Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_5 | Pages 8 - 8
1 Feb 2016
Suarez-Ahedo C Gui C Martin T Stake C Chandrasekaran S Christopher J Domb B
Full Access

Background

Preservation of acetabular bone during primary total hip arthroplasty (THA) is important, because proper stability of cementless acetabular cup during primary THA depends largely on the amount of bone stock left after acetabular reaming. Eccentric or excessive acetabular reaming can cause soft tissue impingement, loosening, altered centre of rotation, bone-to-bone impingement, intra-operative periprosthetic fracture, and other complications. Furthermore, loss of bone stock during primary THA may adversely affect subsequent revision THA.

Questions/Purposes

The purpose of this study was to compare preservation of acetabular bone stock between conventional THA (CTHA) vs. robotic-guided THA (RGTHA). We hypothesised that RGTHA would allow more precise reaming, leading to use of smaller cups and greater preservation of bone stock.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_5 | Pages 2 - 2
1 Feb 2016
Domb B Redmond J Petrakos A Gui C Christopher J Lodhia P Suarez-Ahedo C
Full Access

Introduction

Lewinnek et al described a safe zone of acetabular component placement in Total Hip Arthroplasty (THA) to reduce complications. Callanan et al proposed a modified safe zone with a reduced range of acetabular inclination of 30–45 degrees to eliminate the steeper or more inclinated cups 2. This study compares the accuracy of cup placement in the safe zones described by Lewinnek et al and Callanan et al, leg length discrepancy (LLD) and global offset (GO) measurement in THA using five different surgical techniques performed by six different surgeons.

Methods

Between June 2008 and April 2014, 2330 THRs were performed by six different surgeons. Post-operative radiographic images were retrospectively reviewed and measured using TraumaCad® software to determine cup placement, LLD, and GOD.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 50 - 50
1 Jan 2016
Borus T Roberts D Fairchild P Christopher J Conditt M Branch S Matthews J Pirtle K Baer M
Full Access

Introduction

Unicompartmental Knee Arthroplasty (UKA) has been offered as a tissue sparing alternative to total knee arthroplasty (TKA) for treatment of early to mid-stage osteoarthritis (OA). While the spared tissue and retention of cruciate ligaments may result in faster recovery, smaller incision, less bone resection, decreased pain and blood loss and more normal kinematics and function, UKA has shown unpredictable results in practice, which may be due to variations in surgical techniques1. Recently a robotic-assisted technique has been introduced as a means to provide more consistent and reproducible surgical results. In this study, the early return to function was measured to determine proposed benefits between UKA and TKA.

Methods

Patients requiring either UKA or TKA were prospectively enrolled in this IRB approved study. Each patient received pre-operative education regarding their expected physical therapy (PT) regimen, which was uniform for all patients. PT was determined to be concluded when each patient reached an achievable functional endpoint with each of the following 5 criteria: range of motion from 5 to 115 degrees, recovery of flexion and extension strength to 4/5 of pre-operative strength, gait with minimal limp and without an assistive device for 250 feet and ability to ascend and descend a flight of stairs with step over gait and good control. The number of PT visits to reach each functional goal was recorded.