Over the last few decades, the All-Poly Monoblock Tibia has been relegated to a minimum use in the major healthcare systems of the western world. The main reason for this has been the perception that this tibial component is inferior in its ability to withstand stresses. This perception originated and subsequently gained ground, due to certain historical reasons, leading to the widespread use of the modular metal-backed tibial component despite a higher cost.

The recent economic downturn has enforced even the rich western healthcare systems to look for cost-effective solutions. The author works in India, where the society is still highly price-sensitive and takes value for money very seriously. Further, the routine ADL of the Indian population requires them to adopt high flexion postures such as cross-legged sitting and squatting. The author has used the All-Poly Tibia extensively, which is the most economical of tibial components. Further, he has developed a surgical technique which has resulted in his patients achieving high flexion (greater than 135 degrees) in more than 75% cases.

This paper presents the 10 year results of a series of 500 cases of Primary TKR in which the All-Poly Monoblock Tibia had been used. All the patients had cross-legged sitting activity as part of their ADL, thus presumably generating significant pressures on the joint surfaces. Of the original 500 cases, we could follow up 434 cases. We report a 96% survival rate of the implant in this series. There was not a single aseptic plastic failure. The revisions required were due to infection, peri-prosthetic fracture, and instability.

The message being conveyed in this paper is that the All-Poly Tibia is a very cost-effective solution in routine Primary TKRs, and is able to deliver excellent long-term results even in high stress situations like cross-legged sitting activity. It would offer a huge cost savings to the healthcare system if the Orthopaedic Surgeons start using this implant more frequently.


The Journal of Bone & Joint Surgery British Volume
Vol. 76-B, Issue 4 | Pages 607 - 609
1 Jul 1994
Mody B Patil S Carty H Klenerman L

We describe three cases of traumatic myositis ossificans in which fractures occurred through a mature, quiescent ossification mass. None of the fractures reactivated the original pathological process, no callus was formed and union did not occur. The nonunion became painless over a period of months. This unusual late complication of myositis ossificans seems to require only symptomatic treatment by temporary splintage and subsequent mobilisation. We could find no previous report of a similar case.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 5 | Pages 818 - 821
1 Sep 1993
Mody B Howard L Harding M Parmar H Learmonth D

We treated 39 knees with chronic deficiency of the anterior cruciate ligament by reconstruction using the ABC carbon and polyester prosthetic ligament; 31 (79.5%) were reviewed at an average follow-up of 34 months. There had been four complete failures requiring revision. The remaining 27 were studied in detail. On the Lysholm rating, only 11 knees (41%) had good results with a score of over 76. The mean anterior drawer movement was reduced from 7.6 mm before operation to 5.8 mm at review. The mean difference from the opposite uninjured knee was 3.9 mm before operation, 1 mm (in 21 patients) at mean follow-up of 7.4 months and 2.5 mm (in 27 patients) at 34 months, indicating progressive loss of effect. In our opinion the results are unsatisfactory: we do not recommend the use of this prosthetic ligament.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 479 - 482
1 May 1993
Dias J Thomas I Lamont A Mody B Thompson

Ultrasound scans were made of the hips of 209 neonates born consecutively over a two-week period. Of the 418 scans, 62 images were selected at random and 25 of these were duplicated to give a total of 87 scans. These static images were then presented to five experienced observers who each made nine different assessments and measurements. Interobserver and intraboserver agreement was calculated and expressed as kappa values. Our results showed poor reliability on both counts.


The Journal of Bone & Joint Surgery British Volume
Vol. 75-B, Issue 3 | Pages 423 - 425
1 May 1993
Mody B Belliappa P Dias J Barton N

Fracture of the tuberosity of the scaphoid is common and usually heals without incident because of the good blood supply. We report four cases of nonunion of this fracture. Three of them were symptomatic and two required operative treatment.