header advert
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 148 - 148
4 Apr 2023
Jørgensen P Kaptein B Søballe K Jakobsen S Stilling M
Full Access

Dual mobility hip arthroplasty utilizes a freely rotating polyethylene liner to protect against dislocation. As liner motion has not been confirmed in vivo, we investigated the liner kinematics in vivo using dynamic radiostereometry.

16 patients with Anatomical Dual Mobility acetabular components were included. Markers were implanted in the liners using a drill guide. Static RSA recordings and patient reported outcome measures were obtained at post-op and 1-year follow-up. Dynamic RSA recordings were obtained at 1-year follow-up during a passive hip movement: abduction/external rotation, adduction/internal rotation (modified FABER-FADIR), to end-range and at 45° hip flexion. Liner- and neck movements were described as anteversion, inclination and rotation.

Liner movement during modified FABER-FADIR was detected in 12 of 16 patients. Median (range) absolute liner movements were: anteversion 10° (5–20), inclination 6° (2–12), and rotation 11° (5–48) relative to the cup. Median absolute changes in the resulting liner/neck angle (small articulation) was 28° (12–46) and liner/cup angle (larger articulation) was 6° (4–21). Static RSA showed changes in median (range) liner anteversion from 7° (-12–23) postoperatively to 10° (-3–16) at 1-year follow-up and inclination from 42 (35–66) postoperatively to 59 (46–80) at 1-year follow-up. Liner/neck contact was associated with high initial liner anteversion (p=0.01).

The polyethylene liner moves over time. One year after surgery the liner can move with or without liner/neck contact. The majority of movement is in the smaller articulation between head and liner.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 138 - 138
1 Jul 2014
Verboom E van Ijsseldijk E Valstar E Kaptein B de Ridder R
Full Access

Summary

In this study we validate that weight-bearing images are needed for accurate polyethylene liner wear measurement in total knee prostheses by measuring the difference in minimum joint space width between weight-bearing and non-weight-bearing RSA views.

Introduction

Recent studies show that Model-based Roentgen Stereophotogrammetric Analysis is superior to the conventional in vivo measurements of polyethylene liner wear in total knee prostheses. Although it is generally postulated that weight-bearing (standing) views are required to detect liner wear, most RSA images are acquired in non-weight-bearing (supine) view for practical reasons. Therefore, it would be of interest to know if supine views would be sufficient for measuring TKA liner wear, defined as a change in minimum joint space width (mJSW). As a difference in mJSW between weight-bearing and non-weight-bearing RSA images has never been validated, the aim of this study is to compare the outcome of in vivo measurements of mJSW in total knee prosthesis when conducted with weight-bearing and non-weight-bearing RSA views.