header advert
Results 1 - 2 of 2
Results per page:
Applied filters
Research

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 51 - 51
1 Nov 2018
Negri S Regis D Sandri A Magnan B
Full Access

Introduction. The management of periprosthetic pelvic bone loss is a challenging problem in hip revision surgery. This study evaluates the minimum 10-year clinical and radiographic outcome of major column structural allografts combined with the Burch-Schneider antiprotrusio cage for acetabular reconstruction. Methods. From January 1992 to August 2005, 106 hips with periprosthetic osteolysis underwent acetabular revision using massive allografts and the Burch-Schneider antiprotrusio cage. Forty-five patients (49 hips) died for unrelated causes without further surgery. Fifty-nine hips in 59 patients underwent clinical and radiographic evaluation at an average follow-up of 15.1 years. There were 17 male and 42 female patients, with age ranging from 29 to 83 years (mean 59). Results. Ten hips required rerevision because of infection (3), aseptic loosening (6), and flange breakage (1). Moreover, 4 cages showed x-ray signs of instability with severe bone resorption. The survivorship of the Burch-Schneider cage at 21.9 years with removal for any reason or radiographic migration and aseptic or radiographic failure as the end points were 76.3 and 81.4, respectively. The average Harris hip score improved from 33.2 points preoperatively to 75.7 points at the latest follow-up (p < 0.001). Discussion. In hip revision surgery, severe deficiency of pelvic bone stock is a critical concern because of the difficulty in providing a stable and durable fixation of the prosthesis. Although antiprotrusio cages have a limited role in acetabular revision, the use in association with massive allografts in extended bone loss demonstrated highly successful long-term results, enabling bone stock restoration and cup stability.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 5 - 5
1 Nov 2018
Samaila E Negri S Magnan B
Full Access

Total ankle replacement (TAR) is contraindicated in patients with significant talar collapse due to AVN and in these patients total talus body prosthesis has been proposed to restore ankle joint. To date, five studies have reported implantation of a custom-made talar body in patients with severely damaged talus, showing the limit of short-term damage of tibial and calcaneal thalamic joint surfaces. Four of this kind of implants have been performed. The first two realized with “traditional” technology CAD-CAM has been performed in active patients affected by “missing talus” and now presents a survival follow-up of 15 and 17 years. For the third patient affected by massive talus AVN we designed a 3D printed porous titanium custom talar body prosthesis fixed on the calcaneum and coupled with a TAR, first acquiring high-resolution 3D CT images of the contralateral healthy talus that was “mirroring” obtaining the volume of fractured talus in order to provide the optimal fit. Then the 3D printed implant was manufactured. The fourth concern a TAR septic mobilization with high bone loss of the talus. The “two-stage” reconstruction conducted with the implant of total tibio-talo-calcaneal prosthesis “custom made” built with the same technology 3D, entirely in titanium and using the “trabecular metal” technology for the calcaneous interface. Weightbearing has progressively allowed after 6 weeks. No complications were observed. All the implants are still in place with an overall joint mobility ranging from 40° to 60°. This treatment requires high demanding technical skills and experience with TAR and foot and ankle trauma. The 15 years survival of 2 total talar prosthesis coupled to a TAR manufactured by a CAD-CAM procedure encourages consider this 3D printed custom implant as a new alternative solution for massive AVN and traumatic missing talus in active patients.