header advert
Results 1 - 5 of 5
Results per page:
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 4 - 4
1 Jan 2016
Latham J Goriainov V Pedersen R Gadegaard N Dunlop D Oreffo R
Full Access

Background

In 2012, the National Joint Registry recorded 86,488 primary total hip replacements (THR) and 9,678 revisions (1). To date aseptic loosening remains the most common cause of revision in hip and knee arthroplasty, accounting for 40% and 32% of all cases respectively and emphasising the need to optimise osseointegration in order to reduce revisions. Clinically, osseointegration results in asymptomatic stable durable fixation of orthopaedic implants. Osseointegration is a complex process involving a number of distinct mechanisms affected by the implant surface topography, which is defined by surface orientation and surface roughness. Micro- and nano-topography levels have discrete effects on implant osseointegration and yet the role on cell function and subsequent bone implant function is unknown. Nanotopography such as collagen banding is a critical component influencing the SSC niche in vivo and has been shown to influence a range of cell behaviours in vitro (2,3). We have used unique fabricated nanotopographical pillar substrates to examine the function of human bone stem cells on titanium surfaces.

Aim

To investigate the effect of nanotopographical cues on adult skeletal stem cell (SSC) fate, phenotype and function within in-vitro environments.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 163 - 163
1 Sep 2012
Smith J Sengers B Aarvold A Tayton E Dunlop D Oreffo R
Full Access

Recently, the osteoregenerative properties of allograft have been enhanced by addition of autogenous skeletal stem cells to treat orthopaedic conditions characterised by lost bone stock. There are multiple disadvantages to allograft, and trabecular tantalum represents a potential alternative. This metal is widely used, although in applications where there is poor initial stability, or when it is used in conjunction with bone grafting, loading may need to be limited until sound integration has occurred. Strategies to speed up implant incorporation to surrounding bone are therefore required. This may improve patient outcomes, extending the clinical applications of tantalum as a substitute for allograft.

Aim

To use tissue engineering strategies to enhance the reconstructive properties of tantalum, as an alternative to allograft.

Methods

Human bone marrow stromal cells (5×105 cells/ml) were cultured on blocks of trabecular tantalum or allograft for 28 days in basal and osteogenic media. Molecular profiling, confocal and scanning electron microscopy, as well as live/dead staining and biochemical assays were used to detail cell adherence, proliferation and phenotype.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 204 - 204
1 Sep 2012
Smith J Dawson J Aarvold A Jones A Ridgway J Curran S Dunlop D Oreffo R
Full Access

Background

Replacing bone lost as a consequence of trauma or disease is a major challenge in the treatment of musculoskeletal disorders. Tissue engineering strategies seek to harness the potential of stem cells to regenerate lost or damaged tissue. Bone marrow aspirate (BMA) provides a promising autologous source of skeletal stem cells (SSCs) however, previous studies have demonstrated that the concentration of SSCs required for robust tissue regeneration is below levels present in iliac crest BMA, emphasising the need for cell enrichment strategies prior to clinical application.

Aims

To develop a novel strategy to enrich skeletal stem cells (SSCs) from human BMA, clinically applicable for intra-operative orthopaedic use.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 212 - 212
1 Sep 2012
Tayton E Purcell M Briscoe A Kalra S Aarvold A Smith J Fahmy S Shakesheff K Howdle S Dunlop D Oreffo R
Full Access

Aims

Disease transmission, availability and economic costs of allograft have resulted in significant efforts into finding an allograft alternative for use in impaction bone grafting (IBG). Biotechnology offers the combination of skeletal stem cells (SSC) with biodegradable polymers as a potential solution. Recently polymers have been identified with both structural strength and SSC compatibility that offer the potential for clinical translation.

The aim of this study was to assess whether increasing the porosity of one such polymer via super critical CO2 fluid foaming (SCF) enhanced the mechanical and cellular compatibility characteristics for use as an osteogenic alternative to allograft in IBG.

Methods

High molecular weight PLA scaffolds were produced via traditional (solid block) and SCF (porous) techniques, and the differences characterised using scanning electron microscopy (SEM). The polymers were milled, impacted, and mechanical comparison between traditional vs SCD created scaffolds and allograft controls was made using a custom shear testing rig, as well as a novel agitation test to assess cohesion. Cellular compatibility tests for cell number, viability and osteogenic differentiation using WST-1 assays, fluorostaining and ALP assays were determined following 14 day culture with SSC's.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 211 - 211
1 Sep 2012
Tayton E Fahmy S Aarvold A Smith J Kalra S Briscoe A Shakesheff K Howdle S Dunlop D Oreffo R
Full Access

Aims

Impaction bone grafting with milled human allograft is the gold standard for replacing lost bone stock during revision hip surgery. Problems surrounding the use of allograft include cost, availability, disease transmission and stem subsidence (usually due to shear failure of the surrounding allograft).

The aim of this study was to investigate various polymers for use as substitute allograft. The ideal graft would be a composite with similar mechanical characteristics as allograft, and with the ability to form de novo bone.

Methods

High and low molecular weight (MW) forms of three different polymers (polylactic acid (PLA), poly (lactic co-glycolic) acid (PLGA) and polycaprolactone (PCL)) were milled, impacted into discs, and then tested in a custom built shear testing rig, and compared to allograft.

A second stage of the experiment involved the addition of skeletal stem cells (SSC) to each of the milled polymers, impaction, 8 days incubation, and then tests for cell viability and number, via fluorostaining and biochemical (WST-1) assays.