Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 464 - 464
1 Sep 2012
Lindfors N Hyvönen P Nyyssönen M Kirjavainen M Kankare J Gullichsen E Salo J Lindfors N
Full Access

Bioactive glasses (BAGs) are bone substitutes with bone bonding, angiogenesis promoting and antibacterial properties. The bioactive process leading to bone bonding has been described as a sequence of reactions in the glass and at its surface. Implantation of the glass is followed by a rapid exchange of Na+ in the glass with H+ and H3O+ from the surrounding tissue, leading to the formation of silanol (SiOH) groups at the glass surface. Due to migration of Ca2+ and PO43− groups to the surface and cystallization, a CaO-P2O5 hydroxyapatite (HA) layer is formed on top of the Si-rich layer. Finally, cell interactions with the HA layer subsequently initiate the bone forming pathway.

The rapid increase in pH and the subsequent osmotic effect caused by dissolution of the glass have been suggested to partly explain the antibacterial properties observed for BAGs. Comparing bactericidal effects of different BAGs, BAG-S53P4 has been shown to be the most effective, with the fastest killing or growth inhibitory effect. This antibacterial effect has been observed in vitro for all pathogens tested, including the most important aerobic and anaerobic pathogens, as well as very resistant bacteria.

In a multicentre study in 2007–2009, BAG-S53P4 was used as bone graft substitute in treatment of osteomyelitis. Eleven patients (nine males, two females) with a radiologically diagnosed osteomyelitis in the lower extremity (N=10) and in the spine (N-1) participated.

In the operation, the infected bone and the soft tissue were removed, and the cavitary bone defects were filled with BAG-S53P4 (BonAlive™, Bonalive Biomaterials Ltd., Finland). In four patients, muscle flaps were used as part of the treatment. Eight patients were treated in a one-stage procedure. Kanamycin granules were used in one patient and Garamycin granules (Septocol ®) in two patients.

Patient data were obtained from hospital patient' records until August 2010, resulting in a mean follow-up period of 29 months (range 15–43).

BAG-S53P4 was well tolerated; no BAG-related adverse effects were seen in any patient. The use of BAG-S53P4 as a bone graft substitute resulted in a fast recovery. Long-term clinical outcome was good or excellent in ten of eleven patients.

These primary results indicate that BAG-S53P4 can be considered as a good and usable material in treatment of osteomyelitis. After this study BAG-S53P4 has been used in several other patients with very promising results.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 10 - 10
1 Mar 2009
Attal R Müller M Hansen M Bail H Kirjavainen M Hammer T Blauth M Höntzsch D Rommens P
Full Access

Introduction: The Expert Tibia Nail was designed to address proximal, shaft, segmental and distal tibia fractures in one implant. Multiple locking options in various directions provide more stability and reduce the risk of secondary malalignment. Angle stable cancellous bone locking screws in the tibia head also improve fixation.

We evaluated this new implant in our series in a prospective, multicenter setting.

Methods: 190 patients were treated in 10 participating centers using the Expert Tibia Nail (Synthes). 127 patients suffered polytrauma, 58 presented as open fractures. Within the framework of the study 5 cases were proximal tibia fractures, 108 shaft fractures, 56 distal fractures, and 21 segmental fractures. These were followed-up postoperatively, after 3 months and one year and evaluated radiologically and clinically with regard to malalignment, union rate and complications.

Results: Non union occurred in 9 cases after one year of follow up (n=150). 20 patients showed delayed union. The rate of open and complex fractures was high in this group. Dynamisation was performed in 10 cases. Valgus/varus and recurvatum/antecurvatum malalignment of more than 5 degrees occurred in 13 cases. Stable reduction was achieved in 144 cases. In 4 complex fractures, initial reduction went into malalignment. 2 patients developed a deep infection after 3rd degree open fractures. 34 patients suffered from pain in the operated area. 6 screws broke during the follow-up.

Discussion: The Expert Tibia Nail proved to be an excellent tool to treat tibia fractures. Not only shaft fractures but also complex fractures in the proximal and distal metaphyseal area can be successfully stabilized due to advanced locking options and design of the nail. The rate of malalignment, non-union and complications was low.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 349 - 355
1 Mar 2008
Kirjavainen M Remes V Peltonen J Rautakorpi S Helenius I Nietosvaara Y

Hand function was evaluated in 105 patients who had been operated on in early infancy for brachial plexus birth palsy. The mean follow-up after surgery was for 13.4 years (5.0 to 31.5). Fine sensation, stereognosis, grip and pinch strength and the Raimondi scale were recorded.

Fine sensation was normal in 34 of 49 patients (69%) with C5–6 injury, 15 of 31 (48%) with C5–7 and in 8 of 25 (32%) with total injury. Loss of protective sensation or absent sensation was noted in some palmar areas of the hand in 12 of 105 patients (11%). Normal stereognosis was recorded in 88 of the 105 patients (84%), whereas only 9 of the 105 (9%) had normal grip strength. The mean Raimondi scale scores were 4.57 (3 to 5) (C5–6), 4.26 (1 to 5) (C5–7) and 2.16 (0 to 5) in patients with total injury.

The location of impaired sensation was related to the distribution of the root injury. Avulsion type of injury correlated with poor recovery of hand function.