Advertisement for orthosearch.org.uk
Results 1 - 90 of 90
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 1 | Pages 127 - 133
1 Jan 2022
Viberg B Pedersen AB Kjærsgaard A Lauritsen J Overgaard S

Aims. The aim of this study was to assess the association of mortality and reoperation when comparing cemented and uncemented hemiarthroplasty (HA) in hip fracture patients aged over 65 years. Methods. This was a population-based cohort study on hip fracture patients using prospectively gathered data from several national registries in Denmark from 2004 to 2015 with up to five years follow-up. The primary outcome was mortality and the secondary outcome was reoperation. Hazard ratios (HRs) for mortality and subdistributional hazard ratios (sHRs) for reoperations are shown with 95% confidence intervals (CIs). Results. A total of 17,671 patients with primary HA were identified (9,484 uncemented and 8,187 cemented HAs). Compared to uncemented HA, surgery with cemented HA was associated with an absolute risk difference of 0.4% for mortality within the period zero to one day after surgery and an adjusted HR of 1.70 (95% CI 1.22 to 2.38). After seven days, there was no longer any association, with an adjusted HR of 1.07 (95% CI 0.90 to 1.28). This continued until five years after surgery with a HR of 1.01 (95% CI 0.96 to 1.06). There was a higher proportion of reoperations due to any reason after five years in the uncemented group with 10.2% compared to the cemented group with 6.1%. This yielded an adjusted sHR of 0.65 (95% CI 0.57 to 0.75) and difference continued up until five years after the surgery, demonstrating a sHR of 0.70 (95% CI 0.59 to 0.83). Conclusion. In a non-selected cohort of hip fracture patients, surgery with cemented HA was associated with a higher relative mortality during the first postoperative day compared to surgery with uncemented HA, but there was no difference after seven days up until five years after. In contrast, surgery with cemented HA was associated with lower risk of reoperation up to five years postoperatively compared with surgery with uncemented HA. There was a higher relative mortality on the first postoperative day for cemented HA versus uncemented HA. There was no difference in mortality after seven days up until five years after surgery. There were 6.1% reoperations for cemented HA compared to 10.2% for uncemented HA after five years. Cite this article: Bone Joint J 2022;104-B(1):127–133


The Bone & Joint Journal
Vol. 106-B, Issue 7 | Pages 656 - 661
1 Jul 2024
Bolbocean C Hattab Z O'Neill S Costa ML

Aims. Cemented hemiarthroplasty is an effective form of treatment for most patients with an intracapsular fracture of the hip. However, it remains unclear whether there are subgroups of patients who may benefit from the alternative operation of a modern uncemented hemiarthroplasty – the aim of this study was to investigate this issue. Knowledge about the heterogeneity of treatment effects is important for surgeons in order to target operations towards specific subgroups who would benefit the most. Methods. We used causal forest analysis to compare subgroup- and individual-level treatment effects between cemented and modern uncemented hemiarthroplasty in patients aged > 60 years with an intracapsular fracture of the hip, using data from the World Hip Trauma Evaluation 5 (WHiTE 5) multicentre randomized clinical trial. EuroQol five-dimension index scores were used to measure health-related quality of life at one, four, and 12 months postoperatively. Results. Our analysis revealed a complex landscape of responses to the use of a cemented hemiarthroplasty in the 12 months after surgery. There was heterogeneity of effects with regard to baseline characteristics, including age, pre-injury health status, and lifestyle factors such as alcohol consumption. This heterogeneity was greater at the one-month mark than at subsequent follow-up timepoints, with particular regard to subgroups based on age. However, for all subgroups, the effect estimates for quality of life lay within the confidence intervals derived from the analysis of all patients. Conclusion. The use of a cemented hemiarthroplasty is expected to increase health-related quality of life compared with modern uncemented hemiarthroplasty for all subgroups of patients aged > 60 years with a displaced intracapsular fracture of the hip. Cite this article: Bone Joint J 2024;106-B(7):656–661


The Bone & Joint Journal
Vol. 102-B, Issue 9 | Pages 1113 - 1121
14 Sep 2020
Nantha Kumar N Kunutsor SK Fernandez MA Dominguez E Parsons N Costa ML Whitehouse MR

Aims. We conducted a systematic review and meta-analysis to compare the mortality, morbidity, and functional outcomes of cemented versus uncemented hemiarthroplasty in the treatment of intracapsular hip fractures, analyzing contemporary and non-contemporary implants separately. Methods. PubMed, Medline, EMBASE, CINAHL, and Cochrane Library were searched to 2 February 2020 for randomized controlled trials (RCTs) comparing the primary outcome, mortality, and secondary outcomes of function, quality of life, reoperation, postoperative complications, perioperative outcomes, pain, and length of hospital stay. Relative risks (RRs) and mean differences (with 95% confidence intervals (CIs)) were used as summary association measures. Results. A total of 18 studies corresponding to 16 non-overlapping RCTs with a total of 2,819 intracapsular hip fractures were included. Comparing contemporary cemented versus uncemented hemiarthroplasty, RRs (95% CIs) for mortality were 1.32 (0.44 to 3.99) perioperatively, 1.01 (0.48 to 2.10) at 30 days, and 0.90 (0.71 to 1.15) at one year. The use of contemporary cemented hemiarthroplasty reduced the risk of intra- and postoperative periprosthetic fracture. There were no significant differences in the risk of other complications, function, pain, and quality of life. There were no significant differences in perioperative outcomes except for increases in operating time and overall anaesthesia for contemporary cemented hemiarthroplasty with mean differences (95% CIs) of 6.67 (2.65 to 10.68) and 4.90 (2.02 to 7.78) minutes, respectively. The morbidity and mortality outcomes were not significantly different between non-contemporary cemented and uncemented hemiarthroplasty. Conclusion. There are no differences in the risk of mortality when comparing the use of contemporary cemented with uncemented hemiarthroplasty in the management of intracapsular hip fractures. Contemporary cemented hemiarthroplasty is associated with a substantially lower risk of intraoperative and periprosthetic fractures. Cite this article: Bone Joint J 2020;102-B(9):1113–1121


The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 922 - 928
1 Aug 2022
Png ME Petrou S Fernandez MA Achten J Parsons N McGibbon A Gould J Griffin XL Costa ML

Aims. The aim of this study was to compare the cost-effectiveness of cemented hemiarthroplasty (HA) versus hydroxyapatite-coated uncemented HA for the treatment of displaced intracapsular hip fractures in older adults. Methods. A within-trial economic evaluation was conducted based on data collected from the World Hip Trauma Evaluation 5 (WHiTE 5) multicentre randomized controlled trial in the UK. Resource use was measured over 12 months post-randomization using trial case report forms and participant-completed questionnaires. Cost-effectiveness was reported in terms of incremental cost per quality-adjusted life year (QALY) gained from the NHS and personal social service perspective. Methodological uncertainty was addressed using sensitivity analysis, while decision uncertainty was represented graphically using confidence ellipses and cost-effectiveness acceptability curves. Results. The base-case analysis showed that cemented implants were cost-saving (mean cost difference -£961 (95% confidence interval (CI) -£2,292 to £370)) and increased QALYs (mean QALY difference 0.010 (95% CI 0.002 to 0.017)) when compared to uncemented implants. The probability of the cemented implant being cost-effective approximated between 95% and 97% at alternative cost-effectiveness thresholds held by decision-makers, and its net monetary benefit was positive. The findings remained robust against all the pre-planned sensitivity analyses. Conclusion. This study shows that cemented HA is cost-effective compared with hydroxyapatite-coated uncemented HA in older adults with displaced intracapsular hip fractures. Cite this article: Bone Joint J 2022;104-B(8):922–928


The Bone & Joint Journal
Vol. 102-B, Issue 1 | Pages 11 - 16
1 Jan 2020
Parker MJ Cawley S

Aims. Debate continues about whether it is better to use a cemented or uncemented hemiarthroplasty to treat a displaced intracapsular fracture of the hip. The aim of this study was to attempt to resolve this issue for contemporary prostheses. Methods. A total of 400 patients with a displaced intracapsular fracture of the hip were randomized to receive either a cemented polished tapered stem hemiarthroplasty or an uncemented Furlong hydroxyapatite-coated hemiarthroplasty. Follow-up was conducted by a nurse blinded to the implant at set intervals for up to one year from surgery. Results. A total of 115 patients died in the year after surgery. There was a tendency towards a slightly higher mortality in those treated with the uncemented prosthesis after one year (64 vs 51; p = 0.18). For the survivors, there was no significant difference in pain score at any of the time intervals. Patients treated using the cemented hemiarthroplasty recovered mobility better than those treated with the uncemented hemiarthroplasty (mean decrease in mobility score at one year: 1.7 vs 1.1, SD 1.9; p = 0.008). There was a tendency to more periprosthetic fractures in the uncemented group (five vs two cases; p = 0.45), but overall the need for further surgery was similar in both groups (nine vs seven cases). There were four perioperative deaths in the cemented group. Conclusion. These results indicate that a contemporary cemented hemiarthroplasty gives better results than an uncemented hemiarthroplasty for patients with a displaced intracapsular fracture of the hip. When the condition of the patient permits, a cemented hemiarthroplasty should be used. Cite this article: Bone Joint J. 2020;102-B(1):11–16


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_6 | Pages 9 - 9
1 May 2019
Dasaraju P Parker M
Full Access

Continued controversy exists between cemented versus uncemented hemiarthroplasty for an intracapsular hip fracture. To assist in resolving this controversy, 400 patients were randomised between a cemented polished tapered stem hemiarthroplasty and an uncemented Furlong hydroxyapatite coated hemiarthroplasty. Follow-up was by a nurse blinded to the implant used for up to three years from surgery. Results indicate no difference in the pain scores between implants but a tendency to an improved regain of mobility for those treated with the cemented arthroplasty (1.2 score versus 1.7 at 6 months, p=0.03). There was no difference in early mortality but a tendency to a higher later mortality for the uncemented implants (29% versus 24% at one year, p=0.3). Later peri-prosthetic fracture was more common in the uncemented group (3% versus 1.5%). Revision arthroplasty was required for 2% of cemented cases and 3% of uncemented cases. Surgery for an uncemented hemiarthroplasty was 5 minutes shorter but these patients were more likely to need a blood transfusion (14% versus 7%). Three patients in the cemented group had a major adverse reaction to bone cement leading to their death. These results indicated that a cemented stem hemiarthroplasty give marginally improved regain of mobility in comparison to a contemporary uncemented hemiarthroplasty. An uncemented hemiarthroplasty still has a place for those considered to be at a high risk of bone cement implantation syndrome


Bone & Joint Open
Vol. 1, Issue 3 | Pages 13 - 18
1 Mar 2020
Png ME Fernandez MA Achten J Parsons N McGibbon A Gould J Griffin X Costa ML

Aim. This paper describes the methods applied to assess the cost-effectiveness of cemented versus uncemented hemiarthroplasty among hip fracture patients in the World Hip Trauma Evaluation Five (WHiTE5) trial. Methods. A within-trial cost-utility analysis (CUA) will be conducted at four months postinjury from a health system (National Health Service and personal social services) perspective. Resource use pertaining to healthcare utilization (i.e. inpatient care, physiotherapy, social care, and home adaptations), and utility measures (quality-adjusted life years) will be collected at one and four months (primary outcome endpoint) postinjury; only treatment of complications will be captured at 12 months. Sensitivity analysis will be conducted to assess the robustness of the results. Conclusion. The planned analysis strategy described here records our intent to conduct a within-trial CUA alongside the WHiTE5 trial


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXI | Pages 61 - 61
1 May 2012
F. T M. W
Full Access

Introduction. The treatment of displaced femoral neck fractures in elderly patients is under debate. Hemiarthroplasty is a recognised treatment for elderly patients with reduced capacity for mobilisation. Controversy exists around cemented or uncemented implants for hemiarthroplasty in this population. The aim of this study is to investigate outcomes of cemented vs uncemented hemiarthroplasty implants to two years post operation. Methods. All elderly patients presenting to one institution with a displaced subcapital neck of femur fracture were offered inclusion. One hundred and sixty patients (mean age, 85 years) with acute displaced femoral neck fractures were randomly allocated to be treated with cemented Exeter, or uncemented Zweymüller Alloclassic Hemiarthroplasty. Clinical and radiologic follow-up to two years with the main outcome measurements being pain, mortality, mobility, complications, reoperations, and quality of life using validated scores recorded by a blinded outcome assessor. Results. Complication rates were more frequent in uncemented implants (p< 0.016). Subsidence and perioperative fracture were significantly higher with uncemented components (p< 0.05). Visual analogue pain scores at rest were not significantly different between each group. Mortality rates were not significantly different at any time point. Oxford Hip scores at 6 weeks favoured cemented implants (p< 0.05). These trends persist but are not significant at later follow-up. Mobility measured by a timed up-and-go score favoured cemented at 6 weeks (p< 0.01), 6 months (p< 0.05) and 1 year (p< 0.005). A trend towards less dependence on walking aids also favoured cemented implants. Multifunctional assessment index and Mini-mental scores were similar in each group. Conclusion. Cemented hemiarthroplasty provides a better outcome for elderly patients with a displaced femoral neck fracture when compared with uncemented hemiarthroplasty. Complication rates were significantly lower and function and pain scores were improved at multiple time points following surgery


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 256 - 256
1 Jul 2011
Costain D Whitehouse SL Pratt NL Graves SE Crawford RW
Full Access

Purpose: The appropriate means of fixation for hemiarthroplasty of the hip is a matter of ongoing debate. Proponents of uncemented components cite the risk of perioperative mortality with cement implantation as justification for avoiding cement in certain patients. Because cement-related mortality is rare, we wished to compare the incidence of perioperative mortality in patients receiving cemented versus uncemented hemiarthroplasty using a large national database. Further, we wished to compare overall revision rate between fixation methods to assess their role in implant survivorship. Method: All recorded hemiarthroplasty cases from the AOA National Joint Replacement Registry were cross-referenced to the Australian mortality data, and deaths at 1d, 7d, 28d, and one year were compared between groups. Further, subgroup analysis of monoblock, modular, and bipolar hemiarthroplasty were compared as a surrogate measure of different patient populations. Results: Comparing all hemiarthroplasty procedures as a group, there was a a significantly increased mortality rate at day one post-operatively (p = 0.0005) when cement was used. By day 7, this trend reversed, revealing a reduced mortality risk with cement (p = 0.02). This trend reversal persisted at day 28 and one year post-operatively (p = 0.028 & p < 0.0001, respectively). With subgroup analysis, monoblock hemiarthroplasty revealed a similar trend reversal in early versus late mortality. Modular and bipolar hemiarthroplasty procedures failed to reveal a significant difference in mortality when cemented and uncemented components were compared at all time points. When fixation method was compared in different age groups, a favourable mortality rate was seen at one year when cemented monoblock components were used in patients aged 71–80, and in patients ≥81 years old (p = 0.005 & < 0.001, respectively). The opposite was true with cemented modular implants at one year in patients < 70 years old (p = 0.009). There was no significant difference in mortality between cemented and uncemented implants in any other age investigated. Revision rates were significantly higher in patients treated with uncemented hemiarthroplasty regardless of prosthesis type. Conclusion: This study demonstrates a higher overall success rate, and comparable or reduced long-term mortality risk when cement is used in hip hemiarthroplasty


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 29 - 29
1 Sep 2012
Jameson S James P Rangan A Muller S Reed M
Full Access

Background. In 2011 20% of intracapsular fractured neck of femurs were treated with an uncemented hemiarthroplasty in the English NHS. National guidelines recommend cemented implants, based on evidence of less pain, better mobility and lower costs. We aimed to compare complications following cemented and uncemented hemiarthroplasty using the national hospital episode statistics (HES) database in England. Methods. Dislocation, revision, return to theatre and medical complications were extracted for all patients with NOF fracture who underwent either cemented or uncemented hemiarthroplasty between January 2005 and December 2008. To make a ‘like for like’ comparison all 30424 patients with an uncemented impant were matched to 30424 cemented implants (from a total of 42838) in terms of age, sex and Charlson co-morbidity score. Results. In patients with an uncemented implant, 18-month revision (1.62% versus 0.57% (OR 2.90 [2.44–3.45], p< 0.001)), 4-year revision (2.45% vs 1.11% (OR 2.28 [1.45–3.65], p< 0.001)) and 30-day chest infection (8.14% versus 7.23% (OR 1.14 [1.08–1.21], p=0.028)) were significantly higher. Interestingly, 4-year dislocation rate was higher in cemented implants (0.60% versus 0.26% (OR 0.45 [0.36–0.55], p< 0.001). No significant differences were seen in 30-day return to theatre, myocardial infarction, cerebrovascular event or 90-day pulmonary embolus. Discussion. In this national analysis of matched patients short and medium term revision rate, and perioperative chest infection was significantly higher in the uncemented group. This supports the published evidence and national guidelines recommending cement fixation of hemiarthroplasty


The Bone & Joint Journal
Vol. 105-B, Issue 11 | Pages 1196 - 1200
1 Nov 2023
Parker MJ Chatterjee R Onsa M Cawley S Gurusamy K

Aims

The aim of this study was to report the three-year follow-up for a series of 400 patients with a displaced intracapsular fracture of the hip, who were randomized to be treated with either a cemented polished tapered hemiarthroplasty or an uncemented hydroxyapatite-coated hemiarthroplasty.

Methods

The mean age of the patients was 85 years (58 to 102) and 273 (68%) were female. Follow-up was undertaken by a nurse who was blinded to the hemiarthroplasty that was used, at intervals for up to three years from surgery. The short-term follow-up of these patients at a mean of one year has previously been reported.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_I | Pages 47 - 47
1 Mar 2005
Shetty RR Singh R Singh G Karunanithy N Edwards M Sinha S Mostofi SB Khan F
Full Access

In this study, we reviewed the records of 881 patients with fracture neck of femur over 5 years. Of these, 372 patients underwent hemiarthroplasty (231 cemented and 141 uncemented). The aim was to analyse the factors, which may contribute towards the mortality in cemented versus uncemented group. The mean age in the cemented and uncemented group was 82 and 81 years respectively. 136 (58.8%) patients were operated within 24 hours of admission in the cemented group as compared to 63 (44.6%). The mean operative time was 81minutes for cemented hemiarthroplasty and 61 minutes for uncemented hemiarthroplasty. 77% of the cemented hemiarthroplasty was performed by Registrar grade as compared to 69% in the uncemented group. Of the 231 patients in the cemented group, 52% received general and 48% received spinal anaesthesia. Of the 141 patients in the uncemented group, 30% received general and 70% received spinal anaesthesia. There was an 8% 30-day mortality compared to 11% 30-day mortality in uncemented group (p< 0.05). The mean age of patients in the mortality group was age 86 yrs in cement and 84 yrs in uncemented group. Most operations were done within 24–48 hours. There was significant co morbidity in patients who died. The average operative time of patients who died in both groups was same. There was an increased mortality rate in the uncemented group as compared to the cemented group (p< 0.05). Based on our study, we conclude that cement is not a risk factor. Duration and timing of surgery is not associated with increased mortality. There was no difference in 30-day mortality rates between patients receiving general or spinal anaesthesia. Significant co morbid factor is associated with increased mortality


The Bone & Joint Journal
Vol. 99-B, Issue 4 | Pages 421 - 431
1 Apr 2017
Veldman HD Heyligers IC Grimm B Boymans TAEJ

Aims

Our aim was to prepare a systematic review and meta-analysis to compare the outcomes of cemented and cementless hemiarthroplasty of the hip, in elderly patients with a fracture of the femoral neck, to investigate the mortality, complications, length of stay in hospital, blood loss, operating time and functional results.

Materials and Methods

A systematic review and meta-analysis was conducted following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines on randomised controlled trials (RCTs), studying current generation designs of stem only. The synthesis of results was done of pooled data, with a fixed effects or random effects model, based on heterogeneity.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 1 | Pages 116 - 122
1 Jan 2010
Parker MI Pryor G Gurusamy K

We undertook a prospective randomised controlled trial involving 400 patients with a displaced intracapsular fracture of the hip to determine whether there was any difference in outcome between treatment with a cemented Thompson hemiarthroplasty and an uncemented Austin-Moore prosthesis. The surviving patients were followed up for between two and five years by a nurse blinded to the type of prosthesis used.

The mean age of the patients was 83 years (61 to 104) and 308 (77%) were women. The degree of residual pain was less in those treated with a cemented prosthesis (p < 0.0001) three months after surgery. Regaining mobility was better in those treated with a cemented implant (p = 0.005) at six months after operation. No statistically significant difference was found between the two groups with regard to mortality, implant-related complications, re-operations or post-operative medical complications.

The use of a cemented Thompson hemiarthroplasty resulted in less pain and less deterioration in mobility than an uncemented Austin-Moore prosthesis with no increase in complications.


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1538 - 1543
1 Nov 2013
Kendrick BJL Wilson HA Lippett JE McAndrew AR Andrade AJMD

The National Institute for Health and Clinical Excellence (NICE) guidelines from 2011 recommend the use of cemented hemi-arthroplasty for appropriate patients with an intracapsular hip fracture. In our institution all patients who were admitted with an intracapsular hip fracture and were suitable for a hemi-arthroplasty between April 2010 and July 2012 received an uncemented prosthesis according to our established departmental routine practice. A retrospective analysis of outcome was performed to establish whether the continued use of an uncemented stem was justified. Patient, surgical and outcome data were collected on the National Hip Fracture database. A total of 306 patients received a Cathcart modular head on a Corail uncemented stem as a hemi-arthroplasty. The mean age of the patients was 83.3 years (sd 7.56; 46.6 to 94) and 216 (70.6%) were women. The mortality rate at 30 days was 5.8%. A total of 46.5% of patients returned to their own home by 30 days, which increased to 73.2% by 120 days. The implant used as a hemi-arthroplasty for intracapsular hip fracture provided satisfactory results, with a good rate of return to pre-injury place of residence and an acceptable mortality rate. Surgery should be performed by those who are familiar with the design of the stem and understand what is required for successful implantation.

Cite this article: Bone Joint J 2013;95-B:1538–43.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 63 - 63
1 Feb 2012
Cumming D Parker M
Full Access

The two commonest types of hemiarthroplasty used for the treatment of a displaced intracapsular fracture are the uncemented Austin Moore Prosthesis and cemented Thompson hemiarthroplasty. To determine if any difference in outcome exists between these implants we undertook a prospective randomised controlled trial of 300 patients with a displaced intracapsular hip fractures.

All operations were performed or supervised by one orthopaedic surgeon and all by a standard anterolateral approach. Patients were followed by a nurse blinded in the type of prosthesis to assess residual pain and mobility.

The average age of the patients was 83 years and 23% were male. 73% came from their own home with the remainder from institutional care. There was no statistically significant difference in mortality between groups, with 34/151 having died at one year in the cemented group and 45/149 in the uncemented group. Pain scores (grade 1-6) were less for those treated by a cemented prosthesis (mean score 1.8 versus 2.4, p value <0.00001). Mobility change was also less for those treated with a cemented implant (p=0002). No difference was found in hospital stay. Operative complications are as listed. One case of non-fatal intraoperative cardiac arrest occurred in the cemented group.

In summary a cemented Thompson Hemiarthroplasty causes less pain and less deterioration in mobility compared to uncemented Austin Moore hemiarthroplasty, without any increase in complications. The continued use of an uncemented Austin Moore cannot be recommended.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 338 - 338
1 Mar 2004
Khan R MacDowell A Crossman P Datta A Jallali N Keene G
Full Access

Aim: To clarify the issue of whether or not to cement the hemiarthroplasty in the treatment of displaced intra-capsular femoral neck fractures in the elderly. Method: All patients with displaced intracapsular femoral neck fractures treated with hemiarthroplasty between January 1997 and May 1998, in 2 hospitals within the same Deanery, were reviewed. The same prosthesis was used; in hospital A they were uncemented, and in B cemented. There were 121 patients in hospital A and 123 in hospital B; all patients alive at follow-up (50 and 56 respectively) were interviewed for pre-fracture and current assessments of pain and functional ability using validated scoring systems. Follow-up was 32–36 months. Results: Patient demographics were similar. Cemented procedures took 15 minutes longer. In-patient stay was the same. Signiþcantly fewer of the cemented group had been revised or were awaiting revision (p=0.036). There was no difference in mortality rates at any point. Prospective assessment of surviving patients revealed highly statistically signiþcant greater deterioration in pain (p=0.003), walking ability (p=0.002), use of walking aids (p=0.003) and activities of daily living (p=0.009) in the uncemented group. The trend for more dependent accommodation in the uncemented group failed to reach statistical signiþcance (p=0.14). Conclusions: Our þndings support the use of cemented hemiarthroplasty for displaced intracapsular femoral neck fractures in the elderly.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 3 | Pages 409 - 412
1 May 1994
Christie J Burnett R Potts H Pell A

We performed transoesophageal echocardiography on 20 patients with femoral neck fractures randomly treated with an uncemented Austin-Moore or cemented Hastings hemiarthroplasty. Cemented arthroplasty caused greater and more prolonged embolic cascades than did uncemented arthroplasty. Some emboli were more than 3 cm in length. In some patients the cascades were associated with pulmonary hypertension, diminished oxygen tension and saturation, and the presence of fat and marrow in aspirates from the right atrium.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 254 - 254
1 May 2009
Haleem S Pryor GA Parker MJ
Full Access

Two of commonest types of hemiarthroplasty used for the treatment of a displaced intracapsular fracture are the uncemented Austin Moore Prosthesis and cemented Thompson hemiarthroplasty. We performed this trial to determine if any difference in outcome exist between these implants.

We undertook a prospective randomised controlled trial of four hundred patients with a displaced intra-capsular hip fracture. All operations were performed or supervised by one orthopaedic surgeon and all by a standard anterolateral approach. Patients were followed by a nurse blinded in the type of prosthesis to assess residual pain and mobility.

The average age of the patients was eighty-three years and 23% were male. 73% came from their own home with the remainder from institutional care. There was no statistically significant difference in mortality between groups. Pain scores were less for those treated by a cemented prosthesis (p value < 0.00001). Mobility change was also less for those treated with a cemented implant (p=0002). No difference was found in hospital stay, implant related complications, re-operations or post-operative medical complications between the two groups. One case of non-fatal intraoperative cardiac arrest occurred in the cemented group.

In summary a cemented Thompson Hemiarthroplasty causes less pain and less deterioration in mobility compared to the uncemented Austin Moore hemiarthroplasty, without any increase in complications. The continued use of an uncemented Austin Moore cannot be recommended.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 535 - 535
1 Aug 2008
Haleem S Pryor GA Parker MJ
Full Access

Introduction: Two of commonest types of hemiarthroplasty used for the treatment of a displaced intracapsular fracture are the uncemented Austin Moore Prosthesis and cemented Thompson hemiarthroplasty.

Methods: To determine if any difference in outcome exists between these implants, we undertook a prospective randomised controlled trial of 400 patients with a displaced intracapsular hip fracture. All operations were performed or supervised by one orthopaedic surgeon and all by a standard anterolateral approach. Patients were followed by a nurse blinded in the type of prosthesis to assess residual pain and mobility.

Results: The average age of the patients was 83 years and 23% were male. 73% came from their own home with the remainder from institutional care. There was no statistically significant difference in mortality between groups. Pain scores were less for those treated by a cemented prosthesis (p value < 0.00001). Mobility change was also less for those treated with a cemented implant (p=0002). No difference was found in hospital stay, implant related complications, re-operations or post-operative medical complications between the two groups. One case of non-fatal intraoperative cardiac arrest occurred in the cemented group.

Discussion: In summary a cemented Thompson Hemiarthroplasty causes less pain and less deterioration in mobility compared to the uncemented Austin Moore hemiarthroplasty, without any increase in complications. The continued use of an uncemented Austin Moore cannot be recommended.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 32 - 32
1 Sep 2012
McKenna S Kelly S Finlayson D
Full Access

Current evidence suggests that we should be moving away from Thompson's hemiarthroplasties for patients with intracapsular hip fractures. Furthermore, the use of cement when inserting these prostheses is controversial. This study aims to show the Inverness experience.

We performed a retrospective review of all NHS Highland patients who underwent a hemiarthroplasty for an intracapsular neck of femur fracture over the last 15 years. Demographics and the use of cement were documented. Further analysis of this group was performed to identify any of these patients who required revision of their prosthesis. Patients requiring revision had their case-notes reviewed to identify the cause for further surgery.

From 1996 until present 2221 patients from the Highland area had a hemiarthroplasty for an intracapsular neck of femur fracture. 1708 where female (77%) and 513 male (23%). The ages ranged from 28 years to 104 years (mean 80 years, median 81). 2180 of this group had their operations in Raigmore Hospital with the remaining 41 at various centres throughout Scotland. 623 (28%)had a cemented hemiarthroplasty, with the remaining 1578 (72%) having an uncemented Thompson's hemiarthroplasty. The revision rate for the cemented group was 2% (13 of 623 patients). In the uncemented group it was 0.4% (6 of 1578). Reasons from revision included dislocation, periprosthetic fracture, infection and pain.

Current evidence from some joint registers regarding the use of Thompson's hemiarthroplasty in the elderly is discouraging. The use of bone cement in this group with multiple co-morbidities is not without it's risks. Our data suggests that uncemented Thompson's hemiarthroplasties in low demand elderly patients with multiple co-morbidities can yield excellent results with less risk to the patients.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 80 - 80
1 Jan 2004
Reddy VRM Dorairajan A Krikler SJ
Full Access

Aims: To study clinical and radiological outcome of acetabular revision in THR with porous, hydroxyapatite-coated cups.

Methods: 50 acetabular revisions (48 patients) operated by single surgeon were reviewed. Uncemented, hydroxyapatite coated cup (Mallory/Head, Biomet) was used. Preoperative acetabular bone loss graded by Paprosky’s classification (grade 1: 12, grade 2a: 26, grade 2b: 8, 2c: 2, grade 3a: 2). Acetabulum alone was revised in 22 hips. Duration of follow up: 35 months (24–52). Clinical outcome assessment was done using Merle d’Aubigne and Postel score & QALY index questionnaire. Radiological assessment by standard X-rays taken at the latest review date. No case was lost to follow up.

Results: Merle d’Aubigne & Postel scores improved from 2.1, 2.7 and 2.4 (pre-operative) to 5.0, 4.3 and 4.5 (post-operative) respectively with significant improvement in QALYs scores. Radiological assessment showed no mechanical failures. Good trabecular formation between HA-coating and the bone seen in the majority. Non-progressive radiolucency < 1mm in 6 cases, superior migration > 2 mm in 3 cups where bone graft was used, and < 2mm migration in 9 cups was noted. 2 cases had rerevision for recurrent dislocation.

Conclusions: Hydroxyapatite coating on the implant may enhance bony ongrowth at bone-implant interface giving additional stability. Good midterm results obtained in our study using hydroxyapatite-coated components favour the use of this type of cup in acetabular revisions for moderate bone loss, but a long-term follow up is essential.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 57 - 57
1 Mar 2010
Chana* R Mansouri R Jack C Edwards M Singh R Khan F
Full Access

Introduction: The JRI Furlong HAC LOL hemiarthroplasty stem has shown increased periprosthetic fracture rates compared to previous literature(15.2% vs 7.4%). This study will seek to identify a measurable radiographic index, the Metaphyseal-Diaphyseal Index (MDI) score to determine whether intra-operative fracture in osteoporotic bone can be predicted to influence the type of prosthesis used (cemented or uncemented).

Methodology: Over 5 years prospectively, a cohort of 560 consecutive patients undergoing hemiarthroplasty (cemented and uncemented) were evaluated. Clinical outcomes and radiographic analysis was performed. The Vancouver Classification was used to classify peri-prosthetic fracture. The MDI score was calculated using radiographs from the uncemented group. As a control (gold standard), Yeung et al’s CBR score was also calculated. From this, a receiver operating characteristic (ROC) curve was formulated for both scores and area under the curve (AUC) compared. Intra and inter-observer correlations were determined. Cost analysis was also worked out for adverse outcomes.

Results: 407 uncemented and 153 cemented stems were implanted. 62 periprosthetic fractures occurred in the uncemented group (15.2%), 9 occurred in the cemented group (5.9%), p< 0.001. The revision rate for sustaining a periprosthetic fracture (uncemented group) was 17.7%, p< 0.001. MDI’s AUC was 0.985 compared to CBR’s 0.948, p< 0.001. The MDI score cut-off to predict fracture was 21, sensitivity 98.3%, specificity 99.8%, positive predictive value 90.5% and negative predictive value 98%. ANCOVA analysis ruled out any other confounding factors as being significant. The intra and inter-observer Pearson correlation scores were r=0.99, p< 0.001. The total extra cost due to the intra-operative fractures was ú40,140.

Discussion: The MDI score has been shown to be a potentially useful, cost effective way of preventing this serious complication from occurring. We recommend that any femur scoring 21 or less on the MDI score be considered for cemented hemiarthroplasty. Level of evidence: Level 2 Diagnostic Study: Investigating a diagnostic test against gold standard.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 609 - 609
1 Oct 2010
Chana R Edwards M Jack C Khan F Mansouri R Singh R
Full Access

Introduction: The JRI Furlong HAC LOL hemiarthroplasty stem has shown increased periprosthetic fracture rates compared to previous literature (15.2% vs 7.4%) [1,2,3]. This study seeks to identify a measurable radiographic index, the Metaphyseal-Diaphyseal Index (MDI) score to determine whether intra-operative fracture in osteoporotic bone can be predicted to influence the type of prosthesis used (cemented or uncemented).

Methodology: A 5 year prospective cohort of 560 consecutive patients underwent hemiarthroplasty (cemented or uncemented). A nested case-control study to determine risk factors affecting intra-operative fracture was carried out.

Clinical outcomes and radiographic analysis was performed. The Vancouver Classification was used to classify periprosthetic fracture.

The MDI score was calculated using radiographs, as a control (gold standard), Yeung’s CBR score was calculated [4]. See Figure 1. A receiver operating characteristic (ROC) curve was formulated for both and area under the curve (AUC) compared. Intra and inter-observer correlations were determined.

Cost analysis was also worked out.

Results: 407 uncemented and 153 cemented stems were implanted. The use of uncemented implants was the main risk factor for intra-operative periprosthetic fracture.

62 periprosthetic fractures occurred in the uncemented group (15.2%), 9 in the cemented group (5.9%), p< 0.001. The revision rate for sustaining a periprosthetic fracture (uncemented group) was 17.7%, p< 0.001 and 90 day mortality 19.7%, p< 0.03.

MDI’s AUC was 0.985 compared to CBR’s 0.948, p< 0.001. See Figure 2. The MDI score cut-off to predict fracture was 21, sensitivity 98.3%, specificity 99.8%, PPV 90.5%, NPV 98%. ANCOVA ruled out any other confounding factors as being significant.

The intra and inter-observer Pearson correlation scores were r=0.99, p< 0.001.

The total extra cost due to the intra-operative fractures was £93,780.

Discussion: The MDI score is a useful, cost effective way of preventing this serious complication from occurring. We recommend that any femur scoring 21 or less on the MDI score be considered for cemented hemiarthroplasty.

Level of evidence: Level 2 Diagnostic Study: Development of diagnostic criteria on basis of consecutive patients (with universally applied reference “gold” standard).


Bone & Joint Research
Vol. 12, Issue 5 | Pages 331 - 338
16 May 2023
Szymski D Walter N Krull P Melsheimer O Grimberg A Alt V Steinbrueck A Rupp M

Aims. The aim of this investigation was to compare risk of infection in both cemented and uncemented hemiarthroplasty (HA) as well as in total hip arthroplasty (THA) following femoral neck fracture. Methods. Data collection was performed using the German Arthroplasty Registry (EPRD). In HA and THA following femoral neck fracture, fixation method was divided into cemented and uncemented prostheses and paired according to age, sex, BMI, and the Elixhauser Comorbidity Index using Mahalanobis distance matching. Results. Overall in 13,612 cases of intracapsular femoral neck fracture, 9,110 (66.9%) HAs and 4,502 (33.1%) THAs were analyzed. Infection rate in HA was significantly reduced in cases with use of antibiotic-loaded cement compared with uncemented fixated prosthesis (p = 0.013). In patients with THA no statistical difference between cemented and uncemented prosthesis was registered, however after one year 2.4% of infections were detected in uncemented and 2.1% in cemented THA. In the subpopulation of HA after one year, 1.9% of infections were registered in cemented and 2.8% in uncemented HA. BMI (p = 0.001) and Elixhauser Comorbidity Index (p < 0.003) were identified as risk factors of periprosthetic joint infection (PJI), while in THA cemented prosthesis also demonstrated an increased risk within the first 30 days (hazard ratio (HR) = 2.73; p = 0.010). Conclusion. The rate of infection after intracapsular femoral neck fracture was statistically significantly reduced in patients treated by antibiotic-loaded cemented HA. Particularly for patients with multiple risk factors for the development of a PJI, the usage of antibiotic-loaded bone cement seems to be a reasonable procedure for prevention of infection. Cite this article: Bone Joint Res 2023;12(5):331–338


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 27 - 27
1 Dec 2022
Falsetto A Bohm E Wood G
Full Access

Recent registry data from around the world has strongly suggested that using cemented hip hemiarthroplasty has lower revision rates compared to cementless hip hemiarthroplasty for acute femoral neck hip fractures. The adoption of using cemented hemiarthroplasty for hip fracture has been slow as many surgeons continue to use uncemented stems. One of the reasons is that surgeons feel more comfortable with uncemented hemiarthroplasty as they have used it routinely. The purpose of this study is to compare the difference in revision rates of cemented and cementless hemiarthroplasty and stratify the risk by surgeon experience. By using a surgeons annual volume of Total Hip Replacements performed as an indicator for surgeon experience. The Canadian Joint Replacement Registry Database was used to collect and compare the outcomes to report on the revision rates based on surgeon volume. This is a large Canadian Registry Study where 68447 patients were identified for having a hip hemiarthroplasty from 2012-2020. This is a retrospective cohort study, identifying patients that had cementless or cemented hip hemiarthroplasty. The surgeons who performed the procedures were linked to the procedure Total Hip Replacement. Individuals were categorized as experienced hip surgeons or not based on whether they performed 50 hip replacements a year. Identifying high volume surgeon (>50 cases/year) and low volume (<50 cases/year) surgeons. Hazard ratios adjusted for age and sex were performed for risk of revision over this 8-year span. A p-value <0.05 was deemed significant. For high volume surgeons, cementless fixation had a higher revision risk than cemented fixation, HR 1.29 (1.05-1.56), p=0.017. This pattern was similar for low volume surgeons, with cementless fixation having a higher revision risk than cemented fixation, HR 1.37 (1.11-1.70) p=0.004 We could not detect a difference in revision risk for cemented fixation between low volume and high volume surgeons; at 0-1.5 years the HR was 0.96 (0.72-1.28) p=0.786, and at 1.5+ years the HR was 1.61 (0.83-3.11) p=0.159. Similarly, we could not detect a difference in revision risk for cementless fixation between low volume and high volume surgeons, HR 1.11 (0.96-1.29) p=0.161. Using large registry data, cemented hip hemiarthroplasty has a significant lower revision rate than the use of cementless stems even when surgeons are stratified to high and low volume. Low volume surgeons who use uncemented prostheses have the highest rate of revision. The low volume hip surgeon who cements has a lower revision rate than the high volume cementless surgeon. The results of this study should help to guide surgeons that no matter the level of experience, using a cemented hip hemiarthroplasty for acute femoral neck fracture is the safest option. That high volume surgeons who perform cementless hemiarthroplasty are not immune to having revisions due to their technique. Increased training and education should be offered to surgeons to improve comfort when using this technique


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 1 - 1
1 Dec 2022
Falsetto A Bohm E Wood G
Full Access

Recent registry data from around the world has strongly suggested that using cemented hip hemiarthroplasty has lower revision rates compared to cementless hip hemiarthroplasty for acute femoral neck hip fractures. The adoption of using cemented hemiarthroplasty for hip fracture has been slow as many surgeons continue to use uncemented stems. One of the reasons is that surgeons feel more comfortable with uncemented hemiarthroplasty as they have used it routinely. The purpose of this study is to compare the difference in revision rates of cemented and cementless hemiarthroplasty and stratify the risk by surgeon experience. By using a surgeons annual volume of Total Hip Replacements performed as an indicator for surgeon experience. The Canadian Joint Replacement Registry Database was used to collect and compare the outcomes to report on the revision rates based on surgeon volume. This is a large Canadian Registry Study where 68447 patients were identified for having a hip hemiarthroplasty from 2012-2020. This is a retrospective cohort study, identifying patients that had cementless or cemented hip hemiarthroplasty. The surgeons who performed the procedures were linked to the procedure Total Hip Replacement. Individuals were categorized as experienced hip surgeons or not based on whether they performed 50 hip replacements a year. Identifying high volume surgeon (>50 cases/year) and low volume (<50 cases/year) surgeons. Hazard ratios adjusted for age and sex were performed for risk of revision over this 8-year span. A p-value <0.05 was deemed significant. For high volume surgeons, cementless fixation had a higher revision risk than cemented fixation, HR 1.29 (1.05-1.56), p=0.017. This pattern was similar for low volume surgeons, with cementless fixation having a higher revision risk than cemented fixation, HR 1.37 (1.11-1.70) p=0.004 We could not detect a difference in revision risk for cemented fixation between low volume and high volume surgeons; at 0-1.5 years the HR was 0.96 (0.72-1.28) p=0.786, and at 1.5+ years the HR was 1.61 (0.83-3.11) p=0.159. Similarly, we could not detect a difference in revision risk for cementless fixation between low volume and high volume surgeons, HR 1.11 (0.96-1.29) p=0.161. Using large registry data, cemented hip hemiarthroplasty has a significant lower revision rate than the use of cementless stems even when surgeons are stratified to high and low volume. Low volume surgeons who use uncemented prostheses have the highest rate of revision. The low volume hip surgeon who cements has a lower revision rate than the high volume cementless surgeon. The results of this study should help to guide surgeons that no matter the level of experience, using a cemented hip hemiarthroplasty for acute femoral neck fracture is the safest option. That high volume surgeons who perform cementless hemiarthroplasty are not immune to having revisions due to their technique. Increased training and education should be offered to surgeons to improve comfort when using this technique


Bone & Joint 360
Vol. 11, Issue 6 | Pages 37 - 40
1 Dec 2022

The December 2022 Trauma Roundup. 360. looks at: Anterior approach for acetabular fractures using anatomical plates; Masquelet–Ilizarov for the management of bone loss post debridement of infected tibial nonunion; Total hip arthroplasty – better results after low-energy displaced femoral neck fracture in young patients; Unreamed intramedullary nailing versus external fixation for the treatment of open tibial shaft fractures in Uganda: a randomized clinical trial; The Open-Fracture Patient Evaluation Nationwide (OPEN) study: the management of open fracture care in the UK; Cost-utility analysis of cemented hemiarthroplasty versus hydroxyapatite-coated uncemented hemiarthroplasty; Unstable ankle fractures: fibular nail fixation compared to open reduction and internal fixation; Long-term outcomes of randomized clinical trials: wrist and calcaneus; ‘HeFT’y follow-up of the UK Heel Fracture Trial


Bone & Joint 360
Vol. 13, Issue 1 | Pages 13 - 16
1 Feb 2024

The February 2024 Hip & Pelvis Roundup. 360. looks at: Trial of vancomycin and cefazolin as surgical prophylaxis in arthroplasty; Is preoperative posterior femoral neck tilt a risk factor for fixation failure? Cemented versus uncemented hemiarthroplasty for displaced intracapsular fractures of the hip; Periprosthetic fractures in larger hydroxyapatite-coated stems: are collared stems a better alternative for total hip arthroplasty?; Postoperative periprosthetic fracture following hip arthroplasty with a polished taper slip versus composite beam stem; Is oral tranexamic acid as good as intravenous?; Stem design and the risk of early periprosthetic femur fractures following THA in elderly patients; Does powered femoral broaching compromise patient safety in total hip arthroplasty?


The Bone & Joint Journal
Vol. 96-B, Issue 9 | Pages 1185 - 1191
1 Sep 2014
Middleton RG Uzoigwe CE Young PS Smith R Gosal HS Holt G

We aimed to determine whether cemented hemiarthroplasty is associated with a higher post-operative mortality and rate of re-operation when compared with uncemented hemiarthroplasty. Data on 19 669 patients, who were treated with a hemiarthroplasty following a fracture of the hip in a nine-year period from 2002 to 2011, were extracted from NHS Scotland’s acute admission database (Scottish Morbidity Record, SMR01). We investigated the rate of mortality at day 0, 1, 7, 30, 120 and one-year post-operatively using 12 case-mix variables to determine the independent effect of the method of fixation. At day 0, those with a cemented hemiarthroplasty had a higher rate of mortality (p < 0.001) compared with those with an uncemented hemiarthroplasty, equivalent to one extra death per 424 procedures. By day one this had become one extra death per 338 procedures. Increasing age and the five-year co-morbidity score were noted as independent risk factors. By day seven, the cumulative rate of mortality was less for cemented hemiarthroplasty though this did not reach significance until day 120. The rate of re-operation was significantly higher for uncemented hemiarthroplasty. Despite adjusting for 12 confounding variables, these only accounted for 15% of the observed variability. The debate about the choice of the method of fixation for a hemiarthroplasty with respect to the rate of mortality or the risk of re-operation may be largely superfluous. Our results suggest that uncemented hemiarthroplasties may have a role to play in elderly patients with significant co-morbid disease. Cite this article: Bone Joint J 2014;96-B:1185–91


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 5 - 5
24 Nov 2023
Szymski D Walter N Krull P Melsheimer O Grimberg A Alt V Steinbrück A Rupp M
Full Access

Aim. The aim of this investigation was to compare risk of infection in both cemented and cementless hemiarthroplasty (HA) as well as total hip arthroplasty (THA) following femoral neck fracture. Methods. Data collection was performed using the German Arthroplasty Registry (EPRD) In HA and THA following femoral neck fracture fixation method was divided into cemented and cementless protheses and paired according to age, sex, body mass index (BMI), and the Elixhauser score using Mahalanobis distance matching. Results. Overall in 13,612 cases of intracapsular femoral neck fracture, with 9,110 (66.9 %) HAs and 4502 (33.1 %) THAs were analyzed. Infection rate in HA was significantly reduced in cases with use of antibiotic-loaded cement compared to cementless fixated prosthesis (p=0.013). In patients with THA no statistical difference between cemented and cementless prothesis was registered, however after one year 2.4 % of infections were detected in cementless and 2.1 % in cemented THA. In the subpopulation of HA after one year 1.9 % of infections were registered in cemented and 2.8 % in cementless HA. BMI (p=0.001) and Elixhauser-Comorbidity-Score (p<0.003) were identified as risk factors of PJI, while in THA also cemented prosthesis demonstrated within the first 30 days an increased risk (HR=2.728; p=0.010). Conclusion. The rate of infection after intracapsular femoral neck fracture was significantly reduced in patients treated by antibiotic-loaded cemented hemiarthroplasty. In particular for patients with multiple risk factors for the development of a PJI the usage of antibiotic-loaded bone cement seems to be a reasonable procedure for prevention of infection


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 16 - 16
1 Dec 2022
Ibrahim M Abdelbary H Mah T
Full Access

Gram-negative prosthetic joint infections (GN-PJI) present unique challenges in management due to their distinct pathogenesis of biofilm formation on implant surfaces. To date, there are no animal models that can fully recapitulate how a biofilm is challenged in vivo in the setting of GN-PJI. The purpose of this study is to establish a clinically representative GN-PJI in vivo model that can reliably depict biofilm formation on titanium implant surface. We hypothesized that the biofilm formation on the implant surface would affect the ability of the implant to be osseointegrated. The model was developed using a 3D-printed, medical-grade titanium (Ti-6Al-4V), monoblock, cementless hemiarthroplasty hip implant. This implant was used to replace the femoral head of a Sprague-Dawley rat using a posterior surgical approach. To induce PJI, two bioluminescent Pseudomonas aeruginosa (PA) strains were utilized: a reference strain (PA14-lux) and a mutant strain that is defective in biofilm formation (DflgK-lux). PJI development and biofilm formation was quantitatively assessed in vivo using the in vivo imaging system (IVIS), and in vitro using the viable colony count of the bacterial load on implant surface. Magnetic Resonance Imaging (MRI) was acquired to assess the involvement of periprosthetic tissue in vivo, and the field emission scanning electron microscopy (FE-SEM) of the explanted implants was used to visualize the biofilm formation at the bone-implant interface. The implant stability, as an outcome, was directly assessed by quantifying the osseointegration using microCT scans of the extracted femurs with retained implants in vitro, and indirectly assessed by identifying the gait pattern changes using DigiGaitTM system in vivo. A localized prosthetic infection was reliably established within the hip joint and was followed by IVIS in real-time. There was a quantitative and qualitative difference in the bacterial load and biofilm formation between PA14 and DflgK. This difference in the ability to persist in the model between the two strains was reflected on the gait pattern and implant osseointegration. We developed a novel uncemented hip hemiarthroplasty GN-PJI rat model. This model is clinically representative since animals can bear weight on the implant. PJI was detected by various modalities. In addition, biofilm formation correlated with implant function and stability. In conclusion, the proposed in vivo GN-PJI model will allow for more reliable testing of novel biofilm-targeting therapetics


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1113 - 1119
1 Aug 2012
Gjertsen J Lie SA Vinje T Engesæter LB Hallan G Matre K Furnes O

Using data from the Norwegian Hip Fracture Register, 8639 cemented and 2477 uncemented primary hemiarthroplasties for displaced fractures of the femoral neck in patients aged > 70 years were included in a prospective observational study. A total of 218 re-operations were performed after cemented and 128 after uncemented procedures. Survival of the hemiarthroplasties was calculated using the Kaplan-Meier method and hazard rate ratios (HRR) for revision were calculated using Cox regression analyses. At five years the implant survival was 97% (95% confidence interval (CI) 97 to 97) for cemented and 91% (95% CI 87 to 94) for uncemented hemiarthroplasties. Uncemented hemiarthroplasties had a 2.1 times increased risk of revision compared with cemented prostheses (95% confidence interval 1.7 to 2.6, p < 0.001). The increased risk was mainly caused by revisions for peri-prosthetic fracture (HRR = 17), aseptic loosening (HRR = 17), haematoma formation (HRR = 5.3), superficial infection (HRR = 4.6) and dislocation (HRR = 1.8). More intra-operative complications, including intra-operative death, were reported for the cemented hemiarthroplasties. However, in a time-dependent analysis, the HRR for re-operation in both groups increased as follow-up increased. This study showed that the risk for revision was higher for uncemented than for cemented hemiarthroplasties


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 64 - 64
1 Aug 2013
Middleton RG Uzoigwe CE Young PS Smith R Gosal HS Holt G
Full Access

The surgical treatment options for patients who have sustained an intra-capsular hip fracture can vary depending on a number of patient and fracture related factors. Currently most national guidelines support the use of cemented prostheses for patient undergoing hemiarthroplasty surgery. Uncemented prostheses are commonly used for a variety of indications including those patients who have significant medical co-morbidities. To determine whether cemented hemiarthroplasty is associated with a higher post operative mortality when compared to uncemented procedures. Data were extracted from the Scottish SMR01 database from 01/04/1997 from all patients who were admitted to hospital after sustaining a hip fracture. We investigated mortality at day 1,2,4,7,30, 120 and 1 year from surgery vs. that on day 0. In order to control for the effects of confounding variables between patients cohorts, 12 case-mix variable were used to construct a multivariable logistic regression analysis model to determine the independent effect of prosthesis design. There were 52283 patients included in the study. Mortality for osteosynthesis of extra-capsular fractures was consistently lower when compared to that for surgical procedures for intra-capsular fractures. At day 0, uncemented hemiarthroplasty had a lower associated mortality (p<0.001) when compared to cemented implant designs. However, this increased mortality was equal to 1 extra death per 2000 procedures. From day 1 onward mortality for cemented procedures was equal to or lower than that of uncemented. By day 4, cumulative mortality was less for cemented than for uncemented procedures. Complication and re-operation rate was significantly higher in the uncemented cohort. The use of uncemented hemiarthroplasty for the treatment of intra-capsular hip fractures cannot be justified in terms of early/late post-operative mortality


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 30 - 30
1 Sep 2012
Al-Atassi T Chou D Boulton C Moran C
Full Access

Introduction. Cemented hemiarthroplasty for neck of femur fractures has been advocated over uncemented hemiarthroplasty due to better post-operative recovery and patient satisfaction. However, studies have shown adverse effects of bone cement on the cardio-respiratory system which may lead to higher morbidity and mortality. Therefore, in some institutes, the use of an uncemented prosthesis has been adopted for patients with a high number of co-morbidities. The aim was to compare early mortality rates for cemented vs. uncemented hemiarthroplasties. Method. Cohort study of displaced intracapsular hip fractures treated with hemiarthroplasty between 1999–2009 at one institute. A total of 3094 hemiarthroplasties performed; out of which 1002(32.4%) were cemented and 2092(67.6%) were uncemented. 48hour and 30day mortality rates for the two groups were compared and a multivariate Cox regression model used to eliminate confounding factors. Significant confounding factor included age, sex, mini mental test score, medical co-morbidities, Nottingham Hip Fracture Score and delay to surgery. Results. The study showed that, after eliminating confounding factors, 48hour mortality in the cemented group was 0.3% compared to 0.5% in the uncemented group (p=0.388). However, the adjusted 30day mortality rate for the cemented group (4%) was shown to be significantly lower than for the uncemented group (10.8%) (p< 0.001). Conclusion. The use of cement in hip hemiarthroplasty is not associated with an increased rate of mortality at 48hours or at 30days. Along with emerging evidence of better post-op recovery and patient satisfaction with the use of a cemented prosthesis, we support the use of cement for all patients undergoing hip hemiarthroplasty


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_31 | Pages 37 - 37
1 Aug 2013
Leitch A Joseph J Murray H McMillan T Meek R
Full Access

Over 70,000 hip fractures occur annually in the UK. Both SIGN (111) and NICE (124) give guidance on optimal management of these patients. Both suggest cemented hemiarthroplasty should be used in those without contra-indications, as cemented implants are associated with less thigh pain, subsidence and a better functional outcome. Cardiorespiratory compromise secondary to bone cement implantation syndrome (BCIS) is however a concern in those with pre-existing cardiorespiratory disease (NYHA grade 3–4, pulmonary hypertension) or pathological fracture [3]. The aim of our study was to audit the practice of a University of Glasgow hospital with regard to cemented hemiarthroplasty. We retrospectively reviewed data on all patients treated with hemiarthroplasty for hip fracture at the Southern General Hospital between 01/01/12-02/04/12. Patient demographics, pre-operative plan, procedure performed, ASA grade and pre-morbid mobility were recorded. Results. Twenty-three hemiarthroplasties were performed. The median age was 82 (70–101). No patient aged over 90 underwent cemented hemiarthroplasty. Cemented implants (JRI, Furlong) were used in 26% (n=6) while 74% (n=17) underwent uncemented (Stryker, Austin-Moore) hemiarthroplasty. ASA grade was recorded in eight (35%). There were four ASA-2 patients (mild systemic disease not limiting activity) of which 75% underwent uncemented hemiarthroplasty. Pre-morbid mobility was recorded in eight (35%). All three independently mobile patients underwent uncemented hemiarthroplasty. Six (26%) had a documented pre-operative plan with regards to cement use. This study highlights the disparity between current recommendations and our Centres’ practice. Most notable were: poor recording of pre-operative mobility, poor documentation of a pre-operative surgical plan, the low use of cemented fixation even in fit mobile patients and the lack of ASA grade recording (stratification of risk) by our anaesthetic colleagues. We suggest a documented pre-operative discussion between the surgeon and anaesthetist to establish BCIS risk and decide on use of cemented arthroplasty taking into account age and mobility


Bone & Joint 360
Vol. 11, Issue 4 | Pages 32 - 35
1 Aug 2022


Bone & Joint 360
Vol. 12, Issue 4 | Pages 13 - 16
1 Aug 2023

The August 2023 Hip & Pelvis Roundup360 looks at: Using machine learning to predict venous thromboembolism and major bleeding events following total joint arthroplasty; Antibiotic length in revision total hip arthroplasty; Preoperative colonization and worse outcomes; Short stem cemented total hip arthroplasty; What are the outcomes of one- versus two-stage revisions in the UK?; To cement or not to cement? The best approach in hemiarthroplasty; Similar re-revisions in cemented and cementless femoral revisions for periprosthetic femoral fractures in total hip arthroplasty; Are hip precautions still needed?


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_8 | Pages 3 - 3
1 Jun 2015
Beech Z Kiziridis G Collins J Sweeney A Higgs D
Full Access

A retrospective review was conducted of patients undergoing either total hip replacement or hemiarthroplasty for intra-capsular neck of femur fractures between April 2013 and April 2014; identified from entries into the National Hip Fracture Database. PACS and the electronic database encompassing operation notes and discharge summaries were reviewed. 309 patients were identified, 3 of whom fractured both hips during the study period giving a total of 312 operations. The age range was 46 to 102 with a mean age of 82. 59 cemented bipolar hemiarthroplasties, 143 cemented unipolar hemiarthroplasties, 2 uncemented hemiarthroplasties and 108 total hip replacements were performed. 10 patients required further operations. There have been 5 dislocations: 2 underwent MUA only, 2 treated by excision arthroplasty and 1 converted to THR. 1 patient developed a haematoma requiring wound washout. There were 4 wound infections - 1 treated by a washout, 2 by excision arthroplasty and one patient has undergone first stage revision; an overall reoperation rate of 3.2% comparing well with data published elsewhere


The Bone & Joint Journal
Vol. 104-B, Issue 10 | Pages 1190 - 1190
1 Oct 2022
Png ME Petrou S Fernandez MA Achten J Parsons N McGibbon A Gould J Griffin XL Costa ML


The Bone & Joint Journal
Vol. 106-B, Issue 4 | Pages 319 - 322
1 Apr 2024
Parsons N Whitehouse MR Costa ML


The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 864 - 871
1 Aug 2023
Tyas B Marsh M de Steiger R Lorimer M Petheram TG Inman DS Reed MR Jameson SS

Aims

Several different designs of hemiarthroplasty are used to treat intracapsular fractures of the proximal femur, with large variations in costs. No clinical benefit of modular over monoblock designs has been reported in the literature. Long-term data are lacking. The aim of this study was to report the ten-year implant survival of commonly used designs of hemiarthroplasty.

Methods

Patients recorded by the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) between 1 September 1999 and 31 December 2020 who underwent hemiarthroplasty for the treatment of a hip fracture with the following implants were included: a cemented monoblock Exeter Trauma Stem (ETS), cemented Exeter V40 with a bipolar head, a monoblock Thompsons prosthesis (Cobalt/Chromium or Titanium), and an Exeter V40 with a Unitrax head. Overall and age-defined cumulative revision rates were compared over the ten years following surgery.


Bone & Joint Open
Vol. 3, Issue 9 | Pages 710 - 715
5 Sep 2022
Khan SK Tyas B Shenfine A Jameson SS Inman DS Muller SD Reed MR

Aims

Despite multiple trials and case series on hip hemiarthroplasty designs, guidance is still lacking on which implant to use. One particularly deficient area is long-term outcomes. We present over 1,000 consecutive cemented Thompson’s hemiarthroplasties over a ten-year period, recording all accessible patient and implant outcomes.

Methods

Patient identifiers for a consecutive cohort treated between 1 January 2003 and 31 December 2011 were linked to radiographs, surgical notes, clinic letters, and mortality data from a national dataset. This allowed charting of their postoperative course, complications, readmissions, returns to theatre, revisions, and deaths. We also identified all postoperative attendances at the Emergency and Outpatient Departments, and recorded any subsequent skeletal injuries.


Bone & Joint Open
Vol. 4, Issue 3 | Pages 198 - 204
16 Mar 2023
Ramsay N Close JCT Harris IA Harvey LA

Aims

Cementing in arthroplasty for hip fracture is associated with improved postoperative function, but may have an increased risk of early mortality compared to uncemented fixation. Quantifying this mortality risk is important in providing safe patient care. This study investigated the association between cement use in arthroplasty and mortality at 30 days and one year in patients aged 50 years and over with hip fracture.

Methods

This retrospective cohort study used linked data from the Australian Hip Fracture Registry and the National Death Index. Descriptive analysis and Kaplan-Meier survival curves tested the unadjusted association of mortality between cemented and uncemented procedures. Multilevel logistic regression, adjusted for covariates, tested the association between cement use and 30-day mortality following arthroplasty. Given the known institutional variation in preference for cemented fixation, an instrumental variable analysis was also performed to minimize the effect of unknown confounders. Adjusted Cox modelling analyzed the association between cement use and mortality at 30 days and one year following surgery.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 100 - 100
1 Jan 2016
Kenmoku T Miyajima G Higashiyama R Takahira N Takaso M
Full Access

Introduction. Proximal humeral fracture occurs most frequently in elderly and usually unite within 12 weeks. Malunion is more common than nonunion. And even if nonunion occurs, we usually treat it by the blade plate. Norris et al. reported hemiarthroplasty is indicated for severe degenerative changes of the articular surface, osteonecrosis of the humeral head, or osteopenia severe enough to jeopardize fixation in order patients. Therefore, it is not common that hemiarthroplasty is used for primary treatment of the proximal humeral pseudoarthrosis. We report a case of proximal humerus pseudoarthrosis which was treated by hemiarthroplasty. Case. A patients is 75 years old male. He was injured by falling from ladder. He was diagnosed proximal humeral fracture Neer type2. After he was followed conservatively for one year, he was referred to our hospital. In X-ray film and CT, the humeral head was scraped by the humeral shaft that was tucked inward to humeral head.(Figure 1) In MRI, rotator cuff muscles were left. The fatty infiltration was stage 1 in the Gourtallier classification. (Figure 2)And osteoarthritis of shoulder was not so severe. Therefore, we decided to do hemiarthroplasty. We used the SMR implant (Lima Corporate, Milano, Italy). Surgical reconstruction was done using a deltpectral approach. Lesser tuberosity was cut from greater tuberosity with subscaplaris muscle. We used the cementless stem. Each fragments and stem was fixed using FiberWire (Arthrex, Florida USA), after autograft which scraped from the reseceted humeral head was stuffed. After the operation, the shoulder was fixed by brace for 4weeks. The passive ROM exercise was started from 21 days later. The Active ROM exercise was started at 28 days later. Three months later, the pseudoarthrosis united successfully. (Figure 3) The active flexion was improved from 20 degrees to 110 degrees. The active abduction was from 20 degrees to 90 degrees. USLA score was improved from 10 to 26. Discussion. In this case, the pseudoarthrosis is united successfully. Therefore, the cementless hemiarthroplasty is useful for treatment for the proximal humerus pseudoarthrosis with severe humeral head bone defect


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1070 - 1077
1 Oct 2023
Png ME Costa M Nickil A Achten J Peckham N Reed MR

Aims

To compare the cost-effectiveness of high-dose, dual-antibiotic cement versus single-antibiotic cement for the treatment of displaced intracapsular hip fractures in older adults.

Methods

Using data from a multicentre randomized controlled trial (World Hip Trauma Evaluation 8 (WHiTE-8)) in the UK, a within-trial economic evaluation was conducted. Resource usage was measured over 120 days post randomization, and cost-effectiveness was reported in terms of incremental cost per quality-adjusted life year (QALY), gained from the UK NHS and personal social services (PSS) perspective in the base-case analysis. Methodological uncertainty was addressed using sensitivity analysis, while decision uncertainty was handled using confidence ellipses and cost-effectiveness acceptability curves.


Aims

The aims of this study were to evaluate the incidence of reoperation (all cause and specifically for periprosthetic femoral fracture (PFF)) and mortality, and associated risk factors, following a hemiarthroplasty incorporating a cemented collarless polished taper slip stem (PTS) for management of an intracapsular hip fracture.

Methods

This retrospective study included hip fracture patients aged 50 years and older treated with Exeter (PTS) bipolar hemiarthroplasty between 2019 and 2022. Patient demographics, place of domicile, fracture type, delirium status, American Society of Anesthesiologists (ASA) grade, length of stay, and mortality were collected. Reoperation and mortality were recorded up to a median follow-up of 29.5 months (interquartile range 12 to 51.4). Cox regression was performed to evaluate independent risk factors associated with reoperation and mortality.


The Bone & Joint Journal
Vol. 106-B, Issue 6 | Pages 603 - 612
1 Jun 2024
Ahmad A Egeland EH Dybvik EH Gjertsen J Lie SA Fenstad AM Matre K Furnes O

Aims

This study aimed to compare mortality in trochanteric AO/OTA A1 and A2 fractures treated with an intramedullary nail (IMN) or sliding hip screw (SHS). The primary endpoint was 30-day mortality, with secondary endpoints at 0 to 1, 2 to 7, 8 to 30, 90, and 365 days.

Methods

We analyzed data from 26,393 patients with trochanteric AO/OTA A1 and A2 fractures treated with IMNs (n = 9,095) or SHSs (n = 17,298) in the Norwegian Hip Fracture Register (January 2008 to December 2020). Exclusions were made for patients aged < 60 years, pathological fractures, pre-2008 operations, contralateral hip fractures, fractures other than trochanteric A1/A2, and treatments other than IMNs or SHSs. Kaplan-Meier and Cox regression analyses adjusted for type of fracture, age, sex, cognitive impairment, American Society of Anesthesiologists (ASA) grade, and time period were conducted, along with calculations for number needed to harm (NNH).


Bone & Joint 360
Vol. 11, Issue 3 | Pages 46 - 47
1 Jun 2022
Das A


Bone & Joint Open
Vol. 3, Issue 8 | Pages 611 - 617
1 Aug 2022
Frihagen F Comeau-Gauthier M Axelrod D Bzovsky S Poolman R Heels-Ansdell D Bhandari M Sprague S Schemitsch E

Aims

The aim of this study was to explore the functional results in a fitter subgroup of participants in the Hip Fracture Evaluation with Alternatives of Total Hip Arthroplasty versus Hemiarthroplasty (HEALTH) trial to determine whether there was an advantage of total hip arthroplasty (THA) versus hemiarthroplasty (HA) in this population.

Methods

We performed a post hoc exploratory analysis of a fitter cohort of patients from the HEALTH trial. Participants were aged over 50 years and had sustained a low-energy displaced femoral neck fracture (FNF). The fittest participant cohort was defined as participants aged 70 years or younger, classified as American Society of Anesthesiologists grade I or II, independent walkers prior to fracture, and living at home prior to fracture. Multilevel models were used to estimate the effect of THA versus HA on functional outcomes. In addition, a sensitivity analysis of the definition of the fittest participant cohort was performed.


Bone & Joint 360
Vol. 11, Issue 3 | Pages 14 - 17
1 Jun 2022


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_30 | Pages 38 - 38
1 Aug 2013
Baird E Spence S Ayana G
Full Access

Displaced fractures of the neck of femur are routinely treated in the elderly by either cemented hemiarthoplasty, in the fit, or uncemented hemiarthroplasty, in the less fit. In Scotland the Scottish Intercollegiate Guidelines Network (SIGN) guidelines are followed to identify which patients should have a cemented prosthesis. This is based on cardiovascular status, and the age and fragility of the patient. An uncemented prosthesis should be a final operation. A peri-prosthetic fracture is considered a failure of treatment as the patient then has to undergo an operation with a far greater surgical insult. We looked at all neck of femur fractures over a period of Jan 2007 to June 2010. The number of the peri-prosthetic fractures for uncemented hip hemiarthroplasties was established, and a case note review was carried out. There was 1397 neck of femur fractures. 546 hemiarthroplasties were carried out, of which 183 were cemented, and 363 uncemented. 15 patients (4% of uncemented hemiarthoplasties) had peri-prosthetic fractures. There were no peri-prosthetic fractures in the cemented group, p = 0.004 using Fisher's exact test. The case notes of these patients were analysed. We found there was a common link of significant cardiovascular risk, lack of falls assessment (only 14% of the patients had a completed falls assessment and 21% sustained their fracture during an admission to hospital) and confusion (50% had a degree of dementia that caused significant confusion). Cemented implants should be considered in all patients, especially those who are cognitively impaired or have failed falls assessments; even if the cardiovascular risk is significant. This decision should be made in conjunction with a senior anaesthetist. This is being implemented in our unit and a prospective audit is being carried out over the same time period (July 2010 to Dec 2013) to assess the benefit


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVIII | Pages 41 - 41
1 Jun 2012
Baird E Spence S Ayana G
Full Access

Displaced fractures of the neck of femur are routinely treated in the elderly by either cemented hemiarthoplasty, in the fit, or uncemented hemiarthroplasty, in the less fit. In Scotland the Scottish Intercollegiate Guidelines Network (SIGN) guidelines are followed to identify which patients should have a cemented prosthesis. This is based on cardiovascular status, and the age and fragility of the patient. An uncemeted prosthesis should be a final operation. A peri-prosthetic fracture is considered a failure of treatment as the patient then has to undergo an operation with a far greater surgical insult. We looked at all neck of femur fractures over a period of Jan 2007 to June 2010. The number of the peri-prosthetic fractures for uncemented hip hemiarthroplasties was established and a case note review carried out. There were 397 neck of femur fractures. 546 hemiarthroplasties were carried out, of which 183 were cemented, and 363 uncemented. 14 patients (4% of uncemented arthoplasties) had peri-prosthetic fractures. The case notes of these patients were analysed. There was a common link of significant cardiovascular risk, lack of falls assessment, and confusion. Cemented implants should be considered in those who have failed falls assessment, or are confused; even if the cardiovascular risk is significant. This decision should be made in conjunction with a senior anaethetist. This is being implemented in our unit and a prospective audit is being carried out over the same time period (July 2010 to Dec 2013) to assess the benefit


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIV | Pages 18 - 18
1 Jul 2012
Baird E Spence S Ayana G
Full Access

Displaced fractures of the neck of femur are routinely treated in the elderly by either cemented hemiarthoplasty, in the fit, or uncemented hemiarthroplasty, in the less fit. In Scotland the Scottish Intercollegiate Guidelines Network (SIGN) guidelines are followed to identify which patients should have a cemented prosthesis. This is based on cardiovascular status, and the age and fragility of the patient. An uncemented prosthesis should be a final operation. A peri-prosthetic fracture is considered a failure of treatment as the patient then has to undergo an operation with a far greater surgical insult. We looked at all neck of femur fractures over a period of Jan 2007 to June 2010. The number of the peri-prosthetic fractures for uncemented hip hemiarthroplasties was established and a case note review was carried out. There was 1397 neck of femur fractures. 546 hemiarthroplasties were carried out, of which 183 were cemented, and 363 uncemented. 14 patients (4% of uncemented hemiarthoplasties) had peri-prosthetic fractures. The case notes of these patients were analysed. We found there was a common link of significant cardiovascular risk, lack of falls assessment (only 14% of patients had a completed falls assessment and 35% sustained their fracture during an admission to hospital) and confusion (43% had a degree of dementia that caused significant confusion). Cemented implants should be considered in those who have failed falls assessment, or are confused; even if the cardiovascular risk is significant. This decision should be made in conjunction with a senior anaesthetist. This is being implemented in our unit and a prospective audit is being carried out over the same time period (July 2010 to Dec 2013) to assess the benefit


The Journal of Bone & Joint Surgery British Volume
Vol. 73-B, Issue 6 | Pages 902 - 907
1 Nov 1991
Llinas A Sarmiento A Ebramzadeh E Gogan W McKellop H

We compared the radiographic results of secondary total hip replacements, 99 following failed uncemented hemiarthroplasties and 21 following failed mould arthroplasties, with those of 825 primary cemented total hip replacements. The probability of occurrence of a number of radiological changes over time was calculated using survival analysis. The mean follow-up was 7.6 years (range one month to 20 years). The performance of the secondary total hip replacements varied with the preceding implant and was different for acetabular and femoral components. The incidence of radiological loosening was higher for femoral components implanted after failed hemiarthroplasties and for acetabular components after failed mould arthroplasties. However, the incidence of continuous radiolucent lines was lower for the acetabular components of converted hemiarthroplasties than for the primary replacements


Bone & Joint Open
Vol. 2, Issue 11 | Pages 958 - 965
16 Nov 2021
Craxford S Marson BA Nightingale J Ikram A Agrawal Y Deakin D Ollivere B

Aims

Deep surgical site infection (SSI) remains an unsolved problem after hip fracture. Debridement, antibiotic, and implant retention (DAIR) has become a mainstream treatment in elective periprosthetic joint infection; however, evidence for DAIR after infected hip hemiarthroplaty is limited.

Methods

Patients who underwent a hemiarthroplasty between March 2007 and August 2018 were reviewed. Multivariable binary logistic regression was performed to identify and adjust for risk factors for SSI, and to identify factors predicting a successful DAIR at one year.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 68 - 68
1 Sep 2012
Davidson J Chana R Miles K East D Apthorp H Butler-Manuel P
Full Access

Introduction. The Oxford Total Meniscal Knee (TMK by Biomet), is a total knee replacement with a multidirectional mobile bearing. As part of the evaluation of the TMK we compared our group of TMK knee replacements with an equivalent cohort of AGC total knee replacements. Methods. Patients recruited to AGC trial from 1994 to 2001. 254 AGC knee replacements sequentially recruited in 210 patients. Patients recruited to TMK trial from 2001 to 2007. 221 TMK knee replacements sequentially recruited in 193 patients. Patients prospectively randomised to having uncemented HA coated (HAC) or cemented versions in both groups. Each patient was reviewed pre-operatively, at 6 weeks, 6 months, 1 year and then annually. All AGC & TMK TKR's were assessed clinically using HSS scores and radiographically. TMK group also assessed using AKSS and OKQ scores. Results. AGC; 254 TKR (118 cemented, 136 HAC) Mean Age 67.5 (47–75yrs). Follow up 7–14 years (Mean 9.2yrs). 4 revisions TMK; 221 TKR (106 cemented, 115 HAC) Mean Age 67 (47–75yrs). Follow up 4–10 years (Mean 6.2 yrs). 8 revisions and 2 bearing exchanges. 4 revisions were for aseptic loosening, 1 for unexplained pain, 1 for bearing fracture and 2 for infection. 6 revisions in HAC group. No significant differences in functional outcome scores between cemented and HAC in TMK or AGC groups. HSS scores in the TMK group were lower than in the AGC group (82 vs 85, p = 0.007 2 tailed unequal variance t test). Discussion. The TMK appears to have a higher revision rate that the AGC with shorter follow-up. This particularly affects the HAC group. Although Functional outcome scores for the TMK are good they are still lower than the AGC. We aim to continue to follow up the TMK knee replacement to assess its survival


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 168 - 169
1 Mar 2006
Hussain S Hawkins A Smith R
Full Access

We have performed a prospective review of 590 consecutive patients treated for a displaced intracapsular femoral neck fracture with a Thompson hemiarthroplasty. 113 patients had the prosthesis cemented, 477 had no cement. The outcome at 12 months was obtained for every patient still alive as regards to pain, mobility, re-operation rate and residential status. There was no significant difference between the 2 groups as regards pain (p = 0.482), decrease in mobility or re-operation rate (p = 0.168). The main determination of poor outcome was increasing age at time of injury and whether the patient was already in institutional care at the time of the injury. The use of cement had no bearing on outcome. This study is of clinical interest because patients who have undergone uncemented hemiarthroplasty have been shown to have similar out come to cemented hemiarthroplasty in terms of function. In addition possible but preventable complications associated with cementing can be minimized. We now believe there is no primary indication to cement the Thompsons hemiarthroplasty in this group of patients. There have been smaller studies looking at this, but we believe this to be the largest and most comprehensive to date


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 407 - 407
1 Sep 2009
Fern E Williams D Reddy R Norton M
Full Access

Thinning of the femoral neck occurs in 77% of patients undergoing hybrid Birmingham hip resurfacing using a posterior approach (Shimmin 2007). Villar recently reported lower neck thinning rates in uncemented Cormet resurfacings (11.7%) compared with hybrid Birmingham resurfacing (13.4%), both via a posterior approach. We have evaluated implant position and femoral neck thinning in a cohort of 273 uncemented HA coated Cormet 2000 hip resurfacings using ‘B’-series (Titanium/HA coated) cups in 269 patients (mean age 54 years, 39% female) with a mean follow-up of 3 years (range 1–4 years). Mean cup inclination was 45° (30°–63°), mean SSA 138° (120°–178°). No lucent or sclerotic zones have been identified around the stem of the component. Only one femoral neck fracture has occurred (incidence 0.36%). We have identified only one case of femoral neck thinning in our series (0.36%). Whilst Villar has demonstrated a slight reduction in neck thinning rates using the same implants compared to a hybrid fixation Birmingham resurfacing, his neck thinning rates are almost 40 times higher than in our series. Shimmins ‘severe neck thinning (> 10%) rates (27%) are approximately 120 times higher than our series. In addition, we have been unable to confirm the relationship between implant position and neck thinning described by Shimmin in our series using the combined Ganz/uncemented resurfacings compared with Birmingham resurfacings. Implant design and surgical approach have an impact on ‘neck thinning after resurfacing; we should be wary of treating all resurfacing implants and techniques as a uniform cohort


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 206 - 206
1 Mar 2004
Jalovaara P Partanen J Heikkinen T Wingstrand H Thorngren K
Full Access

Aims: To find out if osteosynthesis (OS) or hemiarthroplasty (HA) is better in terms of functional outcome. Patients and methods: In 1989–1996, all displaced cervical hip fractures were prospectively, using the same forms, registered at the University Hospitals of Oulu in Finland and Lund in Sweden. Cross-matchings was performed for age, sex, preoperative residence, and ambulatory capacity. Results: The first study comprised 357 pairs (OS with two hook pins and cementless Austin-Moore HA): OS was associated with a better functional outcome and lower mortality, but a higher re-operation rate than hemiarthroplasty. The second study had 446 pairs (OS two hook pins and cemntless HA): OS was associated with better function and lower mortality than HA, especially in younger patients, and it is recommended as the primary treatment for cervical non-pathological hip fractures in patients younger than 80 years and with good ambulatory capacity, whereas the oldest patients can also be safely treated by HA. The third study comprised 82 pairs (OS with three screws and cementless HA): Functional recovery is slightly better after OS with three screws than after uncemented HA, although no significant differences were seen in a sample of this size. On the other hand, OS is associated with a higher re-operation rate. Conclusion: OS seemed somewhat better in terms of functional outcome


The Journal of Bone & Joint Surgery British Volume
Vol. 83-B, Issue 3 | Pages 414 - 418
1 Apr 2001
Clark DI Ahmed AB Baxendale BR Moran CG

In a prospective, controlled study, we measured the effect on cardiac output of the introduction of methylmethacrylate during hemiarthroplasty for displaced fractures of the femoral neck. We treated 20 elderly patients who were similar in age, height, weight and preoperative left ventricular function with either cemented or uncemented hemiarthroplasty. Using a transoesophageal Doppler probe, we measured cardiac output before incision and at six stages of the procedure: during the surgical approach, reaming and lavage of the femoral canal, the introduction of cement, the insertion of the prosthesis, and in reduction and closure. We found that before the cement was introduced, there was no difference in stroke volume or cardiac output (p > 0.25). Cementation produced a transient but significant reduction in cardiac output of 33% (p < 0.01) and a reduction in stroke volume of 44% (p < 0.02). The introduction of cement did not affect the heart rate or mean arterial pressure. There was no significant difference in cardiac function on insertion of the prosthesis. Standard non-invasive haemodynamic monitoring did not detect the cardiovascular changes which may account for the sudden deaths that sometimes occur during cemented hemiarthroplasty. The fall in stroke volume and cardiac output may be caused by embolism occurring during cementation, but there was no similar fall during reaming or insertion of the prosthesis


Bone & Joint 360
Vol. 10, Issue 2 | Pages 43 - 47
1 Apr 2021


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 183 - 183
1 Mar 2008
Rossi R Castoldi F La Russa M Germano M Rossi P
Full Access

The ABG stem (Anatomique Benoist Girard, How-medica) was realized of titanium alloy (TA6V) and it was designed to provide anchoring only at the femour’s metaphyseal portion. The long-term stability is achived by osteointegration of the implant at the metaphyseal region, which is coated with hydroxyapatite (HA) crystals. The plasma-sprayed HA coating has a tickness of 60 μm for the stem. The current study presents radiographic outcomes of more than one hundred primary uncemented HA stems with a long-term follow-up. One hundred and eleven ABG hip arthroplasties were evaluated with a mean follow-up of 9.8 years. The radiographical findings have been classified observing Engh’s stability criteria according to Gruen’s subdivision of the periprosthetic femoral zones. Dividing the hips into two different groups (in the first one the prosthesis implanted 11, 12 or 13 years ago and in the second one the prosthesis with a maximum age of 10 years) it’s possible to see as in the first group the radiolucent lines are quite reduced. Among the older prosthesis the percentage of radiolucent lines is 3.1% in zones 3 and 5 and 18.8% in zone 4. For what concerns the younger ones the percentage are 10.1% (zone 3), 21.5% (zone 4) and 15.2% (zone 5). We believe that there is a load transfer from the metaphyseal to the metadiaphyseal portion of the femur without a worsening of the clinical outcomes. The absence of reactive lines and lucencies around the proximal HA-coated portion of the stem supports an excellent circumferential bony ingrowth in the metaphyseal area of the proximal femur. According to these percentages we can say that there’s less presence of radiolucency in the oldest prosthesis and it could be possible to argue that radiolucent lines tend to reduce along the time. This is probably due to the increase of the strength of the stem anchorage


Bone & Joint Research
Vol. 9, Issue 12 | Pages 884 - 893
1 Dec 2020
Guerado E Cano JR Pons-Palliser J

Aims

A systematic literature review focusing on how long before surgery concurrent viral or bacterial infections (respiratory and urinary infections) should be treated in hip fracture patients, and if there is evidence for delaying this surgery.

Methods

A total of 11 databases were examined using the COre, Standard, Ideal (COSI) protocol. Bibliographic searches (no chronological or linguistic restriction) were conducted using, among other methods, the Patient, Intervention, Comparison, Outcome (PICO) template. We followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines for flow diagram and checklist. Final reading of the complete texts was conducted in English, French, and Spanish. Classification of papers was completed within five levels of evidence (LE).


Bone & Joint 360
Vol. 10, Issue 4 | Pages 37 - 40
1 Aug 2021


Bone & Joint 360
Vol. 9, Issue 4 | Pages 37 - 39
1 Aug 2020


The Bone & Joint Journal
Vol. 102-B, Issue 6 | Pages 693 - 698
1 Jun 2020
Viswanath A Malik A Chan W Klasan A Walton NP

Aims

Despite few good-quality studies on the subject, total hip arthroplasty (THA) is increasingly being performed for displaced intracapsular fractures of the neck of femur. We compared outcomes of all patients with displacement of these fractures treated surgically over a ten-year period in one institution.

Methods

A total of 2,721 patients with intracapsular fractures of the femoral neck treated with either a cemented hemiarthroplasty or a THA at a single centre were retrospectively reviewed. The primary outcomes analyzed were readmission for any reason and revision surgery. We secondarily looked at mortality rates.


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1280 - 1284
1 Oct 2019
Kang JR Logli AL Tagliero AJ Sperling JW

Aims

A number of methods have been described to remove a well-fixed humeral implant as part of revision shoulder arthroplasty. These include the use of cortical windows and humeral osteotomies. The router bit extraction technique uses a high-speed router bit to disrupt the bone-implant interface. The implant is then struck in a retrograde fashion with a square-tip impactor and mallet. The purpose of this study was to determine the characteristics and frequency of the different techniques needed for the removal of a well-fixed humeral stem in revision shoulder arthroplasty.

Patients and Methods

Between 2010 and 2018, 288 revision shoulder arthroplasty procedures requiring removal of a well-fixed humeral component were carried out at a tertiary referral centre by a single surgeon. The patient demographics, indications for surgery, and method of extraction were collected.


Bone & Joint 360
Vol. 8, Issue 5 | Pages 33 - 35
1 Oct 2019


The Bone & Joint Journal
Vol. 102-B, Issue 12 | Pages 1675 - 1681
1 Dec 2020
Uzoigwe CE O'Leary L Nduka J Sharma D Melling D Simmons D Barton S

Aims

Postoperative delirium (POD) and postoperative cognitive decline (POCD) are common surgical complications. In the UK, the Best Practice Tariff incentivizes the screening of delirium in patients with hip fracture. Further, a National Hip Fracture Database (NHFD) performance indicator is the reduction in the incidence of POD. To aid in its recognition, we sought to determine factors associated with POD and POCD in patients with hip fractures.

Methods

We interrogated the NHFD data on patients presenting with hip fractures to our institution from 2016 to 2018. POD was determined using the 4AT score, as recommended by the NHFD and UK Department of Health. POCD was defined as a decline in Abbreviated Mental Test Score (AMTS) of two or greater. Using logistic regression, we adjusted for covariates to identify factors associated with POD and POCD.


The Bone & Joint Journal
Vol. 101-B, Issue 10 | Pages 1292 - 1299
1 Oct 2019
Masters J Metcalfe D Parsons NR Achten J Griffin XL Costa ML

Aims

This study explores data quality in operation type and fracture classification recorded as part of a large research study and a national audit with an independent review.

Patients and Methods

At 17 centres, an expert surgeon reviewed a randomly selected subset of cases from their centre with regard to fracture classification using the AO system and type of operation performed. Agreement for these variables was then compared with the data collected during conduct of the World Hip Trauma Evaluation (WHiTE) cohort study. Both types of surgery and fracture classification were collapsed to identify the level of detail of reporting that achieved meaningful agreement. In the National Hip Fracture Database (NHFD), the types of operation and fracture classification were explored to identify the proportion of “highly improbable” combinations.


Bone & Joint 360
Vol. 9, Issue 5 | Pages 4 - 9
1 Oct 2020
Matthews E Waterson HB Phillips JR Toms AD


Bone & Joint 360
Vol. 9, Issue 4 | Pages 15 - 17
1 Aug 2020


The Bone & Joint Journal
Vol. 101-B, Issue 11 | Pages 1402 - 1407
1 Nov 2019
Cehic M Lerner RG Achten J Griffin XL Prieto-Alhambra D Costa ML

Aims

Bone health assessment and the prescription of medication for secondary fracture prevention have become an integral part of the acute management of patients with hip fracture. However, there is little evidence regarding compliance with prescription guidelines and subsequent adherence to medication in this patient group.

Patients and Methods

The World Hip Trauma Evaluation (WHiTE) is a multicentre, prospective cohort of hip fracture patients in NHS hospitals in England and Wales. Patients aged 60 years and older who received operative treatment for a hip fracture were eligible for inclusion in WHiTE. The prescription of bone protection medications was recorded from participants’ discharge summaries, and participant-reported use of bone protection medications was recorded at 120 days following surgery.


Bone & Joint 360
Vol. 6, Issue 4 | Pages 25 - 29
1 Aug 2017


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 94 - 99
1 Jan 2015
Grammatopoulos G Wilson HA Kendrick BJL Pulford EC Lippett J Deakin M Andrade AJ Kambouroglou G

National Institute of Clinical Excellence guidelines state that cemented stems with an Orthopaedic Data Evaluation Panel (ODEP) rating of > 3B should be used for hemiarthroplasty when treating an intracapsular fracture of the femoral neck. These recommendations are based on studies in which most, if not all stems, did not hold such a rating.

This case-control study compared the outcome of hemiarthroplasty using a cemented (Exeter) or uncemented (Corail) femoral stem. These are the two prostheses most commonly used in hip arthroplasty in the UK.

Data were obtained from two centres; most patients had undergone hemiarthroplasty using a cemented Exeter stem (n = 292/412). Patients were matched for all factors that have been shown to influence mortality after an intracapsular fracture of the neck of the femur. Outcome measures included: complications, re-operations and mortality rates at two, seven, 30 and 365 days post-operatively. Comparable outcomes for the two stems were seen.

There were more intra-operative complications in the uncemented group (13% vs 0%), but the cemented group had a greater mortality in the early post-operative period (n = 6). There was no overall difference in the rate of re-operation (5%) or death (365 days: 26%) between the two groups at any time post-operatively.

This study therefore supports the use of both cemented and uncemented stems of proven design, with an ODEP rating of 10A, in patients with an intracapsular fracture of the neck of the femur.

Cite this article: Bone Joint J 2015;97-B:94–9.


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 250 - 254
1 Feb 2017
Tol MCJM van den Bekerom MPJ Sierevelt IN Hilverdink EF Raaymakers ELFB Goslings JC

Aims

Our aim was to analyse the long-term functional outcome of two forms of surgical treatment for active patients aged > 70 years with a displaced intracapsular fracture of the femoral neck. Patients were randomised to be treated with either a hemiarthroplasty or a total hip arthroplasty (THA). The outcome five years post-operatively for this cohort has previously been reported. We present the outcome at 12 years post-operatively.

Patients and Methods

Initially 252 patients with a mean age of 81.1 years (70.2 to 95.6) were included, of whom 205 (81%) were women. A total of 137 were treated with a cemented hemiarthroplasty and 115 with a cemented THA. At long-term follow-up we analysed the modified Harris Hip Score (HHS), post-operative complications and intra-operative data of the patients who were still alive.


The Bone & Joint Journal
Vol. 95-B, Issue 6 | Pages 862 - 862
1 Jun 2013
Gjertsen J Lie SA Vinje T Engesæter LB Hallan G Matre K Furnes O

We welcome letters to the Editor concerning articles that have recently been published. Such letters will be subject to the usual stages of selection and editing; where appropriate the authors of the original article will be offered the opportunity to reply.


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 291 - 297
1 Mar 2016
Rogmark C Leonardsson O

This review summarises the evidence for the treatment of displaced fractures of the femoral neck in elderly patients. Results from randomised clinical trials and national register studies are presented when available.

The advantages of arthroplasty compared with internal fixation are supported by several studies. A number of studies contribute to the discussions of total hip arthroplasty (THA) versus hemiarthroplasty and unipolar versus bipolar hemiarthroplasty, but no clear-cut evidence-based recommendation can be made. THA may be particularly advantageous for active, lucid patients with a relatively long life expectancy. For patients who are physiologically older, hemiarthoplasty is probably satisfactory, and for the oldest patients with more comorbidities, unipolar implants are considered to be sufficient. If the hospital can support emergency THA surgery in sufficient numbers and quality, there may be few patients who warrant bipolar hemiarthroplasty.

The direct lateral approach reduces the risk of dislocation compared with the posterior approach. Cemented implants lower the risk of periprosthetic fracture and its subsequent morbidity and mortality. As the risk of peri-operative death related to bone cement can be reduced by adequate measures, cemented implants are recommended in fracture cases.

Take home message: There remains a great variation in the surgical management of patients with a hip fracture, and an evidence-based approach should improve the outcomes for this vulnerable patient group.

Cite this article: Bone Joint J 2016;98-B:291–7.


The Bone & Joint Journal
Vol. 97-B, Issue 11 | Pages 1475 - 1480
1 Nov 2015
Inngul C Blomfeldt R Ponzer S Enocson A

The aim of this randomised controlled study was to compare functional and radiological outcomes between modern cemented and uncemented hydroxyapatite coated stems after one year in patients treated surgically for a fracture of the femoral neck. A total of 141 patients aged > 65 years were included. Patients were randomised to be treated with a cemented Exeter stem or an uncemented Bimetric stem. The patients were reviewed at four and 12 months.

The cemented group performed better than the uncemented group for the Harris hip score (78 vs 70.7, p = 0.004) at four months and for the Short Musculoskeletal Function Assesment Questionnaire dysfunction score at four (29.8 vs 39.2, p = 0.007) and 12 months (22.3 vs 34.9, p = 0.001). The mean EQ-5D index score was better in the cemented group at four (0.68 vs 0.53, p = 0.001) and 12 months (0.75 vs 0.58, p = < 0.001) follow-up. There were nine intra-operative fractures in the uncemented group and none in the cemented group.

In conclusion, our data do not support the use of an uncemented hydroxyapatite coated stem for the treatment of displaced fractures of the femoral neck in the elderly.

Cite this article: Bone Joint J 2015;97-B:1475–80.


The Journal of Bone & Joint Surgery British Volume
Vol. 92-B, Issue 8 | Pages 1107 - 1111
1 Aug 2010
Rees JL Dawson J Hand GCR Cooper C Judge A Price AJ Beard DJ Carr AJ

We have compared the outcome of hemiarthroplasty of the shoulder in three distinct diagnostic groups, using survival analysis as used by the United Kingdom national joint registers, patient-reported outcome measures (PROMs) as recommended by Darzi in the 2008 NHS review, and transition and satisfaction questions.

A total of 72 hemiarthroplasties, 19 for primary osteoarthritis (OA) with an intact rotator cuff, 22 for OA with a torn rotator cuff, and 31 for rheumatoid arthritis (RA), were followed up for between three and eight years. All the patients survived, with no revisions or dislocations and no significant radiological evidence of loosening. The mean new Oxford shoulder score (minimum/worst 0, maximum/best 48) improved significantly for all groups (p < 0.001), in the OA group with an intact rotator cuff from 21.4 to 38.8 (effect size 2.9), in the OA group with a torn rotator cuff from 13.3 to 27.2 (effect size 2.1) and in the RA group from 13.7 to 28.0 (effect size 3.1). By this assessment, and for the survival analysis, there was no significant difference between the groups. However, when ratings using the patient satisfaction questions were analysed, eight (29.6%) of the RA group were ‘disappointed’, compared with one (9.1%) of the OA group with cuff intact and one (7.7%) of the OA group with cuff torn. All patients in the OA group with cuff torn indicated that they would undergo the operation again, compared to ten (90.9%) in the OA group with cuff intact and 20 (76.9%) in the RA group.

The use of revision rates alone does not fully represent outcome after hemiarthroplasty of the shoulder. Data from PROMs provides more information about change in pain and the ability to undertake activities and perform tasks. The additional use of satisfaction ratings shows that both the rates of revision surgery and PROMs need careful interpretation in the context of patient expectations.


The Bone & Joint Journal
Vol. 95-B, Issue 11_Supple_A | Pages 7 - 10
1 Nov 2013
Petrie J Sassoon A Haidukewych GJ

Most hip fractures treated with modern internal fixation techniques will heal. However, failures occasionally occur and require revision procedures. Salvage strategies employed during revision are based on whether the fixation failure occurs in the femoral neck, or in the intertrochanteric region. Patient age and remaining bone stock also influence decision making. For fractures in young patients, efforts are generally focused on preserving the native femoral head via osteotomies and repeat internal fixation. For failures in older patients, some kind of hip replacement is usually selected. Disuse osteopenia, deformity, bone loss, and stress-risers from previous internal fixation devices all pose technical challenges to successful reconstruction. Attention to detail is important in order to minimise complications. In the majority of cases, good outcomes have been reported for the various salvage strategies.

Cite this article: Bone Joint J 2013;95-B, Supple A:7–10.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 12 | Pages 1701 - 1701
1 Dec 2005
ABBAS D


Bone & Joint 360
Vol. 2, Issue 5 | Pages 8 - 12
1 Oct 2013
Phillips JRA

Not all questions can be answered by prospective randomised controlled trials. Registries were introduced as a way of collecting information on joint replacements at a population level. They have helped to identify failing implants and the data have also been used to monitor the performance of individual surgeons. This review aims to look at some of the less well known registries that are currently being used worldwide, including those kept on knee ligaments, ankle arthroplasty, fractures and trauma.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1067 - 1070
1 Aug 2012
Melton JTK Mayahi R Baxter SE Facek M Glezos C

A consecutive series of patients with a hydroxyapatite-coated uncemented total knee replacement (TKR) performed by a single surgeon between 1992 and 1995 was analysed. All patients were invited for clinical review and radiological assessment. Revision for aseptic loosening was the primary outcome. Assessment was based on the Knee Society clinical score (KSS) and an independent radiological analysis. Of 471 TKRs performed in 356 patients, 432 TKRs in 325 patients were followed for a mean of 16.4 years (15 to 18). The 39 TKRs in 31 patients lost to follow-up had a mean KSS of 176 (148 to 198) at a mean of ten years. There were revisions in 26 TKRs (5.5%), of which 11 (2.3%) were for aseptic loosening. Other further surgery was carried out on 49 TKRs (10.4%) including patellar resurfacing in 20, arthrolysis in 19, manipulation under anaesthetic in nine and extensor mechanism reconstruction in one.

Survivorship at up to 18 years without aseptic loosening was 96% (95% confidence interval 91.9 to 98.1), at which point the mean KSS was 176 (134 to 200). Of 110 knees that underwent radiological evaluation, osteolysis was observed in five (4.5%), one of which was revised.

These data indicate that uncemented hydroxyapatite-coated TKR can achieve favourable long-term survivorship, at least as good as that of cemented designs.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 5 | Pages 690 - 697
1 May 2012
Khan MA Hossain FS Dashti Z Muthukumar N

The aim of this study was to examine the rates and potential risk factors for 28-day re-admission following a fracture of the hip at a high-volume tertiary care hospital. We retrospectively reviewed 467 consecutive patients with a fracture of the hip treated in the course of one year. Causes and risk factors for unplanned 28-day re-admissions were examined using univariate and multivariate analysis, including the difference in one-year mortality. A total of 55 patients (11.8%) were re-admitted within 28 days of discharge. The most common causes were pneumonia in 15 patients (27.3%), dehydration and renal dysfunction in ten (18.2%) and deteriorating mobility in ten (18.2%). A moderate correlation was found between chest infection during the initial admission and subsequent re-admission with pneumonia (r = 0.44, p < 0.001). A significantly higher mortality rate at one year was seen in the re-admission group (41.8% (23 of 55) vs 18.7% (77 of 412), p < 0.001). Logistic regression analysis identified advancing age, admission source, and the comorbidities of diabetes and neurological disorders as the strongest predictors for re-admission. Early re-admission following hip fracture surgery is predominantly due to medical causes and is associated with higher one-year mortality. The risk factors for re-admission can have implications for performance-based pay initiatives in the NHS. Multidisciplinary management in reducing post-operative active clinical problems may reduce early re-admission.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 530 - 532
1 Apr 2009
Sen D Alsousou J Fraser J

We describe a technique to salvage a painful hemiarthroplasty due to erosion of the acetabular cartilage in the absence of loosening of the femoral component. A press-fit metallic acetabular component which matched the femoral component was used as a metal-on-metal articulation. The procedure offered a shorter operation time with less blood loss and no risk of femoral fracture as might have occurred during conventional revision to a total hip replacement. The patient made an unremarkable recovery with a good outcome at follow-up of 15 months.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 6 | Pages 770 - 777
1 Jun 2008
Edwards C Counsell A Boulton C Moran CG

Prospective data on hip fracture from 3686 patients at a United Kingdom teaching hospital were analysed to investigate the risk factors, financial costs and outcomes associated with deep or superficial wound infections after hip fracture surgery.

In 1.2% (41) of patients a deep wound infection developed, and 1.1% (39) had a superficial wound infection. A total of 57 of 80 infections (71.3%) were due to Staphylococcus aureus and 39 (48.8%) were due to MRSA.

No statistically significant pre-operative risk factors were detected. Length of stay, cost of treatment and pre-discharge mortality all significantly increased with deep wound infection. The one-year mortality was 30%, and this increased to 50% in those who developed an infection (p < 0.001). A deep infection resulted in doubled operative costs, tripled investigation costs and quadrupled ward costs.

MRSA infection increased costs, length of stay, and pre-discharge mortality compared with non-MRSA infection.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1053 - 1059
1 Aug 2006
Foss NB Kehlet H

Our aim was to determine the total blood loss associated with surgery for fracture of the hip and to identify risk factors for increased blood loss. We prospectively studied 546 patients with hip fracture. The total blood loss was calculated on the basis of the haemoglobin difference, the number of transfusions and the estimated blood volume. The hidden blood loss, in excess of that observed during surgery, varied from 547 ml (screws/ pins) to 1473 ml (intramedullary hip nail and screw) and was significantly associated with medical complications and increased hospital stay. The type of surgery, treatment with aspirin, intra-operative hypotension and gastro-intestinal bleeding or ulceration were all independent predictors of blood loss.

We conclude that total blood loss after surgery for hip fracture is much greater than that observed intra-operatively. Frequent post-operative measurements of haemoglobin are necessary to avoid anaemia.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 4 | Pages 523 - 529
1 Apr 2005
Blomfeldt R Törnkvist H Ponzer S Söderqvist A Tidermark J

We studied 60 patients with an acute displaced fracture of the femoral neck and with a mean age of 84 years. They were randomly allocated to treatment by either internal fixation with cannulated screws or hemiarthroplasty using an uncemented Austin Moore prosthesis. All patients had severe cognitive impairment, but all were able to walk independently before the fracture. They were reviewed at four, 12 and 24 months after surgery. Outcome assessments included complications, revision surgery, the status of activities of daily living (ADL), hip function according to the Charnley score and the health-related quality of life (HRQOL) according to the Euroqol (EQ-5D) (proxy report).

General complications and the rate of mortality at two years (42%) did not differ between the groups. The rate of hip complications was 30% in the internal fixation group and 23% in the hemiarthroplasty group; this was not significant. There was a trend towards an increased number of re-operated patients in the internal fixation group compared with the hemiarthroplasty group, 33% and 13%, respectively (p = 0.067), but the total number of surgical procedures which were required did not differ between the groups. Of the survivors at two years, 54% were totally dependent in ADL functions and 60% were bedridden or wheelchair-bound regardless of the surgical procedure. There was a trend towards decreased mobility in the hemiarthroplasty group (p = 0.066). All patients had a very low HRQOL even before the fracture. The EQ-5Dindex score was significantly worse in the hemiarthroplasty group compared with the internal fixation group at the final follow-up (p < 0.001).

In our opinion, there is little to recommend hemiarthroplasty with an uncemented Austin Moore prosthesis compared with internal fixation, in patients with severe cognitive dysfunction.