Results 1 - 5 of 5
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 11 - 11
10 May 2024
Stowers M Slykerman L McClean L Senthi S
Full Access

Introduction

A common acute orthopaedic presentation is an ulcerated or infected foot secondary to diabetic neuropathy. Surgical debridement or amputation are often required to manage this complication of diabetes. International literature indicates that amputation may lead to further complications and an increased mortality rate. The aim of this study is to investigate the mortality rate associated with different surgical interventions. This will inform surgical management of patients presenting with acute foot complications from diabetes.

Methods

This is a retrospective review of patients with diabetic foot infections aged >16 years attending Middlemore Hospital over a 10-year period (2012–2021). Clinical records were examined to determine whether patients were managed with no surgery, surgery but not amputation, or amputation. We recorded relevant baseline characteristics and comorbidities. Regression models were used to determine factors associated with mortality.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_7 | Pages 17 - 17
8 May 2024
Senthi S Miller D Hepple S Harries W Winson I
Full Access

Tendoscopy in the treatment of peroneal tendon disorders is becoming an increasingly safe, reliable, and reproducible technique. Peroneal tendoscopy can be used as both an isolated procedure and as an adjacent procedure with other surgical techniques. The aim of our study was to review all peroneal tendoscopy that was undertaken at the AOC, by the senior authors (IGW, SH), and to determine the safety and efficacy of this surgical technique.

Methods

From 2000 to 2017 a manual and electronic database search was undertaken of all procedures by the senior authors. Peroneal tendoscopy cases were identified and then prospectively analysed.

Results

51 patients (23 male, 28 female) were identified from 2004–2017 using a manual and electronic database search. The mean age at time of surgery was 41.5 years (range 16–83) with a mean follow-up time post operatively of 11.8 months (range 9–64 months). The main indications for surgery were lateral and/or postero-lateral ankle pain and lateral ankle swelling. The majority of cases showed unstable peroneal tendon tears that were debrided safely using tendoscopy. Of the 51 patients, 23 required an adjacent foot and ankle operation at the same time, 5 open and 17 arthroscopic (12 ankle, 5 subtalar). Open procedures included 2 first ray osteotomies, 2 open debridements of accessory tissue, one PL to PB transfer. One patient also had an endoscopic FHL transfer. Complication rates to date have been low: 2 superficial wound infections (4%) and one repeat tendoscopy for ongoing pain. A small proportion of patients with ongoing pain were treated with USS guided steroid injections with good results.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_7 | Pages 6 - 6
8 May 2024
Miller D Senthi S Winson I
Full Access

Background

Total ankle replacements (TARs) are becoming increasingly more common in the treatment of end stage ankle arthritis. As a consequence, more patients are presenting with the complex situation of the failing TAR. The aim of this study was to present our case series of isolated ankle fusions post failed TAR using a spinal cage construct and anterior plating technique.

Methods

A retrospective review of prospectively collected data was performed for 6 patients that had isolated ankle fusions performed for failed TAR. These were performed by a single surgeon (IW) between March 2012 and October 2014. The procedure was performed using a Spinal Cage construct and grafting in the joint defect and anterior plating. Our primary outcome measure was clinical and radiographic union at 1 year. Union was defined as clinical union and no evidence of radiographic hardware loosening or persistent joint lucent line at 1 year.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_21 | Pages 22 - 22
1 Dec 2017
Robinson P Senthi S Nall A Hepple S Harries W Winson I
Full Access

Introduction

Flexor Hallucis Longus (FHL) tendon transfer is a well-recognised salvage operation for irreparable tendon Achilles (TA) ruptures and intractable Achilles tenonopathy. Several case series describes the technique and results of arthroscopic FHL tendon transfers. We present a comparative case series of open and arthroscopic FHL tendon transfers from Southmead Hospital, Bristol, UK.

Methods

For the arthroscopic FHL transfers in most cases the patients were positioned semi prone with a tourniquet. A 2 or 3 posterior portal technique was used and the tendon was secured using an RCI screw. The rehabilitation was similar in both groups with 2 weeks in an equinus backslab followed by gradual dorsiflexion in a boot over the following 6 weeks. Anticoagulation with oral aspirin for 6 weeks was used. A retrospective case note review was performed.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 376 - 376
1 Jul 2011
Senthi S Stott S Blyth P Metcalfe R
Full Access

Unrecognized pin penetrance in the treatment of SCFE by percutaneous pinning has been shown to be under-reported with serious long-term sequelae. The purpose of this study was to use post-operative CT to determine the true position of the screw tip when compared to intra-operative x-rays.

Twenty-four patients were offered post operative CT scans in the acute and clinic setting. Intra-operative plain films (AP and lateral) were compared to post operative CT scans (coronal and axial) to determine

the distance of the screw tip from the particular surface of the hip joint,

the number of screw threads across the physis and

the three dimensional placement of the screw tip in the femoral head relative to the physis.

The positions of a total of 38 screws were measured. Plain x-rays where shown to consistently underestimate the distance to the articular surface. There were significant differences in the distance to the articular surface in the AP (5.5 mm) vs. coronal (3.4 mm) and lateral (4.7 mm) and vs. axial CT (4.1 mm) planes (p < 0.01). The average number of screw threads across the articular surface on the lateral x-ray was 6.7 vs. 8.1 in the coronal CT (p< 0.05). Four of the screws were shown to penetrate the joint surface in CT not shown on plain film.

This study has found that CT scans show screws are closer to the joint surface in the axial and coronal plane on CT when compared to plain x-ray in the AP and lateral plane. CT scans also show that there are more screw threads across the epiphysis than shown on plain x-ray. Placement of the screw within specific quadrants of the femoral head was found to be similar on CT and x-ray. CT scans identified pin penetrance not seen on intra-operative images.