header advert
Results 1 - 8 of 8
Results per page:
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 53 - 53
1 May 2016
Itayem R Lundberg A Arndt A
Full Access

Introduction

While fixation on the acetabular side in resurfacing implants has been uncemented, the femoral component is usually cemented. The most common causes for early revision in hip resurfacing are femoral head and or neck fractures and aseptic loosening of the femoral component. Later failures appear to be more related to adverse soft-tissue reactions due to metal wear. Little is known about the effect of cementing techniques on the clinical outcome in hip resurfacing, since retrieval analysis of failed hip resurfacing show large variations. Two cementing techniques have dominated. The indirect low viscosity (LV) technique as for the Birmingham Hip resurfacing (BHR) system and the direct high viscosity (HV) technique as for the Articular Surface replacement (ASR) system. The ASR was withdrawn from the market in 2010 due to inferior short and midterm clinical outcome. This study presents an in vitro experiment on the cement mantle parameters and penetration into ASR resurfaced femoral heads comparing both techniques.

Methods

Five sets of paried frozen cadavar femura (3 male, 2 female) were used in the study. The study was approved by ethics committee. Plastic ASR replicas (DePuy, Leeds, UK), femoral head size 47Ø were used. The LV technique was used for the right femora (Group A, fig. 1 and 3) while the HV technigue was used for the left femora (Group B. Fig 2 and 4). The speciments were cut into quadrants. An initiial visual, qualitative evaluation was followed by CT analysis of cement mantle thickness and cement penetration into bone.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 5 | Pages 665 - 677
1 May 2011
Sköldenberg OG Salemyr MO Bodén HS Lundberg A Ahl TE Adolphson PY

Our aim in this pilot study was to evaluate the fixation of, the bone remodelling around, and the clinical outcome after surgery of a new, uncemented, fully hydroxyapatite-coated, collared and tapered femoral component, designed specifically for elderly patients with a fracture of the femoral neck.

We enrolled 50 patients, of at least 70 years of age, with an acute displaced fracture of the femoral neck in this prospective single-series study. They received a total hip replacement using the new component and were followed up regularly for two years.

Fixation was evaluated by radiostereometric analysis and bone remodelling by dual-energy x-ray absorptiometry. Hip function and the health-related quality of life were assessed using the Harris hip score and the EuroQol-5D.

Up to six weeks post-operatively there was a mean subsidence of 0.2 mm (−2.1 to +0.5) and a retroversion of a mean of 1.2° (−8.2° to +1.5°). No component migrated after three months. The patients had a continuous loss of peri-prosthetic bone which amounted to a mean of 16% (−49% to +10%) at two years. The mean Harris hip score was 82 (51 to 100) after two years.

The two-year results from this pilot study indicate that this new, uncemented femoral component can be used for elderly patients with osteoporotic fractures of the femoral neck.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 311 - 311
1 May 2010
Sköldenberg O Salemyr M Muren O Lundberg A Ahl T Bodén H Adolphson P
Full Access

Background: The standard fixation of femoral stems used for patients with femoral neck fractures is bone cement. Bone cement has side effects related to co-morbidity. The purpose of this study is to evaluate fixation, bone remodelling and clinical results with a new uncemented, fully hydroxyapatite-coated tapered femoral stem (Fracture Stem®) designed for press-fit insertion in patients with femoral neck fractures.

Methods: Forty patients (25 women, 15 men) at a mean 82 (70–92) years of age with an acute displaced femoral neck fracture were included in the study. The patients were operated with the new stem and received a total hip arthroplasty. Tantalum markers were placed in the proximal femur during surgery. We have so far followed the patients for 1 year postoperatively with radiostereometric measurements, dual-energy x-ray absorptiometry and clinical evaluation including Harris hip score, pain numerical rating scale and health related quality of life.

Results: The stem showed good fixation. Subsidence and stem rotation for all stems but five were close to zero. Maximum total point motion increased above precision error at the 6 weeks follow-up but did not increase significantly after that. All stems with significant migration were stable after 3 months. We have had no per–or postoperative fracture. One stem has had to be revised because of a deep infection. Median bone loss after 6 months was significant (p=0.018 to 0.028) in all zones but Gruen zone 4. Bone loss was greatest in Gruen zone 1, 2, 6 and 7 with 29%, 22%, 18% and 32% loss respectively. Median Harris hip score decreased significantly (p=0.003) from 89 before fracture to 75 and 78 at the 6 weeks and 6 months follow-up. Pain numerical rating scale and Health related quality of life decreased until the 6 week visit but returned to prefracture value at 6 months.

Conclusions: According to these early 1-year results, Fracture Stem® shows good fixation and fast ingrowth in osteoporotic bone. Periprosthetic bone loss due to stress-shielding was significant in all zones but zone 4. Clinically the stem behaved as expected. According to our results, we propose a randomized cinical trial in a larger patient population as the next step to evaluate this femoral stem.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 9 | Pages 1140 - 1143
1 Sep 2007
Itayem R Arndt A McMinn DJW Daniel J Lundberg A

The early designs of hip resurfacing implants suffered high rates of early failure, making it impossible to obtain valuable mid-term radiostereophotogrammetric (RSA) results. The metal-on-metal Birmingham Hip Resurfacing arthroplasty has shown promising mid-term results and we present here the first mid-term RSA analysis of a hip resurfacing implant.

The analysis was performed in 19 hips at five years post-operatively. The mean acetabular component translation and rotation, and femoral component translation were compared with the previous RSA measurements at two and six months, and one and two years.

There was no statistical significance (t-test, p ≤ 0.05) between these consecutive movements, indicating the mid-term stability of the implant.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 2 | Pages 158 - 162
1 Feb 2005
Itayem R Arndt A Nistor L McMinn D Lundberg A

The Birmingham hip resurfacing metal-on-metal arthroplasty was introduced in 1997 and has shown promising short- to mid-term results. We used radiostereophotogrammetric analysis (RSA) to study the stability of 20 resurfacing arthroplasties over a follow-up period of 24 months.

Radiological examinations for RSA were performed immediately after surgery and at two, six, 12 and 24 months after operation. Precision and detection of migration thresholds (non-zero movement) were calculated.

All the results corresponded well to those found in similar experimental arrangements with standard hip prostheses. Migration of the cup and vertical and mediolateral migration of the head were calculated. The values were low at two years compared with those of earlier studies of cemented femoral components in conventional total hip replacements indicating that there was no evidence of excessive early migration or loosening of the components.


The Journal of Bone & Joint Surgery British Volume
Vol. 85-B, Issue 4 | Pages 538 - 544
1 May 2003
Ericson A Arndt A Stark A Wretenberg P Lundberg A

We analysed the axis of movement in the normal elbow during flexion in vivo using radiostereometric analysis (RSA). The results show an intraindividual variation in the inclination of the axis ranging from 2.1° to 14.3° in the frontal and from 1.6° to 9.8° in the horizontal plane analysed at 30° increments. The inclination of the mean axis of rotation varied within a range of 12.7° in the frontal and 4.6° in the horizontal plane. In both planes, the mean axes were located close to a line joining the centres of the trochlea and capitellum. The intra- and interindividual variations of the axes of flexion of the elbow were greater than previously reported. These factors should be considered in the development of elbow prostheses.


The Journal of Bone & Joint Surgery British Volume
Vol. 74-B, Issue 4 | Pages 495 - 500
1 Jul 1992
Saddegh M Lindholm J Lundberg A Nilsonne U Kreicbergs A

In a retrospective study of all 137 patients with soft-tissue sarcoma treated by surgery between 1972 and 1984, the clinical course was related to several host and tumour features, including the Surgical Staging System of Enneking, Spanier and Goodman (1980). Only patients free from metastasis with untreated primary lesions on admission were included. According to the Surgical Staging System, nine tumours were IA, 18 IB, 38 IIA and 72 IIB. Only 12 patients underwent amputation; 125 were treated by local surgery. The mean follow-up time was ten years (minimum five). For the whole series the probability of seven-year survival was 0.65; 42 patients (31%) died from tumour disease. All these had metastases and 24 also had local recurrence. The local recurrence rate was 36%. Multivariate analysis identified large tumour size and high histological grade as significant risk factors for metastatic disease and tumour-related death. Sex, age, tumour site, surgical margin and local recurrence showed no correlation with survival. The prognostic contribution of compartmentality was virtually nil. Histological grade combined with tumour size was found to give better prognostic information than that obtained by the Surgical Staging System.


The Journal of Bone & Joint Surgery British Volume
Vol. 71-B, Issue 1 | Pages 94 - 99
1 Jan 1989
Lundberg A Svensson O Nemeth G Selvik G

The axis of the talo-crural joint was analysed by roentgen stereophotogrammetry in eight healthy volunteers. Examinations were performed at 10 degrees increments of flexion and pronation/supination of the foot as well as medial and lateral rotation of the leg. Results indicate that the talo-crural joint axis changes continuously throughout the range of movement. In dorsiflexion it tended to be oblique downward and laterally. In rotation of the leg, the axis took varying inclinations between horizontal and vertical. All axes in each subject lay close to the midpoint of a line between the tips of the malleoli. Our study indicates that the talo-crural joint axis may alter considerably during the arc of motion and differ significantly between individuals. This prompts caution in the use of hinge axes in orthoses and prostheses for the ankle.