header advert
Results 1 - 2 of 2
Results per page:
Applied filters
Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_I | Pages 73 - 73
1 Mar 2008
Gallimore C Koo H McConnell A Schemitsch E
Full Access

The purpose of this study was to determine the effect of cement mixing time on fixation augmentation in both healthy and simulated osteoporotic canine bone. In a canine diaphyseal model, screw insertion into liquid cement achieves greater bending stiffness and resists a greater load to failure than cement inserted as a paste. Bone cement in its liquid state may provide increased structural support in the setting of an osteoporotic fracture, possibly due to increased interdigitation of the cement with the screw threads and bone.

An inconsistency exists among orthopaedic surgeons with regards to the appropriate mixing time for bone cement to achieve optimal results. The purpose of this study was to determine the effect of cement mixing time on fixation augmentation in both healthy and simulated osteoporotic canine bone.

In a canine diaphyseal fracture model, screw insertion into liquid cement achieves greater bending stiffness and resists a greater load to failure than insertion into cement with the consistency of a paste.

Bone cement in its liquid state may provide increased structural support in the setting of an osteoporotic fracture, possibly due to increased interdigitation of the cement with the screw threads and bone.

Baseline stiffness for fourteen pairs of cadaveric canine femora was determined. A transverse diaphyseal osteotomy was created and fixed using an eight-hole DC plate and 3.5 mm screws. A 1cm gap was created at the osteotomy site simulating loss of bone. In the left femora, cement was mixed for one minute (liquid) prior to injection into pre-drilled holes; in the right femora, cement was mixed for five minutes prior to injection (thick paste). In each mixing time group, seven specimens were treated with a plate and properly sized pre-drilled and tapped holes (2.5mm), and seven received over-drilled holes (3.2 mm) to simulate osteoporotic bone. Four-point bending stiffness was determined for each plated construct, and normalized to baseline stiffness. Specimens were then loaded to failure.

Within the properly sized holes, there were no statistically significant differences (SSD) in bending stiffness with or without a gap. The liquid cement had a force to failure 77% greater than that of cement as a paste (p< 0.05). Within the over-sized holes, there was no SSD between liquid and paste without a gap. With a gap, liquid cement demonstrated an increased bending stiffness of 24 % (p< 0.05) and force to failure was 92% higher (p< 0.05).


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 307 - 307
1 Sep 2005
Gallimore C Koo H McConnell A Schemitsch E
Full Access

Introduction and Aims: Bone cement (Polymethylmethacrylate) is commonly used to augment internal fixation in osteoporotic bone. An inconsistency exists among surgeons regarding the appropriate mixing time for bone cement to achieve optimal screw purchase. The study addresses the effect of cement viscosity on fixation augmentation in both healthy and simulated osteoporotic canine bone.

Method: Fourteen canine femora were plated using eight-hole DC plates and 3.5mm screws, repairing transverse diaphyseal osteotomies with and without a gap. In the left femora, cement was mixed for one minute (liquid) prior to injection into drilled and tapped holes that were either properly sized (2.5mm) or over-drilled (3.2mm) to simulate osteoporotic bone. In the right femora, cement was mixed for five minutes prior to injection (thick paste). Four-point bending stiffness for each plated construct was normalised to baseline stiffness, followed by failure loading.

Results: Within the properly sized holes, there were no significant differences in bending stiffness with or without a gap at the fracture site. The liquid cement had a force to failure 77% greater than that of cement as a paste (p< 0.05).

Within the over-sized holes simulating osteoporotic bone, there was no difference between liquid and paste without a gap. With a gap, liquid cement demonstrated an increased bending stiffness of 24% (p< 0.05) and force to failure was 92% higher (p< 0.05).

Bone cement in its liquid state may provide increased structural support in the setting of an osteoporotic fracture, possibly due to increased interdigitation of the cement with the screw threads and bone.

Conclusion: In a canine diaphyseal fracture model, screw insertion into liquid cement achieves greater bending stiffness and resists a greater load to failure than insertion into cement with the consistency of a paste.