Advertisement for orthosearch.org.uk
Results 1 - 20 of 754
Results per page:
Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 37 - 37
1 Dec 2020
Yıldırımkaya B Söylemez MS Uçar BY Akpınar F
Full Access

Introduction and Purpose. Metacarpal fractures constitute approximately one third of all hand fractures. The majority of these fractures are treated by conservative non-surgical methods. The aim of this study is to obtain the appropriate anatomical alignment of the fracture with dynamic metacarpal stabilization splint (DMSS) and to maintain the proper bone anatomy until the union is achieved. In addition, by comparing this method with short arm plaster splint (SAPS) application, it is aimed to evaluate whether patients are superior in terms of comfort, range of motion (ROM) and grip strength. Materials and Methods. In our study, SAPS or DMSS was applied to the patients with 5th metacarpal neck fracture randomly after fracture reduction and followed for 3 months. A total of 119 patients with appropriate criteria were included in the study. Radiological alignment of the fracture and amount of joint movements were evaluated during follow-up. Grip strength was evaluated with Jamar dynamometer. EQ-5D-5L and VAS scores were used for clinical evaluation. Results. 103 patients completed their follow-up. 51 patients were treated with SAPS and 52 patients were treated with DMSS. The mean age of the SAPS was 29.5 (SD ± 9.4; 16–53 years) and the mean age of the DMSS group was 27.8 (SD ± 11.6; 16–63). Pressure sores was seen in 5 patients in the DMSS group, while no pressure sore was seen in the SAPS (p = 0.008). There was no significant difference between the two groups in the VAS scores at all times. There was no significant difference between the mean dorsal cortical angulation (DCA) before the reduction, after the reduction and at the third month follow-ups. There was no statistically significant difference between the length of metacarps at first admittion before reduction, after reduction and at third month follow-ups. When the grip strength of the two groups were compared as a percentage, the grip strength of the patients in the DMSS group was found to be higher at 1st month, 2nd month and 3rd month (p <0.001). When the ROM values of the patients were evaluated, DMSS group had a higher degree of ROM in the first month compared to the SAPS group (p <0.001). No statistically significant difference was detected among groups at third month in the ROM of the IP and MP joints. However, wrist ROM was statistically higher in DMSS group at 3rd month (p <0.05). There was a statistically significant difference between EuroQol scores in favor of DMSA group (p <0.05). Discussion and Conclusion. In stable 5th metacarpal neck fractures, DMSA is as effective as SAPS to maintain bone anatomy. In addition, DMSA can be preferred for fixation plaster splint or circular plaster applications for the prevention of reduction in boxer fractures, with the advantage of having high clinical scores, which is an indication of early acquisition of grip strength, ease of use and patient comfort


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 5 | Pages 716 - 719
1 Jul 2002
Wilkinson AG Sherlock DA Murray GD

We have reviewed the outcome of 134 hips in 96 children with Graf type-III or type-IV dysplasia of the hip on ultrasound examination. We treated 28 affected hips in 22 children with the Craig splint, 43 hips in 30 children with the Pavlik harness, and 26 hips in 16 children with the von Rosen splint. A total of 37 affected hips in 28 children was not splinted. All children were less than three months of age at referral. Those treated with the von Rosen splint had a significantly better ultrasound appearance at 12 to 20 weeks of age and fewer radiological abnormalities than those not splinted or treated with the Pavlik harness. In the von Rosen group no hip required further treatment with an abduction plaster or operation compared with ten in the Pavlik harness group, three in the Craig splint group and eight in the group without splintage. Our results suggest that the von Rosen splint is more likely to improve the outcome of neonatal dysplasia of the hip and a definitive, large-scale randomised trial is therefore indicated


Aims. The study was undertaken to compare the efficacy of Woodcast splints and plaster-of-Paris casts in maintaining correction following sequential manipulation of idiopathic clubfeet. Methods. In this randomized prospective trial, 23 idiopathic clubfeet were immobilized with plaster-of-Paris casts and 23 clubfeet were immobilized with a splint made of Woodcast that encircled only two-thirds the circumference of the limb. The number of casts or splints needed to obtain full correction, the frequency of cast or splint-related complications, and the time taken for application and removal of the casts and splints were compared. Results. The mean number of casts required to obtain full correction of the deformity (Pirani Score 0) was 4.35 (95% confidence interval (CI) 3.74 to 4.95) when plaster-of-Paris was used and 4.87 (95% CI 4.33 to 5.41) when the Woodcast splint was used (p = 0.190). The time required for application and removal of the Woodcast splint were significantly less than that required for application and removal of plaster-of-Paris casts (p < 0.001). Woodcast splint-related complications were not more frequent than plaster-of-Paris cast related complications. Conclusion. Though Woodcast splints covering two-thirds of the circumference of the lower limbs of infants were effective in maintaining the correction of clubfoot deformity during serial manipulation and casting treatment, the superiority of Woodcasts over plaster-of-Paris could not be established. Cite this article: Bone Joint J 2020;102-B(10):1399–1404


The Bone & Joint Journal
Vol. 103-B, Issue 5 | Pages 991 - 998
1 May 2021
Lyu X Chen T Yang Z Fu G Feng C Zhang T Lu M

Aims. The objective of this study was to evaluate the clinical and radiological outcomes of patients younger than six months of age with developmental dysplasia of the hip (DDH) managed by either a Pavlik harness or Tübingen hip flexion splint. Methods. Records of 251 consecutive infants with a mean age of 89 days (SD 47), diagnosed with DDH between January 2015 and December 2018, were retrospectively reviewed. Inclusion criteria for patients with DDH were: younger than 180 days at the time of diagnosis; ultrasound Graf classification of IIc or greater; treatment by Pavlik harness or Tübingen splint; and no prior treatment history. All patients underwent hip ultrasound every seven days during the first three weeks of treatment and subsequently every three to four weeks until completion of treatment. If no signs of improvement were found after three weeks, the Pavlik harness or Tübingen splint was discontinued. Statistical analysis was performed. Results. The study included 251 patients with Graf grades IIc to IV in 18 males and 233 females with DDH. Mean follow-up time was 22 months (SD 10). A total of 116 hips were graded as Graf IIc (39.1%), nine as grade D (3.0%), 100 as grade III (33.7%), and 72 as grade IV (24.2%). There were 109 patients (128 hips) in the Pavlik group and 142 patients (169 hips) in the Tübingen group (p = 0.227). The Tübingen group showed a 69.8% success rate in Graf III and Graf IV hips while the success rate was significantly lower in the Pavlik group, 53.9% (p = 0.033). For infants older than three months of age, the Tübingen group showed a 71.4% success rate, and the Pavlik group a 54.4% success rate (p = 0.047). Conclusion. The Tübingen splint should be the preferred treatment option for children older than three months, and for those with severe forms of DDH such as Graf grade III and IV, who are younger than six months at time of diagnosis. The Tübingen hip flexion splint is a valid alternative to the Pavlik harness for older infants and those with more severe DDH. Cite this article: Bone Joint J 2021;103-B(5):991–998


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1405 - 1411
3 Oct 2020
Martynov I Klink T Slowik V Stich R Zimmermann P Engel C Lacher M Boehm R

Aims. This exploratory randomized controlled trial (RCT) aimed to determine the splint-related outcomes when using the novel biodegradable wood-composite splint (Woodcast) compared to standard synthetic fibreglass (Dynacast) for the immobilization of undisplaced upper limb fractures in children. Methods. An exploratory RCT was performed at a tertiary paediatric referral hospital between 1 June 2018 and 30 September 2019. The intention-to-treat population consisted of 170 patients (mean age 8.42 years (SD 3.42); Woodcast (WCG), n = 84, 57 male (67.9%); Dynacast (DNG), n = 86, 58 male (67.4%)). Patients with undisplaced upper limb fractures were randomly assigned to WCG or DNG treatment groups. Primary outcome was the stress stability of the splint material, defined as absence of any deformations or fractures within the splint during study period. Secondary outcomes included patient satisfaction and medical staff opinion. Additionally, biomechanical and chemical analysis of the splint samples was carried out. Results. Of the initial 170 patients, 168 (98.8%) completed at least one follow-up, and were included for analysis of the primary endpoint. Both treatment groups were well-matched regarding to age, sex, and type and localization of the fracture. Splint breakage occurred in three patients (3.6%; 95% confidence interval (CI), 0.007% to 0.102%) in the WCG and in three children (3.5%, 95% CI 0.007% to 0.09%) in the DNG (p > 0.99). The incidence of splint-related adverse events did not differ between the WCG (n = 21; 25.0%) and DNG (n = 24; 27.9%; p = 0.720). Under experimental conditions, the maximal tensile strength of Dynacast samples was higher than those deriving from Woodcast (mean 15.37 N/mm² (SD 1.37) vs 10.75 N/mm² (SD 1.20); p = 0.002). Chemical analysis revealed detection of polyisocyanate-prepolymer in Dynacast and polyester in Woodcast samples. Conclusion. Splint-related adverse events appear similar between WCG and DNG treatment groups during the treatment of undisplaced forearm fractures. Cite this article: Bone Joint J 2020;102-B(10):1405–1411


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 696 - 704
1 Jul 2024
Barvelink B Reijman M Smidt S Miranda Afonso P Verhaar JAN Colaris JW

Aims. It is not clear which type of casting provides the best initial treatment in adults with a distal radial fracture. Given that between 32% and 64% of adequately reduced fractures redisplace during immobilization in a cast, preventing redisplacement and a disabling malunion or secondary surgery is an aim of treatment. In this study, we investigated whether circumferential casting leads to fewer fracture redisplacements and better one-year outcomes compared to plaster splinting. Methods. In a pragmatic, open-label, multicentre, two-period cluster-randomized superiority trial, we compared these two types of casting. Recruitment took place in ten hospitals. Eligible patients aged ≥ 18 years with a displaced distal radial fracture, which was acceptably aligned after closed reduction, were included. The primary outcome measure was the rate of redisplacement within five weeks of immobilization. Secondary outcomes were the rate of complaints relating to the cast, clinical outcomes at three months, patient-reported outcome measures (PROMs) (using the numerical rating scale (NRS), the abbreviated version of the Disabilities of the Arm, Shoulder and Hand (QuickDASH), and Patient-Rated Wrist/Hand Evaluation (PRWHE) scores), and adverse events such as the development of compartment syndrome during one year of follow-up. We used multivariable mixed-effects logistic regression for the analysis of the primary outcome measure. Results. The study included 420 patients. There was no significant difference between the rate of redisplacement of the fracture between the groups: 47% (n = 88) for those treated with a plaster splint and 49% (n = 90) for those treated with a circumferential cast (odds ratio 1.05 (95% confidence interval (CI) 0.65 to 1.70); p = 0.854). Patients treated in a plaster splint reported significantly more pain than those treated with a circumferential cast, during the first week of treatment (estimated mean NRS 4.7 (95% CI 4.3 to 5.1) vs 4.1 (95% CI 3.7 to 4.4); p = 0.014). The rate of complaints relating to the cast, clinical outcomes and PROMs did not differ significantly between the groups (p > 0.05). Compartment syndrome did not occur. Conclusion. Circumferential casting did not result in a significantly different rate of redisplacement of the fracture compared with the use of a plaster splint. There were comparable outcomes in both groups. Cite this article: Bone Joint J 2024;106-B(7):696–704


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 540 - 544
1 Apr 2009
Robinson PM O’Meara MJ

The Thomas splint is a common piece of equipment in emergency departments and orthopaedic units in hospitals worldwide. Its basic design has changed little since its first description by Hugh Owen Thomas was published in 1875. We have reviewed the origins of the Thomas splint as a means of correction of deformities of the lower limb and its evolution through both World Wars into an essential item for the management of trauma of the lower limb


The Journal of Bone & Joint Surgery British Volume
Vol. 81-B, Issue 6 | Pages 1023 - 1028
1 Nov 1999
Williams PR Jones DA Bishay M

Between January 1987 and December 1988 there were 7575 births in the Swansea maternity unit. Of these 823 (10.9%) were considered to be at ‘high risk’ for developmental dysplasia of the hip (DDH). Static ultrasound examination was performed in each case and the results classified on the basis of the method of Graf. A total of 117 type III–IV hips in 83 infants was splinted using the Aberdeen splint. Radiographs of these hips were taken at six and 12 months. Hilgenreiner’s measurements of the acetabular angle were made in all cases and the development of the femoral capital epiphysis was assessed by measuring the epiphyseal area. The effect of splintage on the acetabular angle and the epiphyseal area between the normal and abnormal splinted hips was compared. Radiographs of 16 normal infants (32 normal unsplinted hips) were used as a control group. This cohort has now been followed up for a minimum of nine years. There have been no complications as a result of splintage. The failure rate was 1.7% or 0.25 per 1000 live births. No statistical difference was found when comparing the effect of splintage on the acetabular angle and epiphyseal area between normal and abnormal splinted hips and normal unsplinted hips. Our study has shown that while the Aberdeen splint had a definite but small failure rate, it was safe in that it did not produce avascular necrosis. The current conventional view that a low rate of splintage is always best is therefore brought into question if the Aberdeen splint is chosen for the management of neonatal DDH


The Journal of Bone & Joint Surgery British Volume
Vol. 82-B, Issue 1 | Pages 74 - 78
1 Jan 2000
Gelinas JJ Faber KJ Patterson SD King GJW

We have treated 22 patients with an elbow contracture using a static progressive turnbuckle splint for a mean of 4.5 ± 1.8 months. All had failed to improve with supervised physiotherapy and splinting. The mean range of flexion before splintage was from 32 ± 10° to 108 ± 19° and afterwards from 26 ± 10° (p = 0.02) to 127 ± 12° (p = 0.0001). A total of 11 patients gained a ‘functional arc of movement,’ defined as at least 30° to 130°. In eight patients movement improved with turnbuckle splinting, but the functional arc was not achieved. Six of these were satisfied and did not wish to proceed with surgical treatment and two had release of the elbow contracture. In three patients movement did not improve with the use of the turnbuckle splint and one subsequently had surgical treatment. Our findings have shown that turnbuckle splinting is a safe and effective treatment which should be considered in patients whose established elbow contractures have failed to respond to conventional physiotherapy


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 23 - 23
1 Aug 2013
Ellapparadja P
Full Access

Torus (Buckle) fractures of distal radius are common in children and form a major workload of any fracture clinic. They are usually stable and do not displace. Recent evidence has shown that these fractures can be safely treated in a futura splint. In UK, many of the hospitals are still treating these patients with full plaster. Bringing back these patients to fracture clinic for plaster removal means more workload and places more financial burden in the NHS. Our study is a completed audit cycle where we successfully implemented treatment with futura splint. Over a period of 6 months, 25 torus fractures were diagnosed & treated in A/E back slab. Mean age was 8.24 (Range: 3–12 yrs). Most common MOI was fall on outstretched hand. All cases had presented to A/E within 24 hours. 5 were given futura splint at the fracture clinic. 21 cases received full plaster. They were seen back in clinic in 3–4 weeks for plaster removal. After this audit was presented, we started treating these fractures with futura splint. Reauditing 6 months later revealed that of 31 cases, we had successfully treated 28 with Futura splint. 2 were treated with plaster on parent's insistence. The remaining one was treated in plaster as we could not fit a futura splint. There were no problems reported with futura splint. By definition, torus fractures are stable. The major problem with these fractures lies in the correct diagnosis. We have treated this fracture successfully with futura splint. Recent papers have shown that every patient treated with futura splint saves nearly £53 when compared to plaster treatment. Implementing this treatment has reduced plaster related problems. We hope this audit will help in changing practice in other hospitals in NHS


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_19 | Pages 41 - 41
1 Dec 2014
Maqungo S Allen J Carrara H Roche S Rueff N
Full Access

Objectives:. To measure compliance with the Trauma Unit guideline relating to the early application of the Thomas splint in patients with a femur shaft fracture on clinical examination. Design:. Retrospective review of clinical and radiological records of patients presenting from 01 January 2012 to 31 December 2012 at a Level 1 Trauma Unit. Patients:. We included all patients with femur shaft fractures independently of their mechanism of injury. Exclusion criteria were: ipsilateral fracture of the lower limb, neck and supracondylar fractures, pathological, periprosthetic and incomplete fractures. The database available for review included demographic information, mechanism of injury, side injured, surgical procedure and time when a radiological study (Lodox and/or x-ray) was performed. Outcome measures:. Primary outcome measure was the application of a Thomas splint before the first radiological examination was performed. Secondary outcome measure was the increase in patients immobilized with a Thomas splint before their second radiological examination was performed. Results:. We identified 160 fractures, 107 (66.9%) had a femur or pelvis x-ray as the first radiological exam. In 44 (41.1%) of these fractures, a Thomas splint had already been applied. Of the 160 fractures, 53 (33.1%) had a Lodox as first radiological examination. In 16 (30.2%) of these fractures, a Thomas splint had already been applied. The remaining 37 fractures where no Thomas splint was applied prior to the Lodox had been immobilized with either a different type of splint (backslab or Kramer wires) or not immobilized at all. Of these “incorrectly” immobilized or not immobilized fractures, 17 (45.9%) were then correctly immobilized with a Thomas splint prior to the x-ray (x-ray as second radiological exam). Conclusion:. Out of 160 fractures, 60 were immobilized with a Thomas splint prior to the first radiological examination, corresponding to a 37.5% compliance rate with internal guidelines


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_II | Pages 197 - 197
1 Jul 2002
Lough L Mackie A Upton J Wallace W Neumann L
Full Access

Thermal shrinkage of the shoulder capsule requires postoperative joint immobilisation with the humeral head centred in the glenoid fossa for optimal proprioceptive recovery. Routinely applied commercial slings hold the arm internally rotated and lengthen the posterior capsule. The aim of our study was to develop and test the clinical effectiveness of a splint that would maintain the shoulder in an optimal position of neutral rotation after posterior capsular shrinkage. To our knowledge, no splint has been described for this purpose. We developed a new design fabricating the splint using thermoplastic material. The design was then modified to ensure ease of fitting and patient comfort. The custom-made splint is fashioned preoperatively and fitted in the operating room after the dressings are applied. Our study group consisted of 18 cases of multidirectional or posterior shoulder instability who were splinted for a period of three weeks after thermal capsular shrinkage. The comfort and compliance of the splint were assessed using a patient questionnaire. Constant scores for the study group were retrospectively compared with a similar patient group managed with a ‘polysling’


The Bone & Joint Journal
Vol. 105-B, Issue 2 | Pages 209 - 214
1 Feb 2023
Aarvold A Perry DC Mavrotas J Theologis T Katchburian M

Aims. A national screening programme has existed in the UK for the diagnosis of developmental dysplasia of the hip (DDH) since 1969. However, every aspect of screening and treatment remains controversial. Screening programmes throughout the world vary enormously, and in the UK there is significant variation in screening practice and treatment pathways. We report the results of an attempt by the British Society for Children’s Orthopaedic Surgery (BSCOS) to identify a nationwide consensus for the management of DDH in order to unify treatment and suggest an approach for screening. Methods. A Delphi consensus study was performed among the membership of BSCOS. Statements were generated by a steering group regarding aspects of the management of DDH in children aged under three months, namely screening and surveillance (15 questions), the technique of ultrasound scanning (eight questions), the initiation of treatment (19 questions), care during treatment with a splint (ten questions), and on quality, governance, and research (eight questions). A two-round Delphi process was used and a consensus document was produced at the final meeting of the steering group. Results. A total of 60 statements were graded by 128 clinicians in the first round and 132 in the second round. Consensus was reached on 30 out of 60 statements in the first round and an additional 12 in the seond. This was summarized in a consensus statement and distilled into a flowchart to guide clinical practice. Conclusion. We identified agreement in an area of medicine that has a long history of controversy and varied practice. None of the areas of consensus are based on high-quality evidence. This document is thus a framework to guide clinical practice and on which high-quality clinical trials can be developed. Cite this article: Bone Joint J 2023;105-B(2):209–214


Bone & Joint Open
Vol. 3, Issue 9 | Pages 726 - 732
16 Sep 2022
Hutchison A Bodger O Whelan R Russell ID Man W Williams P Bebbington A

Aims. We introduced a self-care pathway for minimally displaced distal radius fractures, which involved the patient being discharged from a Virtual Fracture Clinic (VFC) without a physical review and being provided with written instructions on how to remove their own cast or splint at home, plus advice on exercises and return to function. Methods. All patients managed via this protocol between March and October 2020 were contacted by a medical secretary at a minimum of six months post-injury. The patients were asked to complete the Patient-Rated Wrist Evaluation (PRWE), a satisfaction questionnaire, advise if they had required surgery and/or contacted any health professional, and were also asked for any recommendations on how to improve the service. A review with a hand surgeon was organized if required, and a cost analysis was also conducted. Results. Overall 71/101 patients completed the telephone consultation; no patients required surgery, and the mean and median PRWE scores were 23.9/100 (SD 24.9) and 17.0/100 (interquartile range (IQR) 0 to 40), respectively. Mean patient satisfaction with treatment was 34.3/40 (SD 9.2), and 65 patients (92%) were satisfied or highly satisfied. In total there were 16 contact calls, 12 requests for a consultant review, no formal complaints, and 15 minor adjustment suggestions to improve patient experience. A relationship was found between intra-articular injuries and lower patient satisfaction scores (p = 0.025), however no relationship was found between PRWE scores and the nature of the fracture. Also, no relationship was found between the type of immobilization and the functional outcome or patient satisfaction. Cost analysis of the self-care pathway V traditional pathway showed a cost savings of over £13,500 per year with the new self-care model compared to the traditional model. Conclusion. Our study supports a VFC self-care pathway for patients with minimally displaced distal radius fractures. The pathway provides a good level of patient satisfaction and function. To improve the service, we will make minor amendments to our patient information sheet. Cite this article: Bone Jt Open 2022;3(9):726–732


The Journal of Bone & Joint Surgery British Volume
Vol. 52-B, Issue 3 | Pages 535 - 539
1 Aug 1970
Povey RW

1. The principle of the vacuum splint is described. 2. A simple, cheap operating splint has been found useful to replace sandbags and other supports. 3. Applications to commonly practised orthopaedic operations are discussed


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 578 - 578
1 Nov 2011
Howard AW Willan A Boutis K
Full Access

Purpose: In skeletally immature children with acceptably angulated (< = 15 degrees angular deformity at presentation) distal radius and/or ulnar fractures, to determine if a pre-fabricated wrist splint is at least as effective as a cast. The primary outcome was recovery of physical function six weeks after the injury as measured by the validated Activities Scale for Kids. Secondary objectives included determining differences in angulation of fracture, wrist range of motion, wrist strength, pain with movement, return to baseline activities, and patient preferences at six weeks. Method: A randomized controlled, non-inferiority, single (evaluator) blinded, single-centre trial in a tertiary care pediatric emergency department. Minimal required sample size of 76 patients with was based on testing the null hypothesis (H0) that the brace is 7% less effective at the 2.5% level. Physical function was tested by a t-test for a non-zero difference. For the other outcomes, proportions and means were compared with the Fisher Exact and Student s t-test, respectively. Results: Of the 100 randomized patients, 3 were excluded due to non-eligibility on radiographic review. 93 of the 97 completed full clinical, radiographic, and patient determined followup. ASK scores at six weeks were 92.8 in the splint group and 91.4 in the cast group, neither clinically nor statistically significantly different. Among patients treated in a cast, the average angular deformity at followup was 11.0 degrees and compared with an average of 6.6 degrees angulation among patients treated in a splint (p=.02, t-test). These groups were equal at baseline, with an average of 7.5 degrees of angulation in the cast group and 6.7 degrees in the splint group. Complications did not differ between groups, nor did range of motion with the exception that pronation was slightly better (84 versus 74 degrees) in the splint group at the end of treatment. No patient required any operative procedure. Parents preferred splinting over casting (p< 0.001) and children preferred splinting over casting (p=0.028). Conclusion: Splinting was non-inferior to casting, and in fact may be superior to casting, for maintaining the position of a minimally displaced distal radial metaphyseal fracture. Significance: The benefits of splinting over casting have been previously established for undisplaced distal radius and ulnar fractures (Plint), this is the first study which extends these benefits to the large group of children with minimally displaced distal radius fractures. Splint treatment simplifies care for children, reduces cost, and improves short term outcomes


The Journal of Bone & Joint Surgery British Volume
Vol. 72-B, Issue 3 | Pages 460 - 463
1 May 1990
Yamamoto H Furuya K

We treated 91 congenital club feet in 59 children using a modified Denis Browne splint, and followed them for an average of 6 years and 3 months. The modified splint has an aluminium crossbar holding a pair of plastic shoe inserts moulded into corrected positions, and its use was started in children whose ages ranged from four weeks to nine months. Operation was later required in only 31 feet in 20 children. We have reviewed the other 60 feet in 39 children treated by splintage alone. All 60 feet had excellent or good function and from radiographic assessment, equinus, adduction, varus and cavus deformities had all been well corrected. Our results show that the modified splint can give good results


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 42 - 42
1 Mar 2009
Delgado-Martinez A Fernandez-Bisbal P Reyes-Sanchez S Obrero D
Full Access

Introduction and objectives: The most commonly used treatment for extraarticular fractures of distal radius is closed reduction and maintenance of reduction in a cast. Two types of casts are used: plaster splint for 7–10 days and later exchanged to a circular cast and the use of circular cast immediately. The objective of this work is to compare both types of treatment in terms of ability to achieve reduction and to maintain it during healing. Methods: A prospective, randomized and blinded study was designed. To date, 21 patients enrolled the study. Informed consent was given. The inclusion criteria were: older than 35 years, extraarticular distal radius fracture sustained less than 24 hours before and not previously treated. Exclusion criteria included previous injury in the same wrist, open fracture, and not compliance with the protocol. After intrafocal anesthesia with mepivacaine 1%, fracture was reduced under traction and immobilized in a dorsal short plaster splint (splint group) or a circular short plaster cast (circular group) randomly. After 10 days of immobilization, the plaster splint was changed to a circular short plaster cast. AP and lateral X-Rays were taken before reduction, after reduction, after 10 days (before changing cast), and at 21 days. Volar inclination of lunate fossa on the lateral X-Ray was obtained. On the AP proyection, the radial inclination and radial length was measured. Complications were recorded. Data was analysed through ANOVA between groups. Results: When comparing X-rays before and after reduction, the volar inclination of the lunate fossa on lateral projection changed from −21,4° to 8,60° (30° change) after reduction in splint group and from −15,22° to 1,78° (17° change) in circular group (p< 0.05). The other comparisons were N.S. When comparing after reduction and 10 days later, the radial inclination changed from 20,20° to 18,80° (1,40° change) in the splint group and from 20,89° to 20,44 (0,44° change) in the circular group (p< 0.05). Other comparisons were N.S. No differences were found between 10 days and 21 days in any X-Ray parameter. No complications were found. Conclusions: A better reduction was achieved with the plaster splint method in the immediate X-Ray control. Nevertheless, reduction was better maintained during the first 10 days with the circular plaster cast method


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 38 - 38
1 May 2012
A. H A. W K. B
Full Access

Purpose. To determine, in skeletally immature children with acceptably angulated (< = 15 degrees deformity at presentation) distal radius fractures, if a pre-fabricated wrist splint is at least as effective as a cast. Methods. A randomised controlled, non-inferiority, single blinded, single-centre trial was performed. The primary outcome was physical function at six weeks. Secondary outcomes included angulation, wrist range of motion, strength, pain, and patient preferences. Results. 93 of 97 randomised patients completed full follow-up. ASK scores at six weeks were 92.8 in the splint group and 91.4 in the cast group. Among patients treated in a cast, the average angular deformity at follow-up was 11.0 degrees, compared with an average of 6.6 degrees angulation among patients treated in a splint (p=0.02, t-test). Complications did not differ between groups, nor did range of motion. Conclusion. Splinting was not inferior to casting, and in fact may be superior to casting, for maintaining the position of a minimally displaced distal radial metaphyseal fracture. Significance. The benefits of splinting over casting have been previously established for undisplaced distal radius and ulnar fractures (Plint), this is the first study which extends the benefits of splinting to the large group of children with minimally displaced distal radius fractures


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 2 | Pages 322 - 327
1 Mar 1993
Seror P

Twenty-two patients with ulnar nerve palsy at the elbow, confirmed by electromyography, were treated by a night splint which prevented flexion of the elbow beyond 60 degrees. The splint was worn all night regularly for at least six months. At a mean follow-up of 11.3 months, 17 patients had clinical and electromyographic assessment and five were contacted by telephone. There was improvement in the symptoms in every patient, including three who had failed to respond to surgical decompression. There was electromyographic improvement in 16 of the 17 patients re-examined at follow-up. The mean improvement in motor nerve conduction velocity was 6.5 m/s and in sensory nerve conduction velocity 9.5 m/s. The efficacy of this treatment suggests that nocturnal elbow flexion is an important cause of ulnar nerve lesions at the elbow