header advert
Results 1 - 7 of 7
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXX | Pages 17 - 17
1 Jul 2012
Picardo N Blunn G Shekkeris A Aston W Pollock R Meswania J Cannon S Skinner J Briggs T
Full Access

Introduction

Following bone tumour resection, lower limb reconstruction results in leg-length discrepancy in skeletally immature patients. Previously, minimally invasive endoprostheses have been associated with a high risk of complications including joint stiffness, nerve injury, aseptic loosening and infection. The purpose of this study was to examine the outcome of the Stanmore non-invasive extendible endoprostheses used in our institution between 2002 and 2009 and compare them with implants used in the past.

Methods

Fifty-five children with a mean age of 11.4 years (5 to 16) underwent limb reconstruction with thirty-three distal femoral, two total femoral, eight proximal femoral and twelve proximal tibial implants. Forty-six endoprostheses were lengthened in clinic without anaesthesia using the principle of electromagnetic induction. Patients were assessed using the Musculoskeletal Tumour Society Score (MSTS) and the Toronto Extremity Salvage Score (TESS).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXX | Pages 40 - 40
1 Jul 2012
Sabharwal S Datta G Berber O Aston W Pollock R Skinner J Cannon S Briggs T
Full Access

Introduction

The proximity of the superior tibiofibular articulation to neurovascular structures makes the management of extraosseous tumours of the proximal fibula challenging in bone tumour surgery. The aim of study is to establish whether the recurrence rates are higher in this anatomical area compared to data that already exists in publication for bone tumours throughout the appendicular skeleton.

Method

A retrospective study of all patients treated for Ewing's tumours and osteosarcoma at a regional bone tumour unit between January 1995 and December 2009 was conducted.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXX | Pages 16 - 16
1 Jul 2012
Perera J Gikas P Griffiths D Donaldson J Aston W Pollock R Skinner J Cannon S Briggs T
Full Access

Sixty eight consecutive patients underwent proximal humeral replacement with a fixed fulcrum massive endoprosthesis for tumour between 1997 and 2007. The mean age was 46 years (7-87). Ten patients were lost to follow up and 16 patients died. The 42 surviving patients were assessed using the Musculoskeletal Tumour Society (MSTS) Score and the Toronto Extremity Salvage Score (TESS). The mean MSTS score was 72.3 % and the mean TESS was 77.2 %.

Four of 42 patients received a new constrained humeral liner to reduce the risk of dislocation. This sub group of 4 patients had a mean MSTS score of 77.7 % and a mean TESS of 80.0%.

Endoprosthetic replacement for tumour of the proximal humerus using this prosthesis is a reliable operation yielding good functional results without the documented problems of unconstrained prostheses. The performance of this prosthesis is expected to improve further with the new constrained humeral liner.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXX | Pages 6 - 6
1 Jul 2012
Shekkeris A Pollock R Aston W Cannon S Blunn G Skinner J Briggs T
Full Access

Introduction

Primary bone tumours of the distal radius are rare, while it remains the third commonest site for primary lesions and recurrences of Giant Cell Tumours (GCT). The functional demands on the hand make reconstruction of the wrist joint following the excision of distal radius, particularly challenging.

Methods

A single-centre retrospective study, reporting the functional and oncological outcomes of six patients (4 males, 2 females - mean age of 53 (22 to 79)) who underwent a custom-made endoprosthetic replacement of the distal radius with arthrodesis at our institution, during 1999 - 2010. Five patients were diagnosed with primary bone sarcoma of the distal radius (4 GCTs, 1 osteosarcoma) and another had a metastatic lesion from a primary renal cell carcinoma. The diagnosis was confirmed by needle biopsy in all cases.

We assessed the patients' functional outcomes using the Musculoskeletal Tumour Society scoring system (MSTS) and the Toronto Extremity Salvage Score (TESS).


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 399 - 403
1 Mar 2011
Griffiths D Gikas PD Jowett C Bayliss L Aston W Skinner J Cannon S Blunn G Briggs TWR Pollock R

Between 1997 and 2007, 68 consecutive patients underwent replacement of the proximal humerus for tumour using a fixed-fulcrum massive endoprosthesis. Their mean age was 46 years (7 to 87). Ten patients were lost to follow-up and 16 patients died. The 42 surviving patients were assessed using the Musculoskeletal Tumor Society (MSTS) Score and the Toronto Extremity Salvage Score (TESS) at a mean follow-up of five years and 11 months (one year to ten years and nine months). The mean MSTS score was 72.3% (53.3% to 100%) and the mean TESS was 77.2% (58.6% to 100%).

Four of 42 patients received a new constrained humeral liner to reduce the risk of dislocation. This subgroup had a mean MSTS score of 77.7% and a mean TESS of 80.0%. The dislocation rate for the original prosthesis was 25.9; none of the patients with the new liner had a dislocation at a mean of 14.5 months (12 to 18).

Endoprosthetic replacement for tumours of the proximal humerus using this prosthesis is a reliable operation yielding good results without the documented problems of unconstrained prostheses. The performance of this prosthesis is expected to improve further with a new constrained humeral liner, which reduces the risk of dislocation.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1134 - 1137
1 Aug 2010
Kalson NS Gikas PD Aston W Miles J Blunn G Pollock R Skinner J Briggs TWR Cannon SR

Disarticulation of the hip in patients with high-grade tumours in the upper thigh results in significant morbidity. In patients with no disease of the proximal soft tissue a femoral stump may be preserved, leaving a fulcrum for movement and weight-bearing. We reviewed nine patients in whom the oncological decision would normally be to disarticulate, but who were treated by implantation of an endoprosthesis in order to create a functioning femoral stump. The surgery was undertaken for chondrosarcoma in four patients, pleomorphic sarcoma in three, osteosarcoma in one and fibrous dysplasia in one. At follow-up at a mean of 80 months (34 to 132), seven patients were alive and free from disease, one had died from lung metastases and another from a myocardial infarction. The mean functional outcome assessment was 50 (musculoskeletal tumor society), 50 and 60 (physical and mental Short-form 36 scores).

Implantation of an endoprosthesis into the stump in carefully selected patients allows fitting of an above-knee prosthesis and improves wellbeing and the functional outcome.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 10 | Pages 1367 - 1372
1 Oct 2006
Gupta A Pollock R Cannon SR Briggs TWR Skinner J Blunn G

We used a knee-sparing distal femoral endoprosthesis in young patients with malignant bone tumours of the distal femur in whom it was possible to resect the tumour and to preserve the distal femoral condyles. The proximal shaft of the endoprosthesis had a coated hydroxyapatite collar, while the distal end had hydroxyapatite-coated extracortical plates to secure it to the small residual femoral condylar fragment. We reviewed the preliminary results of this endoprosthesis in eight patients with primary bone tumours of the distal femur. Their mean age at surgery was 17.years (14 to 21). The mean follow-up was 24 months (20 to 31). At final follow-up the mean flexion at the knee was 102° (20° to 120°) and the mean Musculoskeletal Tumour Society score was 80% (57% to 96.7%).

There was excellent osteointegration at the prosthesis-proximal bone interface with formation of new bone around the hydroxyapatite collar. The prosthesis allowed preservation of the knee and achieved a good functional result. Formation of new bone and remodelling at the interface make the implant more secure. Further follow-up is required to determine the long-term structural integrity of the prosthesis.