Lass R Gruebl A Kolb A Stelzeneder D Pilger A Kubista B Giurea A Windhager R
Full Access

Introduction

In a recent study we evaluated the clinical and radiographic long-term results as well as the serum metal concentrations of 105 cementless primary total hip prosthesis, performed between November 1992 and May 1994 with a 28-mm high-carbide-concentration metal-on-metal articulating surfaces. Forty-one patients who had had a total of forty-four arthroplasties were available for follow-up evaluation at a minimum of seventeen years postoperatively.

The median serum cobalt concentration of the patients with their hip replacement as the only source of cobalt was 0.7 µg/L (range 0.4–5.1µg/L), showing no significant difference to the previous study after a minimum of 10 years follow-up. We were investigating the systemic dissemination, which in turn, did not show more severe effects, such as carcinogenicity or renal failure. There are many complex issues associated with the analysis of metal ions, including collecting technique, analysis and reporting of the results. At the AAOS in March 2013, the Hip Society mentioned, that systemic ion levels are just one factor in the evaluation and should not be relied upon solely to determine the need for revision surgery. Furthermore, the correlation between cobalt or chromium serum, urin or synovial fluid levels and adverse local tissue reactions is incompletely understood.

Patients and Methods

In our present study we evaluated the serum, urin as well as the joint aspirate metal concentrations, of cementless total hip arthroplasties with a high-carbon, metal-on-metal bearing (Metasul®) at a mean of eighteen-years follow-up. We performed a correlation analysis to evaluate the relationship between these values and to determine whether elevated serum metal concentrations are associated with elevated and local metal concentrations and with early failure of metal-on-metal articulations.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 500 - 500
1 Sep 2012
Kolb A Chiari C Kaider A Zehetgruber H Schneckener C Grübl A
Full Access

We present our results of cementless total hip arthroplasty with a tapered, rectangular stem made of titanium-aluminum-niobium alloy. This implant is used since 1979 with only minor modifications. The design of the femoral component achieves primary stability through precision rasping and press-fit implantation.

Between October 1986 and November 1987, two hundred consecutive patients (208 hips) underwent total hip arthroplasty with this tapered, rectangular stem. In all cases the acetabular component was a threaded cup made of titanium.

At a minimum follow-up of twenty years eighty-seven patients were still alive. Sixty-seven patients (69 hips) were available for clinical and radiographic follow-up. The probability of survival of the stem was 0.96 (95% confidence interval, 0.91 to 0.98) and that of the cup was 0.72 (0.62 to 0.80). The probability of survival of both the stem and the acetabular component with revision for any reason as the end point was 0.71 (0.61 to 0.78).

Two stems have been revised due to aseptic loosening. We found various degrees of osteolysis around the acetabular and femoral component (61,7%). At the time of the 20-year follow-up no stem was deemed at risk for loosening.

The key findings of our twenty-year follow-up are the very low rate of revisions of the femoral component and the low rate of distal femoral osteolysis associated with this stem. Our data show that femoral fixation of the stem continues to be secure at a follow-up of twenty years.