header advert
Results 1 - 12 of 12
Results per page:
Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_III | Pages 264 - 264
1 Mar 2003
Leet A Chhor K Kier-York J Sponseller P
Full Access

Introduction: We compared femoral head resection (FHR) and traction with femoral head resection and valgus osteotomy (the McHale procedure), in order to determine the effectiveness of these two procedures in the treatment of painful hip subluxation in severely involved individuals with cerebral palsy. Methods: Retrieval of demographic patient information, operative technique, post-operative complications, and migration of the femoral shaft was obtained from a retrospective review of charts and radiographs. Caregivers were then contacted by telephone and queried regarding post-operative changes in pain, sitting tolerance, and hygiene as well as overall satisfaction with surgical intervention. Results: 27 patients, 36 hips comprise the study cohort; 26 patients have quadriplegia, one has diplegia and is the only patient who is ambulatory. 16 patients underwent FHR, 11 patients underwent McHale procedures. The average age of surgery was 19 years, range from 8 to 42 years. Average follow-up was 3.4 years from time of surgery. The majority of patients (17) had not undergone reconstructive hip surgery because they were lost to orthopedic follow-up, and missed the opportunity to have the hip relocated before femur was significantly deformed. Six patients had painful hips despite previous attempts at surgery, three patients refused reconstructive surgery, and one patient was not deemed medically stable enough for reconstructive surgery. Post-operative complications were numerous and included skin breakdown, wound dehiscense, hardware infection or failure, heterotopic ossification, and death. The complication rate was significantly higher in patients who had undergone FHR and traction (13/16) compared with the patients who had a McHale procedure (3/11). The average length of hospitalization was almost twice as long for the FHR group (7 days) as for the McHale group (4 days). Telephone surveys of caregiv-ers often demonstrated equivalent overall satisfaction with surgery in both groups with average scores of 8/10 for the FHR and 7.6/10 for the McHale group (on a scale from 1 to 10, 10 being the most satisfied). Only two of the respondents (one from the FHR group, one McHale) we contacted regretted having had surgery. Caregivers felt that post-operatively pain relief was achieved in almost all patients. The average time to achieve a more pain-free state was three months. Sitting tolerance improved variably between individual patients, while few caregivers felt that hygiene improved after surgery, although they also felt that hygiene had not been a significant problem pre-operatively


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 137 - 143
1 Jan 2016
Hwang JH Varte L Kim HW Lee DH Park H

The aims of this study were to report functional outcomes of salvage procedures for patients with cerebral palsy (CP) who have chronic dislocation of the hip using validated scoring systems, and to compare the results of three surgical techniques.

We reviewed 37 patients retrospectively. The mean age at the time of surgery was 12.2 years (8 to 22) and the mean follow-up was 56 months (24 to 114). Patients were divided into three groups: 14 who underwent proximal femoral resection arthroplasty (PFRA group 1), ten who underwent subtrochanteric valgus osteotomy (SVO group 2), and 13 who underwent subtrochanteric valgus osteotomy with resection of the femoral head (SVO with FHR group 3). All patients were evaluated using the Caregiver Priorities and Child Health Index of Life with Disabilities (CPCHILD) and the Pediatric Quality of Life Inventory (PedsQL).

Significant improvements occurred in most CPCHILD and PedsQL subsection scores following surgery in all patients, without significant differences between the groups. There were 12 post-operative complications. Less severe complications were seen in group 1 than in groups 2 and 3.

Salvage surgery appears to provide pain relief in patients with CP who have painful chronic dislocation of the hip. The three salvage procedures produced similar results, however, we recommend the use of PFRA as the complications are less severe.

Take home message: Salvage surgery can be of benefit to patients with CP with chronic painful hip dislocation, but should be limited to selected patients considering complications.

Cite this article: Bone Joint J 2016;98-B:137–43.


Introduction. Patient-specific cutting guides entered into clinical practice few years ago, first introduced in total knee replacement and recently also for other joint replacements. Advantages claimed are improving accuracy and repeatability in implant placement. New patient-specific guides to perform an accurate femoral neck resection and provide a precise alignment reference for acetabular reaming in total hip arthroplasty (THA) were recently developed by Medacta International: MyHip Technology. To date femoral guides can be designed for both anterior and posterior approaches, whereas acetabular guides are available only for posterior approach. Evaluation of the repeatability and reproducibility of MyHip guides placement on cadavers is performed using a navigation system. Accuracy of femoral MyHip guides is evaluated also through one author's clinical experience (RP). Materials and Methods. During each cadaveric session one body (2 hips) was available. A pre-operative CT scan has been obtained and used in order to create the 3D bone model of the pelvis and proximal femurs. Afterwards, a surgical planning for THA has been performed for each case, and, once it was approved by the surgeons, the designed patient-specific blocks were made. Intraobserver and interobserver agreement in positioning the guides was assessed getting measures of femoral head resection height (mm), femoral head plane inclination/anteversion (°) and acetabular reaming axis orientation (°). 9 surgeons, through 2 cadaveric sessions, positioned each guide, removed it and re-positioned it 5 times alternatively. The system is judged as accurate if all measures differ less than 3mm and 5°for lengths and angles respectively from the average among all the acquisitions. Clinical experience includes 68 THA which were performed between March 2014 and April 2015. Anterior femoral MyHip guides were used for the femoral head resection, while the acetabular side was prepared using the standard metal instrumentation for minimally invasive anterior approach. Intra-operative complications, as well post-operative leg length difference and implant positioning are assessed. Results. During cadaveric sessions, all measures taken meet the acceptance criteria with the exception of two measures, which are −5,98° and −5,57°, in femoral head plane anteversion and inclination respectively with femoral anterior guides. Looking at intraobserver variation, MyHip Femoral anterior guide positioning average deviation was between −0.91 mm and 1.44 mm (resection height), −1.25° and 1.41° (anteversion), and −0.85° and 0.82° (inclination); MyHip Femoral posterior guide positioning average deviation was between −0.47 mm and 0.67 mm (resection height), −1.33° and 1.50° (anteversion), −0.66° and 1.50° (inclination); MyHip Acetabular posterior guide had an average z-axis deviation from the mean value between −0.91° and 0.91°. All surgeries were successfully performed. The surgeon feels a good fitting and stability of the guide during each surgery. A preliminary analysis suggests optimal outcomes in terms of accurate prosthetic component positioning and reduction of occurrence of leg length inequality. Conclusion. Cadaveric sessions show intraobserver and intraobserver agreement, demonstrating reproducibility and repeatability in placement of MyHip patient specific cutting guides. Clinical experience confirms the advantages claimed by this technique, suggesting a possible reduction of complications usually linked to implant malpositioning, such as wear, impingement, risk of luxation


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 454 - 454
1 Nov 2011
Matsuura Ohashi H Okamoto Y Okajima Y Kataoka T Tashima H Kitano K
Full Access

Direct anterior approach (DAA) is an inter-muscular approach that needs no muscle detached. In THA through DAA approach, exposure of the acetabulum is facilitated, while the key points of this approach are femoral lift-up and hip extension to get sufficient access to the femoral canal. To investigate the strategy for femoral lift-up, we released the capsule step by step and measured the distance of femoral lift-up at each step in cadavers and clinical cases. The effects of hip extension on femoral lift-up were also evaluated. Three fresh frozen cadavers were used. In supine position, the hip joint was exposed through DAA by two experienced surgeons. After anterior capsulotomy and femoral head resection, posterior capsule release was performed followed by superior capsule release in one side, and superior release was followed by posterior release in the other side. Finally, internal obturator muscle was released in both side. At each step, the distance of femoral lift-up was measured under the traction force of 70N. The effects of hip extension were investigated in 0, 15 and 25 degrees hyper-extension. Thirty-six THA were performed through DAA. Posterior capsule release was performed followed by superior capsule release in 13 hips, and superior release was followed by posterior release in 23 hips. At each step, the distance of femoral lift-up was measured under the traction force of 70N at each step same as the cadaver study. In cadaver study, anterior capsulotomy and posterior capsule release affected little the femoral lift-up. The distance increased after superior capsular release. The distance decreased as hip hyperextension unless the superior capsule was released. The effect of internal obturator muscle release was not observed. In clinical studies, the same tendency was observed in clinical cases. Superior capsule release was the most effective for the femoral lift-up. The results of this study indicate that superior capsule release is the first step for the femoral liftup. The second step is hip extension to get access to the femoral canal. By performing these procedures step by step, rasping and stem insertion can be achieved with minimal soft tissue release


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIV | Pages 71 - 71
1 Oct 2012
Bäthis H Shafizadeh S Banerjee M Tjardes T Bracke B Neubauer T Bouillon B
Full Access

In order to enhance the acceptance of computer assisted surgery in joint replacement, a development-cooperation with BrainLAB, Germany was set up to develop a user-friendly handheld navigation device. A sterile draped Apple® IPod-Touch which is placed into a hardcover cradle, is used as navigation monitor and touchscreen control. Different instruments, such as navigation-pointer are attached to the cradle. In addition the workflows for TKR and THR procedures have been optimised. Therefore the main focus for TKR is navigation of femoral and tibial resection as well as leg alignment control. For the THR the system enables an intraoperative control of leg-length and femoral-offset measurement in comparison with the preoperative situation. Each step of the procedure is supported by video animations of the specific navigation workflow. Between September and December 2010 the first clinical study on the usability in TKR and THR was performed for 20 cases using a prototype system. The study was approved by the local ethic committee and the “German Federal Institute for Drugs and Medical Devices (BfArM)”. Special interest was taken to the aspects of usability and the necessary time periods for specific steps of the procedure. Usability was measured for specific time periods of the procedure assessment of the usability of the surgical team. In addition postoperative x-rays were evaluated for implant position, leg alignment for TKR and hip joint geometry for THR cases. Throughout the study for each assigned patient the procedure could be performed as planned. Several design inputs were identified for further improvement of the final system. Therefore time measurements of the first five cases were excluded. For the TKR cases the registration process of the last 5 cases was less than 3 minutes. The interval for the tibial resection was between 3 and 7 minutes (aligning tibial cutting block – end of tibial verification). The interval for the distal femur resection was between 7 and 11 minutes (aligning femoral cutting block – end of femoral verification). All 10 Patients showed a final leg alignment on the postoperative standing x-ray within the save-zone of +/− 3° from neutral alignment. For the THR cases the preoperative registration period including the femoral head resection and acetabular registration was between 7 and 12 Minutes. Each final measurement of the hip geometry was done in less than 2 minutes. The evaluation of the pelvic ap-x-ray pre- and postoperative showed equivalent measurements of the new hip geometry compared with the intraoperative measured values. No specific complications occurred throughout the study. In conclusion the BrainLAB–DASH-System has shown a high grade of usability and very short learning curve within this first clinical study. The use of a standard Apple® IPod-touch as a user interface seems to enhance the acceptance of the navigation technique. Equivalent precision compared to standard navigation systems have been demonstrated


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 81 - 81
1 Jan 2018
Fürnstahl P Lanfranco S Leunig M Ganz R
Full Access

Severe femoral head deformities due to Perthes' disease are characterized by limitation of ROM, pain, and early degeneration, eventually becoming intolerable already in early adulthood. Morphological adaptation of the acetabulum is substantial and complex intra- and extraarticular impingement sometimes combined with instability are the underlying pathologies. Improvement is difficult to achieve with classic femoral and acetabular osteotomies. Since 15 years we have executed a head size reduction. With an experience of more than 50 cases no AVN of the femoral head was recorded. In two hips fracture of the medial column of the neck has been successfully treated with subsequent screw fixation. The clinical mid-term results are characterized by substantial increase of hip motion and pain reduction. Surgical goal is to obtain a smaller head, well contained in the acetabulum. It should become as spherical as possible and the gliding surface should be covered with best available cartilage. Together, it has to be accomplished under careful consideration of the blood supply to the femoral head. In the majority of cases acetabular reorientation is necessary to optimize joint stability. Femoral head segment resections without guidance is difficult. Therefore, 3D-simulation for cut direction and segment size including the implementation of the resultant osteotomy configuration was developed using individually manufactured cutting jigs. First experience in five such cases have revealed good results. The forthcoming steps are the improvement of computer algorithm and automation. Goal is that with first cut decision the other cuts are automatically determined resulting in optimal head size and sphericity


The Bone & Joint Journal
Vol. 103-B, Issue 1 | Pages 198 - 203
1 Jan 2021
Min JJ Kwon S Sung KH Lee KM Chung CY Park MS

Aims

Hip displacement, common in patients with cerebral palsy (CP), causes pain and hinders adequate care. Hip reconstructive surgery (HRS) is performed to treat hip displacement; however, only a few studies have quantitatively assessed femoral head sphericity after HRS. The aim of this study was to quantitatively assess improvement in hip sphericity after HRS in patients with CP.

Methods

We retrospectively analyzed hip radiographs of patients who had undergone HRS because of CP-associated hip displacement. The pre- and postoperative migration percentage (MP), femoral neck-shaft angle (NSA), and sphericity, as determined by the Mose hip ratio (MHR), age at surgery, Gross Motor Function Classification System level, surgical history including Dega pelvic osteotomy, and triradiate cartilage status were studied. Regression analyses using linear mixed model were performed to identify factors affecting hip sphericity improvement.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 243 - 243
1 Jul 2008
BEAUL P CAMPBELL P HOKE R
Full Access

Purpose of the study: During resurfacing arthroplasty, excessive valgus of the femoral neck or an insufficient surgical technique can lead to formation of a notch in the femoral head. Although the mechanisms weakening the femoral neck and subsequent fractures are well described, the effects of altered blood supply via the retinacular vessels on potential ischemia of the femoral head are largely unknown. The purpose of our study was to assess blood supply to the femoral head when a notch occurred in the femoral neck during total hip replacement surgery and to deduct possible implications concerning the resurfacing procedure. Material and methods: Blood supply to the femoral head was measured with laser Doppler fluorometry in 14 hips undergoing total hip replacement for osteoarthritis via a lateral approach with anterior dislocation. An optical laser probe for the fluorometry (Moor Instruments, Wilmington Delewar, 20 mW laser, probe length 780 nm) was introduced via a 3.5 mm hole drilled in the antrolaeral quadrant of the femoral head (leg in neutral position). The position of the probe was checked on the x-ray of the femoral head after resection. A notch was simulated in the lateral posterior portion of the femoral neck using a bone gouge. Results: Mean patient age was 65 years (range 48–77 years). There were eight men and six women. Two measurements were made: one after dislocation of the hip and the second after simulating the notch. A significant decrease in blood supply measured at more than 50% was observed in all but four hips after simulating the notch. The median decrease in blood flow was 76% (4.4–90.4, p< 0.001). Conclusion: The retinacular vessels appear to be equally important for the blood supply for osteoarthritic and non-osteoarthritic femoral heads. A notch occurring during hip resurfacing would not only weaken the mechanical resistance of the neck but would also increase the risk of osteonecrosis and subsequent loosening of the femoral component. Consequently, approaches compromising retinacular blood supply (for example the posterior approach) would add a supplementary danger for the integrity and viability of the femoral head


Bone & Joint 360
Vol. 3, Issue 3 | Pages 34 - 37
1 Jun 2014

The June 2014 Children’s orthopaedics Roundup360 looks at: plaster wedging in paediatric forearm fractures; the medial approach for DDH; Ponseti – but not as he knew it?; Salter osteotomy more accurate than Pemberton in DDH; is the open paediatric fracture an emergency?; bang up-to-date with femoral external fixation; indomethacin, heterotopic ossification and cerebral palsy hips; lengthening nails for congenital femoral deformities, and is MRI the answer to imaging of the physis?


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 8 | Pages 1007 - 1012
1 Aug 2009
Egermann M Döderlein L Schläger E Müller S Braatz F

In patients with severe quadriplegic cerebral palsy and painful hip dislocation proximal femoral resection arthroplasty can reduce pain, but the risk of heterotopic ossification is significant. We present a surgical technique of autologous capping of the femoral stump in order to reduce this risk, using the resected femoral head as the graft.

A retrospective study of 31 patients (43 hips) who had undergone proximal femoral resection arthroplasty with (29 hips) and without autologous capping (14 hips) was undertaken. Heterotopic ossification was less frequent in patients with autologous capping, and a more predictable pattern of bony overgrowth was found.

For a selected group of non-ambulatory patients with long-standing painful dislocation of the hip, we recommend femoral resection arthroplasty over more complicated reconstructive operations. The risk of heterotopic ossification, which is a major disadvantage of this operation, is reduced by autologous capping.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 5 | Pages 617 - 623
1 May 2010
McNamara I Deshpande S Porteous M

The clinical and radiological results of 50 consecutive acetabular reconstructions in 48 patients using impaction grafting have been retrospectively reviewed. A 1:1 mixture of frozen, ground irradiated bone graft and Apapore 60, a synthetic bone graft substitute, was used in all cases. There were 13 complex primary and 37 revision procedures with a mean follow-up of five years (3.4 to 7.6). The clinical survival rate was 100%, with improvements in the mean Harris Hip Scores for pain and function. Radiologically, 30 acetabular grafts showed evidence of incorporation, ten had radiolucent lines and two acetabular components migrated initially before stabilising.

Acetabular reconstruction in both primary and revision surgery using a 1:1 mixture of frozen, ground, irriadiated bone and Apapore 60 appears to be a reliable method of managing acetabular defects. Longer follow-up will be required to establish whether this technique is as effective as using fresh-frozen allograft.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 12 | Pages 1586 - 1591
1 Dec 2007
Flecher X Parratte S Aubaniac J Argenson J

A clinical and radiological study was conducted on 97 total hip replacements performed for congenital hip dislocation in 79 patients between 1989 and 1998 using a three-dimensional custom-made cementless stem. The mean age at operation was 48 years (17 to 72) and the mean follow-up was for 123 months (83 to 182).

According to the Crowe classification, there were 37 class I, 28 class II, 13 class III and 19 class IV hips. The mean leg lengthening was 25 mm (5 to 58), the mean pre-operative femoral anteversion was 38.6° (2° to 86°) and the mean correction in the prosthetic neck was −23.6° (−71° to 13°). The mean Harris hip score improved from 58 (15 to 84) to 93 (40 to 100) points. A revision was required in six hips (6.2%). The overall survival rate was 89.5% (95% confidence interval 89.2 to 89.8) at 13 years when two hips were at risk.

This custom-made cementless femoral component, which can be accommodated in the abnormal proximal femur and will correct the anteversion and frontal offset, provided good results without recourse to proximal femoral corrective osteotomy.