davidson J Santini A
Full Access

Aim: To compare the in-vitro elution characteristics of CMW1 and Palacos R bone cements containing gentamicin or teicoplanin or a combination of both.

Materials & Methods: Four types of bone cement discs (28x22mm) were prepared.

Disc 1(control) contained Palacos R or CMW1 cement without any added antibiotic.

Disc2 contained Palacos R or CMW1 with gentamicin.

Disc 3 contained Palacos R or CMW1 with teicoplanin.

Disc 4 contained Palacos R or CMW1 with gentamicin and teicoplanin powder.

The discs containing teicoplanin were prepared by adding teicoplanin powder (2gm) to the respective cement powder (40 gm with or without 0.5gm of gentamicin) and then adding the monomer (vacuum mixing).

All the discs were immersed in 50 ml normal saline bath in a sterile pot and maintained at temperature of 37 deg Celsius. 24 hours later a 5ml sample was taken from each pot for assay, to measure the amount of antibiotic eluted, using fluorescence polarization immuno-assay technique. The discs were then removed from the pots, washed with normal saline and reimmersed in a fresh 50 ml saline pot. This procedure was repeated at hours 48, 72, 120 and week 1, 2, 3 & 6 for all discs.

Results: All discs and assays were done in triplicate and average total value at 6 weeks (μ gm/ml) taken for statistical analysis.

CMW1:

Gentamicin eluted from disc4 was higher than disc2 (94.9 v 34.37. p< 0.0003).

Teicoplanin eluted from disc4 was higher than disc3 (202.1 v 147.57. p< 0.004).

PALACOS R:

Gentamicin eluted from disc4 was higher than disc2 (144.17 v 86.43. p< 0.0004).

Teicoplanin eluted from disc4 was less than disc3 (140.17 v 213.73. p< 0.008)

Conclusion: Palacos R cement elutes more antibiotic than CMW1 and antibiotic combination in bone cement resulted in, mostly, synergistic effect of increased elution of individual antibiotic.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 407 - 408
1 Jul 2010
Fountain J Jakaraddi C Pope J Davidson J Santini A
Full Access

We present a prospective trial examining the effect of posterior tibial slope at total knee arthroplasty (TKA) on the range of movement and functional outcome.

Current literature shows little difference clinically in TKA with increasing posterior tibial slope. Previous studies have been retrospective or involved small numbers and may represent poor ligament balancing or inaccurate alignment.

In a prospective, double-blinded, randomised controlled trial, 250 patients undergoing primary Profix TKA, were randomised to receive either a 0 or 4 degree posterior tibial cut. Range of movement (ROM) was measured pre-operatively, at 3 months and 1 year by a single clinical physiotherapist. SF-12 and WOMAC scores were calculated at the same visit. Both patient and physiotherapist were blinded to the angle of tibial slope.

Mean one year post operative ROM was greater by 2 degrees (p=0.470) in those with a 4 degree tibial slope. Post operatively both groups had significant improvement in functional outcome scores. A 0.2 (p= 0.892) and 0.51 (p= 0.707) greater improvement in SF12 physical score and mental scores respectively was found in the 0 degree group at one year. There was also a 1.09 (p=0.718) greater improvement in WOMAC score with a 0 degree slope.

In conclusion increased posterior tibial slope gives a marginally better but non-significant post operative ROM and makes no significant difference to functional outcome.


The Journal of Bone & Joint Surgery British Volume
Vol. 70-B, Issue 3 | Pages 457 - 460
1 May 1988
Richardson J Ramsay A Davidson J Kelly I

It is difficult to establish the diagnosis of an injured shoulder if only one radiographic projection is used. We have compared two lateral projections, the Neer trans-scapular and the apical oblique in 80 patients; the radiographs were presented randomly to 10 casualty officers and nine radiologists. The apical oblique view was found to permit more accurate diagnosis of fractures and of dislocation by both groups.


The Journal of Bone & Joint Surgery British Volume
Vol. 58-B, Issue 4 | Pages 492 - 495
1 Nov 1976
Davidson J Beighton P

During the course of a nation-wide survey of patients with bone and joint deformities, twenty-six individuals with arthrogryposis multiplex congenita, in the narrow and precise sense of the term, were investigated. No patient was more than twenty-four years of age. However, on a basis of the figures of population, it can be estimated that 21-0 +/- 6-5 older affected individuals should have been encountered. Furthermore, there was a relative excess of younger children. The series was reasonably unbiased, and as arthrogryposis is non-lethal the deficiency of affected adults is an anomalous finding. It is tentatively suggested that arthrogryposis might result from the intra-uterine influence of an unknown environmental agent which has been present in South Africa for only a limited period of time. Detection of this factor could be an important step in the prevention of the disease.