header advert
Results 1 - 20 of 6446
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 2 | Pages 212 - 220
1 Feb 2022
Fishley WG Selvaratnam V Whitehouse SL Kassam AM Petheram TG

Aims. Femoral cement-in-cement revision is a well described technique to reduce morbidity and complications in hip revision surgery. Traditional techniques for septic revision of hip arthroplasty necessitate removal of all bone cement from the femur. In our two centres, we have been using a cement-in-cement technique, leaving the distal femoral bone cement in selected patients for septic hip revision surgery, both for single and the first of two-stage revision procedures. A prerequisite for adoption of this technique is that the surgeon considers the cement mantle to be intimately fixed to bone without an intervening membrane between cement and host bone. We aim to report our experience for this technique. Methods. We have analyzed patients undergoing this cement-in-cement technique for femoral revision in infection, and present a consecutive series of 89 patients. Follow-up was undertaken at a mean of 56.5 months (24.0 to 134.7) for the surviving cases. Results. Seven patients (7.9%) required further revision for infection. Ten patients died of causes unrelated to their infection before their two-year review (mean 5.9 months; 0.9 to 18.6). One patient was lost to follow-up at five months after surgery, and two patients died of causes unrelated to their hip shortly after their two-year review was due without attending. Of the remaining patients, 69 remained infection-free at final review. Radiological review confirms the mechanical success of the procedure as previously described in aseptic revision, and postoperative Oxford Hip Scores suggest satisfactory functional outcomes. Conclusion. In conclusion, we found that retaining a well-fixed femoral cement mantle in the presence of infection and undertaking a cement-in-cement revision was successful in 82 of the patients (92.1%) in our series of 89, both in terms of eradication of infection and component fixation. These results are comparable to other more invasive techniques and offer significant potential benefits to the patient. Cite this article: Bone Joint J 2022;104-B(2):212–220


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_11 | Pages 29 - 29
1 Dec 2020
Thahir A Lim JA West C Krkovic M
Full Access

Intro. Calcium sulphate (CS) is a recent alternative for antibiotic elution in infected bones and joints. The purpose of this study is to evaluate the use of antibiotic impregnated calcium sulphate (AICS) beads in the management of infected tibia and femur, with regards to patient outcomes and complication rates (including reinfection rate, remission rate and union rate). Methods. Searches of AMED, CINAHL, EMBASE, EMCARE, Medline, PubMed and Google Scholar were conducted in June 2020, with the mesh terms: “Calcium sulphate beads” or “Calcium sulfate beads” or “antibiotic beads” or “Stimulan” AND “Bone infection” or “Osteomyelitis” or “Debridement” AND “Tibia” or “Femur”. Risk of bias was assessed using the Risk of Bias in Non-randomised Studies of interventions (ROBINS-i) tool, and quality assessed via the Grading of Recommendations, Assessment, Development and Evaluation (GRADE) criteria. Results. Out of 105 relevant papers, 11 met the inclusion criteria for data extraction. Total infection recurrence rate was 6.8% (range 3.2 – 11.9%, n = 295), which was significantly lower (p < 0.001) than that of polymethylmethacrylate (PMMA; 19.6%, n = 163). Complication rates varied. The main issue regarding AICS use was wound drainage (7.9 – 33.3%), which was considerably higher in studies involving treatment of the tibia only. Studies using PMMA did not experience this issue, but there were a few incidences of superficial pin tract infection following surgery. Conclusions. AICS was consistently effective at infection eradication, despite variation in causative organism and location of bead placement. Additionally, PMMA has many inconvenient properties. AICS is therefore an attractive alternative as an adjunct in treatment of infected tibia and femur. Wound drainage rate varied and was higher in studies regarding tibial cases alone


The Bone & Joint Journal
Vol. 98-B, Issue 6 | Pages 846 - 850
1 Jun 2016
Hoskins W Sheehy R Edwards ER Hau RC Bucknill A Parsons N Griffin XL

Aims. Fractures of the distal femur are an important cause of morbidity. Their optimal management remains controversial. Contemporary implants include angular-stable anatomical locking plates and locked intramedullary nails (IMNs). We compared the long-term patient-reported functional outcome of fixation of fractures of the distal femur using these two methods of treatment. Patients and Methods. A total of 297 patients were retrospectively identified from a State-wide trauma registry in Australia: 195 had been treated with a locking plate and 102 with an IMN. Baseline characteristics of the patients and their fractures were recorded. Health-related quality-of-life, functional and radiographic outcomes were compared using mixed effects regression models at six months and one year. Results. There was a clinically relevant and significant difference in quality-of-life at six months in favour of fixation with an IMN (mean difference in EuroQol-5 Dimensions Score (EQ-5D) = 0.12; 95% CI 0.02 to 0.22; p = 0.025). There was weak evidence that this trend continued to one year (mean difference EQ-5D = 0.09; 95% CI -0.01 to 0.19; p = 0.073). There was a significant although very small reduction in angular deformity using an IMN (mean difference -1.02; 95% CI -1.99 to -0.06; p = 0.073). There was no evidence that there was a difference in any other outcomes at any time point. Take home message: IMN may be a superior treatment compared with anatomical locking plates for fractures of the distal femur. These findings are concordant with other data from pilot randomised studies which favour treatment of these fractures with an IMN. This study strongly supports the need for a definitive randomised trial. Cite this article: Bone Joint J 2016;98-B:846–50


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 741 - 748
1 Jun 2015
Bonnin MP Neto CC Aitsiselmi T Murphy CG Bossard N Roche S

The aim of this study was to investigate the relationship between the geometry of the proximal femur and the incidence of intra-operative fracture during uncemented total hip arthroplasty (THA). We studied the pre-operative CT scans of 100 patients undergoing THA with an uncemented femoral component. We measured the anteroposterior and mediolateral dimensions at the level of division of the femoral neck to calculate the aspect ratio of the femur. Wide variations in the shape of the femur were observed, from round, to very narrow elliptic. The femurs of women were narrower than those of men (p < 0.0001) and small femurs were also narrower than large ones. Patients with an intra-operative fracture of the calcar had smaller and narrower femurs than those without a fracture (p < 0.05) and the implanted Corail stems were smaller in those with a fracture (mean size 9 vs 12, p < 0.0001). The variability of the shape of the femoral neck at the level of division contributes to the understanding of the causation of intra-operative fractures in uncemented THA. Cite this article: Bone Joint J 2015;97-B:741–8


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 378 - 386
1 Mar 2018
Campanacci DA Totti F Puccini S Beltrami G Scoccianti G Delcroix L Innocenti M Capanna R

Aims. After intercalary resection of a bone tumour from the femur, reconstruction with a vascularized fibular graft (VFG) and massive allograft is considered a reliable method of treatment. However, little is known about the long-term outcome of this procedure. The aims of this study were to determine whether the morbidity of this procedure was comparable to that of other reconstructive techniques, if it was possible to achieve a satisfactory functional result, and whether biological reconstruction with a VFG and massive allograft could achieve a durable, long-lasting reconstruction. Patients and Methods. A total of 23 patients with a mean age of 16 years (five to 40) who had undergone resection of an intercalary bone tumour of the femur and reconstruction with a VFG and allograft were reviewed clinically and radiologically. The mean follow-up was 141 months (24 to 313). The mean length of the fibular graft was 18 cm (12 to 29). Full weight-bearing without a brace was allowed after a mean of 13 months (seven to 26). Results. At final follow-up, the mean Musculoskeletal Tumor Society Score of 22 evaluable patients was 94% (73 to 100). Eight major complications, five fractures (21.7%), and three nonunions (13%) were seen in seven patients (30.4%). Revision-free survival was 72.3% at five, ten, and 15 years, with fracture and nonunion needing surgery as failure endpoints. Overall survival, with removal of allograft or amputation as failure endpoints, was 94.4% at five, ten, and 15 years. Discussion. There were no complications needing surgical revision after five years had elapsed from surgery, suggesting that the mechanical strength of the implant improves with time, thereby decreasing the risk of complications. In young patients with an intercalary bone tumour of the femur, combining a VFG and massive allograft may result in a reconstruction that lasts a lifetime. Cite this article: Bone Joint J 2018;100-B:378–86


The Bone & Joint Journal
Vol. 97-B, Issue 6 | Pages 842 - 846
1 Jun 2015
Bennett PM Sargeant ID Myatt RW Penn-Barwell JG

This is a retrospective study of survivors of recent conflicts with an open fracture of the femur. We analysed the records of 48 patients (48 fractures) and assessed the outcome. The median follow up for 47 patients (98%) was 37 months (interquartile range 19 to 53); 31 (66%) achieved union; 16 (34%) had a revision procedure, two of which were transfemoral amputation (4%). The New Injury Severity Score, the method of fixation, infection and the requirement for soft-tissue cover were not associated with a poor outcome. The degree of bone loss was strongly associated with a poor outcome (p = 0.00204). A total of four patients developed an infection; two with S. aureus, one with E. coli and one with A. baumannii. This study shows that, compared with historical experience, outcomes after open fractures of the femur sustained on the battlefield are good, with no mortality and low rates of infection and late amputation. The degree of bone loss is closely associated with a poor outcome. Cite this article: Bone Joint J 2015;97-B:842–6


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 136 - 136
1 May 2011
Mitkovic M Milenkovic S Micic I Desimir M Mitkovic M
Full Access

Introduction: Increasing number of osteoporotic fractures of the femur, especially upper part of the femur creates everyday problem of health services. Treatment of these fractures has been improving markedly during the past 25 years. DHS, gamma nail and some other implants are very useful in everyday surgery. However some of complications still can not be resolved like cut out. Osteoporotic fractures in subtrochanteric area represent even bigger challenging. Diaphyseal fractures are also difficult to be treated. The main problem is quality of osteoporotic bone. Plate with parallel screws doesn’t provide reliable fixation. Intramedulary nails, because of wide channel in distal femur area also don’t provide desirable fixation stability. Material and Method: We analysed results of using of one new device: selfdynamisable internal fixator (SIF) in the series of 389 patients treated because of upper femur fractures. That device has possibilities of spontaneous dynamisation in two axes: along the femoral neck axis and along the diaphyseal axis. Spontaneous dynamisation in the diaphyseal axis is very important if diaphyseal or subrtochanteric fracture or comminuted fracture of the upper femur with subtrochanteric extension treated. For activation of axial dynamisation it not necessary to do any action from outside the body. This feature is activated spontaneously if there is no progress in fracture union within 6–8 weeks. This device provides three-dimensional fixation using clams and rod onto the lateral surface of the femur. The age of patients was from 59 to 87 years. This internal fixator is applied using minimally invasive method – by one or two small incisions. Results: During the treatment it has been confirmed working of self-dynamisation concept. Spontaneous dynamisation in the long axis of the femur has been proven in 21% of patients with subtrochanteric and diaphyseal fractures and it has been proven radiologically that sliding happened between 1–4 mm (average 2.5 mm). Such dynamisation together with 3D configuration of screws resulted in relatively quick fracture healing. Follow up was 19 months (6–60). Altogether 97.6% fractures healed within normal healing time. There were 1 infection, 2 cut out, 1 mechanical complication, 4 delay unions and one non-union. Conclusion: According to results obtained, it can bee concluded that new biological internal fixator is suitable for minimally invasive technique, without opening of fracture site


The Bone & Joint Journal
Vol. 95-B, Issue 8 | Pages 1144 - 1148
1 Aug 2013
Sternheim A Saidi K Lochab J O’Donnell PW Eward WC Griffin A Wunder JS Ferguson P

We investigated the clinical outcome of internal fixation for pathological fracture of the femur after primary excision of a soft-tissue sarcoma that had been treated with adjuvant radiotherapy. A review of our database identified 22 radiation-induced fractures of the femur in 22 patients (seven men, 15 women). We noted the mechanism of injury, fracture pattern and any complications after internal fixation, including nonunion, hardware failure, secondary fracture or deep infection. The mean age of the patients at primary excision of the tumour was 58.3 years (39 to 86). The mean time from primary excision to fracture was 73.2 months (2 to 195). The mean follow-up after fracture fixation was 65.9 months (12 to 205). Complications occurred in 19 patients (86%). Nonunion developed in 18 patients (82%), of whom 11 had a radiological nonunion at 12 months, five a nonunion and hardware failure and two an infected nonunion. One patient developed a second radiation-associated fracture of the femur after internal fixation and union of the initial fracture. A total of 13 patients (59%) underwent 24 revision operations. Internal fixation of a pathological fracture of the femur after radiotherapy for a soft-tissue sarcoma has an extremely high rate of complication and requires specialist attention. Cite this article: Bone Joint J 2013;95-B:1144–8


The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1378 - 1384
1 Oct 2014
Weiser L Korecki MA Sellenschloh K Fensky F Püschel K Morlock MM Rueger JM Lehmann W

It is becoming increasingly common for a patient to have ipsilateral hip and knee replacements. The inter-prosthetic (IP) distance, the distance between the tips of hip and knee prostheses, has been thought to be associated with an increased risk of IP fracture. Small gap distances are generally assumed to act as stress risers, although there is no real biomechanical evidence to support this. The purpose of this study was to evaluate the influence of IP distance, cortical thickness and bone mineral density on the likelihood of an IP femoral fracture. A total of 18 human femur specimens were randomised into three groups by bone density and cortical thickness. For each group, a defined IP distance of 35 mm, 80 mm or 160 mm was created by choosing the appropriate lengths of component. The maximum fracture strength was determined using a four-point bending test. The fracture force of all three groups was similar (p = 0.498). There was a highly significant correlation between the cortical area and the fracture strength (r = 0.804, p <  0.001), whereas bone density showed no influence. This study suggests that the IP distance has little influence on fracture strength in IP femoral fractures: the thickness of the cortex seems to be the decisive factor. Cite this article: Bone Joint J 2014;96-B:1378–84


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 6 | Pages 836 - 841
1 Jun 2012
Frisoni T Cevolani L Giorgini A Dozza B Donati DM

We retrospectively reviewed 101 consecutive patients with 114 femoral tumours treated by massive bone allograft at our institution between 1986 and 2005. There were 49 females and 52 males with a mean age of 20 years (4 to 74). At a median follow-up of 9.3 years (2 to 19.8), 36 reconstructions (31.5%) had failed. The allograft itself failed in 27 reconstructions (24%).

Mechanical complications such as delayed union, fracture and failure of fixation were studied. The most adverse factor on the outcome was the use of intramedullary nails, followed by post-operative chemotherapy, resection length > 17 cm and age > 18 years at the time of intervention. The simultaneous use of a vascularised fibular graft to protect the allograft from mechanical complications improved the outcome, but the use of intramedullary cementing was not as successful.

In order to improve the strength of the reconstruction and to advance the biology of host–graft integration, we suggest avoiding the use of intramedullary nails and titanium plates, but instead using stainless steel plates, as these gave better results. The use of a supplementary vascularised fibular graft should be strongly considered in adult patients with resection > 17 cm and in those who require post-operative chemotherapy.


There is a strong association between the presence of a calcar collar on a cementless stem and a reduced risk of revision surgery for periprosthetic fracture of the femur (PFF). A medial calcar collar may act to reduce relative movement between the implant and femur during PFF, through calcar-collar contact (CCC). The aims were:. Estimate the effect of CCC on periprosthetic fracture mechanics. Estimate the effect of initial calcar-collar separation on the likelihood of CCC. Three groups of six composite femurs were implanted with a fully coated collared cementless femoral stem. Neck resection differed between groups (group 1 = no additional resection, group 2 = 3mm additional resection, group 3 = 6mm additional resection). PFF were simulated using a previously published technique. Fracture torque and rotational displacement were measured and torsional stiffness and rotational work prior to fracture were estimated. Results between trials where CCC did and did not occur where compared using Mann-Whitney U tests. Logistic regression estimated the odds (OR) of failing with 95% confidence interval (CI) to achieve CCC for a given initial separation. Where CCC occurred fracture torque was greater (47.33 [41.03 to 50.45] Nm versus 38.26 [33.70 to 43.60] Nm, p= 0.05) and torsional stiffness was greater (151.38 [123.04 to 160.42] rad.Nm. −1. versus 96.86 [84.65 to 112.98] rad.Nm. −1. , p <0.01). CCC was occurred in all cases in group one, 50% in group two and 0% in group three. OR of failure to obtain CCC increased 3.8 fold (95% CI 1.6 to 30.2, p <0.05) for each millimetre of separation. Resistance to fracture and construct stiffness increased when a the collar made contact with the calcar prior to fracture and the chances of contact decrease with increasing initial separation at the time of implantation. Surgeons should aim to achieve a calcar-collar distance of less than 1mm following implantation to ensure CCC and to reduce the risk of fracture


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 19 - 19
1 Mar 2021
Lamb J Coltart O Adekanmbi I Stewart T Pandit H
Full Access

Abstract. Objective. To estimate the effect of calcar collar contact on periprosthetic fracture mechanics using a collared fully coated cementless femoral stem. Methods. Three groups of six composite femurs were implanted with a fully coated collared cementless femoral stem. Neck resection was increased between groups (group 1 = normal, group 2 = 3mm additional, group 3 = 6mm additional), to simulate failure to obtain calcar collar contact. Periprosthetic fractures of the femur were simulated using a previously published technique. Fracture torque and rotational displacement were measured and torsional stiffness and rotational work prior to fracture were estimated. High speed video recording identified if collar to calcar contact (CCC) occurred. Results between trials where calcar contact did and did not occur where compared using Mann-Whitney U tests. Results. Where CCC occurred versus where no CCC occurred, fracture torque was greater (47.33 [41.03 to 50.45] Nm versus 38.26 [33.70 to 43.60] Nm, p= 0.05), Rotational displacement was less (0.29 [0.27 to 0.39] rad versus 0.37 [0.33 to 0.49] rad, p= 0.07), torsional stiffness was greater (151.38 [123.04 to 160.42] rad. Nm-1 versus 96.86 [84.65 to 112.98] rad.Nm-1, p <0.01) and rotational work was similar (5.88 [4.67, 6.90] J versus 5.31 [4.40, 6.56] J, p= 0.6). Conclusions. Resistance to fracture and construct stiffness increased when a collared cementless stem made contact with the femoral calcar prior to fracture. These results demonstrate that calcar-collar contact and not a calcar collar per se, is crucial to maximising the protective effect of a medial calcar collar on the risk of post-operative periprosthetic fractures of the femur. Declaration of Interest. (a) fully declare any financial or other potential conflict of interest


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 371 - 371
1 Dec 2013
Wright S Boymans TA Miles T Grimm B Kessler O
Full Access

Introduction. The human body is a complex and continually adapting organism. It is theorised that the morphology of the proximal femur is closely related to that of the distal femur. Patients that have abnormal anatomy in the proximal femur, such as a high femoral neck anteversion angle, may have abnormal anatomy in the distal femur to overcome proximal differences. This phenomenon is of key interest when performing Total Hip Replacement (THR) or Total Knee Replacement (TKR) surgery. The current design and placement of existing hip and knee implants does not account for any correlation between the anatomical parameters of the proximal and distal femur, where bone anatomy may have adapted to compromise for abnormalities. A preliminary study of 21 patients has been carried out to assess the relationship between the proximal and distal femur. The difficulties in defining and measuring key anatomical parameters on the femur have been widely discussed in the literature [1] due to its complex three dimensional geometry. Using CT scans of healthy octogenarians, it was possible to mark key anatomical landmarks which could be used to define various anatomical axes throughout the femur. Correlation analyses could then be carried out on these parameters to assess the relationship between proximal and distal femur morphology. Methods. Each femur was initially realigned along the mechanical axis (MA); defined by joining the centre of the femoral head (FHC) to the centre of the intercondylar notch (INC) [2]. All anatomical landmarks were then identified using the Materialise Mimics v12 software (Figure 1 and 2) and exported into Microsoft Excel for analysis. Key anatomical parameters which were derived from these landmarks included the femoral neck axis (FNA), femoral neck anteversion angle (FNAA) [1–4], condylar twist angle, clinical transepicondylar axis (TEA), trochlea sulcus angle and medial and lateral trochlea twist. A correlation analysis was carried out on SPSS Statistics v20 (IBM) to assess the relationship between proximal and distal anatomical parameters. Results. The correlation analysis displayed a positive linear correlation between the FNAA and the clinical TEA (adjusted R squared = 0.471, p < 0.001) indicating that an abnormally high FNAA is correlated with a higher TEA angle (Figure 3). No strong relationship was found between the FNAA and the additional distal parameters compared, in particular there was no trend between the FNAA and the geometry of the trochlea as measured by the sulcus angle and trochlea twist. Discussion. The morphology of the distal femur seems to be at least partially correlated with the proximal femur and the relationship should be studied further to assess any potential effect on THA and TKA surgery. An extension of this study should assess an increased patient sample size and further anatomical parameters


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 3 - 3
1 Apr 2022
Bari M
Full Access

Introduction. Infected big gap non-union of femur and tibia are difficult to treatment because of infection, bone loss, shortening, poor sift tissue over and deformity. Step by step management and definitive treatment by Ilizarov fixator was achieved in our cases. Materials and Methods. A long defect which is more than 10cm in femur and tibia because of infection and gap, tumor resection, traumatic loss, which is very difficult to treat by conventional method and that's why we treated that type defect by Tibialization of fibula with Ilizarov technique. Management of infected big gap non-union of the femur include debridement and bone transport by Ilizarov technique by using Ilizarov fixator we can correct deformities, regenerate new bone without bone grafting, correct LLD and patient can weight bear during the course of treatment. We retrospectively reviewed records of 246 consecutive patients who underwent distraction osteogenesis using Ilizarov compression-distraction device for infected big gap INU of femur and tibia from 2000 to 2020. Results. All healed with the application of Ilizarov fixator, 5 needed reapplications of Ilizarov to achieve 100% union. 210 were excellent, 25 good and 6 were fair by ASAMI criteria. Mean Ilizarov duration was 366 days (130–250). Mean 8.2 cm length was achieved in the regenerate. Conclusions. A well plan step by step Ilizarov technique to cover infected gap non-union of femur and tibia is an excellent method in challenging cases. Excellent results cannot be achieved with conventional methods but can be easily achieved with Ilizarov technique within 1–2 years


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1174 - 1179
1 Oct 2022
Jamshidi K Bagherifard A Mirzaei A

Aims. Osteoarticular reconstruction of the distal femur in childhood has the advantage of preserving the tibial physis. However, due to the small size of the distal femur, matching the host bone with an osteoarticular allograft is challenging. In this study, we compared the outcomes and complications of a resurfaced allograft-prosthesis composite (rAPC) with those of an osteoarticular allograft to reconstruct the distal femur in children. Methods. A retrospective analysis of 33 skeletally immature children with a malignant tumour of the distal femur, who underwent resection and reconstruction with a rAPC (n = 15) or osteoarticular allograft (n = 18), was conducted. The median age of the patients was ten years (interquartile range (IQR) 9 to 11) in the osteoarticular allograft group and nine years (IQR 8 to 10) in the rAPC group (p = 0.781). The median follow-up of the patients was seven years (IQR 4 to 8) in the osteoarticular allograft group and six years (IQR 3 to 7) in the rAPC group (p = 0.483). Limb function was evaluated using the Musculoskeletal Tumor Society (MSTS) score. Results. At final follow-up, the knee was unstable in 9/18 patients (50%) in the osteoarticular allograft group and 2/15 patients (13%) in the rAPC group (p = 0.026). The median range of motion (ROM) of the knee was 117° (IQR 115° to 120°) in the osteoarticular allograft group and 100° (IQR 95° to 105°) in the rAPC group (p < 0.001). The median MSTS score was 25 (IQR 23 to 26) in the osteoarticular allograft group and 28 (IQR 26 to 29) in the rAPC group (p = 0.007). Osteoarthritic change was detected in 11/18 patients (61%) in the osteoarticular allograft group and in 4/15 (26%) patients in the rAPC group (p = 0.048). Conclusion. In our series, a resurfaced allograft-prosthesis composite provided better knee stability and function, with a lower rate of osteoarthritis; an osteoarticular allograft was associated with better knee ROM. Cite this article: Bone Joint J 2022;104-B(10):1174–1179


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 77 - 77
1 Oct 2022
Schwarze J Daweke M Gosheger G Moellenbeck B Ackmann T Puetzler J Theil C
Full Access

Aim. Repeat revision surgery of total hip or knee replacement may lead to massive bone loss of the femur. If these defects exceed a critical amount a stable fixation of a proximal or distal femur replacement may not be possible. In these extraordinary cases a total femur replacement (TFR) may be used as an option for limb salvage. In this retrospective study we examined complications, revision free survival (RFS), amputation free survival (AFS) and risk factors for decreased RFS and AFS following a TRF in cases of revision arthroplasty with a special focus on periprosthetic joint infection (PJI). Method. We included all implantations of a TFR in revision surgery from 2006–2018. Patients with a primary implantation of a TFR for oncological indications were not included. Complications were classified using the Henderson Classification. Primary endpoints were revision of the TFR or disarticulation of the hip. The minimum follow up was 24 month. RFS and AFS were analyzed using Kaplan-Meier method, patients´ medical history was analyzed for possible risk factors for decreased RFS and AFS. Results. After applying the inclusion criteria 58 cases of a TFR in revision surgery were included with a median follow-up of 48.5 month. The median age at surgery was 68 years and the median amount of prior surgeries was 3. A soft tissue failure (Henderson Type I) appeared in 16 cases (28%) of which 13 (22%) needed revision surgery. A PJI of the TFR (Henderson Type IV) appeared in 32 cases (55%) resulting in 18 (31%) removals of the TFR and implantation of a total femur spacer. Disarticulation of the hip following a therapy resistant PJI was performed in 17 cases (29%). The overall 2-year RFS was 36% (95% confidence interval(CI) 24–48%). Patients with a Body mass Index (BMI) >30kg/m² had a decreased RFS after 24 month (>30kg/m² 11% (95%CI 0–25%) vs. <30kg/m² 50% (95%CI 34–66%)p<0.01). The overall AFS after 5 years was 68% (95%CI 54–83%). A PJI of the TFR and a BMI >30kg/m² was significantly correlated with a lower 5-year AFS (PJI 46% (95%CI 27–66%) vs no PJI 100%p<0.001) (BMI >30kg/m² 30% (95% KI 3–57%) vs. <30km/m² 85% (95% KI 73–98%)p<0.01). Conclusions. A TFR in revision arthroplasty is a valuable option for limb salvage but complications in need of further revision surgery are common. Patients with a BMI >30kg/m² should be informed regarding the increased risk for revision surgery and loss of extremity before operation


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 12 - 12
1 Apr 2022
Baumgart R
Full Access

Introduction. Fully implantable systems are used commonly only after maturity. What are indications to use fully implantable systems at the femur even in children?. Materials and Methods. Implantable lengthening nails (FITBONE) were used retrograde at the femur in minimal invasive technique to correct a limb length discrepancy of >6 cm. In 5 cases a relevant deformity was corrected in the same surgery. In all cases a final step of lengthening was planned at the femur and at the tibia with fully implantable devices at maturity. Results. 18 patients with the medium age of 10,3 years (8–14) were treated. In 17 cases the goal of lengthening was achieved without any complication. In one case of proximal femoral deficiency lengthening had to be stopped because of increasing tendency of knee joint luxation. Bone formation occurred circular around the nail in all cases. Full load bearing was possible in the average after 2,2 days/mm. No technical problems occur. In one case induced deformity in the lateral plane was observed which was corrected at the final step. At the end of treatment functional and cosmetical result was perfect in all cases. Conclusions. Fully implantable motorized distraction nails are a favorable option for lengthening and deformity correction of the femur even for children older than 10 years to correct limb length discrepancy of more than 6 cm. The treatment has a low pain level, is comfortable and nearly no scars are visible


The Bone & Joint Journal
Vol. 103-B, Issue 11 | Pages 1678 - 1685
1 Nov 2021
Abdelaziz H Schröder M Shum Tien C Ibrahim K Gehrke T Salber J Citak M

Aims. One-stage revision hip arthroplasty for periprosthetic joint infection (PJI) has several advantages; however, resection of the proximal femur might be necessary to achieve higher success rates. We investigated the risk factors for resection and re-revisions, and assessed complications and subsequent re-revisions. Methods. In this single-centre, case-control study, 57 patients who underwent one-stage revision arthroplasty for PJI of the hip and required resection of the proximal femur between 2009 and 2018 were identified. The control group consisted of 57 patients undergoing one-stage revision without bony resection. Logistic regression analysis was performed to identify any correlation with resection and the risk factors for re-revisions. Rates of all-causes re-revision, reinfection, and instability were compared between groups. Results. Patients who required resection of the proximal femur were found to have a higher all-cause re-revision rate (29.8% vs 10.5%; p = 0.018), largely due to reinfection (15.8% vs 0%; p = 0.003), and dislocation (8.8% vs 10.5%; p = 0.762), and showed higher rate of in-hospital wound haematoma requiring aspiration or evacuation (p = 0.013), and wound revision (p = 0.008). The use of of dual mobility components/constrained liner in the resection group was higher than that of controls (94.7% vs 36.8%; p < 0.001). The presence and removal of additional metal hardware (odds ratio (OR) = 7.2), a sinus tract (OR 4), ten years’ time interval between primary implantation and index infection (OR 3.3), and previous hip revision (OR 1.4) increased the risk of proximal femoral resection. A sinus tract (OR 9.2) and postoperative dislocation (OR 281.4) were associated with increased risk of subsequent re-revisions. Conclusion. Proximal femoral resection during one-stage revision hip arthroplasty for PJI may be required to reduce the risk of of recurrent or further infection. Patients with additional metalware needing removal or transcortical sinus tracts and chronic osteomyelitis are particularly at higher risk of needing proximal femoral excision. However, radical resection is associated with higher surgical complications and increased re-revision rates. The use of constrained acetabular liners and dual mobility components maintained an acceptable dislocation rate. These results, including identified risk factors, may aid in preoperative planning, patient consultation and consent, and intraoperative decision-making. Cite this article: Bone Joint J 2021;103-B(11):1678–1685


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 2 - 2
2 Jan 2024
Ditmer S Dwenger N Jensen L Ghaffari A Rahbek O
Full Access

The most important outcome predictor of Legg-Calvé-Perthes disease (LCPD) is the shape of the healed femoral head. However, the deformity of the femoral head is currently evaluated by non-reproducible, categorical, and qualitative classifications. In this regard, recent advances in computer vision might provide the opportunity to automatically detect and delineate the outlines of bone in radiographic images for calculating a continuous measure of femoral head deformity. This study aimed to construct a pipeline for accurately detecting and delineating the proximal femur in radiographs of LCPD patients employing existing algorithms. To detect the proximal femur, the pretrained stateof-the-art object detection model, YOLOv5, was trained on 1580 manually annotated radiographs, validated on 338 radiographs, and tested on 338 radiographs. Additionally, 200 radiographs of shoulders and chests were added to the dataset to make the model more robust to false positives and increase generalizability. The convolutional neural network architecture, U-Net, was then employed to segment the detected proximal femur. The network was trained on 80 manually annotated radiographs using real-time data augmentation to increase the number of training images and enhance the generalizability of the segmentation model. The network was validated on 60 radiographs and tested on 60 radiographs. The object detection model achieved a mean Average Precision (mAP) of 0.998 using an Intersection over Union (IoU) threshold of 0.5, and a mAP of 0.712 over IoU thresholds of 0.5 to 0.95 on the test set. The segmentation model achieved an accuracy score of 0.912, a Dice Coefficient of 0.937, and a binary IoU score of 0.854 on the test set. The proposed fully automatic proximal femur detection and segmentation system provides a promising method for accurately detecting and delineating the proximal femoral bone contour in radiographic images, which is necessary for further image analysis


The Bone & Joint Journal
Vol. 106-B, Issue 2 | Pages 195 - 202
1 Feb 2024
Jamshidi K Kargar Shooroki K Ammar W Mirzaei A

Aims. The epiphyseal approach to a chondroblastoma of the intercondylar notch of a child’s distal femur does not provide adequate exposure, thereby necessitating the removal of a substantial amount of unaffected bone to expose the lesion. In this study, we compared the functional outcomes, local recurrence, and surgical complications of treating a chondroblastoma of the distal femoral epiphysis by either an intercondylar or an epiphyseal approach. Methods. A total of 30 children with a chondroblastoma of the distal femur who had been treated by intraregional curettage and bone grafting were retrospectively reviewed. An intercondylar approach was used in 16 patients (group A) and an epiphyseal approach in 14 (group B). Limb function was assessed using the Musculoskeletal Tumor Society (MSTS) scoring system and Sailhan’s functional criteria. Results. At final follow-up, the mean MSTS score was 29.1 (SD 0.9) in group A and 26.7 (SD 1.5) in group B (p = 0.006). According to Sailhan’s criteria, the knee function was good and fair in 14 (87.5%) and two (12.5%) patients of group A, and eight (57.1%) and six (42.9%) patients of group B, respectively (p = 0.062). The lesion had recurred in one patient (6.2%) in group A and four patients (28.6%) in group B. Limb shortening > 1 cm was recorded in one patient (6.2%) from group A and six patients (42.8%) from group B. Joint degeneration was noted in one patient from group A and three patients from group B. Conclusion. An intercondylar approach to a chondroblastoma of the middle two-quarters of the distal femoral epiphysis results in better outcomes than a medial or lateral epiphyseal approach: specifically, better limb function, a lower rate of recurrence, and a lower rate of physeal damage and joint degeneration. Cite this article: Bone Joint J 2024;106-B(2):195–202