header advert
Results 1 - 4 of 4
Results per page:
Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_3 | Pages 11 - 11
1 Feb 2014
Bell S Brown M Hems T
Full Access

Myotome values for the upper limb appear to have been established in the early twentieth century based on historical work. Supraclavicular brachial plexus injuries present with a pattern of neurological loss consistent to the nerve roots affected. Recent advances in radiological imaging and intraoperative nerve stimulation have allowed confirmation of the affected nerve roots.

The records of 43 patients with partial injuries to the supraclavicular brachial plexus were reviewed. The injuries covered the full range of injury patterns including those affecting C5, C5-6, C5-7, C5-8, C7-T1 and C8-T1 roots. All cases with upper plexus injuries had surgical exploration of the brachial plexus with the injury pattern being classified on the basis of whether the roots were in continuity, ruptured, or avulsed, and, if seen in continuity, the presence or absence of a response to stimulation. For lower plexus injuries the classification relied on identification of avulsed roots on Magnetic Resonance Imaging. Muscle powers recorded on clinical examination using the MRC grading system.

In upper plexus injuries paralysis of flexor carpi radialis indicated involvement of C7 in addition to C5-6, and paralysis of triceps and pectoralis major suggested loss of C8 function. A major input from T1 was confirmed for flexor digitorum superficialis, flexor digitorum profundus (FDP) to the radial digits, and extensor pollicis longus. C8 was the predominant innervation to the ulnar side of FDP and intrinsic muscles innervated by the ulnar nerve with some contribution from C7.

A revised myotome chart for the upper limb is proposed.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 293 - 293
1 Sep 2012
Gaheer RS Dillon J Bell S Ferdinand R
Full Access

Arthordesis of small joints of the foot is a commonly performed procedure in orthopaedics. A variety of fixation devices have been used for this purpose. Nickel-Titanium Memory compression staples for arthrodesis have been used in our institute since June 2003. We report the results of the procedure over a period of 7years involving 252 feet in 232 consecutive patients who underwent arthrodesis or an osteotomy fixation using compression staples. The patients were evaluated to determine the period of immobilization in cast and the time to radiographic joint fusion.

The emphasis of this study was to validate the safety of the implant for fusion of small joints of the foot, as well as to determine whether there is a demonstrable trend in time to fusion and period of immobilization required.

The average time to fusion was 7.2 weeks, the average period of immobilisation was 6.5 weeks. Successful union was achieved in 98% cases. We report the follow up results, finer technical aspects of the procedure and pitfalls to avoid whilst performing the fusions.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 499 - 499
1 Sep 2012
Bell S Young P Drury C Blyth M Jones B Mclean A
Full Access

Introduction

Total knee arthroplasty is an established and successful operation. In up to 10% of patients who undergo total knee arthroplasty continue to complain of pain [1]. Recently computerised tomography (CT) has been used to assess the rotational profile of both the tibial and femoral components in painful total knee arthroplasty.

Methods

We reviewed 56 painful total knee replacements and compared these to 59 pain free total knee replacements. Datum gathered from case notes and radiographs using a prospective orthopaedic database to identify patients. The age, sex, preoperative Oxford score and BMI, postoperative Oxford score and treatments recorded. The CT information recorded was limb alignment, tibial component rotation, femoral component rotation and combined rotation.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIII | Pages 14 - 14
1 Jul 2012
Bell S Young P Drury C Jones CB Blyth M MacLean A
Full Access

Total knee arthroplasty (TKA) is an established and successful operation. However patient satisfaction rates vary from 81 to 89% 1,2,3. Pain following TKA is a significant factor in patient dissatisfaction 1. Many causes for pain following total knee arthroplasty have been identified 4 but rates of unexplained pain vary from 4 to 13.1% 5,6. Recently computerised tomography (CT) has been used to assess the rotational profile of both the tibial and femoral components in painful TKA

We reviewed 57 patients with an unexplained painful following TKA and compared these to a matched control group of 60 patients with TKA. Datum gathered from case notes and radiographs using a prospective database to identify patients. The CT information recorded was limb alignment, tibial component rotation, and femoral component rotation and combined rotation.

The two matched cohorts of patients had similar demographics. A significant difference in tibial, femoral and combined component rotation was identified between the groups. The following mean rotations were identified for the painful and control groups respectively. Tibial rotation was 3.46 degrees internal rotation (IR) compared to 2.50 degrees external rotation (ER)(p=0.001). Femoral rotation was 2.30 IR compared to 0.36 ER(p=0.02). Combined rotation was 7.08 IR compared to 2.85 ER(p=0.001).

This is the largest study presently in the literature. We have identified significant internal rotation in a patient cohort with unexplained painful TKA when compared to a matched control group. Internal rotation of the tibial component, femoral component and combined rotation was identified as a factor in unexplained pain following TKA.