header advert
Results 1 - 3 of 3
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 102 - 102
1 Mar 2017
Rakow A Schoon J Dienelt A John T Textor M Duda G Perka C Schulze F Ode A
Full Access

INTRODUCTION

The uncertainty of the biological effects of wear and corrosion from Metal-on-metal (MoM) implants has initiated a debate on their safety and use. Generally, the release of wear particles from MoM hip implants can clinically manifest in aseptic osteolysis. In our study, the effect of MoM-wear particles and particle originated Co and Cr ions on mesenchymal stromal cells (MSCs) was investigated [1]. The lead hypotheses were that (1) dissociated Co and Cr, originated from MoM-wear particles, accumulate in the bone marrow and (2) apparently impair the osteogenic function of local MSCs. This impairment could be one element contributing to the manifestation of periprosthetic osteolyses.

METHODS

The study was approved by the local ethical committee (EA1/194/13); all donors gave written informed consent. Blood (B), Synovial fluid (SF) periprosthetic tissue (PT) and bone marrow (BM) were collected from patients with at least one osteolytic lesion, undergoing a revision of a MoM hip implant. Patients undergoing primary THA served as controls. Metal wear particles were isolated from PT by enzymatic digestion and their size and shape characterized by transmission electron microscopy (TEM). Local and systemic levels of Co and Cr were analyzed by graphite furnace atomic absorption spectroscopy. MoM-MSCs and control-MSCs were isolated from BM for in vitro assessment of their viability, proliferation, migration and multilineage differentiation. In addition, control-MSCs were in vitro exposed to Co and Cr ions and assessed for their viability, proliferation and osteogenic differentiation.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 129 - 129
1 Jan 2016
Park C John T Ghosh G Ranawat AS Ranawat CS
Full Access

Introduction

Total hip arthroplasty (THR) with non-cemented or hybrid fixation remains one of the most successful procedures performed today. The aim of this study was to assess the safety and efficacy of a hydroxyapatite (HA) coated, hemispherical cup.

Material and Methods

Between 2003 and 2007, 223 THAs (210 patients) with peripheral self-locking (PSL) cup and highly cross-linked polyethylene (Crossfire, Stryker, Mahwah, NJ) with minimum 5 years clinical and radiographic follow-up (5–9 years) were analyzed. The mean age was 62.5 years ± 10.8 (range, 32.7 – 86.3) at the time of surgery and the predominant preoperative diagnoses was osteoarthritis (97.8%). 72% were solid cups without screw augmentation and 28% were multi-hole with screw. Clinical analysis included Hospital for Special Surgery (HSS) hip scores at latest follow-up. Detail radiographic analysis was carried out on anteroposterior and false profile views for evidence of osseointegration in all Charnley's zones. Osseointegration was assessed based on presence of Stress Induced Reactive Cancellous Bone (SIRCaB) with trabecular bone hypertrophy 5–15mm extending from the cup, and absence of radiolucency or demarcation. EBRA software was used to assess cup positioning.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 357 - 357
1 Dec 2013
John T Shah G Lendhey M Ranawat A Ranawat CS
Full Access

Introduction

Total hip arthroplasty (THR) is one of the most successful procedures performed today. Uncemented acetabular components have by and large replaced cemented cups. As such, optimal fixation, bony ingrowth with longevity, and safety is highly demanded. In this study, we look at the safety and efficacy of the Stryker® Trident PSL™ acetabular component based on radiographic and clinical analysis.

Materials and Methods

We looked at 860 consecutive patients between 2003 and 2007. Of these, 231 consecutive patients had a minimum 5 year follow up. All cases were for degenerative joint disease (DJD), except 2 for dysplasia, 1 for avascular necrosis (AVN), 1 femoral neck nonunion. Average Hospital for Special Surgery (HSS) hip scores at final follow up were recorded. Radiographic analysis included classification based on Delee and Charnley's zones 1–3. Osseointegration was assessed based on presence of SIRCAB (stress induced reactive cortical hypertrophy of bone), demarcation around the implant, stress shielding, presence of radial trabeculae, absence of radiolucency, type of bearing, presence of preoperative protrusion, violation of Kohler's line. EBRA software was used to assess acetabular inclination and version.