Advertisement for orthosearch.org.uk
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 216 - 216
1 Mar 2013
Kazemi SM Besheli LD Eajazi A Reza M Sajadi M
Full Access

BACKGROUND

One of the complications of total knee arthroplasty (TKA) which has not yet been directly addressed is pseudo-patella baja (PPB). True patella baja (PB) is present when the length of the patellar tendon becomes shorter. PPB is present when the patella tendon is not shortened, but the level of the joint line is elevated. This study was conducted to assess PPB in TKA.

MATERIAL/METHODS

Sixty patients who had had a primary TKA at our center between 1995 and 2005 were included. The average follow-up was 27.5 months. The Knee Society Scoring (KSS), lateral knee x-rays and the Blackburne-Peel index were used for assessments.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 93 - 93
1 Mar 2013
Kazemi SM Mosaffa F Eajazi A Kaffashi M
Full Access

Total hip arthroplasty (THA) is associated with high intraoperative and postoperative blood loss. Antifibrinolytic drugs have been used to minimize the potential risks of bleeding and blood transfusion. Studies on the effect of tranexamic acid on decreasing blood loss in THA have revealed interesting results, but most have focused on cemented THA. Yet its benefits in THA, especially in cementless THA, have not been proved. We conducted a prospective double-blind randomized controlled study on 64 patients who were candidates for cementless THA under epidural anesthesia between 2006 and 2008. Patients were randomly assigned into study and control groups. Patients in both groups were well matched regarding preoperative characteristics. Five minutes preoperatively 32 patients of the study and control groups received 15 mg/kg tranexamic acid or normal saline intravenously respectively. Our findings showed a significantly smaller decrease in 6- and 24-hour postoperative hemoglobin levels, less intraoperative and postoperative bleeding, and less need for allogenic blood transfusion in the tranexamic acid group. Our results also revealed a higher mean of 6- and 24-hour hematocrit level and shorter hospital stay in the tranexamic acid group compared to the control group, which were not statistically meaningful. In our study no thromboembolic event was seen; except 1 patient in the control group. Our study showed that administering tranexamic acid before the start of cementless THA under epidural anesthesia can reduce intraoperative and postoperative bleeding as well as need for blood transfusion.