Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_7 | Pages 8 - 8
1 May 2019
Moriarty P Wong L Kearney D Harty J
Full Access

Revision hip arthroplasty presents a challenge in the setting of femoral bone loss. Tapered stems are susceptible to subsidence which leads to leg length inequality, hip instability and may necessitate repeat femoral revision surgery.

The purpose of this study was to compare radiographic outcomes in two modular tapered revision systems with different distal stem geometries. We sought to establish the minimum postoperative stem bi-cortical contact length that predicts subsidence for tapered stems.

This study examined revision total hip arthroplasties between 2009 and 2016 in a European university affiliated major trauma center. Modular stem A has a taper of 3 degrees whereas modular stem B has a taper of 2 degrees. Radiologic assessment compared x-rays at two time points: immediately post-surgery and most recent x-ray available at a minimum follow up of two years. Leg length discrepancy, subsidence and postoperative bi cortical contact was assessed. Descriptive summary statistics calculated clinical factors (i.e. age, gender, Paprosky classification).

122 arthroplasties were completed. Complete data was available for 112. Revisions were carried out for Paprovski grade 3a/ 3b femoral deficits. Post-operative bi-cortical contact of the proximal stem < 20mm was associated with higher subsidence rates (P = 0.047). Subsidence rates for implant A and B system were 4.27mm (0.12–25.62mm) and 3.43 mm (0.3–11.1 mm) respectively. Significant subsidence was noted in 9.8% (n=8) in implant A and 5.2%(n=2) in implant B.

We conclude that immediate postoperative bi-cortical stem contact of <20mm was associated with significantly higher subsidence rates in this study.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 7 - 7
1 Nov 2018
Wong L Moriarty P Harty J
Full Access

Revision total hip arthroplasty (THA) presents with increasing challenges, potentially compromising the integrity of a revision. The objective of this study was to assess radiologic outcomes of patients who underwent revision THA with a modular tapered stem (Reclaim, DePuy Synthes). This study retrospectively examined all revision Reclaim THAs between 2012 and 2016. Radiologic assessment compared x-rays at two time points: immediately after surgery and the most recent x-ray available. Leg length discrepancy, subsidence and line-to-line fit was assessed. Significant subsidence was considered ≥10mm. Adequate line-to-line fit was considered ≥30mm of bicortical contact. Descriptive statistics included clinical factors (i.e. age, Paprosky classification). P values <0.05 were considered significant. A total of 81 femoral revisions were completed. There were 42 females and 38 males with a mean age of 71 years (range, 46–89). Of these, 6 were revised (dislocation, fracture or infection), and 7 were lost to follow up. Average follow up time was 18 months (range, 1–46 months). Femoral revisions were classified as Paprosky 3a or 3b. Mean stem subsidence was 4.15mm (range, 0–25.6mm). Subsidence of the femoral stem was <10mm in 88% of patients. A total of 62% of patients had both subsidence <10mm and ≥30mm of bicortical contact. In patients with <10mm subsidence, 70% had ≥30mm of bicortical contact. There was a positive trend between cortical contact and stem stability (OR 2.3). The Reclaim modular femoral system has demonstrated radiographic stability. Inadequate initial fit is a potential determinant of subsidence.