header advert
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 38 - 38
1 Sep 2012
Misur P Strick N Puna R Walker C
Full Access

There has recently been a proliferation of image-based knee arthroplasty systems which utilize pre-operative radiological analysis of a patient's anatomy to identify the bone cuts required to correct their mechanical alignment. The aim of this was to assess the accuracy of one such system (Visionaire™, Smith and Nephew Inc.©)

Eleven cadavers were imaged using the Smith and Nephew Visionaire® MRI protocol to enable the production of cutting blocks individualized to the various specimens. These cutting blocks were then used to perform knee replacements on all cadavers. Post-operatively the validated Perth CT protocol was used to assess the position and rotational profile of each implant. These measurements were then compared to the pre-operative plan in order to assess the accuracy of implant placement.

Relative to the pre-operative target parameters, the femoral components were aligned in a mean 0.048° valgus (95% CI – 0.36° to 1.32°) with 1.8° extension (95% CI −0.1° to 4.5°) and externally rotated by a mean 0.66° (95% CI 1.08° internal rotation to 2.4° external rotation.) The tibial components were in a mean 0.29° of varus (95% CI – 0.68° to 1.27°) with a posterior tibial slope of 90.5° (95% CI 89.6° to 92.6°) and internally rotated by a mean 1.7° (range 10.1° internal rotation to 1.1° external rotation.)

The findings of our study suggest that the Visionaire system can produce accurate coronal implant alignment. The saggital and rotational alignment was not as reliable although these parameters may have been more prone to adverse influence by the limitations of the cadaveric model. Patient-matched knee arthroplasty technology offers significant potential benefits to both patient and surgeon and warrants further clinical investigation.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_III | Pages 201 - 201
1 Mar 2003
Strick N Horne J Devane P Stevanovic V
Full Access

There is controversy regarding the best way to manage fit, independent patients with acute hip fractures. The aim of this study was to compare, nationally, the early complication rates of total hip arthroplasty (THA) in those patients with an acute fractured neck of femur (NOF) with a similar group of THA’s performed in patients with a diagnosis of osteoarthritis.

Using the National Hip Joint Register and the New Zealand Health Information Service Database, 200 patients with acute hip fractures undergoing THA were identified and compared to 1102 THA’s performed on osteoarthritis patients. The mortality, revision, dislocation and infection rates were analysed at a minimum of one year.

Acute THA had a 7.5% one-year mortality rate compared with 2.5% in the OA group (p < 0.01). The revision rate was 2.5% vs 1.8% in the acute and OA groups respectively. The dislocation rate was 4.3% for the whole group with a 8.5% for the acute group and 3.5% for the OA group (p< 0.01). In the acute group the dislocation rate using the posterior approach was 17.1 % compared to 3.1% for the lateral approach (p< 0.01).

We conclude that acute THA is a useful procedure in fit patients with a fracture of the neck of the femur but that a posterior approach should be avoided.