Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_4 | Pages 42 - 42
1 Apr 2018
Gabler C Gierschner S Lindner T Tischer T Bader R
Full Access

The biomechanical evaluation of tendon repair with collagen-based scaffolds in rat model is a common method to determine the functional outcome of the tested material. We introduced a magnetic resonance imaging (MRI) approach to verify the biomechanical test data. In present study different collagen scaffolds for tendon repair were examined.

Two collagen test materials: based on bovine stabilized collagen, chemically cross-linked with oriented collagenous fibres (material 1) and based on porcine dermal extracellular matrix, with no cross-linking (material 2) were compared. The animal study was approved by the local review board. Surgery was performed on male Sprague-Dawley rats with a body weight of 400 ± 19 g. Each rat underwent a 5 mm transection of the right Achilles tendon. The M. plantaris tendon was removed. The remaining tendon ends were re-joined with a 5 mm scaffold of either the material 1 or 2. Each scaffold material was sutured into place with two single stiches (Vicryl 4–0, Ethicon) each end. A total of 16 rats (n= 8 each group) were observed for 28 days follow up. The animals were sacrificed and hind limbs were transected proximal to the knee joint. MRI was performed using a 7 Tesla scanner (BioSpec 70/30, Bruker). T2-weighted TurboRARE sequences with an in-plane resolution of 0.12 mm and a slice thickness of 0.7 mm were analysed. All soft and hard tissues were removed from the Achilles tendon-calcaneus-foot complex before biomechanical testing. Subsequently, the specimens were fixed in a materials testing machine (Z1.0, Zwick, Ulm, Germany) for tensile testing. All tendons were preloaded with 1 N and subsequently stretched at a rate of 1 mm/s until complete failure was observed. Non-operated tendons were used as a control (n=4).

After 28 postoperative days, MRI demonstrated that four scaffolds (material 1: n=2, material 2: n=2) were slightly dislocated in the proximal part of hind limb. In total five failures of reconstruction could be detected in the tendon repairs (material 1: n=3, material 2: n=2). Tendons augmented with the bovine material 1 showed a maximum tensile load of 57.9 ± 17.9 N and tendons with porcine scaffold material 2 of 63.1 ± 19.5 N. The native tendons demonstrated only slightly higher loads of 76.6 ± 11.6 N. Maximum failure load of the tendon-scaffold construct in both groups did not differ significantly (p < 0.05). Stiffness of the tendons treated with the bovine scaffold (9.9 ± 3.6 N/mm) and with the porcine scaffold (10.7 ± 2.7 N/mm) showed no differences. Stiffness of the native healthy tendon of the contralateral site was significantly higher (20.2 ± 6.6 N/mm, p < 0.05). No differences in the mechanical properties between samples of both scaffold groups could be detected, regardless of whether the repaired tendon defect has failed or the scaffold has been dislocated.

The results show that MRI is important as an auxiliary tool to verify the biomechanical outcome of tendon repair in animal models.


The Journal of Bone & Joint Surgery British Volume
Vol. 84-B, Issue 4 | Pages 592 - 599
1 May 2002
Maier M Milz S Tischer T Münzing W Manthey N Stäbler A Holzknecht N Weiler C Nerlich A Refior HJ Schmitz C

There is little information about the effects of extracorporeal shock-wave about application the effects (ESWA) of on normal bone physiology. We have therefore investigated the effects of ESWA on intact distal rabbit femora in vivo. The animals received 1500 shock-wave pulses each of different energy flux densities (EFD) on either the left or right femur or remained untreated. The effects were studied by bone scintigraphy, MRI and histopathological examination.

Ten days after ESWA (0.5 mJ/mm2 and 0.9 mJ/mm2 EFD), local blood flow and bone metabolism were decreased, but were increased 28 days after ESWA (0.9 mJ/mm2). One day after ESWA with 0.9 mJ/mm2 EFD but not with 0.5 mJ/mm2, there were signs of soft-tissue oedema, epiperiosteal fluid and bone-marrow oedema on MRI. In addition, deposits of haemosiderin were found epiperiosteally and within the marrow cavity ten days after ESWA.

We conclude that ESWA with both 0.5 mJ/mm2 and 0.9 mJ/mm2 EFD affected the normal bone physiology in the distal rabbit femur. Considerable damaging side-effects were observed with 0.9 mJ/mm2 EFD on periosteal soft tissue and tissue within the bone-marrow cavity.