Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_5 | Pages 3 - 3
1 Jul 2020
Chan G Aladwan R Hook S Rogers B Ricketts D Stott P
Full Access

Introduction

Dislocated hip hemiarthroplasties (HA) are associated with a 45% revision rate and 40% mortality rate.

Implant selection for HA operations vary with no universally accepted implant choice. The WHiTE3 trial suggested older designs such as the Thompson has equitable outcomes to more modern and expensive implants such as the Exeter V40+Unitrax.

Our multi-centre consecutive series of NOFs patients treated with HA assesses the impact of surgical and patient factors on dislocation risk.

Methods

Medical and radiographic records for patients treated between 1stJanuary 2009 and 30thSeptember 2017 with a HA at three acute hospitals were reviewed.

Implant and dislocation data were recorded. Patient demographics, comorbidities and operation details were extracted from the medical records and NHFD. Patients were excluded if there were no postoperative radiographs or when HA had been performed as a revision procedure.


The Bone & Joint Journal
Vol. 98-B, Issue 12 | Pages 1611 - 1619
1 Dec 2016
Wilson MJ Hook S Whitehouse SL Timperley AJ Gie GA

Aims

Femoral impaction bone grafting was first developed in 1987 using morselised cancellous bone graft impacted into the femoral canal in combination with a cemented, tapered, polished stem. We describe the evolution of this technique and instrumentation since that time.

Patients and Methods

Between 1987 and 2005, 705 revision total hip arthroplasties (56 bilateral) were performed with femoral impaction grafting using a cemented femoral stem. All surviving patients were prospectively followed for a mean of 14.7 years (9.8 to 28.3) with no loss to follow-up. By the time of the final review, 404 patients had died.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 53 - 53
1 Mar 2012
Hook S Melton J Wilson AJ Wandless F Thomas NP
Full Access

Improved surgical techniques and new fixation methods have revived interest in high tibial osteotomy surgery in recent years. Our aim was to review our first 59 cases. All patients underwent radiological and clinical review including pre and post operative scores.

Mean age at surgery was 43 (22-59) and mean follow up is 22 months.

The mean pre-operative limb alignment was 5.4° varus (range 1°-16°) with correction to 2° valgus (range -1° - 7°).

HTO is known to increase tibial slope and in this series the change in tibial slope from -5.2° (95%CI: -6.36 to -4.07)) to -7.8° (-8.83 to –6.89) was statistically significant. p= 0.0014 (Mann Whitney).

Patellar height is often reduced following opening wedge HTO and this is confirmed in our series. The Blackburne-Peel ratio changed from 0.74 to 0.58 and the Caton-Descamps from 0.83 to 0.7. Both were statistically significant at p<0.0001 and p=0.0001 respectively.

All scores improved post operatively, the knee injury and osteoarthritis outcome (KOOS) from 48 (8-91) to 73 (27-96), the Oxford knee score (OKS) from 25 (3-47) to 37 (9-48), and the EQ5D from 189809 (11221-32333) to 14138 (11111-22233) with the EQ5D VAS improving from 58 to 75. There was no correlation between change in limb alignment, tibial slope or patellar height and any of the scores used.

There were three superficial wound infections, and one non union which was treated with grafting and re fixation. Six patients have had their plate removed.

Improvement in clinical scores in these patients confirms that medial opening wedge HTO is a reliable joint preserving procedure in the short term and our surgical technique is reproducible and consistent with other published series.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 58 - 58
1 Feb 2012
Hook S Moulder E Burston B Yates P Whitley E Bannister G
Full Access

We reviewed 142 consecutive primary hip arthroplasties using the Exeter Universal femoral stem implanted between 1988 and 1993 into 123 patients. 74 patients with 88 hips survived to 10 years or more and were reviewed with a mean 12 years 8 months. There was no loss to follow-up and the fate of all stems is known.

Our stem revision rate for aseptic loosening and osteolysis was 1.1% (1 stem); stem revision for any cause was 2.2% (2 stems); and re-operation for any cause was 21.6% (19 hips), all but 2 of which were due to cup failure.

All but one stem subsided within the cement mantle to an average of 1.5mm at final follow-up (0 to 8mm). One stem was revised for deep infection and one was revised for excessive periarticular osteolysis. One further stem had subsided excessively (8mm) and demonstrated lucent lines at the stem-cement and cement-bone interfaces. This was classified as a radiological failure and is awaiting revision. 28% of stems had cement mantle defects, which were associated with increased subsidence (p=0.01), but were not associated with endosteal lysis or stem failure.

Periarticular osteolysis was significantly related with the degree of polyethylene wear (p<0.001), which was in turn associated with younger age patients (p=0.01) and males (p<0.001).

The Exeter metal backed cups were a catastrophic failure with 34% revised (11 cups) for loosening. The Harris Galante cups failed with excessive wear and osteolysis, with failure to revision of 18%. Only 1 cemented Elite cup was revised for loosening and osteolysis (4%).

The Exeter Universal stem implanted outside the originator centre has excellent medium term results.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 57 - 57
1 Feb 2012
Burston B Yates P Hook S Moulder E Bannister G
Full Access

Introduction

The success of total hip replacement in the young has consistently been worse both radiologically and clinically when compared to the standard hip replacement population.

Methods

We describe the clinical and radiological outcome of 58 consecutive polished tapered stems (PTS) in 47 patients with a minimum of 10 years follow-up (mean 12 years 6 months) and compared this to our cohort of standard patients. There were 22 CPT stems and 36 Exeter stems.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 503 - 504
1 Aug 2008
Burston B Yates P Hook S Moulder E Whitley E Bannister G
Full Access

The success of total hip replacement in the young has consistently been worse both radiologically and clinically when compared to the standard hip replacement population.

Methods: We describe the clinical and radiological outcome of 58 consecutive polished tapered stems (PTS) in 47 patients with a minimum of 10 years follow up (mean 12 years 6 months) and compared this to our cohort of standard patients. There were 22 CPT stems and 36 Exeter stems.

Results: Three patients with 4 hips died before 10 years and one hip was removed as part of a hindquarter amputation due to vascular disease. None of these stems had been revised or shown any signs of failure at their last follow-up. No stems were lost to follow up and the fate of all stems is known. Survivorship with revision of the femoral component for aseptic loosening as the endpoint was zero and 4% (2 stems) for potential revision. The Harris hip scores were good or excellent in 81% of the patients (mean score 86).

All the stems subsided within the cement to a mean total of 1.8mm (0.2–8) at final review. There was excellent preservation of proximal bone and an extremely low incidence of loosening at the cement bone interface. Cup failure and cup wear with an associated periarticular osteolysis was a serious problem. 19% of the cups (10) were revised and 25% of the hips (13) had significant periarticular osteolysis associated with excessive polyethylene wear.

Discussion: The outcome of polished tapered stems in this age group is as good as in the standard age group and superior to other non PTS designs in young patients. This is despite higher weight and frequent previous surgery. Cup wear and cup failure were significantly worse in this group, with a higher incidence of periarticular osteolysis.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 12 | Pages 1584 - 1590
1 Dec 2006
Hook S Moulder E Yates PJ Burston BJ Whitley E Bannister GC

We reviewed 142 consecutive primary total hip replacements implanted into 123 patients between 1988 and 1993 using the Exeter Universal femoral stem. A total of 74 patients (88 hips) had survived for ten years or more and were reviewed at a mean of 12.7 years (10 to 17). There was no loss to follow-up.

The rate of revision of the femoral component for aseptic loosening and osteolysis was 1.1% (1 stem), that for revision for any cause was 2.2% (2 stems), and for re-operation for any cause was 21.6% (19 hips). Re-operation was because of failure of the acetabular component in all but two hips.

All but one femoral component subsided within the cement mantle to a mean of 1.52 mm (0 to 8.3) at the final follow-up. One further stem had subsided excessively (8 mm) and had lucent lines at the cement-stem and cement-bone interfaces. This was classified as a radiological failure and is awaiting revision. One stem was revised for deep infection and one for excessive peri-articular osteolysis. Defects of the cement mantle (Barrack grade C and D) were found in 28% of stems (25 hips), associated with increased subsidence (p = 0.01), but were not associated with endosteal lysis or failure.

Peri-articular osteolysis was significantly related to the degree of polyethylene wear (p < 0.001), which was in turn associated with a younger age (p = 0.01) and male gender (p < 0.001).

The use of the Exeter metal-backed acetabular component was a notable failure with 12 of 32 hips (37.5%) revised for loosening. The Harris-Galante components failed with excessive wear, osteolysis and dislocation with 15% revised (5 of 33 hips). Only one of 23 hips with a cemented Elite component (4%) was revised for loosening and osteolysis.

Our findings show that the Exeter Universal stem implanted outside the originating centre has excellent medium-term results.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 242 - 242
1 May 2006
Hook S Bannister G Moulder E
Full Access

Introduction: Between 1988 and 1993 we performed 154 primary hip arthroplasties with the Exeter Universal femoral stem and a variety of acetabular components and describe our experience after a minimum follow up of 10.5 years (mean 12.6 years).

65 hips were assessed clinically and radiologically.

Our aim was to establish whether results from the inventing centre for the Exeter Universal stem were reproducible and to identify the features of cementing technique associated with survival of this prosthesis.

Results: At follow up the mean Oxford hip score was 24. Our stem revision rate was 1.7% and cup revision 13%. The majority of the cup failures occurred between 8 and 15 years and were the non flanged cemented metal backed Exeters which tended to both wear and migrate. We intend to revise 11 hips in 10 patients. 10 of these are for migration and or wear of the metal backed Exeter cup and one for distal stem-cement dissociation of the stem in a patient with thigh pain. Radiologically this stem showed migration and lucent lines at the cement-stem interface. 6% of stems had cement mantle defects, which were associated with endosteal lysis. Stem subsidence was related to Barrack’s grading for cementing technique. The worse the Barrack grade the more the prosthesis subsided within the cement mantle.

Conclusion: A complete cement mantle rather than 3rd generation cement compression is important for long term fixation of the femoral component. The Exeter universal stem is relatively forgiving of surgical technique. The cemented, collarless polished tapered device is suitable for general use and represents the reference standard for cemented femoral components.