header advert
Results 1 - 7 of 7
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 938 - 945
1 Aug 2022
Park YH Kim W Choi JW Kim HJ

Aims

Although absorbable sutures for the repair of acute Achilles tendon rupture (ATR) have been attracting attention, the rationale for their use remains insufficient. This study prospectively compared the outcomes of absorbable and nonabsorbable sutures for the repair of acute ATR.

Methods

A total of 40 patients were randomly assigned to either braided absorbable polyglactin suture or braided nonabsorbable polyethylene terephthalate suture groups. ATR was then repaired using the Krackow suture method. At three and six months after surgery, the isokinetic muscle strength of ankle plantar flexion was measured using a computer-based Cybex dynamometer. At six and 12 months after surgery, patient-reported outcomes were measured using the Achilles tendon Total Rupture Score (ATRS), visual analogue scale for pain (VAS pain), and EuroQoL five-dimension health questionnaire (EQ-5D).


The Bone & Joint Journal
Vol. 100-B, Issue 3 | Pages 303 - 308
1 Mar 2018
Park YH Lee JW Hong JY Choi GW Kim HJ

Aims

Identifying predictors of compartment syndrome in the foot after a fracture of the calcaneus may lead to earlier diagnosis and treatment. The aim of our study was to identify any such predictors.

Patients and Methods

We retrospectively reviewed 303 patients (313 fractures) with a fracture of the calcaneus who presented to us between October 2008 and September 2016. The presence of compartment syndrome and potential predictors were identified by reviewing their medical records. Potential predictors included age, gender, concomitant foot injury, mechanism of injury, fracture classification, time from injury to admission, underlying illness, use of anticoagulant/antiplatelet agents, smoking status and occupation. Associations with predictors were analyzed using logistic regression analysis.


The Bone & Joint Journal
Vol. 99-B, Issue 3 | Pages 365 - 368
1 Mar 2017
Park YH Jeong SM Choi GW Kim HJ

Aims

Morton’s neuroma is common condition of the forefoot, but its aetiology remains unclear. Our aim was to evaluate the relationship between the width of the forefoot and the development of a Morton’s neuroma.

Patients and Methods

Between January 2013 and May 2016, a total of 84 consecutive patients (17 men, 67 women) with a unilateral Morton’s neuroma were enrolled into the study. The involved and uninvolved feet of each patient were compared. A control group of patients with symptoms from the foot, but without a neuroma who were matched for age, gender, affected side, and web space location, were enrolled. The first to fifth intermetatarsal distance, intermetatarsal angle and intermetatarsal distance of involved web space on standing radiographs were assessed.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 134 - 134
1 Sep 2012
Yoon TR Park KS Peni I Jung W Park G Park YH
Full Access

Purpose

The purpose of this study is to know the peri-operative morbidity, clinical and radiographical outcomes of conversion THA from failed transtrochanter rotational osteotomy (TRO).

Patients and methods

From 2003 January to 2009 January, there were 18 hips(18 patients) who underwent conversion THA from TRO for osteonecrosis of the femoral head (ONFH) (Group I). The mean duration from TRO to conversion THA was 2.6 years. We made a matched control group of 18 primary THA for ONFH (Group II) and we evaluated perioperative morbidity and complications in each group. For the clinical evaluation, we checked Harris hip score (HHS) and WOMAC score. For the radiographical evaluation, we evaluated implant position, stability and osteolysis.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 83 - 83
1 Sep 2012
Jung W Yoon TR Park KS Park G Park YH
Full Access

Introduction

This study was performed to evaluate the minimum 5-year clinical and radiological results of liner cementation into a stable acetabular shell using a metal-inlay, polyethylene liner during revision total hip arthroplasty (THA).

Methods

Sixty-six hips (63 patients) that underwent revision THA using a metal-inlay polyethylene liner cementation were included. The causes of revision were; polyethylene wear in 37 cases, femoral stem loosening in 20 cases, ceramic head fracture in 4 cases, and recurrent dislocation in 5 cases. Clinical results were graded at final follow-up using Harris hip scores, and radiographs were evaluated to determine acetabular component inclination, the stabilities of acetabular and femoral components, correction of hip centers, and the progression of osteolysis.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 133 - 133
1 Sep 2012
Yoon TR Park KS Jung W Park G Park YH
Full Access

Purpose

Hip arthroplasty is a good treatment option for displaced femoral neck fracture in elderly patients. However, neuromuscular disease such as cerebral infarction or hemorrhage can be a concerning problem for THA since dislocation after operation can frequently occur. The purpose of this prospective study was to evaluate the functional results of modified minimally invasive (MI) two-incision total hip arthroplasty (THA) with the use of large-diameter (>38mm) metal-on-metal articulation in patients with muscle weakness.

Patients and Methods

19 consecutive patients (19 hips) with displaced femoral neck fracture with muscle weakness were enrolled. There were 11 patients with cerebral infarction, 4 patients with cerebral hemorrhage and 4 patients with Parkinson's disease. In the lateral position, an anterolateral approach between the gluteus medius and tensor fascia lata and a posterior approach between the piriformis and gluteus medius were used.

Surgical morbidity, functional recovery, radiological implantation properties, range of motion (ROM) and complications were assessed.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 25 - 25
1 Jun 2012
Chotai P Shon WY Han SB Yoon YC Park YH Siddaraju VM
Full Access

CLS Spotorno expansion acetabular cup is in use since 1984 for uncemented Metal-Polyethylene (PE) total hip arthroplasties (THA). Metal-PE articulations are notoriously known to wear and lead to failure of THA. However, catastrophic breakage of expansion acetabular cup is rare. Our 74-year-old male who was diagnosed with bilateral osteonecrosis of femoral head, underwent bilateral THA using CLS Spotorno metal expansion acetabular cups (Protek, AG, Bern) in 1991. He had irregular follow-up since then. In 2005, he presented with right hip pain and inability to walk without support. Anteroposterior (AP) hip radiographs established the diagnosis of catastrophic failure of right THA secondary to severe liner wear and acetabular osteolysis. Patient chose to postpone the revision surgery and opted for wheel chair ambulation. He presented 4 years later, when the right hip pain became unbearable. Anteroposterior as well as lateral hip radiographs showed worsening of cup breakage with superolateral migration of metal femoral head. Pelvic CT scans confirmed severe acetabular osteolysis in DeLee and Charnley's Zone 1, 2 & 3 with secondary loss of bony support to the expansion cup [Fig. 1]. A revision THA was strongly advised. However, patient sought for a pain-free rather than a fully ambulatory right hip and decided against a second THA. We performed resection arthroplasty of right hip with bone cement loading, respecting patient's decision. Intra-operatively, the metal femoral head was lying in the huge osteolytic defect in the roof of acetabulum. The 3 cranial wings of metal expansion shell were broken with corresponding wear of the cranial pole of polyethylene liner [Fig. 2]. We were able to gratify patient's expectations and patient is able to ambulate with the aid of one crutch at latest follow-up. However, it is clearly evident that a timely and regular follow-up would have identified the initial PE wear and secondary osteolysis. Additionally, it can avoid extensive procedures like a revision THA or resection arthroplasty by allowing simple procedures like modular PE liner and the femoral head exchange. A comprehensive review of literature for catastrophic acetabular component breakage revealed 10 such cases, although with different cup designs. To the best of our knowledge, this is the first case of CLS expansion cup breakage for metal-PE articulation. Majority of these cases have a presence of extensive liner wear and pelvic osteolysis along with a post-operative irregular follow up. This case stresses on importance of regular follow-up even after many years of index THA to identify early PE wear and prevent secondary catastrophic complications.